Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being the lowest bidder. | |
| 2 | L2₹38.8 L+₹1.9 L (5.04%)Rejected-AOC 21 A MALVIYA NAGAR AIR FORCE AREA JODHPUR RAJASTHAN 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹39.8 L+₹2.9 L (7.78%)Rejected-AOC | L3 | Rejected-AOC Not L1. | |
| 4 | L4₹40.7 L+₹3.8 L (10.2%)Rejected-AOC MANOBAL 236 VARDMAN NAGAR SHOBAWATO KI DHANI PAL ROAD JODHPUR | L4 | Rejected-AOC Not L1 |
| Sl No | Description | Qty | Unit | M/S KAUTILYA GARG L1 | C K Industries L3 | AMAN ASSOCIATES L4 | CHOUDHARY CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling chain link fencing of any description fixed to any type of fencing posts complete all as specified and directed. | 1,350 | SQM | 10 ₹13,500 | 5 ₹6,750 Lowest | 8 ₹10,800 | 10 ₹13,500 |
| 2.00 | Supply only chain link mild steel galvanised fencing, any type and size complete all as specified and directed by Engineer-in-Charge. | 1,687.5 | KG | 110 ₹1,85,625 | 145 ₹2,44,687.5 | 80 ₹1,35,000 Lowest | 120 ₹2,02,500 |
| 3.00 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire omplete all as specified and directed by Engineer-in-Charge. | 1,350 | SQM | 30 ₹40,500 | 10 ₹13,500 Lowest | 80 ₹1,08,000 | 20 ₹27,000 |
| 4.00 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion concrete, brick work, masonry, etc. and making good disturbed ground complete all as specified and directed. | 420 | RM | 10 ₹4,200 Lowest | 15 ₹6,300 | 40 ₹16,800 | 100 ₹42,000 |
| 5.00 | Excavation in post holes (or similar holes) each n. exc. 0.5 cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surfaces in soft/ loose soil complete all as specified and directed. | 200 | EACH | 100 ₹20,000 | 25 ₹5,000 Lowest | 56 ₹11,200 | 50 ₹10,000 |
| 6.00 | M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregates) in foundation, sub base, filling and mass concrete complete all as specified and directed. | 30 | CUM | 2,500 ₹75,000 | 2,750 ₹82,500 | 2,160 ₹64,800 Lowest | 3,200 ₹96,000 |
| 7.00 | S&F angles in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. | 3,828 | KG | 100 ₹3,82,800 | 105 ₹4,01,940 | 80 ₹3,06,240 Lowest | 110 ₹4,21,080 |
| 8.00 | S&F MS flat iron for securing the chain link fencing including necessary drilling for holes, cutting, punching, bending etc. complete all as specified and directed. | 508 | KG | 100 ₹50,800 | 90 ₹45,720 | 80 ₹40,640 Lowest | 90 ₹45,720 |
| 9.00 | S&F 12 mm dia round bars in available lengths, Fe-290 (Gde E-165) complete all as specified and directed. | 1,600 | KG | 80 ₹1,28,000 Lowest | 100 ₹1,60,000 | 80 ₹1,28,000 Lowest | 85 ₹1,36,000 |
| 10.00 | S&F 5 to 10 mm dia mild steel bolts (machine made) with hexagonal or square head at one end and screwed the other with washers and one hexagonal or square not exc. 10 cm long.complete all as specified and directed. | 37.04 | KG | 80 ₹2,962.96 Lowest | 100 ₹3,703.7 | 80 ₹2,962.96 Lowest | 150 ₹5,555.56 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jul 2025, 6:00 pmClosed
GE AF JODHPUR
GE (AF) Jodhpur
REPAIR TO PATH HARD STANDING FENCING ROOF TREATMENT FLOORING WALL AND FALSE CEILING AND OTHER MISC WORKS AT SITE 1A AND 1B OF SU UNDER AGE BR I AT AF STN JODHPUR
2025_MES_714544_1
8425/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JODHPUR
₹90,000
Yes
9 Aug 2025
14 Jun 2025
17 Jul 2025
14 Jun 2025
15 Jul 2025
28 Jun 2025
Amount
Dismantling chain link fencing of any description fixed to any type of fencing posts complete all as specified and directed.
Supply only chain link mild steel galvanised fencing, any type and size complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire omplete all as specified and directed by Engineer-in-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion concrete, brick work, masonry, etc. and making good disturbed ground complete all as specified and directed.
Excavation in post holes (or similar holes) each n. exc. 0.5 cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surfaces in soft/ loose soil complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregates) in foundation, sub base, filling and mass concrete complete all as specified and directed.
S&F angles in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F MS flat iron for securing the chain link fencing including necessary drilling for holes, cutting, punching, bending etc. complete all as specified and directed.
S&F 12 mm dia round bars in available lengths, Fe-290 (Gde E-165) complete all as specified and directed.
S&F 5 to 10 mm dia mild steel bolts (machine made) with hexagonal or square head at one end and screwed the other with washers and one hexagonal or square not exc. 10 cm long.complete all as specified and directed.
M&L for preparation of new steel surface of any description, over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st quality) over one coat of red oxide primer complete all as specified and as directed.
S&F in repairs galvanized 2 strand steel barbed wire 2.20 to 2.24 mm dia barbed with 2mm dia barbs @ 75-85 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings etc. complete all as specified and directed.
Re-fixing galvanized 2 strand steel barbed wire 2.20 to 2.24 mm dia barbed with 2mm dia barbs @ 75-85 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings etc. complete all as specified and directed.
S&F in repairs galvanised steel punched type concertina coil of 1050 mm dia (dia of coil when unstretched) (weight of the concertina coil not less than 14 Kg and opening length should be 8.0m) and fixed to angle iron post/ struts with 3.15mm dia GI wire complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork of stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for walling of squared rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and directed.
M&L for 15 mm thick rendering on stone masonary or other than fair face of brick work finished even and smooth without using extra cement in CM (1:4) complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats exterior weather proof water base emulsion paint, over a coat of chalk whiting complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L for preparation of new concrete surfaces as in road side kerbs and applying two coats of synthethic enamel paint of approved different tints and pattern over a coat of primer etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing debris outside the premises complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick cement concerete (1:2:4) type B2 (using 20mm graded stone aggragetes) in alternate bays all as specified and directed.
M&L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compund grade "B' complete all as specified and as directed.
M&L for forming construction joints 30 mm deep x 10 mm wide, filled with sealing compund grade "B' complete all as specified and as directed.
Providing broom finished surface of concrete pavement while concrete is green complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in sub base floor/ floors and paving etc. complete all as specified and directed.
S&F rubber moulded machine pressed PCC interlocking paver block confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment laid dry over and including 25mm thick screed river washed sand cushion as in floor, shape and colour as directed by Engr-in-Charge.
M&L for 25mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregates) as in sub base for tiles in floors complete all as specified and directed.
Demolition of stone slabs and tiles laid in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 15 mm thick in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for heavy duty parking coloured tiles 25cm x 25cm x 10mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 15mm thick screed in CM (1:6) complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregates) as in sub base floor/ floors and paving etc.complete all as specified and directed.
S&F chequered cement concrete tiles 25 mm thick of any size, colour and pattern as approved, jointed and pointed in neat cement slurry in floors over and including15mm thick screed bed in CM (1:6) with grey cement and pigments complete all as specified and directed.
Dismantting of AC/ CGI/ fibre glass sheet corrugated/ semi corrugated sheet & ridge in roof covering complete all as specified and directed.
S&F pre-painted galvalume sheet as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site complete all as specified and directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde-E-250) Quality-B complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling framed work in timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section, in any position complete all as specified and directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
M&L for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
M&L for cleaning of SWT of any capacity including removing vegetations and taking out sludge and removing the sludge to a distance exc 1.5 KM but not exceeding 2.00 KM from the camp area complete all as specified and directed by Engr-in-Charge.
Dismatling floor hearth or wall tiling including cement mortor bedding but not backing removing serviceable tiles to store and rubbish off the premise complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in levelling course finished even and fair for laying floor finishes etc. complete all as specified and directed by the Engineer-in-Charge.
M&L for vitrified ceramic tiles 9mm to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointing in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for vitrified ceramic tiles 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm as in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engr-in-Charge.
Taking down old existing roof treatment (APP membrane) and removing from site complete all as specified and as directed.
Demolition of cement concrete of any type, description and in any position complete including removing debris outside the premises complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed.
M&L for brushing neat cement slurry with 3 kg of cement per Sqm complete all as specified and directed.
M&L for min 40 mm thick cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregates) in padding, finishing surface of concrete topping even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick plastering in CM (1:3) on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately as "supply only".
Supply only integral water proofing compound, ISI Marked complete all as specified and directed.
M&L for applying APP modified membrane (minimum 3 mm thick), it shall be taken upto height of minimum 300mm and shall be inserted inside a groove cut in the parapet and fixed. If the height of parapet is 300mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface to the parapet. For RCC inverted beam, the whole beam shall be covered with membrane irrespective of the depth. In case of roof projection, the membrane shall be taken 50mm on the reverse side of roof at the edges.with non-woven polyster reinforcement/ mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 75mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
M&L for providing cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Disconnecting existing tanks of capacity 500 Litres to 1000 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. Note:- Cleaning repairing etc. shall be measured and paid separately.
Dismantling of existing water tank (PVC/ RCC/ AC) exc. 500 ltr but n. exc. 1000 Litres capacity and removing from site to store yard complete all as specified and as directed by Engr-in-Charge.
Dismantling of existing water tank (PVC/ RCC/ AC) exc. 250 Litres but n. exc. 500 Litres capacity and removing from site to store yard complete all as specified and as directed by Engr-in-Charge.
S&F 500 Litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball PTMT.valve high pressure with polythyne float and flynut complete complete all as specified and as directed.
S&F 1000 Litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball PTMT valve high pressure with polythyne float and flynut complete complete all as specified and as directed.
Demolition and breaking up 100/ 150mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete complete all as specified and as directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to wall of 110 mm dia complete all as specified and directed by Engr-in-Charge.
S&F for PVC (SWR) bend of 110 mm dia.complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm complete all as specified and directed.
S&F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls, celling or laid in floors complete all as specified and directed.
Refixing old steel tubing and connections in new or old position as in walls, ceiling or laid in floors etc. bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm complete all as specified and directed.
Refixing old steel tubing and connections in new or old position as in walls, ceiling or laid in floors etc. bore of pipe 20mm complete all as specified and directed.
S&F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls, celling or laid in floors complete all as specified and directed.
S&F in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 15 mm dia complete all as specified and as directed.
S&F in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm dia complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
S&F anodised aluminium snap grid frame work (600mm x 600 mm) for false ceiling complete all as specified and as directed.
S&F 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid for exposed metal frame ceiling complete all as specified and as directed. Note:- Frame work for ceiling shall be measured and paid separately.
M&L for preparation of new decorated plastered or unplastered surfaces of ceilling and applying two coat of oil bound distemper, white or tinted over a coat of white putty in patches as required complete all as specified and as directed by Engineer-in-Charge.
Taking down and refixing the earthing strip over the finished roof surfaces, fixed on batten or any other indicated situation complete all as specified and as directed by Engineer-in-Charge.
CHOUDHARY CONSTRUCTION CO (BID ID -3354056)
C K Industries (BID ID -3345977)
AMAN ASSOCIATES (BID ID -3359916)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .