Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.5 L+₹3.6 L (8.83%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹45.3 L+₹4.4 L (10.9%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹46.4 L+₹5.5 L (13.4%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹51.1 L+₹10.2 L (25.1%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L5 | Rejected-Finance Not being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Jul 2025, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Repair/ replacement and maintenance of Security/ Street Light, Aviation/ Watch Tower Flood Light, Post Top Lanterns of Zone A area and connected services under GE (I) Navy Jamnagar
2025_MES_712660_1
8854/VAL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹80,000
Yes
21 Jul 2025
5 Jun 2025
3 Jul 2025
5 Jun 2025
1 Jul 2025
19 Jun 2025
Amount
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed. Note: Reinforcement shall be measured and paid for separately.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L in repair for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS pipe shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
M&L for Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections & MS bars conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/ directed with & including one coat of red oxide zinc chrome primer, one under coat of aluminium paint and one finishing coat of aluminium paint, fixed in repairs, complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
Taking down street light / Flood light / Post Top fittings of any capacity from 8-200 W for repair/ replacement of burnt/ worn out accessories and refixing the same after all repair work complete all as directed. Notes :- (i) Spares shall be measured and paid for separately. (ii) The contractor shall check the fittings/ fixtures/ equipment/ wiring etc as per the complaints given by the concerned JE E/M / Engineer-in-charge. Spares required to be replaced shall be measured and paid for under respective items in this Schedule for which no extra payment on account of man power shall be paid. Contractor shall make arrangement for collection of complaint slip from MES service centre daily for carrying out the complaints & simultaneously intimate the JE E/M once the complaint is resolved. All complaints shall be resolved in 24 hours. (iii) In case contractor fails to resolve the complaint in 24 hours except where spare(s) is not readily available in the vicinity, a penalty of Rs. 100/- per day per complaint shall be deducted until the same is attended/ resolved. The decision of GE in this regard shall be final & binding.
Supply only LED driver of 8/9/10 W LED Bollard light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells/ existing make as approved by GE.
Supply only LED driver of 25/ 28 W LED Street light/ Post Top/ flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells/ existing make as approved by GE.
Supply only LED driver of 40/45 W LED Street light/ Post Top/ Flood Light fitting. Make: Osram/ Wipro/ Bajaj BGD 40 1050 5Y/ Jaquar ZDR-WHT-JQMSRT01S045/ Havells / existing make as approved by GE.
Supply only LED driver of 72 W LED Street light/ flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S072/ Havells / existing make as approved by GE.
Supply only LED driver of 90 W LED Street light/ flood light fitting. Make: Osram/ Wipro LG56-036-002-1540/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S090/ Havells / existing make as approved by GE.
Supply only LED driver of 120 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM120/ Havells / existing make as approved by GE.
Supply only LED driver of 150 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM150/ Havells/ existing make as approved by GE.
Supply only LED driver of 200 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells/ existing make as approved by GE.
Supply only LED driver of 400 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells/ existing make as approved by GE.
S&F in repairs 1.50 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through existing conduit pipe/ inside GI Pole from DB, Junction Box, etc to fitting with suitable lugs etc complete all as specified & as directed.
S&F in repairs Junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 Amp capacity including RYB and neutral with aluminium busbar, with & including MCB SP 6 Amp 10 kA 'C' Curve 240 V (01 No.) fixed to pole/wall with MS clamp made out of MS flat iron 25x5 mm with suitable nut, bolts, washers, etc and necessary painting to MS clamp with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified & as directed.
S&F in repair Cable looping box made from FRP sheet readymade of size 140mm x 140mm x 95mm, with PVC sheet finish inside with & including MCB SP 6 Amp 10 kA 'C' Curve, 240 V (01 No.), heavy duty connector for connection of 3 core cable and fixed to pole/wall with MS clamp made out of MS flat iron 25x5 mm with suitable nut, bolts, washers, etc and necessary painting to MS clamp with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified & as directed.
S&F in repair multi meter box made from SMC/ FRP sheet readymade of inside dimensions 530 x 450 x 175mm for fixing of kWH meter, weatherproof, shockproof, single piece moulded, single hinged door including connected item fixed to wall/ pole as per manufacturer’s instructions complete all as directed by Engineer-in-Charge. Make: Sintex Cat No. GSMB-5345 or equivalent in Hensel / ABB / Legrand / Schneider / Seimens as approved by GE.
S&F in repair multi meter box made from SMC/ FRP sheet readymade of inside dimensions 370 x 270 x 210mm for fixing of kWH meter, weatherproof, shockproof, single piece moulded, single hinged door including connected item fixed to wall/ pole as per manufacturer’s instructions complete all as directed by Engineer-in-Charge. Make: Sintex Cat No. GSMB-3727 or equivalent in Hensel / ABB / Legrand / Schneider / Seimens as approved by GE.
S&F in repairs MCB SP 6 Amp, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4085 87 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 80 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 83 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.
Taking down existing light fittings/ fixtures of any description and S&F new 90 Watt decorative Post Top Mount LED luminaire, high efficiency, IP-66 protection, luminaire efficacy 120 lm/W, CCT – 5700K (5665K ± 355K), Power Factor ≥ 0.95, THD < 10%, Surge Protection 10 kV, CRI > 70, powder coated spun aluminium housing with casted aluminium heat sink and clear optics polycarbonate/ toughened glass, the minimum lumen output of the system shall be 11700 lumens with lumens per watt 120±10%, asymmetric fixing to existing bracket including nut, bolts, and making necessary electrical connection with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable to the existing system and testing on completion complete all as directed. Make : Bajaj “BOR NX 90 W 57K D1 C3 GG S TM” or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fittings/ fixtures of any description and S&F new 45 Watt decorative Post Top Mount LED luminaire, high efficiency, IP-66 protection, luminaire efficacy 120 lm/W, CCT – 5700K (5665K ± 355K), Power Factor ≥ 0.95, THD < 10%, Surge Protection 10 kV, CRI > 70, powder coated spun aluminium housing with casted aluminium heat sink and clear optics polycarbonate/ toughened glass, the minimum lumen output of the system shall be 5850 lumens with lumens per watt 120±10%, asymmetric fixing to existing bracket including nut, bolts, and making necessary electrical connection with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable to the existing system and testing on completion complete all as directed. Make : Bajaj “BOR NX 45 W 57K D0 C3 GG S TM” or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fittings/ fixtures of any description and S&F new 45 Watt decorative Post Top Mount LED luminaire, high efficiency, IP-66 protection, luminaire efficacy 120 lm/W, CCT – 5700K (5665K ± 355K), Power Factor ≥ 0.95, THD < 10%, Surge Protection 10 kV, CRI > 70, powder coated spun aluminium housing and clear optics polycarbonate/ toughened glass, the minimum lumen output of the system shall be 5400 lumens with lumens per watt 120±10%, asymmetric fixing to existing bracket including nut, bolts, and making necessary electrical connection with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable to the existing system and testing on completion complete all as directed. Make : Bajaj “BOR NX 45 W 57K D0 C3 GG S PT” or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 150 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed.
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 200 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed.
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 400 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed.
Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 45W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing post top lantern of any description and S&F new 25W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 25W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing Ring Post top light fitting and S&F new 60 Watt LED Ring Post Top lighting fixture, IP-65 protection, outdoor type, decorative, energy saving, environmental friendly, long life aesthetically designed with powder coated Die cast aluminium housing, Polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, complete all as directed. Make : Surya Cat No. RIGEL SLE PT 60 W / Jaquar Cat No. LGTP07X060XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any type & fixed in any position and S&F new 9/12 Watt LED surface mounted UP SPIKE/ BUSH light fixture, with die cast aluminium housing transparent tempered glass diffuser, minimum IP 65 protection, minimum CCT 3000K, fixed in any position over surface by spikes properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed. Make: Bajaj Cat No. BGSBL 9W LED WW or Jaquar Cat No. LSPK05R112XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any type & fixed in any position and S&F new 2 x 6 Watt LED wall mounted UP and DOWN clear/ warm white decorative LED light fixture with die cast aluminium housing transparent tempered glass diffuser, minimum IP 54 protection, minimum CCT 2700K, fixed in any position on wall with Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed. Make : Wipro Cat No. GARNET DW11227, Jaquar Cat No. LWWL02R206XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing bollard light fitting and S&F new 9/10 W LED Bollard light fitting IP-54 rated with inbuilt LED, made in die cast aluminium housing Frosted polycarbonate diffuser, CCT 3000K complete with all standard accessories fixed as per manufacturer's instructions and making necessary electrical connections including testing on completion complete all as directed. Make: Bajaj Cat No. BGBOM 605 9W LED or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing landscape projector light fitting of any description and S&F new 25 Watt outdoor aesthetic LED light fixture, IP 66 protection, Lumen Efficacy ≥ 140 lm/W, powder coated, pressure die cast aluminium housing, toughened clear glass cover, Power factor ≥ 0.95, THD ≤ 10, CCT 3000K, fixed as per manufacturer’s instructions and making necessary electrical connections and testing on completion, complete all as directed. Make: Havells Cat No. LYCUSSPS25WLED830PSYMBOTG or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing search lights fittings/ fixtures of any type and Supply, intallation, commissioning and testing new 300 W high intensity LED revolving search light, Energy saving, long range, beam range 700 Mtrs, IP66, high lumen LED>140 lm/W, PF > 0.95, CCT : 5000K -6000K, CRI > 70, optical grade PMMA/ PC lens reflector, efficiency > 95%. multiple circuit to avoid complete run down, narrow beam upto 5 degree, die cast LM6 body with air fins, powder coated, constant current, average lux (in 1 metre circle) at 10 metre away 2500 to 6000, working volt 120 V - 300 V, working temp - 20°C to +60°C, meets the standard of LM79, LM80, IS:10322 fixed on & including Motorised revolving stand, auto swiveling, suitable for mounting of search light on roof-top & such design to rotate 360° continuously in 3 rmp over the night. The revolving mechanism is fully covered with weather & rust proof fiber box with maintenance door, foundation holes (4 Nos) at bottom and wall mounted control panel including speed controller (1-10 rpm) wth Rev./ Forw. buttons. & power tilting upto 45° fixed as per manufacturer's insructions and as directed. Make: Kalin Engineering Works, Kanpur Model No. MRSL-LRFLL25-PC301 or equivalent in SIGMA, Kolkata or in make approved by GE. Note: (i) Warranty for two years, which including 1 year defect liability period, as per prescribed format shall be submitted. (ii) Whole assembly shall be of Indigenous i.e Indian origin and China makes shall not be accepted under any circumstances.
S&F in repairs Aviation obstruction Red LED light 8.5 watt, 230 volts, IP 65, 50 Hz, fixing on top of the OHT/ Watch tower of height upto 25 mtr including necessary electrical connection and foundation complete all as specified & as directed. Note : Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of aviation light on top of OHT/ Watch tower and quoted rate shall deemed to be included of this aspect.
S&F in repair High Pressure Sodium Vapour (HPSV) Lamp of 1000 Watt, 240 Volt, 50 Hz fixed in light fitting on top of Watch tower i.e. height of 15 mtr with all necessary electrical connection complete all as specified and as directed. Note : Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of HPSV lamp on top of Watch tower and quoted rate shall deemed to be included of this aspect.
Dismantling the existing street light PCC pole and fittings, bracket along with junction box, any size of cables complete all as directed by Engineer-in-Charge.
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, 'C' Curve (1 No.), MCB TP 32 Amp, 415 V, 10 kA, 'C' Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 3 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 16 mm dia, pitch circle dia 200 mm, bolt length 450 mm, projected bolt length 80 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 A, 240 V, 10 kA, 'C' Curve (1 No.), Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-3030 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.
S&F in repair Power Contactor, 3 Pole, AC1 rating - 45 Amp, including necessary connections for incoming and outgoing complete all as specified & as directed. Make : L&T Type ML3 Cat No. SS90721 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Astro digital time switch, 1 Out put 16 A, 1 channel mounting in existing panel, suitable for switching ON/OFF light and other electric devices according to the rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/or fixed preset times and also suitable for daily astronomical calculation of the sunrise/sunset time based on the entered location or location coordinate complete all as directed. Make: Legrand Cat No. 4126 54 or equivalent in makes mentioned in Appendix 'B' here-in-after.
M&L for preparing surfaces of PCC pole by cleaning, removing creeper etc and painting with two coats of antifungal exterior emulsion weather proof paint of approved colour shade and writing Pole numbers with white paint having black background enamel paint suitable for outdoor including painting GI/ MS bracket & clamps of street light fitting fixed on pole with two coats of synthentic enamel paint over one coat of red oxide primer complete all as directed.
M&L for preparing steel/ GI/ Metal pole (upto 6 mtrs height) surface by cleaning, removing creeper etc including GI/ MS bracket & clamps of street light fitting fixed on pole and painting with two coats of Aluminium paint over one coat of zinc chromate primer and writing Pole numbers with white paint having black background enamel paint suitable for outdoor complete all as directed.
M&L for preparing steel/ GI/ Metal pole (upto 5 mtrs height) surface by cleaning, removing creeper etc including fancy type GI/ MS bracket & clamps of street light fitting fixed on pole and painting with two coats of synthetic enamel paint (Golden & Black colour or as directed) over one coat of zinc chromate primer and writing Pole numbers with white paint having black background enamel paint complete all as directed.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 6 sqmm 2 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for cutting of existing PCC floor / hardstanding / Interlocking tiles path / WBM road with soling & premix carpet of any description for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed including re-setting of interlocking tiles/ Paver block (where required) complete all as directed.
Supply and laying of instant ready mix premixed bituminous material for repairing road cutting, depression on pot holes etc, material consisting of modified all-weather bitumen paste in liquid asphalt with chemicals, anti-stripping agents, graded aggregates & additives / granular material 5-20mm crushed stone aggregate with 5.5% of bitumen, in 25 Kg bag, laid as per manufacturer’s instructions including preparation of surfaces, complete all as specified & as directed. Make: ‘ShaliPatch’ of STP Ltd or equivalent as approved by GE. Note : The unit of measurement and payment purpose is ‘Per Bag’ of 25 Kg ready mix material.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
JAYESH TRADING CORPORATION (BID ID -3332636)
1R K Traders (BID ID -3332502)
JAMNAGAR ELECTRIC AND MACHINERY CO (BID ID -3334812)
fakhrie apostrical (BID ID -3334735)
M/s Balaji Enterprise (BID ID -3333271)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .