Tender Value
₹82.6 L
EMD Value
₹1.7 L
Closing Date
31 Aug 2026, 11:00 am7d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT G
15 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre- defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any electrical engineering work, provided that the tenderer has electrical contractor's license for the voltage that is the highest in the complete work.
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home Page of IREPS portal for works tenders before submitting the e-tender. 1. General Instruction for E-Tenders on works contract--Chapter-I 2. Special Condition-General-Chapter-II
1. I/We have visited the works site and I/We am/are aware of the site conditions. 2. We have read the tender Notice[NIT] details, Tender document along with all the conditions attached/referred to, in this tender document, and agree to abide by the said conditions. 3. We are aware of the fact that the railway reserves the right to amend the scope and value of the contract and to reject[or accept] this offer without assigning any financial liability.
The Tender document uploaded as "Tender Document.pdf" should be read in conjunction with the terms and conditions and should read and followed before quoting the tender.
(A) Provision of Maintenance Terminal Console (MTC)/Network Management System for Kyosan make Electronic Interlocking in Dhanbad Division. (B) Provision of Multi Section Digital Axle Counter (MSDAC) in Salaibanwa (SLBN) Yard under Dhanbad Division. (C) Provision of Dog Kennel at DHN. (D) Development of Shunting Track of Jharia Line to Washing Pit from Kalka end in Coaching Depot, Dhanbad. (E) Electrical work in connection with installation of HABD under DHN division. (F) Installation of Rolling-in/out examination lighting arrangement at SVPO, PLBS, BUKRU, BUMH & TORI siding Line. (G) Provision of Gang hut at Churki under ADEN/CPU.
EL-12-OPEN-2026-27~ECR
EL-12-OPEN-2026-27
Open
Works - General
12 Months
Dhanbad, Jharkhand
₹0
₹1.7 L
5 Aug 2026
5 Aug 2026
17 Aug 2026
286 items across 7 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,70,214.18 | ||
| — | 14.00 | — | — | ||
| Fixing, connection, testing & Supply of LED Batten, Box type luminaire, with CRCA body, Pre wired for LED tube with supply of Retrofit LED tubular lamp 1X20W,T-8, 4' long, complete with inbuilt LED driver, Make - Crompton, Havells, Bajaj, Polycab, Philips , Surya & Jaguar (LED Luminarie of the makes as specified above should be as per RDSO's specification for Energy efficient LED based luminaire unit for indoor lighhts to be used in Indian Railway offices and buildings. (Fixing of fitting to be done with proper clamping arrangement as per the site requirement and connection to be done with1.5 sqmm single core copper conductor FRLS by tapping from sub main line including supply of ceiling rose and wires and PVC flexiable pipe) ( The complete system of LED lights (including Driver etc) shall be guaranteed for satisfactorily performance and manufacturing defects for period of 60 months from the date of commissioning or 72 months from the date of suppply, whichever is earlier.(Reference: Railway Board's letter no.2006/Elect(G)/150/5 dated 27.03.15). | — | — | — | 13,003.48 | |
| — | 14.00 | — | — | ||
| Wiring of light point in a concealed / casing capping / PVC in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5mm (FRLS) multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire (Wire Make-Havells, anchor, Finolex, Polycab,Greatwhite ) controlling through flush type 10AMP, modular switch to be fitted with freme and tress plate, make Havells, anchor, Legrand, Slemens, L&T, or C&S. | — | — | — | 10,787 | |
| — | 6.00 | — | — | ||
| Supply & fixing of fan clamp made of MS flat and hook arrangement to take 20 Kg load (27 inch long). | — | — | — | 493.8 | |
| — | 3.00 | — | — | ||
| Fixing, connection, testing and Supply of Wall Bracket fan 400 mm sweep complete with all accessories. Make: Policab, Bajaj, Crompton, Havells | — | — | — | 8,095.11 | |
| — | 2.00 | — | — | ||
| Supply,& fixing of Metal body Exhaust Fans (non-capacitor type) copper wound , No of poles -4 & sweep size 300 mm (Make-Usha,Havells/crompton, Bajaj ) (Fixing of Exhaust Fans to be done by cutting the hole of reqired size along with supply and grouting of reqired nut,bolt & waser to suit the Ex-fan as per site requirement, including connection.) | — | — | — | 2,612.66 | |
| — | 11.00 | — | — | ||
| Wiring of fan point in a concealed / casing capping / PVC in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5mm (FRLS) multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire (Wire Make-Havells, anchor, Finolex, Polycab,Greatwhite ) controlling through flush type 10AMP, modular switch to be fitted with freme and tress plate, make Havells, Policab, anchor, Legrand, Slemens, L&T,or C&S. | — | — | — | 7,696.81 | |
| — | 24.00 | — | — | ||
| Supply , fixing & wiring of 5 pin 5/ 6A modular socket point in concealed/surface (Normaly concealed) in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated 1.5 sq.mm (FRLS) multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire (Wire Make-Havells, anchor, Finolex, Polycab,Greatwhite ) controlling through flush type 15/16 AMP, modular switch to be fitted with suitable GI/ PVC freme and tress plate, make Havells,Policab, anchor, Legrand, Slemens, L&T,or C&S. | — | — | — | 10,153.92 | |
| — | 6.00 | — | — | ||
| Supply , fixing & wiring of 6 pin 5/ 6A & 15/16 A modular socket point in concealed/surface (Normaly concealed) in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated 2x4sq.mm (FRLS) multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire (Wire Make-Havells, anchor, Finolex, Polycab,Greatwhite ) controlling through flush type 15/16 AMP, modular switch to be fitted with suitable GI/ PVC freme and tress plate, make Havells, Policab, anchor, Legrand, Slemens, L&T,or C&S. | — | — | — | 8,843.64 | |
| — | 2.00 | — | — | ||
| Supply & fixing of mounting bracket for out door unit of splite AC complete with nut, bolt & washer as required. | — | — | — | 2,600 | |
| — | 60.00 | — | — | ||
| Supply & fixing of C-PVC pipe size 3/4 inch with elbow, saddle and other accessories | — | — | — | 6,501 | |
| — | 2.00 | — | — | ||
| Supply , fixing & wiring of modular Ac box with modular socket 20Amp and MCB SP 20AMp in a conncealed/surface (6 pin 5/ 6A & 15/16 A modular socket point in concealed/surface (Normaly concealed) in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated 2x6sq.mm (FRLS) multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire (Wire Make-Havells, anchor, Finolex, Polycab,Greatwhite ) controlling through MCB SP 20AMP to be fitted with suitable GI/ PVC freme and tress plate, make Havells, anchor, Legrand, Slemens, L&T,or C&S. | — | — | — | 2,800 | |
| — | 100.00 | — | — | ||
| Wiring of sub-Main Line with FRLS copper wire single core size 6mm2 multistrand with earthing wire 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as required in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering or as per the requirement at site. (Wire Make-Havells,anchor, Finolex, Polycab, Mescab & KEI) | — | — | — | 5,677 | |
| — | 280.00 | — | — | ||
| Wiring of Main Line with FRLS copper wire single core size 10 mm2 multistrand with earthing wire 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as required in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering or as per the requirement at site. (Wire Make-Havells,anchor, Finolex, Polycab, Mescab & KEI) | — | — | — | 20,669.6 | |
| — | 25.00 | — | — | ||
| Wiring of Sub main concealed/surface(Normally concealed) in separate heavy gauge PVC conduit pipe 40mm size with single core PVC insulated multi strand copper conductor cable 1100 Volt confirming to IS:694/1990,4 nos of 16 sq.mm each for 3-phase and neutral and 1no. of 16 sq.mm for earth.The colour coding of cable red,yellow,blue for phase,black for neutral and green for earth must be maintained . No other sub-main & point wiring will be drawn with this sub-main wiring in same PVC pipe. PVC pipe make - Polycab, Pressfit, Precision. Wire/cable make-Havells, Polycab, Finolex | — | — | — | 22,896 | |
| — | 1.00 | — | — | ||
| Fixing, connection, testing & Supply of MCB Distribution Board 4-way 8+12 ,double door,IP-43-protection, with supply of MCB 63A, TPN, 10 KA, B-Curve, conforms to IS:60898 -02 Nos as incoming & MCB 20A, DP, 10 KA, B-Curve, conforms to IS:60898- 06 Nos as outgoing. Make - L&T, Havells, Legrand, Havells, C & S (Fixing of Distribution Board to be done as per the site requirement (normally concealed) and connection to be done with suitable conductor including supply of PVC flexiable pipe) | — | — | — | 9,781.94 | |
| — | 1.00 | — | — | ||
| Supply & fixing of Busbar Chamber 4-way 100A (Make Havells/C&S/L&T) (Fixing with proper excavation and refilling the wall with proper re-plastering of the wall) | — | — | — | 8,039.72 | |
| — | 1.00 | — | — | ||
| Testing, commissioning, installation and supply of MCCB,100A, 35KA, four pole, with thermal magnetic release with suitable MCCB enclosure. Fixing to be done as per the site requirement under supervision of site incharge including connection with crimping of cable ends with aluminium lugs of required sizes (Make -Indo asian, C&S, Havells, L&T ) | — | — | — | 11,034.67 | |
| — | 3.00 | — | — | ||
| Provision (Supply and erection) of Earthing station (RI-7021) as per Drg.No. ETI/ OHE/P/ 7020 or latest.(The price shall cover supply and erection of an earth electrode (RI 7021) as per drawing no. ETI/OHE/P/7020. The price shall also cover the provision of a protective concrete Box with removable MS cover. The material should confirm to ACTM vol. II Part II Para 7.1.1 with figure A 3.01. The price shall cover the testing of earth value and painting the value on the earth pit. The earth electrode shall normally be of mild steel galvanized perforated pipe of not less than 44 mm nominal bore and about 3 meter length provided with a spike at one end and welded lug suitable for connecting directly Earth wire/MS flat of required size at other end. The connection of Earth wire/M S flats to each electrode shall be made through M S links by bolted joints, fasteners to be supplied by the contractor. The earth surrounding the electrode shall be chemically treated by alternate layers of fine charcoal and salt at least 150 mm all around. The item should be procured from approved supplier of CORE or RDSO, duly inspected by either RITES or Railway Representative deputed by Sr. Div. Elect.Engineer (G)/ Dhanbad.) | — | — | — | 8,861.43 | |
| — | 200.00 | — | — | ||
| Providing and fixing 06 SWG / 5.0 MM dia GI wire on surface or in recess for loop earthing of street light poles, connection from earth pit to main junction board/panel, connecting different earth pits etc. Connection and Looping of earth wire to be done with suitable fasteners, nuts bolts and washer as required. | — | — | — | 1,396 | |
| — | 500.00 | — | — | ||
| ISI marked four core circular armoured cross linked polyethylene (XLPE) LT insulateed cable. PVC outer sheathed armoured with galvanised round steel wire or steel strip and with aluminium conducter suitable for rated voltage 1100 volts, grade conforming to IS:7098 [part-1]- 1988 with admt. no. 1,2 and 3 [reaffirmed 2005] size 4*70 sq. mm. The firm will have to submit type test report as per IS from NABl accredited lab alongwith the tender. Type test report should not be more than 10 years old on the date of bid opening. | — | — | — | 1,59,000 | |
| — | 60.00 | — | — | ||
| Trenching, laying and back filling of XLPE cable as per Sr.DEE(G)/DHN's drg. No. EL/486-01 | — | — | — | 3,587.4 | |
| — | 900.00 | — | — | ||
| Laying and fixing PVC/XLPE cables of different sizes ranging from 25 sq mm to 120 sq mm on surface of the wall (normally concealed)/steel structure as per the requirement of site with proper clamping arrangement as required at every 1/2 metre. | — | — | — | 44,703 | |
| — | 280.00 | — | — | ||
| ISI marked four core circular armoured cross linked polyethylene (XLPE) LT insulateed cable. PVC outer sheathed armoured with galvanised round steel wire or steel strip and with aluminium conducter suitable for rated voltage 1100 volts, grade conforming to IS:7098 [part-1]- 1988 with admt. no. 1,2 and 3 [reaffirmed 2005] size 4*50 sq. mm. The firm will have to submit type test report as per IS from NABl accredited lab alongwith the tender. Type test report should not be more than 10 years old on the date of bid opening. | — | — | — | 71,680 | |
| — | 160.00 | — | — | ||
| ISI marked four core circular armoured cross linked polyethylene (XLPE) LT insulateed cable. PVC outer sheathed armoured with galvanised round steel wire or steel strip and with aluminium conducter suitable for rated voltage 1100 volts, grade conforming to IS:7098 [part-1]- 1988 with admt. no. 1,2 and 3 [reaffirmed 2005] size 4*95 sq. mm. The firm will have to submit type test report as per IS from NABl accredited lab alongwith the tender. Type test report should not be more than 10 years old on the date of bid opening. | — | — | — | 64,800 | |
| — | 1.00 | — | — | ||
| Dismantling & erection of solar panel/ Metering Unit with minor civil work | — | — | — | 25,000 | |
| — | 300.00 | — | — | ||
| Supply, wiring & connection of single core 16 mm copper wire. . (Wire Make-Havells, anchor, Finolex , Polycab , KEI & Mescab) | — | — | — | 94,500 | |
| — | 100.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-12.pdf
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
GCCCorrectionslip1to11_compressed.pdf
ATTACHMENT
LEDstreetlight.pdf
ATTACHMENT
LED_Indoor_lighting_specifications_EOI.pdf RDSO Specification for indoor light
ATTACHMENT
LED_Indoor_lighting_specifications_EOI.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].