Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹24.5 LAccepted-AOC 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹24.5 L Quoted ₹32.7 L | L3 | Accepted-AOC Being lowest bidder |
| 2 | L1₹24.5 LRejected-Finance | ₹24.5 L | L1 | Rejected-Finance Not Lowest Bidder |
| 3 | L2₹28.4 LRejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹28.4 L | L2 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S NRS TIIB AND CO L2 | SANJEEV ENTERPRISES L3 | PANWAR ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Attending complaints of EOT/HOT crane installed at AFS Ambala of capacity 0.5/1.0/2.0/2.5/5/10 Tonne, complaint of any nature on emergency call given by concern Engineer-in-charge/JE, by providing skilled service engineer/ mechanic for locating the electrical and mechanical fault and rectification of the fault within two day to the entire satisfaction level of the Engineer-in-charge complete all as specified & directed.
Notes:- (i) Taking out / down of unserviceable spare parts and Supply and fixing of new spare parts required for rectification of fault shall be measured and paid separately.
(ii) The complaints shall be attended by the contractor within 48 hours. A penalty of Rs. 500/- per hour will be recovered/made for not attending the complaint/non rectification of fault beyond 48 hours upto 72 hours, after intimation of concerned AGE/JE in writing. A penalty of Rs. 12000/- per day (for every 24 hours) will be made for not attending the complaint beyond 72 hours.
(iii) The contractor will be responsible for providing T&P to the personal deployed, as per requirements for rectifying the fault(s).
(iv) If the nature of fault for which rectification is involved comes beyond the scope of contract, the same shall not be considered for any type of penalty. Decision of GE in this regard shall be final & binding.
(v) Site visit by the contractor /service engineer / mechanic for any number of time requierd to make EOT crane serviceable condition /upto satisfaction of user will be considered only one job, cost of this aspect deemed to be included in quoted rates.
(vi) Any minor parts which is not included in BOQ here-in-after but required for satisfactory operation of EOT crane deemed to be included in quoted rates. | 38 | Each Job | 2,850 ₹1.1 L | 4,000 ₹1.5 L | 3,000 ₹1.1 L |
| 2.00 | Servicing of electrically operated over head travelling cranes (EOT) double girder type (Flame proof ) of 10.0 tonne capacity installed at Baknaur comprising of electric motor for long travel, cross travel, hoist motion, VVVF Drive and electric control panel consisting of MCCBs/main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed. | 4 | Each Job | 24,250 ₹97,000 | 26,500 ₹1.1 L | 22,000 ₹88,000 |
| 3.00 | Servicing of electrically operated over head travelling cranes (EOT), double girder type (Normal / Flame proof ) of 5.0 tonne capacity installed at Ambala comprising of electric motor for long travel, cross travel, hoist motion, VVVF Drive and electric control panel consisting of MCCBs /Main switches , step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed. | 7 | Each Job | 17,000 ₹1.2 L | 17,000 ₹1.2 L | 16,000 ₹1.1 L |
| 4.00 | Servicing of electrically operated over head travelling cranes flame proof type (EOT), double girder type of 3.0/2.5 tonne capacity installed at WWR Bldg in BD-I comprising of electric motor for long travel, cross travel, hoist motion, creeping micro speed and electric control panel consisting of MCCBs /Main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables, etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed.. | 7 | Each Job | 11,750 ₹82,250 | 13,000 ₹91,000 | 11,000 ₹77,000 |
| 5.00 | Servicing of electrically operated over head travelling cranes (EOT), double girder type(Normal/Flame proof) of 0.5/1.0/2.0 tonne capacity installed at MMPU & RSM Bldgs Technical Storage Buildings, compressed gases yard comprising of electric motor for long travel, cross travel, hoist motion, creeping micro speed and electric control panel consisting of MCCBs /Main switches , step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables, etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed.. | 32 | Each Job | 9,200 ₹2.9 L | 10,000 ₹3.2 L | 8,500 ₹2.7 L |
| 5.01Notes for BOQ item No. 2.00 to 5.00:- (i) Taking out / down of unserviceable spare parts are included in quoted rates and Supply and fixing of new spare parts shall be measured and paid separately . (ii) The servicing of each crane throughout the contract period shall be responsibilty of contractor and shall quote accordingly. (iii) The record of servicing shall be maintained by the contractor and shall be produced at the time of payment duly signed by the Users, Engineer-in-charge & contractor . (iv) The following parts (to be checked) included in the quoted rates :- (a) Motors- Check terminal connections slip rings, carbon bushes alignment of motors, couplings, clutches, brakes if any tight/adjust if required. (b) Wire Rope – Check lubrication and number of broken wires. (c) Hook – Check for free rotation of hook, lubrication/ greasing/ oiling of moving parts. (d) Electrical – Check contactor tips limit switch operating mechanism including connections & testing of LT panel of crane complete. (e) Cleaning of all parts and rail/wheel of cranes. (f) Checking of all movement i.e Long Travel, Cross travel, lifting and/or any other part(s) as decided by the GE/Engineer-in-charge. (v) Detection of oil leakage rectification of the same along with replacement of oil seal demeed to included in quoted rates. | ||||||
| 6.00 | Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 10 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed. | 4 | Each Job | 9,500 ₹38,000 | 10,000 ₹40,000 | 9,000 ₹36,000 |
| 7.00 | Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 5 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed. | 7 | Each Job | 9,200 ₹64,400 | 10,000 ₹70,000 | 9,000 ₹63,000 |
| 8.00 | Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 2.5/3.0 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed. | 7 | Each Job | 7,500 ₹52,500 | 9,500 ₹66,500 | 7,000 ₹49,000 |
| 9.00 | Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 2.0/1.0/0.5 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed.
Notes for BOQ item No. 6.00 to 9.00: -
(i) The arrangement of load for load testing and shifting arrangements of load from any distance shall be made by the contractor and quoted rates are deemed to be included for this aspect.
(ii) The load testing for LT/CT/hoist motion shall be done in the presence of Users and JE .
(iii) A performa for load testing of each crane shall be maintained and all the parameters mentioned in the performa shall be tested by the contractor and the record of load testing shall be maintained,duly signed by all concern. | 32 | Each Job | 7,200 ₹2.3 L | 8,500 ₹2.7 L | 6,500 ₹2.1 L |
Updated dates
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
7 Jan 2026, 6:00 pmClosed
CWE (AF) Ambala
HQ CWE (AF) Ambala
COMPREHENSIVE MAINTENANCE OF EOT HOT CRANES AND CONNECTED ITEMS INSTALLED IN VARIOUS LOCATIONS OF TECH AREA AT AF STN AMBALA AND BAKNAUR UNDER GE AF AMBALA
2025_MES_742009_1
CWE/AF AMB/AMB-47/2025-26
Open Tender
Civil Works
335 days
Ambala Cantt
For MES enlisted contractor Class D Category b ii and for un-enlisted contractor
refer NIT
8 documents required · 8 mandatory
₹500
GE (AF) Ambala
₹58,000
Yes
25 Mar 2026
28 Nov 2025
9 Jan 2026
28 Nov 2025
7 Jan 2026
24 Dec 2025
28 Nov 2025 - 10 Dec 2025
Amount
Servicing of electrically operated over head travelling cranes (EOT) double girder type (Flame proof ) of 10.0 tonne capacity installed at Baknaur comprising of electric motor for long travel, cross travel, hoist motion, VVVF Drive and electric control panel consisting of MCCBs/main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed.
Servicing of electrically operated over head travelling cranes (EOT), double girder type (Normal / Flame proof ) of 5.0 tonne capacity installed at Ambala comprising of electric motor for long travel, cross travel, hoist motion, VVVF Drive and electric control panel consisting of MCCBs /Main switches , step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed.
Servicing of electrically operated over head travelling cranes flame proof type (EOT), double girder type of 3.0/2.5 tonne capacity installed at WWR Bldg in BD-I comprising of electric motor for long travel, cross travel, hoist motion, creeping micro speed and electric control panel consisting of MCCBs /Main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables, etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed..
Servicing of electrically operated over head travelling cranes (EOT), double girder type(Normal/Flame proof) of 0.5/1.0/2.0 tonne capacity installed at MMPU & RSM Bldgs Technical Storage Buildings, compressed gases yard comprising of electric motor for long travel, cross travel, hoist motion, creeping micro speed and electric control panel consisting of MCCBs /Main switches , step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables, etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed..
Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 10 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed.
Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 5 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed.
Material and labour for static & dynamic load testing, health inspections of complete cranes capacity 2.5/3.0 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed.
Material and labour brake adjustment of any crane of any capacity including load testing in presence of user / JE complete all as specified & directed.
Supply and fixing as in replacement timer relay, encapsulated on delay Timer Type SAS-P (Solid State output) Voltages : 240 volt AC, 110volt AC, 48volt AC/DC, 24volt AC/DC, Time Range : 1 second or 0.1-10 Second or 1-100 Second or 3-300 Second complete all as specified and as directed.
Supply and fixing in repair 160mm dia Flameproof Thrustor Operated Brake (Type "FLPMTOB" ) with 18Kg Flameproof Thrustor Type 'ETF-240' suitable for Gas Group-IIB, Zone-1&2, as Per IS:2148, 415 volt AC, 3 Phase, 50 Hz, Braking Torque 9 Kg-mtr complete all as specified & directed
Supply and fixing in repair 100mm dia Flameproof Thrustor Operated Brake (Type "FLPMTOB" ) with 18Kg Flameproof Thrustor Type 'ETF-240' suitable for Gas Group-IIB, Zone-1&2, as Per IS:2148, 415 volt AC, 3 Phase, 50 Hz, Braking Torque 6 Kg-mtr complete all as specified & directed
Supply and fixing in repair 160mm dia ,Thrustor Operated Brake (Type "MTOB" ) with 18Kg Thrustor Type ' ET-240' 415 volt AC, 3 Phase, 50 Hz, Braking Torque 9 Kg-mtr complete all as specified and as directed
Supply and fixing in repair 100mm dia ,Thrustor Operated Brake (Type "MTOB" ) with 18Kg Thrustor Type ' ET-240' 415 volt AC, 3 Phase, 50 Hz, Braking Torque 6 Kg-mtr complete all as specified and as directed
Supply and fixing in repair 160 mm dia brake lining of electromagnetic thruster 160 FLP complete all as specified & directed.
Supply and fixing in repair 100 mm dia brake lining of electromagnetic thruster 100 FLP complete all as specified & directed.
Supply and fixing in repair brake shoe thrust assembly with lining set 415 volt AC, 3 phase 50 Hz fill with transformer oil EHD grade 'B' class suitable for main hoist and for vertical drive of size 1.0/2.0 ton capacity complete all as specified & directed.
Supply and fixing in repair brake shoe thrust assembly with lining set 415 volt AC, 3 phase 50 Hz fill with transformer oil EHD grade 'B' class suitable for main hoist and for vertical drive of size 2.5 ton capacity complete all as specified & directed.
Supply and fixing push button for moveable pendant and making necessary connections including testing complete fixed as in repair all as specified & directed.
Supply and fixing emergency stop switch for flame proof pendant and making necessary connections including testing complete fixed as in repair all as specified & directed.
Supply and fixing contactor 3 pole, 415 volts, 32 Amps complete fixed as in repair all as specified & directed.
Supply and fixing contactor 3 pole, 415 volts, 25 Amps complete fixed as in repair all as specified & directed.
Supply and fixing contactor 3 pole, 415 volts, 18 Amps, type ML 0 complete fixed as in repairall as specified & directed.
Supply and fixing HRC fuse 5 Amp to 16 Amp capacity complete fixed as in repair all as specified & directed.
Supply and fixing HRC fuse 20 Amp to 32 Amp capacity complete fixed as in repair all as specified & directed.
Supply and fixing HRC fuse 40 Amp to 63 Amp capacity complete fixed as in repair all as specified & directed.
Supply and fixing in replacement MCB, three pole and neutral, 415 volts, 40 Amps, 16 KA complete all as specified & directed.
Supply and fixing in replacement MCB, 5 to 32 Amps, SPN, C curve type, 240 volts, 10 KA, finger proof terminals, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB/Panel complete all as specified & directed.
Supply and fixing in replacement MCB, 5 to 40 Amps, SP, C curve type, 240 volts, 10 KA, finger proof terminals, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB/Panel complete all as specified & directed.
Supply and fixing single phase preventer complete fixed as in repair all as specified & directed.
Supply and fixing over load relay, Built-in Single Phasing protection, mounting type capacity 12-24 Amps complete fixed as in repair all as specified & directed
Supply and fixing thermal over load relay, Built-in Single Phasing protection mounting type capacity 6-12 Amps complete fixed as in repair all as specified & directed
Supply and fixing thermal over load relay, Built-in Single Phasing protection, mounting type capacity 2-5 Amps complete fixed as in repair all as specified & directed
Supply and fixing breaking resister 1500 Watt, 1 Ohm to 5 Kilo-Ohm for 2 HP Motor capacity complete fixed as in repair all as specified & directed.
Supply and fixing breaking resister 2000 Watt, 1 Ohm to 5 Kilo-Ohm for 3 HP Motor capacity complete fixed as in repair all as specified & directed.
Supply and fixing breaking resister 3000 Watt, 1 Ohm to 5 Kilo-Ohm for 5 HP Motor capacity complete fixed as in repair all as specified & directed.
Supply and fixing flame proof limit switch, 40 amps rating with one NO & one NC for long travel & cross travel complete fixed as in repair all as specified & directed.
Supply and fixing flame proof limit switch, 40 amps rating with rotory gear of main hoist complete fixed as in repair all as specified & directed.
Supply and fixing variable speed drive 3 Phase, 415 volt, 4KW, 5HP suitable for motor installed on EOT Crane with overvoltage protection, undervoltage protection, overcurrent protection and short circuit protection and making necessary connections including testing complete all as specified & directed
Supply and fixing flame proof pendant suitable for 0.5/1.0/2.0/2.5/3.0/5.0/10.0 ton capacity gantry complete all as specified & directed.
Supply and fixing in repair non flame proof pendant suitable for 0.5/1.0/2.0/2.5/3.0/5.0/10.0 ton capacity gantry complete all as specified & directed
Supply and fixing in replacement wheel bearing size 6207 complete all as specified & directed.
Rewinding of motor capacity 2 HP/3 HP, 415 volt, 3 phase with super enameled copper conductor as per existing weight, size and design etc. varnishing, baking and testing including taking down unserviceable / wornout winding of flame proof / non flame proof motor mounted on rail complete all as specified & directed.
Supply and fixing in replacement control cable, 1.5 sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
Supply and fixing in replacement control cable, 2.5 sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
Supply and fixing in replacement control cable, 4.0 sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
Supply and fixing in replacement control cable, 1.0 sqmm 16 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
Supply and fixing in replacement control cable, 1.0 sqmm 19 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
Taking down/out travelling crab of double girder 2.5 / 2.0 tonne capacity, electric operated crane for rectification of fault and re-installing with and including replacing testing complete all as specified & directed.
Dismantling & taking out of gear box of EOT grantry 10000/5000/3000/2500/2000/1000/500 Kg capacity, for rectification of fault & re-installing the same including replacing of unserviceable bearing, bush, gears of existing make and size including turning, welding, grinding and testing complete all as specified & directed.
Opening of gear box of EOT crane capacity 0.5/1.0/2.0/2.5/3.0 ton ,tracing fault of oil leakage, rectifying the same with and including replacement of oil seal/gasket to make it functional complete all as specified & directed.
Supply and fixing in replacement bearing block of existing make & size at site complete all as specified & directed.
Dismantling of unserviceable rotating shaft & keyways from travelling crab and transporting to & fro to workshop for checking & repairing and making new keyways including inserting new key as per existing/site requirement for fully functional of EOT crane complete all as specified & directed.
Material and labour checking electric circuits of any EOT crane and locating the fault, rectifying the fault and replacing the unserviceable parts if required and ensuring furntionality of EOT cranes including replacement of burnt/wornout wires complete all as specified & directed Note: Spare parts to be measured and paid seperately.
Material and labour in replacement of cable roller with superior quality plastic roller to the existing cable complete all as specified & directed
Supply and fixing Rotary Geared Shunt limit switch with 2NC contact and gear ratio 48:1, contactor rated 40 Amps, 415 volt AC complete all as specified & directed.
Supply and fixing Two way lever type Shunt limit switch with 3NC contact and contact rated for 40 Amps at 415 volt AC complete all as specified & directed.
Supply and fixing Variable Voltage Variable frequency Drive (VVVFD) 3 Phase, 415 Volt, 5.5KW for electric crane complete all as specified & directed.
Supply and fixing in replacement steel wire rope 12mm dia, rope 6x36 construction, tensile grade 1770 Newton-Sqmm confirming to IS 2266/2002 with suitable size 'D' clamp, nuts, bolts and washers complete all as specified & directed.
Supply and fixing in replacement steel wire rope 10mm dia, rope 6x36 construction, tensile grade 1770 Newton-Sqmm confirming to IS 2266/2002 with suitable size 'D' clamp, nuts, bolts and washers complete all as specified & directed. Note for BOQ item No. 61.00 & 62.00: The Nut, Bolt, washer shall be mesured & paid seperately.
Material and labour applying two coat of epoxy paint by spray painting machine on site including preparation of rusted surface of gantry crane any type & capacity and writing SM No./MES No. complete all as specified & directed
Supply and fixing in repair hexagonal or square nuts, bolts with hexagonal or square heads at one end and screwed the other or screwed both ends and washers of any size any type complete all as specified & directed
Supply only gear oil, crane duty, helical gear box oil as per OEM recommendation complete all as specified & directed
Supply only synthetic gear oil VG680 for hoist thrust brake complete all as specified & directed
Supply only semi synthetic gear oil EP320 for gear box complete all as specified & directed
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum.
M/S NRS TIIB AND CO (BID ID -3510834)
SANJEEV ENTERPRISES (BID ID -3512160)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender47.pdf
Tender Documents • 0.45 MB
BOQ_830886.xls
BOQ • 1.06 MB
Download all tender documents and submit your bid