Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.4 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹32.3 L+₹24,898 (0.78%)Rejected-Finance | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹37.8 L+₹5.8 L (18.0%)Rejected-Finance | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹38.6 L+₹6.6 L (20.5%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | 5₹39.9 L+₹7.9 L (24.7%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 5 | Rejected-Finance Not Being Lowest Bidder |
| Sl No | Description | Qty | Unit | F AND M TECHNOLOGIES L2 | suresh electricals L1 | LAKSHMI SAI CONSTRUCTIONS L3 | SRI RAJA RAJESWARI ENTERPRISES L5 | ANAND ENTERPRISES AND ENGINEERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for taking down the defective Split Type AC Unit 1.5 TR Capacity, shifting to work shop, taking out the defective unserviceable Hermetically Sealed Compressor from the unit, replacing the compressor with New Compressor of the same capacity, fixing in the unit, interconnecting the Refrigerating Lines, flushing out the Cooling Coil & Condenser thoroughly for removing carbon deposits, cleaning with CTC, Leak Testing, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, testing at Workshop, shifting to the location and reinstalling the same in its original position, connecting up all electrical connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson. Note: Rate quoted is deemed to be inclusive of Cutting, Welding, Brazing, Sealing the Refrigerant Tubing, replacement of Strainer, CTC, Nitrogen Gas, Refrigerant Gas, to and from transportation and handling complete. | 5 | Each Job | 4,000 ₹20,000 Lowest | 13,500 ₹67,500 | 12,000 ₹60,000 | 8,000 ₹40,000 | 9,200 ₹46,000 |
| 2.00 | All as per Serial Item No. 1 above but Split Type AC Unit of 2.0 TR Capacity. | 5 | Each Job | 4,100 ₹20,500 Lowest | 15,500 ₹77,500 | 14,000 ₹70,000 | 10,500 ₹52,500 | 11,300 ₹56,500 |
| 3.00 | All as per Serial Item No. 1 above but Window Type AC Unit of 1.5 TR Capacity. | 3 | Each Job | 2,000 ₹6,000 Lowest | 13,000 ₹39,000 | 11,000 ₹33,000 | 9,500 ₹28,500 | 9,200 ₹27,600 |
| 4.00 | M & L for taking down the defective Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted sheet metal parts with the same thickness of MS Sheet as per the existing size & shape including cutting, bending, welding, drilling, fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Mounting Legs, Rubber Bushes and cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson | 4 | Each Job | 4,000 ₹16,000 | 4,000 ₹16,000 | 3,500 ₹14,000 | 3,500 ₹14,000 | 1,650 ₹6,600 Lowest |
| 5.00 | M & L for taking down the defective Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted Sheet Metal Parts with the same thickness of MS Sheet as per the existing Size & Shape including Cutting, Bending, Welding, Drilling, Fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Rubber Bushes, cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson | 1 | Each Job | 4,800 ₹4,800 | 3,000 ₹3,000 | 3,500 ₹3,500 | 3,500 ₹3,500 | 1,850 ₹1,850 Lowest |
| 6.00 | S & F in repairs Condenser Fan Blade of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. | 6 | Each Job | 900 ₹5,400 | 800 ₹4,800 | 600 ₹3,600 Lowest | 900 ₹5,400 | 650 ₹3,900 |
| 7.00 | S & F in repairs Indoor Blower Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. | 8 | Each | 1,500 ₹12,000 Lowest | 3,000 ₹24,000 | 3,000 ₹24,000 | 3,900 ₹31,200 | 1,700 ₹13,600 |
| 8.00 | M & L for cleaning and preparing the surfaces of Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make thoroughly and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. | 5 | Each Job | 2,800 ₹14,000 | 450 ₹2,250 Lowest | 450 ₹2,250 Lowest | 500 ₹2,500 | 700 ₹3,500 |
| 9.00 | M & L for cleaning, flushing the Refrigeration System of Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make thoroughly with CTC and Nitrogen Gas, Leak Testing and locating the leaks, rectifying the leaks by brazing the joints, replacing the damaged Copper Pipes, Silver / Copper Rod, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, replacement of Strainer and connecting up all electrical connections and testing complete all as specified and as directed. | 6 | Each Job | 1,500 ₹9,000 Lowest | 2,500 ₹15,000 | 2,000 ₹12,000 | 2,100 ₹12,600 | 1,650 ₹9,900 |
| 10.00 | S & F in repairs Temperature Sensor Probe of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. | 10 | Each Job | 250 ₹2,500 Lowest | 700 ₹7,000 | 350 ₹3,500 | 765 ₹7,650 | 500 ₹5,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Jul 2025, 6:00 pmClosed
Shri Azmat Arshi, IDSE, Garrison Engineer P Navy K
Garrison Engineer P Navy Kalinga, INS Kalinga Complex, INS Kalinga Post, Visakhapatnam - 531 163
Repairs Maintenance of Window Split Air Conditioners, Water Cooler, Refrigerator, Repair Maintenance of Ceiling Fan, Wall Mounted Fan, Electric Geysers, Electric Meter, Solar Water Heater and Repair Maintenance of Lightening Protection, Earthing
2025_MES_712471_1
8199 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class D
Category b i
9 documents required · 9 mandatory
₹500
Garrison Engineer P Navy Kalinga
₹98,000
Yes
10 Sept 2025
4 Jun 2025
9 Jul 2025
4 Jun 2025
2 Jul 2025
18 Jun 2025
4 Jun 2025 - 11 Jun 2025
Amount
M & L for taking down the defective Split Type AC Unit 1.5 TR Capacity, shifting to work shop, taking out the defective unserviceable Hermetically Sealed Compressor from the unit, replacing the compressor with New Compressor of the same capacity, fixing in the unit, interconnecting the Refrigerating Lines, flushing out the Cooling Coil & Condenser thoroughly for removing carbon deposits, cleaning with CTC, Leak Testing, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, testing at Workshop, shifting to the location and reinstalling the same in its original position, connecting up all electrical connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson. Note: Rate quoted is deemed to be inclusive of Cutting, Welding, Brazing, Sealing the Refrigerant Tubing, replacement of Strainer, CTC, Nitrogen Gas, Refrigerant Gas, to and from transportation and handling complete.
All as per Serial Item No. 1 above but Split Type AC Unit of 2.0 TR Capacity.
All as per Serial Item No. 1 above but Window Type AC Unit of 1.5 TR Capacity.
M & L for taking down the defective Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted sheet metal parts with the same thickness of MS Sheet as per the existing size & shape including cutting, bending, welding, drilling, fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Mounting Legs, Rubber Bushes and cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson
M & L for taking down the defective Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted Sheet Metal Parts with the same thickness of MS Sheet as per the existing Size & Shape including Cutting, Bending, Welding, Drilling, Fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Rubber Bushes, cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson
S & F in repairs Condenser Fan Blade of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed.
S & F in repairs Indoor Blower Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed.
M & L for cleaning and preparing the surfaces of Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make thoroughly and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed.
M & L for cleaning, flushing the Refrigeration System of Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make thoroughly with CTC and Nitrogen Gas, Leak Testing and locating the leaks, rectifying the leaks by brazing the joints, replacing the damaged Copper Pipes, Silver / Copper Rod, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, replacement of Strainer and connecting up all electrical connections and testing complete all as specified and as directed.
S & F in repairs Temperature Sensor Probe of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed.
S & F in repairs Printed Circuit Board [PCB] of Dual Inverter 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed.
S & F in repairs Sealed Fan Motor of Indoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make including testing & commissioning the unit complete all as specified as directed. Make: AUE / Free Flow
S & F in repairs Air Filter Set of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed.
S & F in repairs 36/45 Mfd, Running Capacitor, +5% SH, 440 Volts, AC, 50 Hz including testing & commissioning the unit complete all as specified as directed. Make: Sarada / Unistar
S & F in repairs Running Capacitor of combination 45/2.5/45/4 Mfd, +5% SH, 440 Volts, AC, 50 Hz suitable for Compressor, Outdoor Unit Fan Motor of 1.5 / 2.0 TR Capacity Split Type AC complete all as specified and as directed. Make: Sarada / Unistar
S & F in repairs Starting Capacitor 80 / 100 Mfd, 240 Volts, AC, 50 Hz suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC complete all as specified and as directed. Make: Sarada / Unistar
S & F in repairs Running Capacitor of 4/6 Mfd, 240 Volts, AC, 50 Hz suitable for Outdoor Unit 1.5 / 2.0 TR Capacity Split Type and Window Type AC complete all as specified and as directed. Make: Sarada / Unistar
S & F in repairs Starting Relay suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC complete all as specified and as directed. Make: Aravind / Shriram
S & F in repairs Thermostatic Switch suitable for 1.5 / 2.0 TR Capacity Window Type AC complete all as specified and as directed. Make: Ranco / Danfoss / Honeywell / Indfoss
S & F in repairs Insulated Drain Pipe suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed.
S & F in repairs Capillary Tube Set suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed.
S & F in repairs MS Stand Suitable for Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make, fixing with Anchor Fastner, Nut, Bolts and Rubber Bushes complete all as specified and as directed.
M & L for taking down the Burnt Fan Motor and Rewinding, Overhauling, replacement of worn out Shaft & Bushes and fixing to the Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed.
M & L for taking down the Burnt Fan Motor and Rewinding, Overhauling, replacement of worn out Shaft & Bushes and fixing to the Outdoor Unit of 1.5 / 2.0 TR Capacity Window Type AC of any make complete all as specified and as directed.
Supply only Remote Control Unit Suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make, complete all as specified and as directed.
S & F in repairs Condenser Fan Motor of Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed.
S & F in repairs New Wiring Kit Suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC of any make, including testing & commissioning the unit complete all as specified as directed.
M & L for taking down by disconnecting Water Connections and shifting Water Coolers up to 120 Litres capacity to Workshop, taking down the defective sealed compressor and replace with New Compressor including flushing the complete system of Condenser, Cooling Coil with Nitrogen Gas, removal all Carbon, Oil & Dirt, Brazing & connecting the Refrigeration Lines, Dehydrating, Purging with Refrigerant, Vacuumising and charging with R22/134 Refrigerant Gas and testing & commissioning and shifting to original location and connecting up the electrical & water connections complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson
M & L taking down by disconnecting Water Connections of Water Coolers up to 120 Litres capacity for complete tinkering the corroded Sheet Metal Parts, Side Panel, Door and renewal of the Bottom Base Plate, Mounting Legs, Fan Motor Base Plate and Condenser Cover etc., with existing Size & Gauge GI Sheet, with required Angle Iron, Nut, Bolts all as per the existing size and shape including Cutting, Bending, Welding and fixing all other components and nesting the hole of watertight and making the door properly sit without any gap including float set and washer complete scraping old paint, prepare the surfaces, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size including complete cleaning the Water Tank and shifting to the original location and testing complete all as specified and as directed.
M & L for taking down 40/80 Litres capacity Water Coolers, transporting to workshop flushing out the Cooling Coil, Condenser, Brazing the Refrigerant Lines, replacing the Liquid Line, Copper Strainer, Leak Testing, Purging with Refrigerant, Vacuumising and Charging of R22 Gas, testing & commissioning and shifting of the location and connecting up the Electrical & Water connections etc. complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson
All as per Serial Item No. 30 above but 60/120 Litres capacity Water Coolers complete all as specified and as directed.
M & L for painting the Water Coolers of Capacity up to 120 Litres including scraping old paint, prepare the surfaces, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size including complete cleaning the Water Tank and shifting to the original location and testing complete all as specified and as directed.
M & L for dismantling the Water Coolers up to 120 Litres capacity, checking for the leaks by pressure testing and carrying out the lead soldering to Cooling Coil and the tank outer surface wherever found detached including rectifying the leakages and re-assembling the Water Cooler complete all as specified and as directed.
S & F in repairs Starting Relay suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Aravind / Shriram
S & F in repairs Over Load Relay suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Aravind / Shriram
S & F in repairs Running Capacitor 20/10 Mfd, 440 Volts, AC, 50 Hz suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Sarada / Unistar
S & F in repairs Starting Capacitor 60/80 Mfd, 240 Volts, 270 SU, 50 Hz suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Sarada / Unistar
S & F in repairs Thermostatic Switch suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Annapurna / Rantro / Indfoss
S & F in repairs Chromium Plated Lift / Push Type Bib Cock of 15mm bore suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed.
S & F in repairs Brass Float Valve of 15mm bore suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed.
S & F in repairs Drain Connection and Drain Pipe with necessary Clamps, Nipple, Coupling etc., suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed.
S & F in repairs Fan Motor suitable for 40 /80 & 60 / 120 Litres Capacity Water Coolers complete all as specified and as directed.
S & F in repairs Fan Blade suitable for 40 /80 & 60 / 120 Litres Capacity Water Coolers complete all as specified and as directed.
S & F in repairs Air Cooled Condenser with necessary brackets and fixing arrangements including welding brazing etc., suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed.
S & F Sealed Compressor suitable for Refrigerator of 180/230 Litres Capacity, Flushing out the Cooling Coil, Condenser, brazing the Refrigerant Lines, Leak Testing, Pressure Testing, Purging, Vacuumising, Charging of Gas, Testing & Commissioning including taking down the defective sealed compressor complete all as specified and as directed. Make: LG / Hitachi / Indfoss
All as per Serial Item No. 45 above but Refrigerator of 280 Litres capacity complete all as specified and as directed.
S & F in repairs Relay suitable for Refrigerator up to 230 Litres Capacity complete all as specified and as directed. Make: As per OEM
S & F in repairs Thermostatic Switch suitable for Refrigerator up to 230 Litres Capacity complete all as specified and as directed. Make: As per OEM
S & F in repairs, Single Pole Contactor of Capacity 30 Amps, 240 Volts, 50 Hz suitable for Split / Window type ACs complete all as specified and as directed.
S & F Sheet Metal Body of Outdoor unit of 1.5 TR capacity Split AC Unit of any Make / Model including taking down and dismantling the components and reassembling and fixing to the existing location and testing for complete all as specified and as directed.
All as per Serial Item No. 50 above but 2.0 TR capacity Split AC Unit of any Make / Model complete all as specified and as directed.
S & F in repairs Air Cooled Condenser suitable for 1.5 TR capacity Split AC Unit of any Make / Model and testing for complete all as specified and as directed.
All as per Serial Item No. 52 above but 2.0 TR capacity Split AC Unit of any Make / Model complete all as specified and as directed.
Supply & filling Refrigerant Gas R-22 / R32 / R410 A for charging of Split / Window type AC, Refrigerator / Deep Freezer and Water Cooler of any capacity and any make complete all as specified and directed.
Taking down Split Air Conditioner including Outdoor unit of any description from its position and refixing the same at same place or at new place including connecting up, cleaning, carrying out minor repairs and replacement of Nuts & Bolts etc. including MS Stand / Bracket suitable for fixing Outdoor Units of Split ACs of different capacities, recharging with suitable Refrigerant Gas as required and necessary scaffolding etc. for complete all as specified and as directed.
S & F in repairs 3/8" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed.
S & F in repairs 1/4" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed.
S & Fixing in repairs 4 Core, PVC Insulated, Sheathed Flexible Copper Conductor Cable of size 4 Sq.mm and connecting up Air Conditioners of any type and Capacity complete all as specified and as directed.
M&L for carrying out the complete servicing to Window Type ACs including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carrying out the chemical cleaning to chocked Cooling Coil & Condenser Coil, by spraying the Dilated Chemical Cleaning Agent till removal of complete chocking, flushing across the Coils, cleaning all the Sheet Metal Parts, Filter, Grill and fixing all the dismantled parts with Sheet Metal Screws, lubricating the fan Motor Bush / Bearing, checking all the Electrical Connections, renewing the Burned Legs/Clip if any and fixing back to position and testing complete all as specified and as directed. Note: Servicing to be done by air blower and dust cleaner machines.
All as per Serial Item No. 59 above but for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed.
S & F in repairs Suction and Liquid Line Insulation, Thermo Foam, Pipe Section Type, suitable for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed.
S & F in repairs PVC Air Filter Set of 3 suitable for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed.
S & F in repairs Powder Coated Sheet Metal Body Outer Cover Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit complete all as specified as directed.
S & F in repairs Condenser Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit including necessary piping and brazing complete all as specified as directed.
S & F in repairs Evaporator Coil Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit including necessary piping and brazing complete all as specified as directed.
S & F in repairs Front Decorative Grill Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, complete all as specified as directed.
S & F in repairs Fan Motor Double End Shaft Type Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, complete all as specified as directed.
M & L for taking down the Defective Deep Freezer of 300 Litres capacity, shifting to work shop, taking out the defective Sealed Compressor from the unit and replacing the compressor with the Factory Reconditioned Compressor of the same Make and Capacity, flushing out the Cooling Coils and Condenser with CO2 / Nitrogen Gas, removal of complete Oil and Carbon Chocking, Brazing Lines interconnection, renewal of the Drier Filter, Pressure Testing, Vacuumising, Dehydration, Charging of R-134a Gas, testing at work shop and transportation back to the site and refixing the Deep Freezer in its original position complete all as specified and as directed. Make: LG / Danfoss
All as per Serial Item No. 68 above but Deep Freezer of 500 Litres Capacity complete all as specified and as directed.
S & F in repairs Fan Motor with Fan Blades suitable for 425 Litres Capacity Deep Freezer complete all as specified and as directed.
S & F in repairs Electronic wall mounted time delay Voltage stabilizer of 5 KVA Capacity, Automatic Operation, for input variation of 170 Volts to 270 Volts with stabilised voltage of 230 Volts with accuracy of ± 2.5% complete all as specified and as directed Make: V Guard / Servo / Kee Line
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
S & F in repairs Capacitors of 2.5 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal
S & F in repairs Capacitors of 4.0 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal
Dismantling the Ceiling Fan and its Allied Minor Spares / Parts and taking out the Bearings / Bushes and refixing the same with all the parts i.e. Down Rod, Canopies, Fan Blades etc. replacing the damaged Spilt Pins and Screws, Nuts and Spring Washers [for Blade/Body] including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm as required complete all as specified and as directed. Note: Supply only spares like Bearings / Bushes, Blades, Down Rod, Capacitor, Shackle & Clamp and Canopy shall be measured and paid separately as supply only under this BoQ. Rewinding of Fan Motor Shall also be measured and paid separately wherever ordered.
All as per Serial Item No. 75 above, but Exhaust Fan of any Sweep complete all as specified and as directed.
All as per Serial Item No. 75 above but Air Circulator of any Sweep complete all as specified and as directed.
All as per Serial Item No. 75 above, but Wall Mounted Fan of any Sweep complete all as specified and as directed.
All as per Serial Item No. 75 above but Pedestal Fan of any Sweep complete all as specified and as directed.
M & L for Rewinding of Motor of Ceiling Fan of 1200mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Ceiling Fan of 1400mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Exhaust Fan of 300mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Exhaust Fan of 400 / 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Wall Mounted Fan of 400 / 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Air Circulator / Pedestal Fan of 400 / 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Flame Proof Ceiling Fan of any Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Flame Proof Exhaust Fan of 300 to 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
M & L for Rewinding of Motor of Flame Proof Wall Mounted Fan / Air Circulator of any Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed.
Supply only Ball Bearing No. 6201 / 6202 suitable for Ceiling Fan / Exhaust Fan / Wall Mounted Fan / Air Circulator / Pedestal Fan of any Sweep and any description complete all as specified and directed. Make: TATA / SKF / NBC
Supply only Ball Bearing No. 6203 / 6204 suitable for Ceiling Fan / Exhaust Fan / Wall Mounted Fan / Air Circulator / Pedestal Fan of any Sweep and any description complete all as specified and directed. Make: TATA / SKF / NBC
Supply only Capacitors of 2.5 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal
Supply only Capacitors of 4.0 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal
Supply only Gun Metal Bush of any size complete all as specified and directed. Make: TATA / MSP
Supply only Shackle & Clamps including, Rubber Bush, Bolts, Nuts & Split Pin etc. complete suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed.
Supply only MS Down Rod of size 15 mm bore, 500mm Long including making Two No. of Holes on either ends suitable for fixing Bolts of 8mm Dia suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed.
S & F in repairs Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
M & L for preparation of surfaces of Ceiling Fan of any Sweep and applying One Coat of Synthetic Enamel Paint of approved colour and Writing MES Serial Number as per Standard Format Complete all as specified and as directed.
M & L for preparation of surfaces of Exhaust Fan of any Sweep and applying One Coat of Synthetic Enamel Paint of approved colour and Writing MES Serial Number as per Standard Format Complete all as specified and as directed.
S & F in repairs MS Louvers / Shutters suitable for Exhaust Fan of any Size / Sweep including preparation of surfaces and applying Two Coats of Synthetic Enamel Paint of approved colour over a coat of Red Oxide / Zinc Chrome Primer Complete all as specified and as directed
Supply only Three Core, PVC insulated, sheathed flexible Copper Conductor Cable of size 1.5 Sq.mm, 1100 Volts Grade complete all as specified and as directed.
M & L for Comprehensive Repair / Maintenance of Storage Type Electric Water Heater [Geyser] Vertical or Horizontal type of Capacity 25 Litres comprising of the following: [a] Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank complete to the satisfaction of the User / Engineer-in-Charge. [b] Checking of all Stop Cock, Pressure Release Valves, Fusible Plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the Washers / Gasket, Nuts etc. [c] Checking and rectifying Earth Continuity of the Electrical Circuits of the Geysers and Power Point. [d] Checking and re-fixing Thermostat and re-adjusting. [e] De-scaling the Immersion Type Heating Element and Siphon Assembly with diluted Hydrochloric Acid or clear Pedette Solution. [f] Checking of Indicator Lamp for its serviceability. [g] Re-assembling the Geyser, re-installing and testing complete. Note: Spares / Parts / Components of Geysers found unserviceable shall be replaced by the contractor. New Spares / Parts / Components as required shall be measured and paid separately under respective Items of this BoQ as supply only.
M & L for Comprehensive Repair / Maintenance of Solar Water Heater [Geyser], Vertical or Horizontal type of Capacity 100 / 500 Litres comprising of the following: [a] Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank complete to the satisfaction of the User / Engineer-in-Charge. [b] Checking of all Stop Cock, Pressure Release Valves, Fusible Plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the Washers / Gasket, Nuts etc. [c] Checking and re-fixing Solar Flat Plate Collector / Tube Collector and re-adjusting as required. [d] De-scaling the Immersion Type Heating Element with diluted Hydrochloric Acid or clear Pedate Solution. [f] Re-assembling the Solar Water Heater Tank, Solar Water Tube Collector / Flat Plate Collector re-installing and testing complete. Note: Spares / Parts / Components of Geysers found unserviceable shall be replaced by the contractor. New Spares / Parts / Components as required shall be measured and paid separately under respective Items of this BoQ as supply only.
Supply only Thermostat including Rubber / PVC Gasket Tube Set to a Temperature not higher than the range of 70°C suitable for 25/50 Litres Capacity Geyser complete all as specified and as directed.
Supply only Thermostat including Rubber / PVC Gasket Tube Set to a Temperature not higher than the range of 70°C suitable for 100 / 500 Litres Capacity Geyser complete all as specified and as directed.
Supply only Heating Element of capacity 2.0 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed.
Supply only Heating Element of capacity 3.0 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed.
Supply only Heating Element of capacity 1.5 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed.
Supply only Copper Syphon Assembly suitable for 25 Litre Capacity Geysers of any make as required at site / as per existing Model / Make complete with Inlet and Outlet and provision for Thermostat Pipe with Drain Pipes with Drain Plug, Screws, Studs, Clamps for fixing Heating Elements etc. including Gasket complete all as specified and as directed.
Supply only Plug Top 3 Pin, 16 Amps, 240 Volts complete all as specified and as directed.
Supply only 3 Core, PVC Insulated, Sheathed Flexible Copper Conductor Cable of size 2.5 Sq.mm suitable for connecting up Geyser complete all as specified and as directed.
Supply only LED Neon type Indicating Lamp [Green / Red], 240 Volts, AC, 50 Hz suitable for Geysers complete all as specified and as directed.
Supply only Safety Valve suitable for 25/50 Litres Capacity Geyser complete all as specified and as directed.
Supply only Plug Top 3 Pin, 20 Amps, 240 Volts complete all as specified and as directed.
M & L for Detecting and Arresting of leakage in Storage Tank of 25 Litres Capacity Geysers by Brazing and Soldering at leakage point and testing complete all as specified and as directed.
M & L for preparation of surface of 25 Litres Capacity Geysers by scrapping and applying One Coat of Synthetic Enamel Paint of approved colour over a coat of Red Oxide / Zinc Chrome Primer complete all as specified and as directed.
S & F in repairs PVC Connection for Hot & Cold Water of 15mm Bore and 450mm long with PTMT check nut and union etc complete all as specified and as directed.
S & F in repairs PVC Connection for Hot & Cold Water of 15mm Bore and 600mm long with PTMT check nut and union etc complete all as specified and as directed.
S & F in repairs Non Return Valve, Cast Copper Alloy, Capstan Head, Chromium Plated, Fancy Type, 15 mm dia, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as specified and as directed.
Supply only Anchor Bolt of size 10mm dia and 100mm Long Bolt including Nut, Washer for mounting the Geyser complete all as specified and as directed.
S & F Energy efficient, BEE 5 Star rated Storage type Water Heater [Geyser] of 25 Litres Capacity with 2000 Watt Capacity Heating Element, Conforming to IS - 2082, Vertical Storage type with Stainless Steel Inner Tank and ABS Outer Shell complete fixed to wall with suitable expansion fasteners including 15mm dia PVC Flexible Hot & Cold Water connections and 15mm bore Brass Chromium Plated Non-Return Valve including taking out old unserviceable Geyser and depositing to MES Store Yard complete as specified and as directed. Make: Bajaj / Usha / Crompton Greaves / Jaquar
Supply only MS Hooks of required size suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed.
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 373, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, of approved colour including Down Rod, Canopies, 3 Nos. Blades, Shackles, Safety Rope, Hanging Clamps, Bushes and having P.F >0.94, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% with speed control by Electronic Regulator including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Ceiling Fan of any description and depositing at MES Store Yard complete all as specified and as directed.
S & F Wall Mounted Fan, 400mm Sweep, Metal Body, Heavy duty, 230 Volts, AC, 50 Hz, Wall Mounting Type including speed control set and taking down existing exhaust fan of any description and depositing at MES Store Yard complete all as specified and as directed. . Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
S & F Pedestal Fan, 450mm Sweep, 2100 RPM, Aerodynamic ABS Blades to deliver higher Air Flow, Heavy Duty, with Double Ball Bearing, Conforming to IS - 1169, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, BEE 5 Star Rated and of approved colour and taking down existing exhaust fan of any description and depositing at MES Store Yard complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
S & F Exhaust Fan, 250mm Sweep, 1400 RPM, PVC Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing exhaust fan of any description and depositing at MES Store Yard complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
S & F Exhaust Fan, 300mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing Exhaust Fan of any description and depositing at MES Store Yard complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
S & F Exhaust Fan, 450mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing Exhaust Fan of any description and depositing at MES Store Yard complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
S & F AC Single Phase Static Electronic KWH Energy Meter of Accuracy Class 1.0, 240 Volts, 50 Hz, with Backlite LCD Display, Optical Port of Rating 10-60 Amps including taking out old unserviceable Energy Meter and depositing to MES Store Yard complete as specified and as directed.
S & F AC Three Phase Static Electronic KWH Energy Meter of Accuracy Class 1.0, 415 Volts, 50 Hz, with Backlite LCD Display, Optical Port of Rating 10-60 Amps including taking out old unserviceable Energy Meter and depositing to MES Store Yard complete as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 20 mm dia including all accessories surface type / semi concealed type including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for Flame Proof Application of One Light / Fan Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 130 above but One 3 Pin Switch Socket Outlet 16 Amps on Independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts including Rubber Gasket as per IS – 2149, ISI marked for ON/OFF Light, CMRI certified with cable entries complete all as specified and as directed.
Taking down existing serviceable Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth complete all as specified and as directed.
Taking down existing serviceable Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
S & F in repairs Flame Proof Junction Boxes 2/3/4 Way suitable for 20 mm dia ERW Steel Conduit complete all as specified and as directed.
S & F in repairs Flame Proof, LED Light Fitting 2 X 16 Watt, CMRI certified recommended for Gas / Vapor Group of IIA & IIIB, Zone 1 & 2 and IP 65 Protection with Die Cast Aluminium Housing with Heat Resistant Toughened Glass with LED Tube Light Fixtures, Driver, Holders, Connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F in repairs Flame Proof / Whether Proof Well Glass LED Light Fitting suitable for 60 Watt LED as per IS – 13947, body made out of Aluminium Alloy LM-6 Epoxy Painted with Guard, Reflector, Flameproof Clear Glass complete all accessories prewired CIMFR certified Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
Taking down unserviceable 40 / 20 / 10 Watt Flame Proof / Whether Proof Tube Light Fittings and carrying out repairs as required and replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
Supply Only 18/20 W LED Master Tube Rod complete all as specified and as directed.
Supply Only LED Lamp 22 / 24 Watt complete all as specified and as directed.
Supply Only LED Lamp 16 / 18 Watt complete all as specified and as directed.
Supply Only Holder suitable for FLP Well Glass complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified.
S & F MCB, FP, 40 to 63 Amps, 10 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, DP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 1.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 1.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
S & F in repairs 36/42 W LED Power Driver for Down Lighters complete all as specified and as directed.
Testing of Earth Resistance of existing Earth Pit as directed by the Engineer-in-Charge as and when required using Earth Resistance Testing Equipment and producing the Test Results and maintaining suitable records complete all as specified and as directed. Note: The contractor shall be asked to carry out the Earth Test as and when required basis as per the site / user requirement. Testing of each Earth Pit shall be measured as one unit. All test results shall be entered in a suitable Register and shall be submitted to the Engineer-in-Charge. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis. Nothing shall be paid extra on this account.
M & L for Replacement of Broken RCC Cover by new 50 mm thick Precast RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways and suitable Handle made of 10 mm dia Round Bar and other allied works complete all as specified and as directed.
Taking down Earth Strip from Earth Pit and testing of resistance of existing Earth Pit of Lightening Conductor for its continuity by Highly Skilled Electrician / Technician using Digital Earth Resistance Tester including checking the healthiness of earthing system and replacing Nut, Bolt with Brass Nut, Bolts as per required size and providing all Tools and Testing Apparatus including rectification of the Discontinuity by providing new Lightening Conductor or refixing the displaced existing Lightening Conductor in place as required including necessary minor repair work as required during rectification complete all as specified and as directed. Note: Testing of each Earth Pit shall be measured as One Unit and shall be carried out on priority as and when required basis. The Test Results shall be submitted to the Engineer-in-Charge and User duly signed by all concerned before claiming payment. All the materials required to complete the work at site such as wooden Plugs, Nut, Bolt, Washers, Saddles, fixing Screws etc. shall be provided by the contractor at No extra cost to the Government. Water and Salt as required in the Earth Pit shall be provided by the contractor. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis and all the consumables as specified hereinabove. Nothing shall be paid extra on this account. Air Terminal, GI / Aluminium Strip shall be measured and paid separately.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc. complete all as specified and as directed.
Taking out and Re-fixing of Old Serviceable Tilted Air Termination Rod of any size and type after Straightening & Dressing with and including suitable Nut, Bolts and Washers to Earth Strip complete all as specified and as directed.
S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of Copper Strip of size 20 X 3.15mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Taking down old Copper / GI / Aluminium Strip of any size and any type from Building / Hangar [Roof / Down Conductor] / Pipe / Trench and Re-fixing the serviceable Copper / GI / Aluminium Strip of any size and type after Straightening & Dressing with and including Saddles / Insulators with Screws for fixing and making good disturbed surfaces complete all as specified and directed.
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc. with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
M & L for Earthing complete with CI Earth Pipe Electrode with Flanged ends, Centrifugally Cast, Class "A'', Heavy Duty, 80 mm dia all as per IS – 1536 of 2.50m length burried directly and preferably vertically in ground with top edge of the Pipe not less than 2.00 metres below Natural Ground Level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Pipe Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, Drilling 400mm dia Bore Hole in any type of strata by suitable means for lowering the CI Pipe, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4mm GI Wire [Earth Lead] and GI Pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Switch Piano, Flush Button, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs Switch Socket Outlet, 3 & 2 Pin, Multipurpose, 6 Amps, 230 Volts, Flush Type complete all as specified and as directed.
S & F in repairs Switch Socket Outlet, Multipurpose, 3 pin, 16 Amps and 3 pin, 6 Amps, Flush Type, 230 Volts controlled by One Switch complete all as specified and as directed.
S & F in repairs Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
Taking down unserviceable 40 Watt Tube Light Fitting / 20 Watt LED Tube Light Fitting and repair / replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1000 Lumens output, 5700K of cool white, with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of cool white, with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient T8 LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of Cool White, including T8 LED Tube with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs LED Power Driver for Downlighters suitable for 36 / 42 Watt, 240 Volts, Single Phase AC Supply, 50 Hz complete all as specified and as directed.
S & F in repairs LED Power Driver for Downlighters suitable for 24 Watt, 240 Volts, Single Phase AC Supply, 50 Hz complete all as specified and as directed.
Taking down unserviceable Post Top Lantern / Gate Light of any type / description and repair / replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Lamp Holder, Insulated Body with Back Plate, 230 Volts for Batten Fittings including LED Bulb of not less than 1000 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour complete all as specified and as directed.
S & F New generation, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed LED Landscape Luminaire / Integral LED Bollard for Downward Lighting with High Power LED as light source, Decorative Pyramid Tripod type, of not less than 1000 Lumens output, Outdoor type, 5700 K, with Pressure Die Cast Aluminium Housing with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including PCC 1:2:4, Type B1 foundation for fixing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. Make: Model / Catalogue No. LBLSN-10-CDL of Crompton Greaves or its Equivalent Model in Philips / Havells / Wipro / GE / Bajaj / Jaquar
S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 4' X 1' Grid False Ceiling of not less than 3600 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. Make: Model / Catalogue No. MUSHROOMBL16WLED730 SSYMTOPC of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar
S & F in repairs Factory made FRP Junction Box of size 155 X 210 X 92mm with IP 66 Protection and including MCB, SP, 16 Amps, C Curve, 240 Volts [1 Nos] and one number heavy duty Four Way Connector for incomer and outgoing cable, suitable for Pole mounting and fixed with clamps made out of 40 X 3mm flat iron with suitable nuts, bolts, gland lugs etc. duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply, lay, test and commissioning of 3 Core, 2.5 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including crimping type cable lugs, sockets etc. and connecting complete all as specified and as directed.
Supply, lay, test and commissioning of 3 Core, 4.0 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including crimping type cable lugs, sockets etc. and connecting complete all as specified and as directed.
S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F in repairs Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F in repairs Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 3 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 6 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 8 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
Taking down / Dismantling the Electrical Connection from Rolling Shutter with Gearbox Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor and Gearbox for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing with Gearbox and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor and Gearbox Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment with Main Shaft, Speed Reducing Gearbox Assembly and Greasing, servicing and filling of New Gear Oil for smooth functioning of the system complete and testing and commissioning the Rolling Shutter complete all as specified and as directed.
Taking down / Dismantling the Electrical Connection from Electric Siren Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment and servicing for smooth functioning of the system complete and testing and commissioning the Electric Siren complete all as specified and as directed.
M &L for checking the serviceability including loose contact and condition of cable terminations of all the existing MCB MCCB DBs / Flame Proof DBs at any building/any place once in three months and opening a DB serviceability register and recording building wise including obtaining users signature in the register complete all as specified and as directed. Note: The checking shall be carried out in presence of user. One time checking including entering in the register is considered as one job.
S & F New generation, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed with Symmetrical Light Distribution LED Landscape Luminaire / Post Top Lantern with High Power LED as light source, of not less than 4000 Lumens output, Outdoor type, 5700 K, with Spun Aluminium with Clear Cover Housing, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. Make: Model / Catalogue No. VICTORIAPT35WLED730PSYMTOTG of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar
S & F Energy efficient LED Flood Light fitting, of not less than 12000 Lumens output, 6500 K, with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient & Long life Building Security Light Luminaire / Street Light Luminaire, of not less than 2500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs 20 Watt Inverter Rechargeable Emergency LED Light with 2400 Mah Powerful Battery, Energy Efficient, Recharging Time 4-6 Hours, Power Backup up to 4 Hours complete all as specified and as directed.
F AND M TECHNOLOGIES (BID ID -3335522)
LAKSHMI SAI CONSTRUCTIONS (BID ID -3336858)
ANAND ENTERPRISES AND ENGINEERS (BID ID -3344559)
SRI RAJA RAJESWARI ENTERPRISES (BID ID -3336513)
Bidder Name
suresh electricals
ANAND ENTERPRISES AND ENGINEERS
SRI RAJA RAJESWARI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .