Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹3.2 Cr+₹35.8 L (12.4%)Rejected-AOC 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹3.2 Cr+₹35.8 L (12.4%) | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹3.5 Cr+₹62.3 L (21.7%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹3.5 Cr+₹62.3 L (21.7%) | L3 | Rejected-AOC Other than lowest bidder |
| 4 | L4₹3.6 Cr+₹67.7 L (23.5%)Rejected-AOC 19192 STREET NO 8 BIBI WALA ROAD OPPOSITE DAV COLLEGE BATHINDA PUNJAB PIN 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹3.6 Cr+₹67.7 L (23.5%) | L4 | Rejected-AOC Other than lowest bidder |
| 5 | L5₹3.8 Cr+₹87.7 L (30.5%)Rejected-AOC C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹3.8 Cr+₹87.7 L (30.5%) | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹3.6 Cr
EMD Value
₹4.4 L
Closing Date
3 Dec 2024, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CE CHZ CHM T 12 2024 25 ADDN ALTN TO MD ACCN AT SECTOR 28 AND 29D CHANDIGARH UNDER GE CHANDIGARH
2024_MES_673644_1
CE CHZ/CHM/T-12/2024-25
Open Tender
Civil Works
Works
365 days
CHANDIGARH
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹2,000
GE Chandigarh
₹4.4 L
Yes
23 Jan 2025
11 Sept 2024
5 Dec 2024
11 Sept 2024
3 Dec 2024
5 Nov 2024
11 Sept 2024 - 6 Oct 2024
Amount
B/R Work
Taking down chowkhats/frames with shutters not exc 1.5 Sqm (without taking off shutters from the frames) and removing from the site complete, all as specified and directed by Engineer-in -charge.
Taking down chowkhats/frames with shutters area exc 1.5 Sqm but not exc 4 Sqm (without taking off shutters from the frames) and removing from the site complete, all as specified and directed by Engineer-in -charge.
Taking down shutters of any description not exc 1 Sqm each and removing from the site complete, all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each including stacking at directed location for refixing and/or removing to store or site complete ,all as specified and directed by Engineer-in -charge.
Demolition of brick work built in cement mortar including all quoins arches pillars removing rubbish outside MoD land complete ,all as specified and directed by Engineer-in -charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Demolition of reinforced cement concrete in any position at any height (reinforcement cut as required to facilitate demolition) and removing rubbish out of MoD land complete, all as specified and directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Demolition of reinforced cement concrete in floors ,beams ,chajjas,landing slab in any position or height and similar suspended works and removing rubbish out of MOD Land complete, all as specified and directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Demolition of lime/ cement concrete in ground floors and pavings exc 15 cm thickness (below or above ground level) including chaina mozaic,WC etc. and removing rubish out MOD land complete, all as specified and directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15 cm thick (below or above GL) and removing rubbish outside MoD land complete, all as specified and as directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises of MOD land complete ,all as specified and directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc of any description or thickness, laid, bedded and pointed in any mortar complete and removing rubbish out of MoD land complete, all as specified and directed by Engineer-in-Charge. Note - Debris will be disposed as per UT Norms and Contractors will laise to UT officials and rates quoted shall deemed to include this aspect.
Supply and fixing factory made pressed steel frames having profile 125mm x 60mm for doors with one or more rebates made out of 1.25 mm thick MS sheet, including necessary fixing lugs, 04 Nos medium weight 100mm size hinges, lock strike plate, thresh hold bar/flat etc. and one shop coat of primer complete, all as specified and directed by Engineer-in -charge.
Supply and fixing factory made pressed steel frames of size 105 x 60mm for doors with one/more rebates including necessary fittings, lugs, 04 Nos medium weight 100mm size hinges, lock strike plate and one shop coat of primer complete ,all as specified and directed by Engineer-in -charge.
Supply and fixing factory made 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side complete, all as specified and directed by Engineer-in -charge.
Supply and fixing factory made 30 mm thick second class hard wood glazed and skelton shutters open rebated and prepared to received glass gauge etc,( without sash bars), edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass, etc. supplied and fitted to chowkats complete ,all as specified and directed by Engineer-in -charge. Dimensions of shutters shall be as specified in SSR part I (2009), Section-8, Clause 8.24(a).
Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed Stainless Steel screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/Stainless Steel dash 100mm/125mm long fasteners of required dia complete all as per drawings and as per direction of Engineer-in-Charge.
Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary fill body threaded starheaded countersunk SS screws , complete all as per drawings and as specified and directed by Engineer-in -charge.
Material & Labour 2 nd class hard wood Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete ,all as per the direction of Engineer-In- Charge.
Supply and fixing of factory made 25 mm thick single extruded WPC (Wood Polymer Composite) solid Plain board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC Beading on exposed surface all as per drawings and direction of Engineer-In- Charge. Note : Material test certificate& authentication should be provided by the manufacturing company.
Supply and fixing of factory made 25 mm thick single extruded WPC (Wood Polymer Composite) solid single side PVC Laminate with PVC foil of minimum 14 Microns thick of approved colour shade Board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC Beading on exposed surface ,complete all as per drawings and direction of Engineer-In- Charge. Note : Material test certificate& authentication should be provided by the manufacturing company.
Supply and fixing of factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid Plain board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC beading on exposed surface complete , all as per drawings and direction of Engineer-In- Charge. Note : Material test certificate& authentication should be provided by the manufacturing company.
Supply and fixing of factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid single side PVC Laminate with PVC foil of minimum 14 Microns thick of approved colour shade Board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC Beading on exposed surface complete,all as per drawings and direction of Engineer-In- Charge. Note : Material test certificate& authentication should be provided by the manufacturing company.
Supply and fixing Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, as in back side of kitchen cabinet with pvc leeping pasted at exposed sides sag free thermal and electrically insulated, light weight wrap free, impact resistant, fire resistant, termite resistant, chemically resistant and smell free complete ,all as specified and directed by Engr-in-charge.
Material & Labour plain cement concrete (1:3:6 ) type B-0 using 12.5mm graded stone aggregate, as in back filling of chowkhats, as in coping, bed plates including necessary form work and weathering, slightly rounded or chamfered angles and throating complete, all as specified and as directed by Engr-in-charge.
Material & Labour for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in blocks for fixing hold fasts & pressed steel frames for doors including necessary form work complete, all as specified and as directed by Engr-in-charge.
Supply and fixing Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm fixed with tinned tack or stainless wire stapples complete, all as specified and as directed by Engr-in-charge.
Supply and fixing as in repair of Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with Stainless Steel wire staples complete, all as specified and as directed by Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden ,iron frames ,glazed with putty or fixed with beads including punching or drilling out glazing pins/spring clips complete, all as specified and as directed by Engr-in-charge.
Supply and fixing 4 mm thick plain float glass, ordinary quality and glazing with silicon sealant in squares not exc 0.5 Sqm in each pane complete, all as specified and as directed by Engr-in-charge.
Supply and fixing 4.8 mm thick sheet float ordinary quality and glazing with silicon sealant in squares exc 0.5 Sqm in each pane complete, all as specified and as directed by Engr-in-charge.
Supply and fixing 4 mm thick figured glass pin head type and glazing with silicon sealant in square not exc 0.5 sqm in each pane complete ,all as specified and as directed by Engr-in-charge.
Supply and fixing of stainless steel butt hinges 100 mm long medium weight with stainless steel screws complete ,all as specified and as directed by Engr-in-charge.
Supply and fixing 300 mm MS ordinary rat tail rod pattern springs including roller and roller plate fixed to wooden chowkhats or welded to angle iron door frames complete, all as specified and as directed by Engr-in-charge.
Supply and fixing aluminium anodised extruded fabricated type handle 150 mm long complete, all as specified and as directed by Engr-in-charge.
Supply and fixing 150 mm long Aluminium anodised barrel tower bolts of extruded section complete ,all as specified and as directed by Engr-in-charge.
Supply and fixing Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing with bolts extruded sections complete, all as specified and as directed by Engr-in-charge.
Ditto- as in above item No 37 but fixed in repairs.
Material & Labour 140 mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete, all as specified and as directed by the Engineer-in-Charge.
Ditto- as in above item No 39 but fixed in repairs.
Supply and fixing in repair 30 mm Continuous (piano) hinges, stainless steel, bright finish or electrogalvanised including star head screws complete, all as specified and as directed by Engr-in-charge.
Supply and fixing of stainless steel finish zinc chrome handles, curve design, 144 mm size for kitchen cabinet and shutters complete ,all as specified and as directed by Engr-in-charge.
Supply and fixing for chrome plated food grade stainless steel wire in any baskets of a moduler kitchen (storage basket, cup and saucer basket, jas basket, thali basket, cutlery basket, grain trolley, plain basket, bottle pull out etc), min loading capacity 65 KG, made by min 6 mm dia stainless steel round bars, proper welded and joints finish by grinding, chromium plated finish, fixed properly with WPC board of any thickness as per design approved, including fixing of auto closing hinges, ball bearing runners of any description, stainless steel handles fixing clips, sliding frame structure, Stainless steel screw etc complete ,all as specified and directed by Engineer-in-charge. Note : 1. Weight of fitting/fixtures like handles, hinges, ball bearing runners, telescopic channels etc will not be measured. 2. Only weight of Stainless steel wire basket will be measured before fixing. 3. Only Fixing of all Fitting/fixtures like handles, hinges, ball bearing runners, telescopic channels etc are included in this item supply of the same will be paid in saperate items as supply only.
Cutting grooves in brick wall,75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete, all as specified and as directed by Engr-in-charge.
Supply only of Auto closing hinges of size 35mm of 0 crank (KH–001) of 8 crank (KH–002) openable at 0 degree for kitchen cabinet shutters complete, in all as specified and directed by Engr–in–Charge.
Supply and fixing magnetic catcher cum silencer Chromium plated and fixed with standard steel screws, complete ,all as specified and as directed by Engr-in-charge.
Supply only of Ball bearing runners 45 mm Telescopic Channel ( 20 Inch ) full extension load capacity 50 kgs, Black powder coated complete ,all as specified and directed by Engr–in–Charge.
Material & Labour mild steel work in framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165
Material & Labour for applying two coats of synthetic enamel paint over and including a coat of pink primer on new or previously untreated wooden surfaces exc 10cm girth or girth incl preparation of new wooden surfaces complete ,all as specified and as directed by Engr-in-charge.
Material & Labour preparation of new steel surface or iron surface of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including a coat of red oxide primer complete ,all as specified and directed by Engineer-in -charge.
Material & Labour for applying two coats of synthetic enamel paint on steel or iron surfaces exc 10cm girth or girth incl preparation of new steel surfacescomplete, all as specified and directed by Engineer-in -charge.
Material & Labour preparing old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete ,all as specified and directed by Engineer-in -charge.
Material & Labour for applying two coats of synthetic enamel paint on new or previouly untreated wooden surface exc 10cm girth or girth including preparation of new wooden/WPC surfaces complete all as specified and directed by Engineer-in -charge.
Material & Labour for preparation of old painted steel and iron surfaces by brooming or by steel wire brushing, scrapping down snow soot,moulds, moss and efflorescent salts and treading oil and greasy spots, of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint( ist quality ) complete, all as specified and directed by Engineer-in -charge.
Material & Labour Brick work using old size bricks (Designation-100), straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6) complete ,all as specified and as directed by Engr-in-charge.
Material & Labour for Brick work (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6) complete, all as specified and as directed by Engr-in-charge.
Material & Labour for Brickwork with sub class 'B' bricks(Designation-100),straight or curved on plan to any radius in half brick thick walls in cement mortar 1:4 complete, all as specified and as directed by Engr-in-charge.
Taking down Cement plaster or cement lime plaster on brick or stone walls and ceiling etc. including raking out joints hacking for key & scrubbing down with water etc complete, all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfacses, finished the surface fair & even without using extra cement complete ,all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, with surface finish fair & even without using extra cement complete, all as specified and as directed by Engr-in-charge.
Material & Labour for rendering 5mm thick in cement mortar 1: 3 on soffit of roof ceiling/chajja, finished even & smooth without using extra cement complete, all as specified and directed by Engineer-in-Charge.
Material & Labour for three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete, all as specified and directed by Engineer-in -charge.
Material & Labour for Putty of average thickness 1 mm over the plastered @ 1kg per sq. mtr. after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust by skilled abour. Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty and for one coat of waterproofing primer and damp-proof primer @ 1 Itr per 100 sq. undiluted to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats.,and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface complete all as specified and directed. Note :- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Oil bound distemper, putty etc after approval by the GE. (b) The Contractor shall produce"Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected.
(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary. (e) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (f) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (g) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (h) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the efficieny of the Oil bound distemper for 3 yrs during the guarantee period.
Material & Labour for one coat of waterproofing primer and damp-proof primer @ 1 Itr per 60 sq. diluted with 10% by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, After priming two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp. by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 64 sait diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed and specified by Engineer-in-Charge. Note :- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall produce"Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.
(e) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (f) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (g) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (h) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the efficieny of the weather proof paint for 5 yrs during the guarantee period.
Material & Labour for Preparing old plastered surfaces of ceiling and applying two coat of white wash complete ,all as specified and as directed by Engr-in-charge.
Removal of existing treatment with wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy spots filling holes, cracks with putty and applying three coat of white wash complete ,all as specified and as directed by Engr-in-charge.
Dismantling of mild steel work of any description and in any position complete, all as specified and as directed by Engineer-in -charge.
Supply and fixing MS flat iron as in Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required,hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamp;hold fasts; wall ties; hooks for hanging fans; conforming to Fe-290 (Grade-165). complete, all as specified and as directed by Engineer-in -charge.
Supply & Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x 100 mm mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed Stainless steel screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/Stainless steel dash 100mm/125mm long fasteners of required dia complete ,as per direction of Engineer-in-Charge.
Supply & Fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter complete,all as specified and directed per direction of Engineer-In- Charge.
Supply and fixing MS rolled sections as in roof trusses (framed), trussed,purlins, rails and fastenings and bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. similar work conforming to Fe-410-W(Gde-E-250) quality B complete, all as specified and as directed by Engineer-in -charge.
Supply and fixing Steel tubular section of any size and shape including special shaped washer fixing in any position etc.complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete, all as specified and as directed by Engineer-in -charge.
Supply and fixing 20mm Wire mesh netting of galvanised steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete, all as specified and as directed by Engineer-in -charge.
Material & Labour 2 mm thick Fibre glass reinforced translucent plain sheeting fixed with coach screw and washer in roof, wall etc complete ,all as specified and directed by Engineer-in-Charge.
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exc 10 cm long with dia of shank 11 to 15 mm etc complete, all as specified and as directed by Engineer-in -charge.
Material & Labour for nominal mix 1:1.5:3 (using 20mm graded crushed stone agg.) as in RCC slab supported on walls, beams etc and shelves Complete ,all as specified and directed.
Material & Labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete, all as specified and directed by Engr-in-Charge.
Ditto- as item No 77 above but 5 to 10 mm dia as in stirrups,Spacer complete, all as specified and directed by Engr-in-Charge.
Material & Labour form work to edges of concrete flats, not exc 20 cm wide horizontal or sloping and similar works exc 10 cm but not exc 20 cm wide complete ,all as specified and directed by Engr-in-Charge.
Use & waste of form work for rough finished surface to soffit of suspended slabs such as roof slabs, floor slabs, landing, chajja and similar work n.exc 200mm thick (horizontal or sloping) complete, all as specified and directed by Engineer-in-Charge.
Repairing the edges of concrete chajjas, facias, slabs, columns & the like by providing PCC (1:2:4) type B-0 including all necessary form work and/or provision of rendering 15 mm thick (average thickness) in cement mortar (1:3), after applying a coat of cement slurry @ 3 kg/ Sq. m of surface, finished even and fair, surface area not exceeding 450 mm wide, in patches including taking down swoolen/damaged plaster or concrete complete, all as specified by Engineer-in-Charge.
Disconnecting existing tanks exc 250 ltr and not exc 500 ltr, setting aside (or lowering if required) for repairs,cleaning etc and hoisting as required reconnecting and re-fixing in position (cleaning and repairing etc shall be measured separately) complete ,all as specified by Engineer-in-Charge..
-Ditto- All as per Ser item No 82 but exc 500 ltr and not exc 1000 ltr.
Cleaning and removing with bleaching powder to all scale, sludge, mud, algae and dirt etc from tanks capacity upto and including 500 litres and from mouths of circulating pipes etc and washing with clean water including writing in words with synthetic enamel paint as CLEANED ON (date) complete, all as directed by Engr-in-Charge.
-Ditto- All as per Ser item No 84 here-in-before but capacity exc 500 litres and not exc 1000 Ltrs.
Taking down GI tubing and connection including removing to store of 15 mm dia complete ,all as specified and directed by Engineer-in-Charge.
Ditto.-All as per item No 86 above but 20 mm dia.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including plain and brass fittings complete, all as specified and directed by Engineer-in-Charge.
Ditto.-All as per item No 88 above but 25 mm dia.
Supply and fixing 25mm dia CPVC brass Tank Adaptor complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing 25mm dia CPVC brass Union complete, all as specified and directed by Engineer-in-Charge.
Dismantling of existing water tanks exc 250ltr & not exc 500 ltr complete, all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 92 but exc 500ltr & not exc 1000 ltr.
Supply and fixing rotational moulded water storage tank (cylinderical vertical with closed top ) triple layered hoisted and fixed in position capacity 500 ltrs with 20mm dia PTMT float valve complete ,all as specified and directed by Engineer-in-Charge.
-Ditto- all as per Item No 94 above but capacity 1000 ltrs with 20mm PTMT float valve.
Cutting chases through brick walls girth exc. 10cm pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps , cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing complete ,all as specified and directed by Engineer-in-Charge.
Brushing neat cement slurry with 3.0 kg of cement per square metre complete, all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick in CM 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete/brick surfaces finished even and smooth without using extra cement complete, all as specified and as directed Engineer-in-charge.(WPC shall be measured & paid for separately)
Supply only liquid water proofing compound ISI marked complete, all as specified by Engineer-in-Charge.
Dismantling of Brick tiles or terracing tiles, single layer on roofs etc complete all as specified and directed complete ,all as specified and directed by Engineer-in-Charge.
Demolition of Mud in roof,any thickness,including plastering and leeping(whether full thickness removed or only a part there of) complete, all as specified and directed by Engineer-in-Charge.
Removing excavated material out of MoD land complete, all as specified and directed by Engineer-in-Charge. Note :- Debris will be disposed as per UT norms and contractor will laise with UT and rates quoted shall deemed to include this aspect .
Material and labour nominal mix cement concrete M15 in Padding roof rough finish complete, all as specified and directed by Engineer-in-Charge.
Material and labour for Providing cement concrete B0 1:2:4 (12.5mm gaded aggegate) in roof kerbs or roof kerbs mud stops, rounded or chamfered on edges complete ,all as specified and directed by Engineer-in-Charge.
Material and labour for providing and laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) on over and including primed surface by torched application . The APP membrane shall be laid using torch-on application with minimum 10 cm side overlap and 15 cm end overlap. The APP membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet complete ,all as specified by Engineer-in-Charge.
Material & Labour for Plain cement concrete 1:5:10 (using 40mm graded brick aggregate) as in sunken filling and mass concrete complete ,all as specified and directed by Engineer-in -charge.
M&L for 20mm thick grey coloured PCC tiles 25cm x 25cm, machine pressed laid over & including 20mm thick screed or bedding layer in cement mortar 1:4 mixed with and including waterproofing compound and joints grouted & pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete ,all as specified and directed by Engineer-in -charge.
Material & Labour of water proofing of the sunken portion using a flexible two part acrylic polymer modified cementious liquid applying water proofing coating which include the substrate preparation by mechanical mean in order to clean the area from dust/loose particle., contamination etc. Repairing surface irregularties damaged concrete surface crack , bugs holes or potholes in base slab. if any , with an acryclic polymer .These substrate shall then be primed using high pressure water jet or other method, properly prewetted to SSD condition before coating. post substrate repair a primer coat shall be laid using a synthetic rubber emulsion based cememtious coating system, using brush or roller.once primer as applied , two coat of flexible two part acrylic polymer modified cememtious liquid appiled water proofing coating shall be made including fibre mesh with a consumption rate 2kg/sqm for two coats , which must meet the technical specification as under:- - Tensile strength > 1.5mm N/mm2 as per ASTM D412-92 . Elongation of break> 105% as per astm d412-92. Hardness shore A> 40ASTM D2240:91
Supply and fixing 32mm bore Galvanised steel tubes, light grade , for sprout with end cut to 45 degrees complete, all as specified and directed by Engineer-in -charge.
Roughening of old surfaces of old concrete floor by picking , sweeping,clean and washing down with water to remove dust etc complete,all as directed and specified by Engineer-in-Charge.
Material & Labour for Plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) 25mm thick sub base of floor as in level course complete, all as specified and as directed by Engineer-in-Charge.
Material & Labour for light shade vitrified Ceramic tiles (double charged) 8 to 10 mm thick (square/ rectagular) polished,area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm , in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 as specified and directed by Engineer-in-Charge.
Material & Labour for coloured non-skid Ceramic tiles min 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (Premium quality), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete, all as specified and directed by Engineer-in-Charge.
Ditto- but as per item No 113 but in skirting over and including rendering 10 mm thick on brickwork or concrete surfaces finished even and fair in CM 1:4.combinations complete, all as specified and directed by Engineer-in-Charge.
Material & Labour for Non skid, Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but not exc 0.18sqm laid as in floors/skirting, set and jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with coloured cement to match with surfaces of tiles complete, all as specified and directed by Engineer-in-Charge.
Material & Labour Glazed ceramic coloured tiles in vertical surface 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match . The tiles shall be laid in pattern with two or more colured tile including rendering 10 mm thick on brickwork or concrete surfaces finished even and fair in CM 1:4.complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of bib taps cast copper alloy fancy type ,chromium plated, 15mm bore with crutch/butterfly handle screwed for iron pipe complete ,all as specified and directed by Engineer-in -charge.
Supply and fixing in repairs vitreous china wash down water closet pan (Pedestal pattern) with seat cover white (exluding fixing bolts, flushing cistern and flush pipe complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Vitreous china squatting pan 'orrisa' pattern size 580 x 440 mm white integral floor rests ( excluding flushing cistern ) including connection to trap and to flushing pipe anti syphonage pipe etc complete including making good to floor, complete, all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair spray jet chromium plated including suitable length of PVC connection pipe complete, all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair PVC (SWR) 'P' or 'S' trap, ISI marked, suitable for 110 mm bore complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair vitreous china wash basin,white,size 550x400mm,including CI brackets and cutting for and pinning in ends of brackets or erecting stands etc complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Bib taps, cast copper alloy with handle, chromium plated fancy type, long body with wall flange screwed down, suitable for 15 mm bore pipe complete, all as specified and directed by Engr–in–Charge.
Supply and fixing in repair Concealed stop valve, cast copper alloy, screwed down, high pressure with handle, chromium plated, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe complete, all as specified and directed by Engr–in–Charge.
Supply and fixing of stop valves/angle valve, fancy type, chromium plated 15mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete, all as specified and directed by Engr–in–Charge.
Supply and fixing in repair Waste coupling of CP, for WHB any colour half or full threaded suitable for 32 mm size discharge pipe (Minimum weight 45 gm) complete ,all as specified and directed by Engr–in–Charge.
Supply and fixing flexible PVC pipes suitable for waste pipe in wash basins, sinks and urinals for 32 mm dia waste coupling complete, all as specified and directed by Engr–in–Charge.
Supply and fixing in repairs chromium plated overhead shower of size 200x200mm (Square) with CP shower arm 600mm long with flange, with swivel joints, fixed to 15mm bore CPVC pipe complete ,all as specified and directed by Engr–in–Charge.
Supply and fixing in repair health faucet ABS body with 1 metre long easy flex PVC tube in chrome finish and wall hook Complete, all as specified and directed by Engr–in–Charge.
Supply & Fixing in repairs PVC flushing cistern 10 litres capacity syphonic action type, low level, white with inlet, ball valve, float, handle and flush pipe, etc complete ,all as specified and directed by Engineer-in -charge..
Supply and fixing PTMT bathroom mirror cabinet of size of 400 mm x 500mm fixed stainless steel screws with pvc rawl plugs complete ,all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PVC connections 15 mm size with PTMT nuts 600mm long complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm dia PVC (SWR) floor traps plain with grating including jointing with solvent cement complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing brass, chromium plated toilet paper holder fixed to wall with stainless steel screws complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15 mm bore 2 way Bib tap, brass chromium plated, fancy type, with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 25mm dia Stainless Steel curtain rod with fancy intermediate /end brackets/fennels etc complete, all as specified and directed.
Supply and fixing in repair plate rack made of minimum 0.8 mm thick stainless steel of size 750X 600x250mm with steel shelves and hanging arrangements for utensil complete ,all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair plate rack made of minimum 0.8 mm thick stainless steel of size 900x750x300 mm with steel shelves and hanging arrangements for utensil complete ,all as specified and directed by Engineer-in-Charge.
Supply and fixing as in repair stainless steel Grating 127mm (5'') size with locking system complete, all as specified and as directed by Engineer-in -charge.
Supply and fixing in repairs CP bathroom cloth Hooks set of five hooks solid body of best quality and fixed with stainless steel screws with pvc rawl plugs complete ,all as specified and directed as in repairs.
Supply and fixing in repair CP Brass Sink mixer(swan neck) with swivel spout (Wall Mounted ) 15mm bore dia pipe for mixing hot & cold water screwed down for iron pipe and fixed with connecting legs and wall flanges complete, all as specified and directed.
Supply and fixing in repair central hole washbasin ( swan neck) CP Brass mixer 15mm bore dia pipe for mixing hot & cold water screwed down for iron pipe and fixed complete, all as specified and directed by Engineer-in -charge.
Supply and fixing in repair CP brass Wall mixer system with L bend incl (provn for Over Head shower) , 15mm bore chromium plated fancy type complete ,all as specified.
Supply and fixing corner glass shelf assembly 5.5 mm thick toughened glass 300x300mm wide bevelled edge/ hatching of edges fixed with stainless steel "D" brackets with railing complete ,all as specified and directed by Engineer-in-charge.
Material & Labour PVC Nahani traps 100mm dia with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 fixed as complete, all as specified and directed by Engineer-in -charge.
Supply and fixing PVC(SWR) gully traps125/110 mm dia setting and jointing with cement solvent complete, all as specified and directed by Engineer-in -charge.
Supply and fixing in repair table top wash basin Vitreous China of size (600mm x 450mmx150mm),Square excluding taps, waste chain and plug and porcelain stopper all as specified and directed., including cutting for and pinning in ends of brackets or erecting stand bottle trap s/s etc complete ,all as specified by Engineer-in-Charge.(Sample as approved by GE).
Supply and fixing in repairs 2 way Pillar cock single lever of 450mm long fancy type , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete, all as specified by Engineer-in-Charge.
Supply and fixing soap dish of size 160x160x90mm ,fixed with plugs with chromium plated brass screws (for Baths of 3 cubical in each toilets) complete ,all as specified by Engineer-in-Charge..
Supply and fixing Tubular towel rod 600 mm , brass chromium plated, fixed to walls with plugs and chromium plated brass screws complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing single piece EWC of size 365x655x765mm with flushing cistern and connection pipe, P or S trap (closed pattern incl all necessary accessories like rag bolts, kitt /gel gasket etc, (including PVC seat cover ,CP jet with connector pipe complete ,all as specified and directed by Engineer-in-Charge.
Material & Labour for 75 mm thick PCC (1:3:6 ) type C-1 using 20 mm graded stone aggregate as in plinth protection laid in panels finish the top surfaces even and smooth without using extra cement including joint filling with sealing compound complete ,all as specified and directed by Engineer-in-Charge.
Material & Labour for 75 mm thick Cement concrete type D-2,1:4:8 (40mm graded aggregate) as in sub base of floors/path etc. complete, all as specified and directed by Engineer-in -charge.
Material & Labour for 16 to 18 mm thick granite slab (table rubbed polished) as in cooking platform , jamb, cill, step & riser setted and jointed with cement slurry and bedded over & including 15mm thick bedding layer of cement sand mortar (1:3), & pointed with white/ coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including grinding, rounded and chamfered edges and granite polishing etc complete, all as specified and as directed by Engineer-in-Charge.
Material & Labour for Broda Green Marble work 16 to 18mm thick (table rubbed and polished) in steps and riser, jambs, pillars, window cills,cooking platforms and bedded over & including 15mm thick bedding layer of cement sand mortar (1:3), & pointed with white/ coloured cement (1:2) using marble dust with admixture of pigment to match with marble shade of green marble ,including grinding, rounded and chamfered edges and granite polishing etc complete ,all as specified and as directed by Engineer-in-Charge.
Material & Labour Machine cut Kota stone slab flooring 16-18 mm thick, having minimum size 55 X 55 centimetres laid over & including 15 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified by Engineer-in-Charge.
Material & Labour Kota stone slab 16-18mm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick (average thickness) cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish), complete, all as specified by Engineer-in-Charge.
Material & Labour for kota/terrazzo tiles (old) of any description for polishing, grinding and waxing (whereever needed) upto 2nd cuttng to achieve granite finish complete, all as specified and as directed by Engineer-in-Charge.
Material & Labour Chequered cement concrete tiles 30mmx30mmx20mm thick with grey cement and pigment, over 15 mm thick screed in Cement mortar 1:6 set jointed and pointed in neat cement slurry in floors complete, all as specified and as directed by Engineer-in-Charge.
Taking down eaves gutter and AC/PVC/CI rain water pipe any size or pattern incl all fittings, heads, shoes, bends,Swan necks, etc including cleaning or refixing or removing to store (measured overall as fixed along centre line over fittings and accessories) complete ,all as specified and as directed by Engineer-in-Charge.
Supply and fixing UPVC (SCH-40) 110 mm bore pipes single socketed, in any lengths with rubber ring joints, fixed to wall with PVC clamp complete ,all as specified and directed by Engr-in-charge
Supply and fixing UPVC (SCH-40) 75 mm bore pipes single socketed, in any lengths with rubber ring joints, fixed to wall with PVC clamp complete, all as specified and directed by Engr-in-charge
Supply and fixing 110 mm bore PVC (SWR) bend of any radius with acess door complete, all as specified and directed by Engr-in-charge
Supply and fixing 75 mm bore PVC (SWR) bend of any radius with acess door complete, all as specified and directed by Engr-in-charge
Supply and fixing 110mm PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door complete, all as specified and directed by Engr-in-charge
Supply and fixing 75mm PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door complete ,all as specified and directed by Engr-in-charge.
Supply and fixing 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete, all as specified by Engr-in-charge
Supply and fixing 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete, all as specified by Engr-in-charge
Supply and fixing in repair PVC (SWR) vent cowl, 110mm dia complete ,all as specified by Engr-in-charge.
Supply and fixing kitchen sinks of stainless steel 1mm thick with drainage board with plugs,washer and waste coupling ;including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm X 460mm and bowl size 410mm X 330mm X 160mm complete ,all as specified by Engr-in-charge
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and including dismantling plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and directed by Engr-in-charge.
Material & Labour Providing and laying 60mm thick with glossy finish on top factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, with grey cement & pigment complete all as specified and as directed by Engr-in-charge.
Supply and fixing for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by Engr-in-charge.
Material & Labour for RCC (nominal Mix)1:2:4 (using 20mm graded aggregated ) as in beams, cantilever and lintels over 1.5 m span etc or similar items complete all as specified & directed by Engr-in-charge.
Material & Labour for RCC (nominal Mix)1:2:4 (using 20mm graded aggregated ) as in chajja or similar items complete all as specified and directed by Engr-in-charge.
Use & waste of form work for rough finished surface to side & soffit of beams, bressmers, cantilevers,and supports etc complete all as specified and directed by Engr-in-charge.
Use & waste of form work for rough finished surface of columns pillars,posts,struts,piers, and stanchions concrete square,rectangular or polygonal etc complete all as specified and directed by Engr-in-charge.
Use & waste of form work for Chullah hoods,Chajjas,troughs and similar item including edges etc complete all as specified and directed by Engr-in-charge.
Material & Labour form work to edges of concrete flats, not exc 20 cm wide horizontal or slopping and similar works exc 10 cm but not exc 20 cm wide complete all as specified and directed by Engr-in-charge
Material & Labour for welding in repairs exc 2.5 cm and not exc 5 cm in length, thickness of metal to be welded exc 9 mm but not exc 20 mm thick for connecting new and old reinforcement in any position complete all as specified and directed by Engr-in-charge.
Material & Labour running welding in repairs exceeding 9 mm but not exc 20 mm thickness of metal to be welded complete all as specified and as directed by Engineer-in-Charge.
Material & Labour preparation of existing surfaces like chippings of unsound weak/loose concrete/cover of reinforcement etccomplete all as specified and as directed by Engineer-in-Charge. Note :- Chippings of existing surfaces at the height upto 2nd/3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the complete site before quoting the rates.
Material & Labour for cleaning of existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose materials, diet etc, complete and applying two coats of alkaline rust converting primer with a coverage of 350 gms/sqm on the existing rebar and allowing it to react with rust for 6 hours and forming corroson resistant, insoluble and adherant protective layer, including cleaning the reinforcement with wire brushing to remove rust spalls, with time interval of 1 hour between the coats. (Measurement per sqm surface area of concrete). complete all as specified and directed by Engineer-in-Charge. Note :- The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit site and complete site before quoting the rates.
Material & Labour providing and application of zinc rich epoxy anticorrosive protective coating for rebar corrosion protection system in 2 coats of 0.40 kgs/sqm. The product should confirm carbonation resistance of 2 mm and bond strength < 1N/sqmm according to ASTM C 882-78. (Measurement will be surface area of concrete). complete all as specified and directed by Engineer-in-Charge. Note :- The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2th floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe-500 or height grade as per required diameter in various structural elements such as columns, beams and slabs etc, to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with ETA Approved Epoxy based as approved by GE complete all as specified and directed as the following :-
Drilling and rebaring of 10 mm dia x 160 mm deep.
Drilling and rebaring of 12 mm dia x 160 mm deep.
Drilling and rebaring of 16 mm dia x 160 mm deep.
Drilling and rebaring of 20 mm dia x 160 mm deep.
Note :- The work shall be executed using steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour for providing and application of corrosion inhibiting impregnation coating designed for use as an impregnation for protection of steel reinforcement within unexposed concrete in consumption of 0.5 kg/sqm complete all as specified and directed. The product should be amino alcohol and inorganic combination based migratory corrosion inhibitor for both cathodic and anodic protection. The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor .Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour for drilling holes of 12 mm dia upto 50 mm deep holes in structural members at the interval of 500 mm in staggered manner or along the crack line in Reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12 mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixtropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc, complete all as specified and directed.Note :- The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd /3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour for providing and mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer specification including preparation of surface by chipping and throughly cleaning of surface complete whereever required and as per directions of Engineer-in-Charge in consumption of 0.4 kgs/sqm. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa complete all as specified and directed by Engineer-in-charge.
Material & Labour for providing and applying 15-20 mm thick layer of single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortor confirming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have Compressive Strength > 55 MPa as per EN:12190, chloride iron content < 0.05% as per EN:1015-17, Adhesive bond > 2.0 MPa as per EN: 1542, Carbonation resistance dk < control concrete (MC(0,45)) as per EN: 13295 & Elastic modulus > 20.0 GPa as per EN: 13412 (Complete finished item with all leads and lifts) complete all as specified and directed by Engineer-in-charge. The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor .Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour for examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5-10 mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars upto 10 mm depth by low impact high frequency hammer/chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/paper bags, depositing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed by Engineer-in-charge. Note :- The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour for providing and applying single component, high build, elastomeric, crack-bridging, resistance to CO2 & SO2 and Chloride ion diffusion, UV resistant, breathable acrylic coating, with elongation at break exceeding 200% applied in two coats (each coat 100 micron DFT) on acrylic based primer at an average total thickness of 200 microns DFT in two coats including acrylic resin based primer as per the recommendation of the manufacturers complete all as specified and directed by Engineer in Charge. Note : Item rate inclusive of all materials, labours, supervision, tools, tackles, transportation, scaffolding/temporary supports/working platforms etc, complete as per specification and as directed.Note :- The work shall be executed for steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, 'U' Jack, base jacks, starting collor/diagonal braces, connecting pins etc to make the working platform strong and safe min size of platform 6 sqm. RCC repair/retrofitting work at the height upto 2nd/3rd floor.Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. The contractor is requested to visit the site and complete site before quoting the rates.
Material & Labour Providing and injecting chemical emulsion for Post Constructional antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-charge.
Material & Labour Providing and injecting chemical emulsion for Post Constructional antitermite treatment along external wall where the apron is not provided along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in-charge.
Material & Labour Providing and injecting chemical emulsion for Post Constructional antitermite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engr-in-charge.
Supply & fixing Factory made box type steel windows/ventilators with pressed steel frame complete included mild steel accessories like lugs, door stopper, holdfasts, pintol hinges, handles (minimum One for each shutter), and ISI marked tower bolt 150 mm size (minimum 2 for each shutter)etc. with or without glazing bars dovetailed or welded with one shop coat of zinc chromate primer , complete all as shown on drawing no. TD-276 (R) SH 1/4 to 2/4 , 3/4, 4 (R) /4 Note : (i) Fabrication as per TD-276 (R) SH 1/4 to 2/4, 3/4, 4 (R) /4 (ii)Mode of measurement Unit will be in Kilogram for the complete window except Glass / wire Gauge but incl fittings, ISI marked iron mongery and Grill/ Guard bar complete as per TD. The weight of windows will be finalized by the BOO to be convened by CWE before installation. The weight shall not include PCC back filling of the chowkhat. (iii) The PCC back filling in chowkhat of window, Sheet glass and wire gauge will be measured and paid separately against respective items.
Supply & fixing Stainless steel cupboard locks 2 lever with 2 Nos of keys complete all as specified and directed by Engr-in-charge.
Supply & fixing powder coated aluminium anodized sliding window (triple track) ( 02 Glass Shutter and 01 Wire mesh Shutter) standard section of size 92 x 31.75 x 1.6 mm for top & bottom track, section size 92 x 31.75x 1.4 mm for side frame, section size 39 x 17 x 1.4 mm for top and bottom shettur rail, section size 39 x 17 x 1.4 mm for outer style, section size 39 x 27x 1.4 mm for inter lock style including fabrication to required size and fixed with 5 mm floot sheet glass oridinary quality and stainless steel wire mesh, glazing, and rubber gas cut including aluminium beading, fitting etc with roller suitable spring catcher heavy duty, handle and locking arrangement complete including repair disturbed area to sides of windows with cement mortar 1:3 complete all as specified.all as specified and directed by Engr-in-Charge
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P.brass/ stainless steel screws, all complete as per drawings and the directionsof Engineer-in-Charge
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per drawings and the directions of Engineer-in-Charge
Material &Labour 1st class soft wood Handrails( moulded) 100 x 75mm rounded or shaped with splayed faces in straight lengths and fixed including polishing to achive smooth surface complete all as specified and directed by Engineer-in-Charge
Material &Labour Providing and applying Glyphosate chemical emulsion after and including removal / root out of trees,plants, truncks,grasses and creeps etc from roof or wall and applied to the cut surface of the trees,plants,truncks etc as per maufacturing instructions complete all as specified and directed by Engineer-in-Charge
Material &Labour for complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed., M&L for touch up putty application wherever required over the old painted wall @ 1kg per sq. mtr. Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty. M&l for one coat of waterproofing primer and damp-proof primer @ 1 Itr per 100 sq. undiluted to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface complete all as specified and directed.
Note :- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Oil bound distemper, putty etc after approval by the GE. (b) The Contractor shall produce "Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Removing of Nails, making good holes, cracks etc and preparation of surfaces. (e) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Sample patch of 10Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (j) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the efficieny of the Oil bound distemper for 3 yrs during the guarantee period.
Material and Labour for two coats of Efflorescence treatment on existing walls after removal of existing plaster(to be measured separately) using acrylic polymer modified viscous coating with minimum specific gravity of 1.35 and minimum weighed solid percentage of 61 by scrapping/cleaning the loose particles followed by 1st coat in horizontal direction and 2nd coat in vertical direction 3-4 hrs after 1st coat. Each coat to achieve a dry film thickness of 150-170 microns and minimum coverage will be 2-2.5 sqm/kg/2coats complete,all as specified and directed by Engineer –in-Charge .Note: The chemical should not be mixed with water.
Material and labour for complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed, after sanding, one coat of waterproofing primer and damp-proof primer @ 1 Itr per 60 sq. diluted with 10 % by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats.M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 64 saft diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
Note : -The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall produce "Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Removing of Nails, making good holes, cracks etc and preparation of surfaces. (e) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Sample patch of 10Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (j) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the efficieny of the weather proof paint for 5 yrs during the guarantee period.
Material & Labour Preparing old plastered surfaces of walls by brooming down and sanding with mechanical wall sander and applying one coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface complete all as specified and directed.
Note :- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Oil bound distemper, putty etc after approval by the GE. (b) The Contractor shall produce "Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Removing of Nails, making good holes, cracks etc and preparation of surfaces. (e) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Sample patch of 10Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (j) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the efficieny of the Oil bound distemper for 3 yrs during the guarantee period.
E&M WORK
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed by Engr-in-charge.
Taking down existing unserviceable MCB DB along with MCBs complete by disconnecting complete all as specified and directed by Engr-in-charge.
Taking down existing unserviceable T/Light fitting complete all as specified and directed by Engr-in-charge.
Taking down existing unserviceable sub main wiring with 2 Runs/4 Runs of 2.5/4/6 Sqmm aluminum/copper cable all as directed by Engr-in-charge.
Material & Labour for Point wiring concealed in walls complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor, drawn through in and including rigid non-metallic PVC concealed conduit medium grade minimum 25 mm dia and conduit accessories., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity , including sheet steel metal box of thickness 1.2mm ,modular base plate,modular cover plate, connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc., all as specified and as directed by Engr-in-charge.
One light point controlled by one, one way 6 Amps switch
One ceiling fan/ exhaust fan point controlled by one, one way 6 Amps switch
One 3 pin socket outlet 6 Amps on independent board
One 3 pin socket outlet 6 Amps on same board
One light point controlled by two, two way 6 Amps switches.
One bell/ buzzer point controlled by one bell push on same board with other switches or on independent board.
Material & Labour for Point wiring concelaed in walls complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor, drawn through in and including rigid non-metallic PVC concealed conduit medium grade minimum 25 mm dia and conduit accessories, including provision of PVC insulated 2.5 Sqmm FRLSH cable with copper conductor for earth continuity and including sheet steel metal box of thickness 1.2mm ,modular base plate,modular cover plate, connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc., all as specified and as directed by Engr-in-charge..
Material & Labour for Point wiring concealed in walls complete with 4 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC concealed conduit and conduit accessories., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor for earth continuity and including sheet steel metal box of thickness 1.2mm ,modular base plate,modular cover plate, connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc., complete all as specified and as directed by Engr-in-charge.
Material & Labour for Sub main wiring/power wiring complete with four runs of 6.0 Sqmm, single core, PVC insulated, unsheathed FRLSH cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe of medium grade minimum 25 mm dia concealed in walls and accessories, with one run of PVC insulated, 6.0Sqmm FRLSH copper conductor for earth continuity complete all as specified and as directed by Engr-in-charge.NOTE :- Four runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Material & Labour for Sub main wiring/power wiring complete with two runs of 6.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe of medium grade minimum 25 mm dia concealed in walls and accessories, with one run of PVC insulated, 6.0Sqmm FRLSH copper conductor for earth continuity all as specified and as directed by Engr-in-charge.. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body complete all as specified and directed by Engr-in-charge.
Supply and Fixing Ding Dong Bell AC. 230 volts,complete all as specified and as directed by Engr-in-charge.
Supply & Fixing 6 Amps 1 way one module switch complete all as specified and as directed by Engr-in-charge.
Supply & Fixing 6 Amps 3 pin socket two module complete all as specified and as directed by Engr-in-charge.
Supply & Fixing 6 Amps 2 way module switch complete all as specified and as directed by Engr-in-charge.
Supply & Fixing 16 Amps one way one module switch complete all as specified and as directed by Engr-in-charge.
Supply & Fixing modular multi socket outlet 6A/16 Amps 3/3 Pin socket 2 module complete all as specified and as directed by Engr-in-charge.
Supply and fixing Single pole and neutral enclosure with a three pin and earth plug with socket of capacity 20 Amp complete with one single pole MCB of capacity 20 Amp complete all as specified and as directed by Engr-in-charge.
Supply & Fixing 6 Amps bell push one module switch complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCB DB TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed by Engr-in-charge..
Supply and fixing MCB DB SPN 16 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed by Engr-in-charge..
Supply and fixing MCB DB SPN 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed by Engr-in-charge..
Supply and fixing MCB DB SPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, single door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed by Engr-in-charge..
Supply and fixing MCB SP 6-32 Amps 230 volts having breaking capaciy 6 KA , B curve ISI all as directed by Engr-in-charge.
Supply and fixing MCB SP 6-32 Amps 230 volts having breaking capaciy 6 KA , C curve ISI all as directed by Engr-in-charge.
Supply and fixing MCB TPN 63 Amp 230 volts C curve ISI marked all as directed by Engr-in-charge.
Supply and fixing MCB SPN 40 Amp 230 volts B curve ISI marked all as directed by Engr-in-charge.
Supply and fixing MCB SPN 32 Amp 230 volts B curve ISI marked all as directed by Engr-in-charge.
Supply and fixing MCB TPN 63 Amp 415 volts 10 KA B curve ISI marked all as directed by Engr-in-charge.
Supply and Fixing lamp holder,Batten/ angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitable for general lighting system complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED tube light with batten 1X18/20 watts LED, 230Volt energy efficient, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED Mirror tube light with batten 1X9 watts LED, 230Volt energy efficient, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED lamp 12 watts complete all as specified and as directed by Engr-in-charge.
Supply & fixing energy efficient Integral type 35 W 230 V LED Street light fitting outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engr-in-charge.
Material & Labour for street light bracket made out of 32 mm dia GI tubing light grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to building complete all as specified and as directed by Engr-in-charge.
Material & Labour for earthing with GI earth plate electrode 60cm x 60cm x 6.0 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4.0 mm dia by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Quoted rates deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Material & Labour Making of square/ circular hole 350mm in the stone masonry/Brick wall suitable for fixing exhaust fan of 300mm sweep including MS frame work of suitable size with nuts, bolts etc and sealing the sides of exhaust fan complete all as directed by Engr-in-charge.
Supply and fix Exhaust Fan, metal body AC single phase, 230 V of size 300mm sweep with minimum 900 rpm pre lubricated double ball bearing, Copper enameled wire winding, blades, frame and louvers including grouting nuts, fasteners and provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and as directed Note: (a) Type of blade leaves- CRCA MS sheet, No of blade leaves- Four, finish all exposed steel parts should be powder coated with minimum coating thickness of 50 microns, exhaust fan motor, totally enclosed type capacitor start, induction type with 'E' class insulation . (b) Taking down old unserviceable exhaust fan and depositing to MES store yard is deemed to be included in the overall rates quoted by the contractor.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, minimum 1200 rpm,2 nos bush bearing Copper winding of sweep 300mm with provision of flexible copper cable 3 core from ceiling rose to exhaust fan including fixing with suitable size of MS Nuts/Bolts complete all as specified and as directed by Engr-in-charge.
Supply and fix Electric water Heater, storage type steel body with MS glass lined inner tank and glass coated heating element of 1.5 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes and PRCD (Portable residual current device) complete all as specified and as directed by Engr-in-charge. Note: (1) Taking down old unserviceable geyser and depositing to MES store yard is deemed to be included in the overall rates quoted by the contractor. (2) Water supply pipe upto inlet of geyser and hot water outlet pipe along with necessary angle valve/ stop valve/ tap will be measured and paid under B/R schedule (3) PRCD can be inbuilt type or to be supplied separately in lieu of plug top with tripping current 30 mA & rating current 16A.
Supply and fixing ceiling fans, complete with three blades, down rod,modular electronic regulator and accessories, accessories 230V, 1200mm sweep. Five star rated with brushless direct current motor(BLDC). Note: Rate for taking down old unserviceable ceiling fan and depositing to MES store yard is deemed to be included in the overall rates quoted by the contractor.Note: Make of BLDC fan & regulator shall be same.
Supply and fix ceiling fans, complete with three blades, down rod,modular electronic regulator and accessories, accessories 230V, 1400mm sweep. Five star rated with brushless direct current motor(BLDC). Note: Rate for taking down old unserviceable ceiling fan and depositing to MES store yard is deemed to be included in the overall rates quoted by the contractor.Note: Make of BLDC fan & regulator shall be same
Supply and fixing stainless steel electric kitchen chimney 60cm with 1000 cum/hr suction,intelligent auto clean, curved glass, baffle filter, revolutionary motion senser control,oil collector tray with inbuilt LED light including aluminium flexible pipe of diameter 150mm 8.5 feet long after expansion with all accessories including clamps all as specified and directed by Engr-in-charge.
Supply and fixing UPVC pipe of dia 150mm SCH 40 for kitchen chimney exhaust including connection with flexible chimney pipe, fixed on wall with clamps and necessary nuts and bolts for chimney exhaust outside kitchen all as specified and as directed by Engr-in-charge.
Material & Labour for making circular/ square hole for chimney vent for UPVC pipe of dia 150mm in the stone masonry/ brick wall all as specified and as directed by Engr-in-charge.
Note: For the purpose of arriving at Contract sum, the amount of Schedule of credit (i.e Rs 832094.00) shall be deducted from the total amount arrived.
Siya constructions (BID ID -3172932)
NARINDER KUMAR SONS (BID ID -3168135)
M/S MANI GARG CONTRACTOR (BID ID -3162420)
M/S Mukesh Kumar Gupta (BID ID -3179928)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .