| 1 | L1₹10.0 LAccepted-Finance DOOR NO 7 2 30 3 OPP APSEB SUB STATION OLD GAJUWAKA MARRIPALEM VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹11.8 L+₹1.9 L (18.6%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 |
Tender Value
₹13.1 L
EMD Value
₹26,180
Closing Date
5 Oct 2024, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
PROVISION OF FIRE DETECTION AND ALARM SYSTEM AT TELEPHONE EXCHANGE BLDG HQENC, REPLACEMENT OF BER AUTOMATIC FIRE DETECTION SYSTEM (AFDS) IN CCDT BUILDING AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
2024_MES_669788_1
8075/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM, Visakhapatnam
₹26,180
Yes
16 Nov 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
5 Oct 2024
16 Sept 2024
Amount
Supply of IP based wireless addressable fire detection & alarm panel with AC 220 volt input connectivity, LCD display with programming keys, addressable loop , inbuilt CMS (Central Monitoring System) facility, STQC (Govt. Of India) approved devices and CMS, built in auto dialler with voice help messages of 60 seconds, built in voice message announcement in case of alarm, integration to SCADA, OFC, LAN/ WAN for remote monitoring control, built in hooter on panel & built in battery back-up on panel board for 24 hours etc. all as specified and directed. Make :-MES approved Products in group-I.
Supply of wireless addressable smoke / heat detectors integrated in white plastic housing for fire information and operation, powered by standard lithium 3 volt battery, anti tamper proof protection features, In built sounder, concealed antenna within sensors, non-dip switch automatic programming with panel, tamper switch on base, automatic bi-directional communication by panel with devices and detectors, STQC (Govt. Of India) approved devices and CMS ,resetable through panel ,comply to EN45 Pt.25, IP operational etc, with all accessories all as specified and directed. Make :-MES approved Products in group-I.
Supply of addressable type beam detector having emitter, receiver assembly, reflector fixing accessories etc. complete all as specified and directed.
Supply of wireless addressable manual call point, integrated in red plastic housing with fire operational mark, bi-directional communication with panel and sensors, single action activation features, battery powered, resetable through keys, comply to EN45 Pt25., STQC (Govt. Of India) approved complete all as specified and directed. Make :-MES approved products in group-I .
Supply of wireless Indoor siren integrated in ABC module with adapter all as specified and directed.
Supply of wireless signal repeater with adapter all as specified and directed.
Supply of external strobe siren for panel all as specified and directed.
Supply of AC / DC operated LED sinage all as specified and directed.
Supply of IP CMS SCADA Station all as specified and directed.
Supply of IP CMS software suite all as specified and directed.
Testing , Installation & Commissioning charges all as specified and directed.
Evolution protocols, single area false alram amangement facility, provision of CMS/ Ad-Net software - to monitor & control the status of the FACP- with visual & sound alerts for the fire and fault conditions- with three level multi users access. inbuilt PSTN commuinicator for remote reporting of events with CMS. PC connectivity for system supervision and operations. 1. Provision of 24- volts fault torrent network card built in diagnostics and is fully monitored for both short and open circuit faults between nodes. (to be installed in fire alram panel). The maximum number of network nodes in 200. 2. Point wiring with one power socket with switch of 5 Amps. Make: Truesafe/ Apollo/ Cooper/ Notifier"
Supply, installation & testing and commissioning of GSM communicator which converts the contact ID codes of the fire alarm panel PSTN communicator for central alram monitoring: GSM communicator is special for converting the PSTN adecco contact ID codes to readable SMS notification and SIA-09 IP over GPRS network to central monitoring station (CMS). Available in 2G/3G/4G/LTE mobile network versions. Fire detection and alarm system ae to be connected with GSM module with 2/4G GSM version of 2G QUAD BADN (850/900/1800/1900 MHz) . Direct mount antenna with SMA male L-type connector -CDMA and WCDMA, 2.5 dBi gain and 850-2100/2400 MHz. IP communicator for fire alarm control panels, supports full transmision contact ID over IP SIA-DC09 event information to security monitoring station. 4/8 general alram inputs including power supply voltage monitoring via SMS messages, 800 remote control users via
free short call, 800 users control by GSM call or using maxim-Dallas I Button keys, configuration using standard mini-USB cable Remote configuration and firmware upgrade, Easy installation. and diagnostic of the module via USB by using program SOFTWARE, very useful features are troubleshooting and testing of the module via USB PC; this sves time for installer and allows real time monitoring of module parameters, input/output and GSM modem status (IMEI, SIM, registration) etc. Free configuration and diagnostic software, Free andoroid APP and WEB cloud service with software for Mobile/ Tab's/ PC's -1 set with each panel (Mobile/ Tab's/ PC's at extra cost). 2. Central alarm monitoring at security through cloud- based software (with out and ant receiver) with PC/TAB/ (PC/TAB at extra cost) Make: compatible with Apollo/ cooper / notifier/ honeywell protocol fire alarm panel as per international communication protocol standards
"Supply, installation and commissioning of addressable talentum dual IR (IR2) flame dectector, Hazardous Area Model - Intrinsically safe (IS) 16571: Die cast zinc alloy The requirements of Directive 94/9/EC, the atmosphere Expolsive ATEX Driective have been met. Apparatus Certificate Number: BAS02ATEX 1001 System certificate Number: Baseefa08Y0078 ExII 1G Ga Ex ia IIC T4 Zones 0,1, 2 Zone 0,1,2"
Supply and fixing of Multisensro (Heat & smoke) detector comprises optical smoke and thermistor temperature sensors which give both a combined singnal as well as separe heat singnal for improved false along with isolator modules as required. Positioning of multi sensor detectors as per area requirement. Functional testing of all multi sensors detectors as per area requirement. Functional testing of all multi sensors is required by all national standards around the world, including BS:5839, DIN 14675 and NFPA 72. A functional test should be carried out using can contains the test aerosol and appropriate TEST fire test tool whcih is designed for purpose and will cause no damage to the detector under test. Operating voltage: 17-28 V DC Communication protocol: Honeywell/ Notifier/ Apollo/ Series 90/XP95 5-9V peak to peak Quiescent current: 500 uA averange 750 uA peak Power - up surge current: 1mA
Maximum power -up time: 10s Alaram LDE current : 3.5 mA Remote LED current:4mA at 5V (measured across remote load) Celan air analogue value: 23+4/-0 Alaram level analogue value: 55 Alaram indicator: 2 colourless Light emitting Diodes (LEDs)' illuminated red in alaram optional remote LED Dimensions: 100 mm diameter 50mm height 58mm (height in base) Weight: Detector: 105g Detecor in base: 160 g materials: Housing: white polycarbonate V-o rated to UL94 terminals: Nickel plated stainless steel Smoke element only: chamber configuration: Horizontal optical bench housing infra- red emitter and sensor, arranged radially to detect forwared scattered light. Sensor: Silicon PIN photo- diode Make: Apollo./ cooper/ notifier
"Supply and fixing of loop sounder visual indicator are available when it is being controlled by the full core protocol with the fire control panel programmed accordingly. These are indentical to the sounder visual indicator base but eh open area sounder visual indicator is a wall mounted stand alone device that produces a higher sound output of up to 100dB (A). Make: Apollo/ Cooper/ Notifier"
Supply and fixing of addressable dual action manual pull station: the addressable manual pull station is a die-cast pull station used for a variety of applications focusing mainly on fire alarm systems. The pull station is a single action switch. The pull station has a 10 amps snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The manula pull station has a hex key rest. Make: Apollo/ Cooper/ Notifier
Supply and fixing 2 core 1.5 sqmm copper cable: 2 core, 1.5 Sqmm, through rigid PVC conduits, high conductivity annealed bare electrolytic copper conductor 650/1100 v grade, pvc insulated, pair twisted & screened, flexible, both inner and outer FR/FRLS PVC sheathed with proper pair identification. 1.2 strandard: As per IS 1554, part-I & IS 5831 latest and any other relevant. Make : Polycab/ KEI/ Havells
Supply and fixing of 20 sqmm, rigid PVC conduit inclusive of all the necessary fittings like Bends, Tee's Elblow on wall/ Trenches all as specified and directed. Make: Finolex/ Sudhakar/ Kalinga
Supply and fix voltage stabilzer for automatic operation, single phase naturally air- cooled indoor type & designed for input variation between 170V and 250V with output voltage stabilized at 230V with accuracy of 2.5 % and of capacity 2.0 KVA complete all as specified and directed.
SHIKHARA PROJECTS (BID ID -3103799)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .