GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
REPAIR AND MAINTENANCE OF SUMMER AND WINTER APPLIANCES OF ALL TYPE OF OTM ACCOMMODATION UNDER GE SHIKARGARH IN ARMY AREA JODHPUR
2020_MES_374774_1
8661/E8 55
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE SHIKARGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹24,000
Yes
19 Nov 2020
4 Sept 2020
30 Sept 2020
4 Sept 2020
28 Sept 2020
11 Sept 2020
4 Sept 2020 - 10 Sept 2020
60 days
Amount
Taking down ceiling fan, exhaust fan, Cabin/wall/pedastal fan/air circulator of any capacity /size for Servicing giving heavy noice/slow speed /vibration etc and strip opening at site checking greasing/oiling/cleaning complete with replacing petty items such as nuts,bolts split pin,flexible cable , capacitor,MS clamp,rubber real,bearing/bush and check RPM with fixing of blade after repair work is over and refix the same its orignal place to th entire satisfaction Engineer-in-charge Note :- (i) Capacitor /Bush/Bearing.MS Clamp rubber real etc will be measured and paid for separately under respective items. (ii) Technician of contractor shall visit door to door and attend complaint in in respective bldg inMd Accn and obtain thre signature of user after satisfactory of work Note : Any unsv parts reqd for replacement shall be measured and paid separately under respective item of Schedule as supply only.
M&L for rewinding to ceiling fan motor of 1200mm /1400 mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conducor of size 23/.0076 upto connector block Complete all as specified and as directed. Note :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings , Bush & shaft shall be measured & paid as Supplly only seperatly under respective item of this schedule . Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account
M&L for rewinding to Exhaust fan motor of 450 mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up-to connector block Complete all as specified and as directed
All as per above item No 3 here-in –before but 375 mm sweep
All as per above item No 3 here-in –before but 300 mm sweep
Rewinding of cabin/wall/pedastal fan (Any make, type & sweep ) with super enameled copper winding wire complete matching with required gauge, and testing it for smooth functioning complete all as specified and as directed Notes for item No 2 to 6 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings, Bush & shaft shall be measured & paid as Supply only separately under respective item No of this schedule . Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account.
Supply only ball bearing of suitable size for ceiling fan/wall/cabin/pedastal fan of any make/any model and any sweep complete all as specified and as directed. Make:- SKF/NBC/Tata
Supply only ball bearing of suitable size for exhaust fan of any make/any model and any sweep complete all as specified and as directed. Make:- SKF/NBC/ Tata
Supply only Gun metal bush and supply and fixing Gun metal bush of suitable size.
Supply only capacitor clamp and split pin .
Supply only capacitor 2.5 MFD Make :- DENFOS/ INDOFOS /EPCOS /HAVELLS all as specified and directed.
Supply only capacitor 4 MFD Make :- DENFOS/ INDOFOS /EPCOS /HAVELLS all as specified and directed.
Supply only Fan hanging clamp complete.
Supply only Down rod 15 mm dia MS tube 60 cm long
Supply only Down rod 15 mm dia MS tube 90 cm long
Supply only Down rod 15 mm dia MS tube 120 cm long
S&F in replacement electronic fan regulator 230 volts, step type, hum free, 120 watt type ISI marked complete all as specified.
Maintenance, servicing and testing of split type/window type AC, capacity upto 1.50/2 tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water , checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor.
Maintenance, servicing and testing of water cooler any make and capacity by cleaning cooling coil, with VINICLEAN solution using pressure jet system with water , checking and decarbonising all electric system oiling/greasing of fan motor, checking and removing any vibration and leakage in the equipment including cleaning of tank with bleaching powder complete all as directed by Engineer-in-Charge. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, is deemed to be inclusive in the unit rates quoted by the contractor.
S&F, in replacement, new compressor for window type AC 1.5/2 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool
S&F, in replacement, new compressor hermetic/rotary for split type AC 1.5/2 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool
M&L for finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of window type/Split type AC of 1.5/2 Ton cap including dismantling the same for recharging with R-22 gas or as per manufacturer's instruction and stop leakage by brizing/soldering including charging the gas to required level and testing the AC for the entire satisfaction of EIC.
S&F nylon type filter pad 20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed.
S&F, in replacement, running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make : Keil / Asian /Tesla.
Supply and fixing in replacement starting capacitor clip type of cap. 80-100 MFD,440 suitable for 1.5/2 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge make- Kell/Tesla/Sharda/Escop
S&F in replacement of running capacitor, 100-120 MFD suitable for 1.5 / 2.00 Ton capacity window/split type AC of approved make.
S&F, in replacement, starting relay suitable for window type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
S&F, in replacement, over load protection suitable for window/split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
S&F, in replacement, thermostat switch suitable for window/split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
S&F, in replacement, blower motor 1/8 HP, double shaft, single phase suitable for window type AC up to 2 ton capacity including testing complete all as specified and directed.Make: Khaitan or Universal.
S&F, in replacement, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol
S&F, in replacement, blower motor 1/8 HP, double shaft, single phase suitable for split type AC up to 2 ton capacity including testing complete all as specified and directed. Make: Khaitan or Universal.
S&F, in replacement, internal unit complete for split type AC 1.5/2 Ton capacity, comprising of blower motor, fan blade with rotor, evaporator with suitable filter, remote control system along with outer shell complete all as specified and directed. Make: Blue star/LG/Hithachi.
S&F, in replacement, external unit including compressor for split type AC 1.5/2 Ton capacity, comprising of condenser oil, blower motor, blower fan, copper valve ½” & 5/8” with hot and cold arrangement including copper condensor coil complete all as specified and directed.
S&F, in replacement, power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed.
Supply and fix new compressor for water cooler of capacity 40/80 Ltr, deep freezer capacity 200 to 300 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar Model 2612, or Shriram Model-412Y
Supply, fixing & testing new compressor for water cooler of capacity 60/120 Ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar, or Shriram
M&L for trickle charging of gas F-12 or as required in water cooler, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified.
S&F, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed. MAKE: SHRIRAM or RANUTROLL or INDOFOSS.
S&F, in replacement starting relay for refrigerator/deep freezer of different capacity/make including taking out unserviceable relay complete all as specified and directed. Make : SG-8 or Renutrol or K.C.U 7
S&F, in replacement blower motor 1/35 HP with base and clamp, rubber mountings for water coolers including taking out the old unserviceable motor complete all directed. Make: Universal/Crompton Greaves/Cool king/ American Universal
S&F, in replacement capillary filter drier 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified and directed
Rewinding of blower motor of water cooler 40/80 ltrs capacity any make with super enamelled copper wire (Make:- Atlas/Chetak/Devidayal) incl replacement of wornout bushes etc and testing complete.
S&F in replacement push type water tap, 15 mm dia, chromium plated suitable for water cooler complete all as specified and directed.
Rewinding of blower of Deep freezer up to 400 ltrs capacity having single/double door any make with super enamelled copper wire (Make:- Atlas/Chetak/Devidayal) including of wornout bushes etc and testing complete.
Supply, fixing & testing new compressor for refrigerator/deep freezer of capacity 286/310/320 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar/Shriram
S&F, in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified and directed. MAKE: SHRIRAM or RENUTROL or INDOFOSS.
M&L for trickle charging of gas F-12 or as required in refrigerator/deep freezer of capacity 286/310/320 Ltr, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified.
S&F in replacement freezer assembly suitable for refrigerators of any make, 286/310 ltrs capacity including taking out unserviceable assembly complete all as specified and directed. MAKE : Kelvinator / Zenith / Godrej/ Whirlpool /Voltas
S&F, in replacement capillary tube made of copper, any size suitable for Refrigerator/Water Cooler including taking out old unserviceable capillary tube complete all as specified and directed.
S&F in replacement cooling effect transmitting motor suitable for refrigerator 310 Ltrs capacity all as specified and directed by Engineer-in-charge. Make Sam Sung
S&F in replacement drain out pipe of split type AC complete all as directed by Engineer-in-Charge.
S&F in replacement door gasket suitable for refrigerator of capacity 165 / 300 Ltrs o any make all as specified and directed by Engineer-in-charge.
Material and labour for cleaning down complete body including fittings and fixtures of desert cooler of any make and any capacity and painting desert cooler of capacity with spray painting machine with two coats of synthetic enamel paint powder coated (first quality,shade : silver grey as approved of make ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson Paints (BOROLAC) Berger paints (LUXOL HI CLOSS ) and two paint to inner surfaces including preparation of surface and painting inside with black rubber bitumen paints including taking down and refixing all parts as specified & directed by EIC.
S&F, in replacement, blower motor 1/8 HP, single phase suitable for desert cooler including testing complete all as specified and directed. Make: Khaitan/Universal/Pilot.
M&L for taking down existing unserviceable fan motor from desert cooler and including replacement of wornout winding, bushes and bearing etc and testing complete, refixing and connecting complete all as directed by EIC.
Replacement of Water lifting submersible pump suitable for desert cooler as per existing capacity. (Make : Snow Cool/LITTLE/universal)
S&F PVC distributor, size 15mm for desert coolers including taking out unserviceable distributor complete all as specified and directed.
S&F PVC Elbow, size 15mm for desert cooler including taking out unserviceable elbow complete all as specified and directed.
S&F PVC pipe 15mm dia suitable for desert coolers including taking out unserviceable PVC pipe complete all as specified and directed.
S&F cooler pad made of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed.
S&F in replacement starting capacitor 40 MFD 230 volts including taking out unserviceable capacitor, including testing complete all as specified and directed. Make : Keil / Asian /Tesla.
Supply and fix in replacement brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple directed by Engineer -In -charge
M&L for replacement of Fan blade of desert cooler heavy duty suitable for 4000/5000/600 CFT cap complete all as directed by EIC.
M&L for replacement of copper conductor cable 40/0.0076 Sqmm 3 core not less than 3 mtrs long with plug top 5 Amp suitable for desert cooler (Make FINOLEX/PARAGUN/POLYCAB).
Repair of voltage stabilizer of capacity 5 KVA, 20 Amp, AC, SP 230 Volts for rewinding of main transformer & electronic circuit including auto cut relays for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including replacement of Volt meter, Amp meter, MCB 20/32 Amp, indicator lamp, main lead 3 metre long, 3 core 40/.0076, fuse grip, output connection including testing complete all as specified and directed.
Repair of voltage stabilizer of capacity 3 KVA, 20 Amp, AC, SP 230 Volts for rewinding of main transformer & electronic circuit including auto cut relays for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including replacement of Volt meter, Amp meter, MCB 20/32 Amp, indicator lamp, main lead 3 metre long, 3 core 40/.0076, fuse grip, output connection including testing complete all as specified and directed.
Repair of voltage stabilizer of capacity 1 & 2 KVA, 20 Amp, AC, SP 230 Volts for rewinding of main transformer & electronic circuit including auto cut relays for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including replacement of Volt meter, Amp meter, MCB 20/32 Amp, indicator lamp, main lead 3 metre long, 3 core 40/.0076, fuse grip, output connection including testing complete all as specified and directed.
Supply and replace metal clad/Sheet metal plug and socket with 2 pin earth plug and 20 Ampws SP MCB 240 Volt complete including making all connections Make :- Havells or equivalent Legrand
S&F in replacement 3 pin top plug , 15 Amp press type complete all as specified. Make : Anchor/SSK/cona
Supply and fix 15 mm GI tubing medium grade with all fiting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee, bend elbow and union etc taking down the existing pipes and connections ISI makked) Make :- Tata/Jindal/ Parkash Surya
S & F Stop valve,ISI Marked cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes of dia 15 mm all as specified and directed by Engr-in-charge. Make : Zolato/Bir/kartar
S&F Bib tap ISI Marked of size 15 mm cast copper alloy with clutch or butterfly handle ,screwed for iron pipe or for brass ferrule and fixed complete all as specifed and directed by Engr-in-charge . Make : Zolato/Bir/kartar
Comprehensive repairing/maintenance/Servicing of Solar Water heater of Capacity 300 LPD of any make any model installed at various location, and remove the dust from solar Plate and make solar water heater serviceable by replacement of any defective parts of solar panel all as directed by Engr-In-Charge.
Taking down carefully storage type water heater (Gyser) 25-35 Liters Capacity after disconnecting inlet/outlet/vent pipes, electric/earth connection etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by welding/braxing etc reassembling the geyser by replacing gaskets worm out nuts washers etc reficing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/ventpipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge for geyser of capacity. Note :- Non return valve stop valve bib tap/PVC connection/Copper connection cable,glass wool, element ,thermostat, storage tank, geyser assembly , indicator etc shall be measured separately.
All as per above item No 76 here-in –before but 50 Liters Capacity
Supply and replace heating element 1.5 Kilo Watt Capacityof storage type water heaters of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-charge of capacity Make :-RECOLD / VENUS / GILCO / PREMIER / CHEETA /Bajaj/CROMPTON
All as per above item No 78 here-in –before but 2.0 Kilo Watt capacity-ditto-
Supply and fix thermostat suitable for 25/35/50 liter capacity storage type water heater including removal of old unserviceable ones all as specified and as directed by Engineer-in-Charge make :- Bajaj/ Usha/Venus
Supply and fix non return valve (gun metal) of size 15 mm including removal of old one.
S & F in replacement Geyser SS assembly for housing Heating element, 6 & 9 Holes type for 50/35/25 liters for storage type Geyser as per sample
S & F in replacement Geyser SS tank for 50/35/25 liters for storage type Geyser with MS collar as per sample.
S & F replacement, glass wool for 50/35/25 liters storage type Geyser as per sample
S & F in replacement , safety valve suitable for storage type Geyser of capacity 50/35/25 liters as per sample
M&L PVC insulated 3 core copper conductor wire of size 2.5 sqmm overall PVC seathed for Geyser connection including taking down old one . Make :- Finolex/Havells/Polycab
M & L for indicator lamp suitable for 25/35/50 liters geysers as per existing sample in green and red colour including taking down old one complete all as specified and as directed by Engr-in-Charge.
Prepartion of old painted surface of Geysers and applying one coat of synthetic enamel paint with spraying paint machine including making MES number on body of the Geyser including taking down and refixing and connection and testing complete all as specified and as directed by Engr-in-Charge.
S& F of PVC connction of size 15 mm dia, 300/450 mm with nuts suitable for Hot & Cold water for connection of geysers complete all as speified and directed by Engr-in-Charge. Make :- Prayag /shakti
Surendra Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .