Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.5 LAccepted-AOC | 1 | Accepted-AOC l1 | |
| 2 | 2₹8.6 L+₹9,484.27 (1.12%)Rejected-AOC | 2 | Rejected-AOC l2 | |
| 3 | Rejected-Technical KIDARAKUZHI PUTHUVAL PUTHEN VEEDU VENKADAMBU UCHAKKADA P O THIRUVANANTHAPURAM 695506 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695506 | - | Rejected-Technical 3RD |
Tender Value
Refer Docs
EMD Value
₹13,389
Closing Date
15 Feb 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER
LSGD SECTION ,KARUNAPURAM
CONSTRUCTION OF KRISHNAPURAM ANGANWADY (ANGANWADY NO.82)
2021_LSGD_412525_1
12/2021/AE/LSGD/KPM
Open Tender
Civil Works - Buildings
Item Rate
30 days
KARUNAPURAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,018
Yes
₹13,389
Yes
10 Dec 2021
6 Feb 2021
17 Feb 2021
6 Feb 2021
15 Feb 2021
6 Feb 2021
30 days
Amount
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
60.7.8 : DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
od1072239/2020_2021 : Supplying precast factory moulded RCC DOOR frame of size 90x210 cm or nearest size and fixing in position in line and level directed by the engineer in charge including fixing MS clamp 3 nos with minimum length of 25 cms on each vertical side of the frame with necessary screws and fixing the clamp with concrete in wall using 1:2:4 (one cement :2 fine sand :4 coarse aggregate 20 mm) concrete mix including all cost of conveyance, material cost, labour charges, curing charges etc complete.(concrete for fixing the clamp shall be paid separately)
od1078585/2020_2021 : Supplying precast factory moulded RCC WINDOW frame of size 150 x100 cm or nearest size and fixing in position in line and level directed by the engineer in charge including fixing MS clamp 3 nos with minimum length of 25 cms on each vertical side of the frame with necessary screws and fixing the clamp with concrete in wall using 1:2:4 (one cement :2 fine sand :4 coarse aggregate 20 mm) concrete mix including all cost of conveyance, material cost, labour charges, curing charges etc complete.(concrete for fixing the clamp shall be paid separately)
od1078592/2020_2021 : Supplying precast factory moulded RCC WINDOW frame of size 150 x150 cm or nearest size and fixing in position in line and level directed by the engineer in charge including fixing MS clamp 3 nos with minimum length of 25 cms on each vertical side of the frame with necessary screws and fixing the clamp with concrete in wall using 1:2:4 (one cement :2 fine sand :4 coarse aggregate 20 mm) concrete mix including all cost of conveyance, material cost, labour charges, curing charges etc complete.(concrete for fixing the clamp shall be paid separately)
od1072241/2020_2021 : Supplying and fixing ventilatar
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
jitto
Aneesh
Bidder Name
jitto
Aneesh
Jose Prince
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_586088.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .