Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC | ₹5.3 Cr Quoted ₹5.5 Cr | L1 | Accepted-AOC AOC |
Tender Value
Refer Docs
EMD Value
₹18.6 L
Closing Date
31 Jan 2023, 5:00 pmClosed
Superintending Engineer
SUPERINTENDING ENGINEER, CONSTRUCTION CIRCLE, UTTARAKHAND PEYJAL NIGAM, PAURI GARHWAL
construction of all Civil and E M, Surveying, Design Supply, Cartage laying Jointing of GI MS ERW Pipe of 15mm to 100 mm dia by Socketing Electric arc welding, RCC Circular CWR 10 KL 60 KL Capacity, Pump House other appurtenent works under Pathur
2022_MDPEY_52172_2
2988/Nivida Quotation/246 dated 26-11-2022
Open Tender
Civil Works - Water Works
Item Rate
365 days
Dugadda
as per Tender Document
3 documents required · 3 mandatory
₹5,900
Executive Engineer, C.D. Peyjal Nigam Kotdwar
₹18.6 L
kotdwar
29 Sept 2023
17 Jan 2023
2 Feb 2023
17 Jan 2023
31 Jan 2023
21 Jan 2023
17 Jan 2023 - 19 Jan 2023
19 Jan 2023
Amount
Construction of intake chamber at tapping point of source for collection of water including supply of all materials , labours , T& P. Complete as per departmental desing & drawing in direction of engineer in charge.
Construction of R.C.C B.F.G at source work including construction of intake chamber and supply of all materials,labour, T&P etc. complete as per departmental desing & drawing in direction of engineer in charge.
Supply of all material, labour, T&P etc. all complete and provide 90 cm high RCC cross wall at gadhera tapping point for the protection of intake from flood storm as per departmental desing, drawing in direction of engineer in charge.
Supply, Carting (site store to trench) , Painting , lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line by welding for making up lengths as required for proper completion of work of following grade & sizes ((Excluding cartage from Rail Head to site store.) MS ERW Pipe Yst 210
100 mm dia 4.8 mm thick
Excavation in soil mixed with single boulders etc. requiring the use of special T&P, if any, for pipe line trenches including lift up to 1.5m and lead up to 30m with back filling, watering, ramming of excavated earth in the trenches.
Same as item No. 5.1 above but excavation in decomposed, weathered or soft rock by blasting or by drawbars, pickaxes etc. or by both methods, including supply of all materials, labour, T&P etc.
Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.50m in width or 10.0sqm in plan) including dressing of sides and ramming of bottoms, lift up to 1.50m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m in all kinds of soil.
Survey, design, supply carting, laying & jointing of G.I.(M) class pipe by socketing for Supply Main/ Feeder Main/Distribution System of following sizes including provision of specials and other appurtenant works such as scouring arrangement at suitable locations by fixing tee etc. complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. complete. G.I. (Medium Quality) As per IS 1239 Part I : 2004
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Supply and fixing of the following fittings including cartage of materials, labour, T & P etc complete as per direction of Engineer-In-Charge.but excluding the cost of excavation and chamber. G.M. Wheel valves (Class I) as per IS 778/1971
25 mm dia
32 mm dia
50 mm dia
80 mm dia
C. I Air Valve (Screwed) 15 mm dia
Supply, cartage and fixing of following size of Sluice Valve/Reflux valves/Double Ball Air Valve including carting the same up to site of work and fixing the same in water supply lines including cost of valves, specials, labour an T&P complete in all respect as per direction of Engineer-In-Charge.
100 mm dia. Cast steel Sluice / Scour Valve, W.P. 50 Kg/cm2
100 mm dia. Cast steel Reflux / Swing Check Valve, W.P. 50 Kg/cm2
50 mm dia. Cast steel Double Ball Air Valve Flanged type, W.P. 25 Kg/cm2
Construction stone masonry Wheel Valve / Air valve chamber 60x60x60 cm, inside in 1:4 cement & sand mortar with MS MH cover on top the chamber with proper locking arrangement as per departmental desing & drawing in direction of engineer in charge.
Supply of all materials, labour, T & P etc. and Construction of Thrust Block as per type design complete (1 in 200 m length Pipeline)
Size of Anchor Block - 1.2 m x 1.2 m x 1.5 m
Supply of all materials, labour T&P etc complete and construct pump house at MPS (5.5 M X 5.0 M X 4.5 M) size as per approved designed & drawing including all necessary arrangements.
Provision of 1.5 m high Boundary Wall at MPS in brick masonry including supply of all materials, labour, T&P etc. complete as per departmental desing & drawing in direction of engineer in charge.
Supply & Fixing Iron Gate with Pillers of Size 1.00 m wide (Clear Size) including locking arrangement including Supply of all accessories fixing arrangement in all repect complete as per departmental desing & drawing in direction of engineer in charge.
Supply of all materials , labour and T & P etc. and construction of R.C.C Clear Water Reservoir of following capacity in K.L as per type design and drawing including fixing of pipes and fittings including cartage of materialls etc.
60.00 Kl capacity clear water Sump at TOP CWR
60.00 Kl capacity clear water Sump at MPS
60.00 Kl capacity clear water reservoir
17.50 Kl capacity clear water reservoir
15.00 Kl capacity clear water reservoir
10.00 Kl capacity clear water reservoir
Supply & Fixing of 25 litre capacity M.S Bucket Type Chlorinator of standard size with glass wooling including supply of all labour material T&P etc complete as per direction of Engineer-In-Charge.
Supply & Fixing an Iron Board and Printing on it as well as writing the details of Work on it as per direction of Engineer-In-Charge.
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of ferrule including tapping the main, but excluding the cost of earth work and cost of all materials.
Providing and fixing brass ferrule 15mm dia. nominal bore for domestic connections.
Providing and fixing of PTMT bib cock 15 mm dia. nominal bore for domestic connections.
Dismantling of cement concrete road pavement for laying different sizes of pipes, stacking the serviceable materials and disposal of waste materials upto a distance of 50 m including supply of materials, labour, T&P etc. complete.
Random rubble stone masonry in 1:6 cement and local sand mortar for protection work on pipe line, treatment site & where ever required as per site requirement including supply of all materials T&P etc required for proper completion of work as per direction of Engineer-In-Charge.
Random rubble masonry laid dry in breast walls, retaining walls etc. including supply of all material, labour, T&P and royalties etc required for proper completion of work as per direction of Engineer-In-Charge
Providing & laying PCC 1:2:4 in cement, coarse sand and 20 mm gauge approved stone ballast, including supply of all materials, labour , T&P required for proper completion of work as per direction of Engineer-In-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Design, Supply of all materials, labour, T&P. etc to construct a water treatment plant (WTP) to treat 0.20 MLD water based on rapid gravity filtration. The design of filter plant has to be done on the based on CPHEEO manual for Water Supply and Treatment. The filter plant should consists of inlet chamber, flow measuring device, presettling tanks (1 units), mixing units, flocculation unit, secondary settling tank (1 units), rapid gravity filter (minimum 2 filter beds), clear water chamber including all piping, valves, RCC back wash tank, double storey building (minimum 30 sqm) one floor will be used for office and other floor will be used for chemical room). Each floor height should be minimum 3.30 m. The work also include 60 cm apron and 15 cm semicircular PC drain all around all units and including overall drainage of water treatment campus upto outside 5 m of campus boundary. The work should also include internal electrification of all units as well as external electrification as per requirement of site. The work also include 1 m inter connecting RCC/CC path ways to all units as per site requirement. The work also include necessary excavation as per requirement and development of water treatment plant and disposal of surplus earth from site of work to suitable available place but excluding the cost of protection works, boundary wall and gates, which will be executed separately as per approved layout and design of treatment plant. The contractor is advised to inspect the site of work. No excuse and request to change the site, rates and demand of extra rates will be entertained at later stage.
MPS- Centrifugal pumps (460 LPM discharge at 460 Mts. head.)
Electric Motor
Base Plate
Starter
Control Panel as per site requirement
150 mm² 3½ core Al Conductor Armoured cable of 1.1 KV grade.
50 mm² 3 core, Cu Submersible cable 1.1 KV grade.
Jointing materials
Double Loop Earthing As per site requirement
Main piping & valves as per site requirement
Pressure Gauges
Tools as per site requirment
HOT Crane
Supply of rubber resistance sheet of size 1m x 2m x 0.025m
Installation & Commissioning of above Pumping Plants .
Testing of Pumps At works
Testing of Pumps At Site
Transformer-250 KVA
Cost of Internal & external electrification
H.T Panel
Earthing of all Transformer & HT Panels
HT cable Jointing kit outdoor type / Indoor type
Fencing of transformer
XLPE,3 Core, 70 mm sq. H.T. alumuniam armoured cable
Automation- GSM based RTU
GSM based wireless communication hardware
Intelligent Energy meters
Valve Actuator for 100 mm dia valve.
Actuator Panel
Hard wired timer circuit for actuator
Pressure Transmitter
Level transmitter of 10 mt range
Isolation Transformer
Over voltage and under voltage trip protection
Electromagnetic Flow meter for line sizes of 100 mm NB size
2 Core x 1.5 sqmm PVC coated flexible screened cable.
4 C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
10C x 1.5 sq mm PVC coated flexible unsreened Cu cable.
Conduit pipe 1” PVC
Conduit pipe 1.5” PVC
Accessories
Erection commissioning of all instruments and customization of software.
O&M- After testing & commissioning of scheme running & maintenance of scheme by running pumping plant for 8 hrs per day (for a period of 6 months or complete Distribution line testing of civil works which over later ) including supply of skilled O&M staff, account maintenance including supply of all materials, labour, T&P etc. complete but excluding electricity charges for pumping of water.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .