Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.3 L+₹33,711 (1.99%)Rejected-Finance MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹17.4 L+₹39,937 (2.35%)Rejected-AOC | L3 | Rejected-AOC BEING L3 | |
| 4 | L4₹21.1 L+₹4.1 L (24.4%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L4 | Rejected-Finance BEING L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Mar 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / MAINT OF DG SET AND ASSOCIATED WORKS AT HARNI, HARNI AIRIFIELD AND REPAIR / MAINT OF DG SET / AMF PANEL AND ITS CONNECTED ITEMS AT MAKARPURA AT AF STN BARODA
2023_MES_579150_1
8783/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹40,000
Yes
3 Apr 2023
4 Feb 2023
4 Mar 2023
4 Feb 2023
2 Mar 2023
18 Feb 2023
6 Feb 2023 - 13 Feb 2023
Amount
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand and gently punning down below/around cable complete all as specified and directed. Note : Punned thickness shall be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abutting each other width equal to length of brick etc complete all as specified and directed.
Laying only burnt bricks (old size) retrieved from above items laid in trenches as cable protection complete all as specified and directed.
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia for cable protection complete all as specified and directed.
Supply, laying and fixing galvanised iron pipe light grade, laid under roads/ drain / along with the pole /fixing of airtermination rod with flat iron clamps, bolts, nuts washers complete all as specified and directed of following size:-
Size of 40 mm bore dia.
Size of 50 mm bore dia.
Supply, laying, jointing, testing and commissioning of LT underground, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, Heavy duty, electric power cable laid in trenches/ ducts/fixed on pole/ wall / laid under road / path / culvert / drains / culverts encased in GI pipe, electric cable with aluminium stranded conductor, including jointing and testing 1100 volts grade with necessary lugs and compression brass glands including taking down old cable complete all asspecified and directed for the following Note: Excavation, earthwork will be measured and paid separately under respective items of this schedule.
25 Sq mm 4 Core
35 sqmm 3.5 core
50 sqmm 3.5 core
Repairs/ servicing to 320 KVA DG set (Make- Kirloskar) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal ,replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality, and testing for smooth running at rated speed all as per manufacturer’s specification complete all as specified and directed for the replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Corrossion inhibitor
Main Supply fuel Pipe
Description all as per item No.10.00 here-in-before, but for 82.5 KVA DG Set-03 (for AF net -02 (Harni) and Nodal Point, Make- Kirloskar) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Description alll as per item No.10.00 here-in-before, but 82.5 KVA DG Set -02 Nos (for AF NET Makarpura- Sudhit) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Descripton all as per item No.10.00 here-in-before but 125 KVA DG Set -02 Nos (for 57 ASP & Tetra Make- Greaves) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Description all as per item No.10.00 here-in-before but 125 KVA DG Set -01 Nos (for 25 Sqn, Make Mahindra Power) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Description all as per item No.10.00 here-in-before but 100 KVA DG Set-01 (for Spyder Bldg Make- Greaves) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Description all as per item No.10.00 here-in-before but 50 KVA DG Set-01 (for Pump house Harni, Make- Kirloskar) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Description all as per item No.10.00 here-in-before but 50 KVA DG Set-01 (for Pump house Harni, Make- Mahindra and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Description all as per item No.10.00 here-in-before but 30 KVA DG Set -02 Nos (for STP makarpura & AVONIC L2 point Make- Greaves) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Description all as per item No.10.00 here-in-before but 62.5 KVA DG Set-01 Nos (for Jagat Naka P/H New Ceo Complex, Make- Ashok Leyand Ashok leyand) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner/outer
Description all as per item No.10.00 here-in-before but 62.5 KVA DG Set-01 Nos (for New Ceo Complex Make: Cummins and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter Inner
Air filter Outer
Description all as per item No.10.00 here-in-before but 30 KVA DG Set-01(for perimeter security lights Make- Kirloskar) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter
Description all as per item No.10.00 here-in-before but 25 KVA DG Set-03 Nos (for perimeter security lights harni, Iron project office & Tech bldg Make- Kirloskar) and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Description all as per item No.10.00 here-in-before but 20 KVA DG Set-03 (for perimeter security lights at Makarpura - Kiroskar and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Air filter
Description all as per item No.10.00 here-in-before but 15 KVA DG Set- 04 Nos installed behind (57 ASP, Post-3,5 & 8 at Harni) Make-Mahindara and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Description all as per item No.10.00 here-in-before but 10 KVA DG Set 03 installed at (25 sqn,10 sqn & Power House station medicare centrer Make-Mahindra & Mahindra and consisting replacement of following parts:-
Element Fuel filter
Element lube Oil filter
Note: for item no 10.00 to 25.00:- (i) The contractor should carry out servicing through authorised DG Service provider & not by any local mechanic (ii) The contractor should be responsible to maintain the DG set in serviceable condition for entire contract period & additional worn out spare parts like O Rings, gasket, screws, fuel pipe, fuel & oil pressure gauge, fan belt etc if found unserviceable should be replaced by contractor without additional cost .(iii) Proper servicing certificate should be produced immediately after servicing (d) Proper register for running of DG set should be maintained (e) The authorised mechanic should visit once in two months for preventive maintenance & any no of emergency breakdown. (f) Total number of serevice visit will be limited upto 5 Nos during the entire contract period including attending any emergency fault in DG Set
Labour only for attending the complaints of DG set with AMF Panel carried out by manufacture's authorised mechanic from the servicing centre without any delay for rectifying the defects by carefully opening and check the DG set parts to find out defects if any at site and replace the defected parts from the DG Set for smooth functioning complete all as specified and directed. (Replacement of parts shall be measured and paid seperately under schedule). Note: If contractor not attend the complaint within 4 hrs penalty will be applied @ Rs. 550 per hours.
Fuel flexible pipe wire braded,1,1/4''to 3/8''PVC best quality.
Oil pressure gauge of existing make.
Water temperature gauge of existing make
Ignition switch of existing make
Indicating lamp
Battery terminal heavy duty of brass of existing make.
Fan belt set Make Fenner/ Dunlock or Equivalent make approved by GE.
Self starter 12 volts Make:Lucas/ Tvs or Equivalent make approved by GE.
Self starter 24 volts Make:Lucas or Equivalent make approved by GE.
AVR for 320/200 KVA DG Set
AVR for 82.5 to 125 KVA DG Set
AVR for 60 KVA to 82.5 KVA DG Set
AVR for 50 KVA to 60 KVA DG Set
AVR for 30 KVA to 50 KVA DG Set
AVR for up to 30 KVA DG Set
Battery lead 1.5 metre long, heavy duty, multi stranded copper conductor, PVC insulated 16 Sqmm single core.
Dynamo 12 volts Make- Lucas or Equivalent make approved by GE.
Fuel injector pump for DG set cap 82.5 KVA to 320 KVA
Fuel injector pump or DG set cap 5 KVA to 60 KVA
Radiator for DG set cap 82.5 KVA to 320 KVA of existing make
Radiator for DG set cap 5 KVA to 60 KVA of existing make
Solenoid Valve
Vibration pad
M&L for cleaning and descaling of radiator assembly by using suitable chemical (MAC solution) and by blower fan and by injecting water in high pressure in water tubings so as to remove all dirts etc in the fins complete all as specified and directed for following capacity
Opening, dismentaling and repair/servicing of Self starter 12/24 volts replacing burnt/ wornout spares, parts asembling after repair and testing complete all specified and directed (spares shall be measured and paid separately)
Supply and fixing the following spares in self starter 12/24 voltas as per existing make and model complete all as specified and directed
Armature coil
Field coil
Carbon brush
Copper bush
Solenoid switch
Material and labour for Maintenance of AMF panel and cleaning of dust inside with blower, cleaning of moving part /contacts from CT cleaner, tightening of loose parts /electrical wires, cleaning of contactors, relays and junction points, servicing/ adjustment of relay, complete testing of AMF relay with necessary settings and load management system complete with replacement of worn out unserviceable components /burnt wires thimbles /lugs complete tested For DG set up to 200 KVA complete all as specified and directed. Note :- Parts /components for replacement shall be measured and paid seperately.
S&F following spare parts in AMF panels complete all as specified and directed.
Supply failure timer of existing make.
Restoration timer of existing make.
Microprocessor based AMF Module incorporating of supply and restoring timer 3 impulse automatic engine start /stop/ logic & fails to start locknut Mains/generator voltage, frequency sensing.
Diod 25 Amp thread type
Auxillary contactor 3 phase suitable for AMF Panel
NC/No relay of existing make
Under voltage relay of existing make
Time Delay relay of existing make
CT's coil 5/250 for 320 KVA DG Set
CT's coil 5/250 for 200 KVA DG Set
CT's coil 5/150 for 125 KVA DG Set
CT's coil 5/50 for 82.5 KVA DG Set
CT's coil 5/50 for up to 50 KVA DG Set
Contactor MCX 43 of 400 A, 415 Volt for 320 KVA DG Set
Contactor 4 pole 315 Amps for 200 KVA DG set
Contactor 4 pole 250 Amps for 125 KVA DG set
Contactor 4 pole 200 Amps for 82.5 KVA DG set
Contactor 4 pole 63 Amps for upto 63 KVA DG set
Battary charger in AMF Panel
Controller for 82.5 KVA TO 200 KVA
Controller for 05 KVA TO 62.5 KVA
Contactor coil for 200 KVA
Contactor coil for 125 KVA
Contactor coil for 50 KVA TO 82.5 KVA
Contactor coil for up to 30 KVA
HRC fuse for short circuit protection
M & L for removing existing old rusted paint on DG set of painted surface and applying with two coats of synthetic enamel spray paint to match with existing colour good finish of following capaity complete all as specified and directed.
125 KVA/100 KVA
Up to 30 KVA
Supply only coolant for Cummins DG sets Make- Fleet Guard.
Supply only engine Oil 15W40 Valvoline for all DG Sets
Supply distle water
Repair & Maintenance of existing canopy of eco friendly DG Set above cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as specified and directed.
M & L for rewinding of DG set alternator of capactity 60 to 82.5 KVA with existing size and gauge and adequate number of turns of super enamelled copper winding wire and bore conductor including varnishing insulating material drying baking heating and connection leads with thimble and making connection complete all as specified and directed.
M & L for rewinding of DG set alternator of capactity 100 to 320 KVA with existing size and gauge and adequate number of turns of super enamelled copper winding wire and bore conductor including varnishing insulating material drying baking heating and connection leads with thimble and making connection complete all as specified and directed.
M & L for rewinding of DG set alternator of capactity upto 50 KVA with existing size and gauge and adequate number of turns of super enamelled copper winding wire and bore conductor including varnishing insulating material drying baking heating and connection leads with thimble and making connection complete all as specified and directed.
Supply, install, testing & commissioning in repairs exide battery 12 V, 130 AH, complete all as specified and directed
Supply, install, testing & commissioning in repairs exide battery 12 V, 100 AH, complete all as specified and directed
Supply, install, testing & commissioning in repairs exide battery 12 V, 150 AH complete all as specified and directed
Supply, install, testing & commissioning in repairs exide battery 12 V, 180 AH complete all as specified and directed
Supply, install, testing & comissioning in repairs PLA relay 24 volt DC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed
Supply, install, testing & comissioning in repairs PLA relay 110-220 volt AC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed
Supply, install, testing & comissioning in repairs Battery charger 24 volt 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed
Supply, install, testing & comissioning in repairs SMPS Battery charger 12 volt 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.3mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and directed
Supply, install, testing & commissioning in replacement of faulty TC contactor LC1FDP1154AEM5 AC-1 of 200 A, 415 Volt rated capacity with coil voltage 220 V 50 Hz DIN switch TA1 DN 22 and connected relays make C&S or equivalent complete all as specified and directed
S&F in repair digital three phase Ampere meter 0-500 volts of size 96x96mm complete all as specified and directed.
S&F in repair digital AC three phase, 04 Wire Electronic KWH meter CT-2E LCD,240 volts, 50 Hz upto 15000 Imp/KWH, IEC 61036 complete all as specified and directed
Supply and Laying 3 core flexible copper conductor cable of size 2.5 Sqmm dia complete all as specified and directed
Supply and fix Rigid Non metallic PVC Conduit of 40 mm dia exclusive of boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock, nuts, saddles complete all as specified and directed
Supply and fix in repair off load change over switch of 160 Amp Capacity fixed in existing panel complete all as specifed and directed.
Supply and fix in repair off load change over switch of 200 Amp Capacity with sheet Steel enclosure all as specified and directed
Supply & install, testing & commissioning in repairs LT feeder panel box compartmental type,Lockable fabrication with dimension 800(H) x 500(W) x 500(D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following complete all as specified and directed :- (a)Automatic transfer Switch 200- Amp - 1 Nos (b)MCB SPN DP 16 Amp, - 2 Nos(Outgoing) (c)Internal wiring 4 Sqmm copper wire (d) indicating Lamp LED type R,Y,B - 3 Nos (e) Voltmeter 0-500 Volt-01 Nos (f) Amperemeter 0-500 Amps-01 Nos Note: Rate of panel is included the wirring of panel to DG set and testing of panel for auto start of DG Set.
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 250 Amps, 35 / 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 200 Amps, 35 / 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 160 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps,25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 40 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 63 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed
M & L for cleaning of area around the DG set up to 20 mtr and cleaning of DG Set, plinth, AMF Panel complete all as specifed and directed
M/S HARI CONSTRUCTION
Shiv Kripa Tradimg
Harsh Infrastructure
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .