Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹2.7 L
Closing Date
29 Dec 2025, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. Meaning of Similar nature of work :'" " Any Signalling Work or any Telecom Work"
38 conditions · 32 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. Meaning of Similar nature of work : "Any Signaling Work or any telecom Work "
S&T Associated works in c/w safety and replacement work of various signaling assets in DSTE/MTD section of Jodhpur Division of NW Railway
SNT-JU-21-2025-26~NWR
SNT-JU-21-2025-26
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹2.7 L
29 Dec 2025
3 Dec 2025
15 Dec 2025
71 items across 1 schedule · ₹2,03,48,899.89 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 12F/4B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDE"". Inspection authority:- RDSO Inspection charges:- Bornee by Railways Payment Terms:- 100% after supply. | Numbers 150.00 | — | 3,943.56 | 5,91,534 | |
| 2 | Supply of Q-Series Neutral Line Relay (QN1 Type ), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDF"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers 150.00 | — | 3,789.37 | 5,68,405.5 |
| 3 | Supply of Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 8F/6B, 24V DC complete with plug board(base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABCEG"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers 100.00 | — | 5,426.82 | 5,42,682 |
| 4 | Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S- 76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Kilometre 10.00 | — | 5,813.26 | 58,132.6 |
| 5 | Supply of 1 x 6 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 84 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply | Metre 500.00 | — | 36.37 | 18,185 |
| 6 | Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 500.00 | — | 57.53 | 28,765 |
| 7 | Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 1 2 7 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply | Metre 500.00 | — | 99.45 | 49,725 |
| 8 | Supply of 1 x 25 Sqmm (Red/Black) multi strand copper power wire as per IS:694:2010 or latest, 197 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 500.00 | — | 155.29 | 77,645 |
| 9 | Supply of 1 x 35 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 277 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 2000.00 | — | 176.93 | 3,53,860 |
| 10 | Supply of Powder Coated Relay Racks as per Drg.No.CSTE/ NWR/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be supplied & completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200-Way tag blocks with poly carbonate covers, grouting bolts, tripods etc. It includes supply of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA- 24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 10.00 | — | 46,394.04 | 4,63,940.4 |
| 11 | Erection of Powder Coated Relay Racks as per Drg.No.CSTE/ NWR/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200- Way tag blocks with poly carbonate covers, grouting bolts, tripods etc. It includes fixing of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. After installation of relay racks, one coat of paint will be done by contractor before fixing the fuses. Scaffolding should include 1 relay rack position as spare at every Station/ Level Crossing Gate for future expansion. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on execution | Numbers 8.00 | — | 11,598.51 | 92,788.08 |
| 12 | Supply of round head type non- deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 2/4/6/10A/16A/20A Amp. (material will be supplied only from approved vendors of RDSO). Inspection: Consignee Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers 1000.00 | — | 54.64 | 54,640 |
| 13 | Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) | Numbers 3000.00 | — | 54.63 | 1,63,890 |
| 14 | Supply of End plate for item 4.28(i) of Chapter 4 of revised SOR 2.5mm/0.091 in thick as per site requirement. | Numbers 400.00 | — | 10.24 | 4,096 |
| 15 | Supply of End Stopper for item 4.28(i) of Chapter 4 of revised SOR 10mm/0.0394 in width as per site requirement. | Numbers 400.00 | — | 10.24 | 4,096 |
| 16 | Supply of Carrier Rails for item 4.28(i) of Chapter 4 of revised SOR 35mm x 7.5mm, 1mm/0.039 in thickness un- slotted type as per site requirement. | Metre 200.00 | — | 106.98 | 21,396 |
| 17 | Supply of Markers strip for item 4.28(i) of Chapter 4 of revised SOR | Numbers 1000.00 | — | 15.93 | 15,930 |
| 18 | Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 32 nos. of external Non Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Inspection:(i) RDSO/RITES: if value of item in work more than 5 lakhs (ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy. Inspection charges:(i)Borne by Railways (ii) None Payment Terms: 100% after supply. (Per Unit should be read as Per Module) | Per Unit 60.00 | — | 29,277.62 | 17,56,657.2 |
| 19 | Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 24 nos. of external Non Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. Inspection: (i) RDSO/RITES: if value of item in work more than 5 lakhs (ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy. Inspection charges: (i)Borne by Railways (ii) None Payment Terms: 100% after supply. (Per Unit should be read as Per Module) | Per Unit 8.00 | — | 48,285.03 | 3,86,280.24 |
| 20 | Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. Inspection: Consignee Inspection charges: None Payment Terms: 100% on commissioning(Per Unit should be read as Per Module) | Per Unit 68.00 | — | 885.44 | 60,209.92 |
| 21 | 2V, 80 AH | Numbers 800.00 | — | 2,067.93 | 16,54,344 |
| 22 | 2 V, 200 AH | Numbers 180.00 | — | 5,665.46 | 10,19,782.8 |
| 23 | 2V, 300AH | Numbers 180.00 | — | 7,059.56 | 12,70,720.8 |
| 24 | 2V, 500AH | Numbers 120.00 | — | 11,251.7 | 13,50,204 |
| 25 | 2V 80AH | Numbers 800.00 | — | 371.02 | 2,96,816 |
| 26 | 2V 200AH | Numbers 180.00 | — | 985.59 | 1,77,406.2 |
| 27 | 2V 300AH/ 500 AH | Numbers 600.00 | — | 986.73 | 5,92,038 |
| 28 | Supply of Class 'C' Type lightening cum Surge protection safety device with visual indication and potential free contacts output suitable for 110V AC application as per RDSO/SPN/172/2001 or latest. It also include transparent enclosed box. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 5.00 | — | 2,293.27 | 11,466.35 |
| 29 | Supply of Class 'D' Type lightening cum Surge protection safety device with visual indication and potential free contacts output suitable for 110V DC application as per RDSO/SPN/172/2001 or l a t e s t . It also include transparent enclosed box. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 5.00 | — | 4,838.06 | 24,190.3 |
| 30 | Supply of Class 'D' Type lightening cum Surge protection safety device with visual indication and potential free contacts output suitable for 60V DC application as per RDSO/SPN/172/2001 or latest. It also include transparent enclosed box. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 5.00 | — | 4,838.06 | 24,190.3 |
| 31 | Supply of Class 'D' Type lightening cum Surge protection safety device with visual indication and potential free contacts output suitable for 24V DC application as per RDSO/SPN/172/2001 or l a t e s t . It also include transparent enclosed box. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 5.00 | — | 5,413.94 | 27,069.7 |
| 32 | Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | Numbers 30.00 | — | 4,505.12 | 1,35,153.6 |
| 33 | Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the agles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 100.00 | — | 1,778.4 | 1,77,840 |
| 34 | Provision/Installation of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. | Numbers 2000.00 | — | 179.82 | 3,59,640 |
| 35 | Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 50.00 | — | 257.21 | 12,860.5 |
| 36 | Supply of hand operated track drilling machine for bonding hole. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply. | Numbers 10.00 | — | 8,051.14 | 80,511.4 |
| 37 | Supply of Different warning Boards / Calling on Board used for Railway Signalling system as per RDSO Drg. No. SA2380 (Adv). This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Numbers 50.00 | — | 4,637.76 | 2,31,888 |
| 38 | Supply of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient nos. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient nos. of programmable relay control for controlling AHU's, pressurisation fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply. | Numbers 1.00 | — | 50,166.35 | 50,166.35 |
| 39 | Supply of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All i t e m s as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest. Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply. | Numbers 40.00 | — | 2,737.45 | 1,09,498 |
| 40 | Supply of Analogue Addressable Manual Call Point with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, Electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply. | Numbers 15.00 | — | 2,865.44 | 42,981.6 |
| 41 | Supply of Linear Heat Sensing (LHS) c a b l e as per RDSO Specification No. RDSO/ SPN/ 217/ 2018 ver 2.0 or latest Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply. | Metre 400.00 | — | 599.26 | 2,39,704 |
| 42 | Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30) ° to (50) ° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 40.00 | — | 5,301.7 | 2,12,068 |
| 43 | Supply of Apparatus Case Single(Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 20.00 | — | 14,945.53 | 2,98,910.6 |
| 44 | Installation of Apparatus Cases Single(Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 20.00 | — | 1,039.09 | 20,781.8 |
| 45 | Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 10.00 | — | 9,439.4 | 94,394 |
| 46 | Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder , switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 10.00 | — | 632.78 | 6,327.8 |
| 47 | Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | Numbers 20.00 | — | 6,888.92 | 1,37,778.4 |
| 48 | Half (Medium) Case Apparatus case / SS location box as per Drg No CSTE/5074 | Numbers 10.00 | — | 5,259.16 | 52,591.6 |
| 49 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 30.00 | — | 9,563.45 | 2,86,903.5 |
| 50 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 12 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 10.00 | — | 4,855.13 | 48,551.3 |
| 51 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 5.00 | — | 4,648 | 23,240 |
| 52 | Single Case (Large Case) | Numbers 20.00 | — | 2,344.49 | 46,889.8 |
| 53 | Half Case (Medium Case) | Numbers 10.00 | — | 684 | 6,840 |
| 54 | Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.(Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 500.00 | — | 12.52 | 6,260 |
| 55 | Cable Size 6C x 1.5 Sq. mm. | Numbers 20.00 | — | 3,506.49 | 70,129.8 |
| 56 | Cable Size 12C x 1.5 Sq. mm. | Numbers 40.00 | — | 4,879.03 | 1,95,161.2 |
| 57 | Cable Size 30C x 1.5 Sq. mm. | Numbers 10.00 | — | 12,560.07 | 1,25,600.7 |
| 58 | Tools for installation of Rapid Cable Joint kit. | Numbers 15.00 | — | 5,201.12 | 78,016.8 |
| 59 | Supply of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with coupling on culverts bridges as per Drg.No.CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Metre 60.00 | — | 760.66 | 45,639.6 |
| 60 | Horizontal direction drilling/boring without damage of surface road /track using Auger Machine(HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This include insertion of different dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Metre 1500.00 | — | 1,202.97 | 18,04,455 |
| 61 | Horizontal Drilling by using manual pushing method at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge .Pipe Supply is not covered under this item Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Metre 400.00 | — | 122.74 | 49,096 |
| 62 | Transferring of Signaling/Telecom cables from existing Location box to New Location box . The work include breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc.The material required to dressing /lacing will be arranged by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Numbers 100.00 | — | 361.92 | 36,192 |
| 63 | Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Kilometre 5.00 | — | 6,860.47 | 34,302.35 |
| 64 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | cum 3000.00 | — | 274.28 | 8,22,840 |
| 65 | Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | cum 100.00 | — | 274.28 | 27,428 |
| 66 | Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground can not be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small.In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | cum 100.00 | — | 503.04 | 50,304 |
| 67 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution(unit is RM running meter) | Metre 10000.00 | — | 9.1 | 91,000 |
| 68 | Supply of Earth Leakage Detector (ELD) 12 Channels as per RDSO Specn.RDSO/SPN/256/2002 or latest. Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply. | Numbers 12.00 | — | 1,58,443.22 | 19,01,318.64 |
| 69 | Wiring, installation, testing and commissioning of Earth Leakage Detector (ELD) 12 Channels as per RDSO Specn.RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming power supply wires. On job training at site will be given by OEM engineer for installation and maintenance of ELD. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. | Numbers 12.00 | — | 39,610.81 | 4,75,329.72 |
| 70 | Supply of Vacuum Cleaner, Eureka Forbes or from any reputed make only as per specification given below:-Voltage- 230V AC,50Hz, Input Power(IEC)-1000 Watt, Suction of the motor 1700 mm of water column , Airflow-30 litres/second, Dust collection capacity-61(dry), 81(wet), Variable power option-2 Speed, Blower function, Air filtraction-2 Stage, Hepa filter, Dust collection type-Washable dust bag, On board accessory storage. Inspection:Consignee Inspection Charges: None Payment Terms: 100% after Supply | Numbers 2.00 | — | 22,344.97 | 44,689.94 |
| 71 | Hiring of JCB machine(in good condition) for levelling and dressing ground/ dismantling structures including disposal of debris through dumpers etc with contractors labour , JCB machine , machine operator, fuel etc. The contractor shall arrange for road permit for all the states for operation as per instructions of engineer incharge and vehicle shall not be more than 3 years old . Payment shall be made for actual working hrs at site. Inspection:Consignee Inspection Charges: None Payment Terms: 100% after Execution | Hour 50.00 | — | 1,090.59 | 54,529.5 |
| Schedule total | ₹2,03,48,899.89 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .