Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.2 LAccepted-AOC 164 MASJID BATI ROAD MILLAN NAGAR RATH TALA KANCHRAPARA NORTH 24 PGS | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | 1 | Accepted-AOC 1st Lowest | |
| 2 | 2₹34.9 L+₹69,048.50 (2.02%)Rejected-Finance 118 RAMESH GOSWAMI ROAD KANCHRAPARA NORTH 24 PGS | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743145 | 2 | Rejected-Finance 2nd Lowest | |
| 3 | 3₹35.2 L+₹1.0 L (3.03%)Rejected-Finance 43 NALINI BASU ROAD KANCHRAPARA NORTH 24 PGS | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | 3 | Rejected-Finance 3rd Lowest |
Tender Value
₹34.5 L
EMD Value
₹67,057
Closing Date
15 Jan 2026, 11:55 amClosed
Chairman, Kanchrapara Municipality
OFFICE OF THE BOARD OF COUNCILLORS Kanchrapara Municipality 42, Netaji Subhash Path. Kanchrapara, North 24 Parganas. Pin - 743145
Roof casting over existing bricks structure and renovated of boundary wall ground floor and first floor toilet block of Sahidnagar High School. P.O. Kanchrapara Dist. North 24 Parganas at Ward No 20 under Kanchrapara Municipality.
2025_MAD_978881_1
2861
Open Tender
CIVIL WORKS
Percentage
180 days
Kanchrapara Municipality
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,000
₹67,057
Kanchrapara Municipality
21 Jan 2026
24 Dec 2025
19 Jan 2026
24 Dec 2025
15 Jan 2026
24 Dec 2025
29 Dec 2025
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m a) In ground floor including roof.
For First Floor b) Extra rate for each addl. Floor over the rate ground floor Page No - 10, Item No - 1 (b) ; 50.00/Cum.
(c) Extra rate for careful dismantling and recovering at least 150 no of useable bricks per cum
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars (a) In ground floor including roof.
For First Floor b) Extra rate for each addl. Floor over the rate ground floor Page No - 10, Item No - 3 (b) ; 50.00/Cum.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Labour for scrapping and picking up old dilapidated mortar / plaster (Cement / Surki / Lime mortar) from the surface of old Brick faces ncluding cleaning the frog without damaging the Brick and stacking the Bricks at Site / Stacking yard as per direction of Engineer-in-charge including removing all debris rubbish from site complete.
Labour for breaking 1/2 Bricks or Full Bricks (Old / New) into metal / Khoa / chips as per specific size and stacking the same at site or stackyard with due allowance of sinkage / shrinkage as per direction of the Engineer in charge. (b) Khoa Size 32 mm to 25 mm
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Post Constructional Measures : (a) Post construction measures: Anti-termite treatment to the outside of foudations with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (62ml in 28.5litres) with including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 5.3.1.1 of code IS-6313 (Part-III):2013.
(b) Anti-termite treatment to the outside of foundation with chemical emulsion by admixing Imidacloprid emulsifiable concentrate (62ml in 28.5litres) with water by weight, drilling 12mm. dia holes in concrete or masonry appron at an interval of 300mm. to a depth, of 300mm or more as close to the plinth wall as possible and the chemical emulsion pumped into those holes to suok the soil below at a rate of 2.25 litres per linear metre complete as per specification laid down in para 5.3.1.2 of Code I.S.-6313 (Part-111)-2013.
(c) Anti-termite treatment to the soil under floor with chemical emulsion by admixing Imidacloprid emulsifiable concentrate (72ml in 34litres)with water by weight including drilling vertically 12mm dia. holes at the junction of floor and wall at 300mni, interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor, The entire work is to be carried out as per specification laid down at table 1 & in para 5.3.1.3 of Code 1.S.-6313 (Part-111)-2013.
d) Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (42ml in 20litres) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m.dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at teh rate of half litre per hole. The entire work is to be carried out as per specification of in table 1 & para 5.3.1.3 of Code I.S.-6313 (Part-III)-2013. The shutters are to be sprayed with emulsion, on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, preading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion
Brick work with 1st class brick in Cement mortar (6:1) In foundation and plinth
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed
Brick work with 1st class brick in Cement mortar (6:1) (b) In superstructure, ground floor
For First Floor Page No - 16, Item No - 14 ; 111.00/m³
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
For First Floor Page No - 18, Item No - 26 ; 12.00/m²
For Second Floor Page No - 18, Item No - 26 ; 12.00/m²
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge
For First Floor Page No - 42, Item No - 36 (d) ; 18.00/m²
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, inders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m II. Other than SAIL/ TATA/RINL
For First Floor Page No - 44, Item No - 40 (b) ; 48.00/Qntl.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety
For First Floor Page No - 35, Item No - 23 ; 95.00/m³
Labour for Chipping of concrete surface before taking up Plastering work.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps (c) Sal : Siliguri.
For First Floor Note: Extra for Lifting Charges for each additional floor, Page No - 114 ; i) Rs. 200/- per Cu.m (upto 4th floor)
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (a) 40mm X 6mm, 250mm Length
(b) 40mm X 6mm, 200mm Length
Z-batten shutters of door and window as per design havings tongued and groovehalf lap jointed as per direction of the Engineer-in-Charge including fitting and fixing shutter in position, but excluding the cost of hinges and other fittings in ground floor (B) Shutter with 19mm thick planks, 19mm thick battens. (iii) Sishu, Gamar, Champ, Badam, Bhola, Morga, Hallak.
For First Floor Note: i) Lifting Charges for upper floors refer item H (2). Page No - 182, Item No - 2 ; 29.00/m²
PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete.
For First Floor Note: (For upper floors refer to item H(4) also) Page No - 182, Item No - 4 ; 14.00/m²
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISmark. (vi) 100mm. X 50mm. X 1.25mm.
(iii) 75mm. X 40mm. X 1.12mm.
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (b) 250mm long.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (vii) 225mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (ii) 100 mm grip x 10 mm dia rod.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) (ii) With 1:4 cement mortar (c) 10 mm thick plaster
For First Floor Page No - 193, Item No - 1 ; 4.00/m²
i) With 1:6 cement mortar (b) 20 mm thick plaster
For First Floor Page No - 193, Item No - 1 ; 4.00/m²
i) With 1:6 cement mortar (c) 15 mm thick plaster
For First Floor Page No - 193, Item No - 1 ; 4.00/m²
For Second Floor Page No - 193, Item No - 1 ; 4.00/m²
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (ii) 25 mm. thick
For First Floor Add extra @1.5% for each addl. floor upto 4th floor Page No - 48 ; 273.00 X 1.50% = 4.09/m²
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
For First Floor Page No - 65 ; 5.00/m² (upto 4 th floor)
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
For First Floor Page No - 65 ; 5.00/m² (upto 4 th floor)
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and m+C185anufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Without integrated grills. (a) Fixed type steel windows as per IS sizes with horizontal glazing bars
For First Floor Add extra @ 1.2 % for each additional floors upto 4th floor Page No - 107 ; 1508.00 X 1.2% = 18.09/m²
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
For First Floor Add extra @ 1.2 % for each additional floors upto 4th floor Page No - 104, Item No - 13 ; 9888.00 X 1.0% = 98.88/Qntl.
(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars.
For First Floor Add extra @ 1.2 % for each additional floors upto 4th floor Page No - 107 ; 2199.00 X 1.2% = 26.38/m²
(iv) Two point nose steel handle including fitting and fixing.
(vi) steel peg stay 300 mm long including fitting and fixing.
Supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per IS:12866-1989 (a) 1.2 mm thick (1.85 Kg/Sq.m)
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
For First Floor Add extra @ 1% for each addl. floor upto 4th floor Page No - 106 ; 4330.00 X 1.0% = 43.30/m²
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white)
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats
For First Floor Page No - 198, Item No - 1 ; 0.71/m²
For Second Floor Page No - 198, Item No - 1 ; 0.71/m²
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
For First Floor Page No - 198, Item No - 1 ; 0.71/m²
For Second Floor Page No - 198, Item No - 1 ; 0.71/m²
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Painting black board with approved paint after scraping and polishing surface etc.
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm. dia rod complete including mending damages. Payment for damage and repair to be made separately.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 25 mm Dia.
20 mm Dia.
(b) For Concealed Work 15 mm Dia.
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (vii) 25 mm dia
(viii) 20 mm dia
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii) Plastic (hallow type) white
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia (iii) 600 mm long
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing soap holder. (b) Fibre glass
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
(b) Extra for each additional story
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (ii) 470 mm X 280 mm X 340 mm
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (i) 450 mm X 350 mm
Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete (i) 600 mm X 100 mm (a) Salt glazed stone ware
Cutting hole through wall, roof or cornice and mending good all damages.
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm
(A) (i) Single Socketed 3 Meter Length (c) 160 mm
(B) Fittings (ii) Plain Tee (b) 110 mm
(iii) Door Tee (c) 160 mm
v) Plain Y (b) 110 mm
x) Bend 87.5º (b) 110 mm
xi) Door Bend (T.S.) (c) 160 mm
xv) Vent Cowl b) 110 mm
xvi) Pipe Clip b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (A) Above ground (ii) 110 mm dia.
Supplying, fitting and fixing C.I. round grating. (ii) 150 mm
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety (Other than SAIL/TATA/RINL).
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (Other than SAIL/TATA/RINL)
Glow sign board Name and contact details of the following are displayed prominently - Name identification and name of School under whose jurisdiction
Less brick for old construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.97 MB
BOQ_2385624.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .