Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹5.0 L+₹78,070 (18.3%)Accepted-Finance | L2 | Accepted-Finance Second Lowest Bidder |
Tender Value
₹4.7 L
EMD Value
₹9,500
Closing Date
14 Dec 2020, 2:00 pmClosed
Assistant Executive Engineer (Electrical)
Assistant Executive Engineer (Electrical),CSIR IHBT, Palampur (H.P.)
SITC of LT Panel and Cable to Enzyme Bioprocessing Facility
2020_CSIR_63975_1
5-226/Ws/20
Open Tender
Electrical Works
Works
30 days
CSIR-IHBT, Palampur
As per NIT and contract document
2 documents required · 2 mandatory
₹500
Director
₹9,500
15 Dec 2020
8 Dec 2020
15 Dec 2020
8 Dec 2020
14 Dec 2020
9 Dec 2020
8 Dec 2020 - 14 Dec 2020
Amount
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i)Above 185 sqmm and upto 400 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i)Above 185 sq.mm and up to 400 sq.mm(Clamped with 40 x 3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i) 3.5x 240 sq. mm (62mm)
Suppying & laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupler etc. conforming to IS 14930, Part II complete with fitting and cutting cutting, jointing etc. in the existing trench, complete as required. i) 160 mm Dia ( OD - 160 MM mm & ID 135 mm nominal)
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI/ Finolex) i) 3.5 core 240 sqmm
SITC of LT Panel (Manufactured by CPRI approved manufacturer), indoor type cubicle Panel, vermin proof, totally enclosed made out of 2.00 mm thick CRCA sheet steel machine pressed of suitable size, suitable to operate on 3 Phase 4 wire system with Phase Sequencing Facility, 415 volts, 50 Hz, Double door front and back openable with locking arrangement inc. frame of panel with angle iron of size 50 x 50 x 5 mm. Bottom gland plate in cable alley for incoming & outgoing cable of suitable size as per switchgear rating ( Main cable being 3.5 core 240 sqmm), having apron (1.6 mm )on 3 sides of panel from base to ground level incl cable alley on both sides complete duly powder coated with RAL 7032(PP Grade) 7 tank process comprising with following complete as specified: i) Bus Bar Strip, four Pole capacity 500 Amp. Aluminium strip of suitable size based on 1.0 Amp. per sqmm, coloured coated heat shrinkable sleeves , Panel will consist of : Incoming : a) MCCB 400 amp, 415 volts, 36 ka, 4 pole with adj. thermal magneic release (Inc. Spreader Terminal) = 01 No. b) Contactor MNX 400 (or Equivalent), 400 amp. = 02 No. c) On Delay Timer = 01 No. d) SM 175 Relay (or Equivalent) = 01 No. e) Bypass Changeover Switch 400 Amp = 01 No. f) multifunction metre with LCD display - 01 no. g) Indicator with neon lamps for RYB, 3 Phase = 01 Set Outgoing : a) MCCB 100 Amp., 415 V, 25 ka, 3 pole with adj thermal magnetic release (Inc. Spreader Terminal)= 04 No. b) MCCB 63 Amp, 415 V, 16 Ka, 3 pole with adj. thermal magnetic release = 07 no. c) Terminal Strips 63 Amp. = 07 Sets (MCCB & Contactor Make: Siemens/ ABB/ Legrand/ L&T ).
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment) Inernal work - Exposed on wall i) 22.22 mm outer dia Pipe
Providing and fixing S.S. Gate valve of approved quality conforming to IS:8931 i) 15mm nominal bore
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° i) For 22.22 mm outer dia pipe
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall i) 20 mm dia nominal bore
Pankaj Saini Govt Contracor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .