Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2₹8.3 L+₹87,905 (11.8%)Rejected-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | L3₹8.7 L+₹1.3 L (17.2%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC Being other than the lowest bidder | |
| 4 | L4₹8.8 L+₹1.4 L (19.1%)Rejected-AOC | L4 | Rejected-AOC Being other than the lowest bidder | |
| 5 | L5₹11.3 L+₹3.9 L (52.0%)Rejected-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L5 | Rejected-AOC Being other than the lowest bidder |
Tender Value
₹14.8 L
EMD Value
₹29,700
Closing Date
29 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO CWE BLY/GE(EAST)/30 of 2020-20 REPAIR/ MAINT OF SUMMER APPLIANCE, REFRIGERATOR AND AC UNDER GE (EAST) BAREILLY
2020_MES_356419_1
8200/B/627/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
For enlisted contractor Class E Category b i and for unenlisted contractor meeting the eligibility criteria of class E and category b i
6 documents required · 6 mandatory
₹500
Yes
GE(East) Bareilly
₹29,700
Yes
9 Sept 2020
27 Jun 2020
3 Aug 2020
27 Jun 2020
29 Jul 2020
13 Jul 2020
27 Jun 2020 - 18 Jul 2020
60 days
Amount
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from window type A/C of any make including making necessary refrigerant pipe, elect connection , leakage testing, all as specified and directed for 1.5 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from window type A/C of any make including making necessary refrigerant pipe, elect connection , leakage testing, all as specified and directed for 2 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from split type A/C of any make including making necessary refrigerant pipe, elect connection , leakage testing, all as specified and directed for 2 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from split type A/C of any make including making necessary refrigerant pipe, elect connection , leakage testing, all as specified and directed for 1.5 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired ) suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 40/80 Ltrs any type and make, including making necessary refrigerant pipe, elect connections including making leak proof, all as specified and directed.
S&F hermetically sealed unit compressor (replaced with original company repaired ) suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 60/120 Ltrs any type and make, including making necessary refrigerant pipe, elect connections including making leak proof complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired ) suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 150 Ltrs any type and make, including making necessary refrigerant pipe, elect connections including making leak proof complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired ) suitable for working on SP 50 Hz AC supply after taking out carefully from refrigerator capacity 165 to 210 Ltrs any type and make, including making necessary refrigerant pipe, elect connections including making leak proof complete all as specified and as directed.
S&F hermetically sealed unit compressor (replaced with original company repaired ) suitable for working on SP 50 Hz AC supply after taking out carefully from refrigerator capacity 265 to 310 Ltrs any type and make, including making necessary refrigerant pipe, elect connections including making leak proof complete all as specified and as directed.
S&F 'V' belt of blower A-53 complete all as specified and as directed.
M&L for replacement of old unserviceable starting relay carefully from window/Split type A/C 1 to 2 TR capacity of any make including making necessary electric connections complete all as specified and as directed.
S&F 'V' belt of blower A-53 for water coolers 80 to 150 Ltr capacity complete all as specified and as directed.
S&F in repair for overload protector for water coolers 80 Ltr complete all as specified and as directed.
S&F in repair for overload protector for AC 1.5 TR/WC 120 Ltr capacity complete all as specified and as directed.
S&F in repair for overload protector for AC 2 TR/WC 150 Ltr capacity complete all as specified and as directed.
M&L for opening body of water cooler, taking out cooling tank to rectify leakage of refrigerant tube/condenser and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and directed.
M&L in repair for taking out burnt fan motor 1/6 or 1/7 HP from window type A/C of any size / capacity and replacement with new, providing insulation material, replacement of bushes/ shaft and refixing including making necessary electric connections complete all as specified and directed.
S&F in replacement fan blade alumium for window/split type A/C (1,1.5,2 TR capacity) complete all as specified and directed.
S&F in replacement blower motor split AC 1.5 TR in replacement of worn out unit complete all as specified and as directed.
S&F in replacement of warn out of existing unserviceable condenser unit with cooling coil cooper/alluminium fins split AC 1.5 TR complete all as specified and directed.
S&F in replacement blower motor split AC 2.0 TR in replacement of worn out unit complete all as specifird and directed.
S&F in replacement condenser unit with cooling coil cooper/alluminium fins ,wiring as per existing with connection for indoor and outdoor with copper tubing complete all as specified and directed.
S&F air cooled finned condenser suitable for water cooler of existing size and make complete all as specified and directed.
M&L for charging of refrigerant R-22 in window/split type A/C/Water cooler of any make (1.5 & 2 TR capacity) carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak proof including testing for leakage, and optimum grill temperature complete all as specified by the manufacturer and directed.
M&L for charging of refrigerant R-12 in refrigerant for water coolers any make refrigerator 165 to 310 ltrs carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak proof including testing for leakage, and optimum grill temperature complete all as specified by the manufacturer and directed.
M&L for scrapping out old bubbled paint, cleaning the surface, leveling, spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to desert cooler any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note:- painting will be carried out at site by bringing compressor machine rate quoted deemed to be included complete all as specified and directed.
M&L for scrapping out old bubbled paint, cleaning the surface, leveling, spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to water cooler any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note:- painting will be carried out at site by bringing compressor machine rate quoted deemed to be included complete all as specified and directed.
M&L for scrapping out old bubbled paint, cleaning the surface, leveling, spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to window/Split type A/C up to 2 TR capacity any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note:- painting will be carried out at site by bringing compressor machine rate quoted deemed to be included complete all as specified and directed.
M&L for servicing, cleaning, greasing, oiling , checking of electric wiring, relays, contactor etc and replacement of defective wiring of Window/ Split type AC (1.5 to 2 TR capacity) of any make by taking down from Window/Wall and refix to its existing position or reinstalled at different location complete all as specified and directed.
M&L for servicing, cleaning, greasing, oiling , checking of electric wiring, relays, contactor etc and replacement of defective wiring for Water cooler any make and type including taking down and refix to its existing position or reinstalled at different location complete all as specified and directed.
M&L for servicing, cleaning, greasing, oiling , checking of electric wiring, relays, contactor etc and replacement of defective wiring for refrigerator/ deepfreezers any make and type including taking down and refix to its existing position or reinstalled at different location complete all as specified and directed.
S&F in repair PVC flexible PVC drain pipe 1" dia 1.5 mtr long for drainage of water coolers of any make and type complete all as specified and directed.
S&F in replacement fan motor AC 230 V high speed suitable for split AC 1.5/2 ton for any Make of AC complete all as specified and directed.
S&F in replacement new remote assembly for split/widow type AC 1.5/2 ton of any make & existing model complete all as specified and directed.
S&F after taking out unserviceable defective PCB plate in 1.5/2 ton AC of any make and fixing new remote control kit/ PCB plate in existing position with all electric connections complete all as specified and directed.
Disconnecting and taking out existing defective MCB of any description & in any position and supplying and fixing new MCB, single pole, 240 volt, 32 Amps complete all as specified and directed.
Disconnecting & taking out existing defective industrial type Plug top of any description & in any Position and supplying and fixing new Plug Top metallic industrial type, 2Pole+earths, 20 Amps, 240 volts complete all as specified and directed.
Disconnecting & taking out existing defective Industrial type socket of any description & in any Position and supplying and fixing new Industrial Type Socket 2 Pole+earths, 20 Amps, 240 volts complete all as specified and directed.
Disconnecting and taking out existing defective/ unserviceable complete industrial type socket with top in sheet metal box, of any description & in any position and Supplying and fixing new industrial type socket, 2 pole + earth 32 Amps, with and including plug top and MCB, 20 Amps, in sheet metal enclosure complete all as specified and directed.
Disconnecting and taking out existing defective / unserviceable timer of any description & in any position and supplying & fixing new timer assembly suitable for split AC of any capacity complete all as specified and directed.
Dismantling and taking out exiting defective service valve of any description & in any position and supplying and fixing new brass service valve complete all as specified and directed.
Disconnecting and taking out existing defective / unserviceable and Supply and fixing brass Nipple 15 mm dia for inlet and out let connection of water cooler any type / size including one PVC connection 15 mm dia with brass coupling on both ends complete all as specified and directed.
M&L for replacement of existing unserviceable/ damaged portion of the body of the water coolers i.e. in bottom/ top/ frame etc. with and including using new, 18 SWG, MS black sheet, cut to size, made to shape and size including necessary mouldings etc and fixing and riveting/ bolting with existing parts/ portion of the water coolercomplete all as specified and directed.
S&F in repair fan blade of any type and any description suitable for motor of any capacity for water cooler complete all as specified and directed.
S&F in repair condenser coil suitable for 165 to 230 ltr capacity refrigerator of any description and any model complete all as specified and directed.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and directed.
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed.
Labour only for minor repairing and attending the complaint of Split/ WindowAC/ Water cooler/ Refrigerator/ desret cooler/ voltage stabliser by highly skilled tradesman and Semi skilled and carry out minor repair and making functional complete all as specified and directed.
Taking out window type AC 1.5/2 ton and reinstallation including window opening cutting and provision of packing material as per site requirement including closing of old opening and making new opening all as specified and directed.
Taking out Split type AC 1.5/2 ton and relocation/ reinstallation as per site requirement including all connecting accessories i.e back plate nuts bolts etc. All as specfied and directed at site.(Note:- Copper piping will be measured and paid separately)
M&L for Servicing, checking of electric wiring, PCB Circuits, relayscontactor etc and replacement of defective wiring of Automatic Voltage Stablizer of 2/3/4/5KVA capacity of any make and carryout minor repair of PCB by changing resistance, condensor, transistor, indicator lamp, 2 way switch, PVC insulating sleeves etc and making functional complete all as specified and directed at site. Note :- Relays, transformer, ammeter, voltmeter , Kit kat fuse shall be measured and paid separately under relevant items
Supply only relay 24Volts, 20 A suitable for Automatic Voltage stablizer complete all as specified and directed.
Supply only kit kat fuse of 32A with carrier complete all as specified and directed.
Supply only analog voltmeter 0-500V of of any shape and size as per existing complete all as specified and directed.
Supply only relay 24 Volts, 20A heavy duty suitable for Automatic Voltage stablizer complete all as specified and directed.
Supply only auxilary transformer of 12/24Volt capacity suitable for PCB circuits of Stablizer complete all as specified and directed at site.
Supply only PCB for 2/5KVA stablizer complete all as specified and directed.
M&L for spray painting of voltage stabiliser of any make and capacity at different location of GE(E) Bly with one coat of super enameled synthetic paint of approved colour including scraping cleaning of old painted surfaces complete all as specified and directed.
S&F in replacement vertical pump/ submersible pump 2.80 mtr head complete all as specified and directed.
S&F in replacement side panel shutters made of GI sheet 24 SWG GI sheet suitable for any dimension desert cooler as per sample complete all as specified and directed.
S&F in replacement wood wool thick pad of size 34"x20' (set of three) suitable for desert cooler panel including GI chicken wire mesh of size 25 mm x 25 mm apperture ccomplete all as specified and directed.
S&F in replacement wood wool thick pad of size 21"x13' (set of three) suitable for desert cooler panel including GI chicken wire mesh of size 25 mm x 25 mm apperture complete all as specified and directed.
M&L for painting of desert cooler at site by disconnecting the electric connections and scraping old paint cleaning and preperation of surface by scrubbing and painting with one coat of anti corrosive paint internally and externally alongwith two coats of synthetic enamel paint externally on the surface of desert cooler complete all as specified and directed.
S&F in replacement 1400 rpm fan motor kit of size 500 mm sweep 180 watt single phase, AC 220/240 volts and making necessary connections complete all as specified and directed.
S&F in replacement of plug top 5 Amps to desert cooler complete all as specified and directed.
S&F in replacement of Plastic distribution (three way) of superior quality for desert cooler complete all as specified and directed.
S&F of fan blade made of iron for desert cooler complete all as specified and directed.
S&F of PVC fan blade for desert cooler complete all as specified and directed.
M&L in replacement of desert cooler tank made of GI sheet 26 gauge including fixing complete all as specified and directed.
S&F in repair float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark complete all as specified and directed.
S&F in repair PVC stop cock suitable for 15 mm dia GI pipe ISI mark complete all as specified and directed.
S&F in repair PVC connection 15 mm dia with CP nut 450 mm long ISI mark complete all as specified and directed.
M&L for Point wiring in repair of water cooler/refrigerator with 2.5 Sqmm copper conductor cables (multistranded) FRLS PVC insulated and unsheathed cable in and including concealed PVC conduit after chieseling the existing wall surface (ISI marked) 25mm dia with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet cover for one light point or one fan point controlled by one, one way switch including continuous 2.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dully complete all as specified conforming to IS-694 complete all as specified and directed.
All as per item No. 74 here in beforebut for Water cooler /deep freezer point using 4 Sqmm copper conductor cable (multi-strand) FRLS PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) FRLS PVC insulated and unsheathed earth wire complete all as specified and directed.
S&F in replacement switch socket combination 2 in 1, 3 pin 5/15A flush type universal complete all as specified and directed.
M&L in replacement for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through in PVC conduit complete all as specified and directed.
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ supply after taking out unserviceable compressor from deep freezer 300/310/400 Ltr capacity of any make including making necessary refrigerant pipe, elect connection, leakage testing complete all as specified and directed.
S&F hermetically sealed unit compressor (replaced with original company repaired) suitable for working on SP , 50 HZ supply after taking out unserviceable compressor from deep freezer 200 Ltr capacity of any make including making necessary refrigerant pipe, elect connection, leakage testing complete all as specified and directed.
S&F relay assembly complete suitable for 200 Ltrs deep freezer complete all as specified and directed.
S&F in repair relay assembly complete suitable for 300/ 310/400 Ltrs deep freezer complete all as specified and directed.
S&F in repair over load protector (OLP) for 200 Ltrs deep freezer all as specified and directed.
S&F in repair over load protector (OLP) for 300/310/400 Ltrs deep freezer complete all as specified and directed.
Supply only charging of R-134a refrigerant gas in deep freezer of capacity 200 Ltr or description to its saturation level complete all as specified and directed.
S&F in repair thermostat switch with knob complete all as specified and directed.
S&F in repair thermostat switch with knob for 300/310/400 Ltrs complete all as specified and directed.
S&F in repair Freezer assembly for 300/ 310 ltr deep freezer complete all as specified and directed.
S&F in replacement Freezer assembly complete with freezer door 200 Ltrs refrigerator complete all as specified and directed.
S&F in replacement to Inner panel assembly for 310 Ltrs capacity of deep freezer complete all as specified and directed.
S&F in replacement to Inner panel assembly for 200 Ltrs capacity of deep freezer complete all as specified and directed.
Dismantling and S&F Megnatic door gasket for 200 Ltrs of deep freezer complete all as specified and directed.
Dismantling and S&F Megnatic door gasket for 300/310/400 Ltrs deep freezer complete all as specified and directed.
M&L for scraping out old paint and preparation of surface of deep freezer of any capacity and two coats of spray painting of synthetic enamel paint of existing colour over a coat of red oxide primer on external surface and two coats of black synthetic enamel paint on compressor complete all as specified and directed
M&L for replacement of blower motor suitable for 300/310/400 ltrs capacity deep freezer complete including all necessary works and tanking out existing one complete all as specified and directed.
M&L for replacement of blower motor suitable for 200 ltrs capacity deep freezer complete including all necessary works and tanking out existing one complete all as specified and directed.
S&F in replacement Filter two way (as per sample) for deep freezer complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 56,705.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
R. S. Associates
prabhave traders
RAZA ENTERPRISES
SONI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .