Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.0 LAccepted-Finance 209 SEWAK COLONY PATIALA 209 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 1 | Accepted-Finance Accepted | |
| 2 | Not Admitted-Fee/PreQual/Technical 214 SEWAK COLONY NR NEW DELHI PLAZA HOTEL 981 PATIALA PUNJAB 147001 | PATIALA | PUNJAB | 147001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S Sainico Electricals L1 |
|---|---|---|---|---|
| 1.01 | Supply and Erection of Intelligent Co-ordinate Traffic Light Control System with following features: Compact Next Generation Hardware and User friendly GPRS enabled system, 32 bit Microcontroller based, Pole mountable, Master and Slave architecture, Control up to 16 slaves, 16 independent lamp outputs per slave and for master, Inductive, Integrated custom keyboard and LC Display, Lamp monitoring, Programmable intensity control, Remote Administration and Monitoring from central computer, Area Traffic Control System (ATCS) compatible, 12VDC/220V AC Operation. Technical Specifications- AT91SAM7X512 processor with 512K flash and 128 k RAM, Drive 16 lamps per controller and delivers current of 2A max per channel, GPS based Real Time Clock (RTC) with battery back up, PORTS: RJ45, CAN(for redundant communication channel),USB device port (USB), Wireless transceiver operating on unlicensed ISM band of 2.4 GHz and 868 MHz, Vehicle sensor module interface ,12 VDC operation at 4.2 Watts, Plan entering and retrieval using user interface (LCD and keypad) 1. 24x7 working Standbymode 2. Standby working using the pre-configured data 3. Isolated modules 4. Master- Slave model 5. Continuous monitoring for a) Lamps working status b) Voltages c) Currents 6. Wireless communication using zigbee 2.4GHz ISM Band 7. Supports Cantilever and normal poles 8. Low power consumption 9. Central connectivity with GPRS (optional) 10. User friendly Software for the configuration, monitoring and controlling 11. Programmable intensity control to optimize the solar power 12. Junction capacity: a) Up to 10Ways b) One master and up to 40 slaves can be accommodated 13. Operating modes a) Auto mode - With pre-configured plans b) Flash/Blinker mode - c) Manual mode - Manual signals d) Power down mode - Sleep mode CMU CARD 1. 24x7 monitoring and controlling 2. Daily backup for monitored data 3. User friendly configurations 4. Junctions connectivity options a) Serial 5. Max 254 junctions can be connected to one application 6. Each junction can be configured up to Max of Ways 10 Slaves 40 Sequences 32 plus 1(Blinker) Combinations per sequence 80 Day plans 7(week days) plus 6(custom days) Holidays 30 Intensity plans 24 Intensity configurations 64 7. Configure - Download and Forget mechanism i.e., Junction does n’t depends on the software after downloading the Configuration to it. Also Pre-configure data (Configure once - Use many times) 8. Instant fault triggering to minimize the MTTR(Mean Time To Recover) 9. System Control a) Data base downloading b) VIP Movement c) Emergency Sequence plan d) Any junction can be controlled from the CMU at any time 10. Software requirements a) OS: Windows XP / 7(Recommended) b) RAM: 512 MB c) Size: ~5.2MB d) Platform: Delphi e) Drivers: Intelligent control unit 1. No of masters per junction: 1(One) 2. Capacity:Up to 40 slaves per junction 3. Data: Pre-configured data base loaded in master 4. Time synchronized with GPS to maintain the Unique standard time 5. 2x24 LCD and 4x3 Keypad is provided to get the junction information 6. Sequences smooth change will be taken place 7. Monitoring: a) Junction status and faults b) Information from slaves and their poles like health, configurations, status,solar and battery information 8. Controlling: a) Slaves will be controlled by master continuously. b) All slaves will be synchronized in time with respect to master. 9. Communication: a) Master - Slave: Zigbee 2.4GHz b) Master - CMU: GPRS(optional) 10. Technology: a) Micro-controller: LPC2368 b) Family: ARM - 7 TDMI c) Memory: Nonvolatile memory to store configurations 11. Power: a) Voltage: 12V or 24V DC (-10%, plus 20%) b) Max Current: 0.8A/12V or 0.4A/24V c) Max power: 9.6W (Peek pulse) - 2W(Average) Vehicle Actuataion /Leeplap Software Enabled | 1 | Each | 85,000 ₹85,000 Lowest |
| 1.02 | Supply and Erection of LED aspects as per following specifications and standards:- LATEST CLUB DESIGN WITH Backside TRACK LINE for Easy Fitting and Semi Flat Crystel Clear Glass. Polycarbonate signal aspects of impact resistance, UV stabilized, Fast dyed, Unbreakable, rust and rain proof and anticorrosive, no metallic components parts used single walled including aluminum basket for led,s retrofit kit with brass nb, texture non reflective from surface ,hdpe detachable sun visors and LED’s based lamp from giving balanced light output intensity with tolerable limit and with appropriate colors and necessary mounting arrangements. a) RED/Amber Led,s Signal Aspect 12/24Volt Solar Operative Led’s Viewing angle -23deg. Led,s Forward current-20ma Total no of Led’s -190no. Total consumption -10W max. Intensity of Led aspect-260cd minimum | 24 | Each | 6,250 ₹1,50,000 Lowest |
| 1.03 | Supply and Erection of LED aspects as per following specifications and standards:- LATEST CLUB DESIGN WITH Backside TRACK LINE for Easy Fitting and Semi Flat Crystal Clear Glass. Polycarbonate signal aspects of impact resistance, UV stabilized, Fast dyed, Unbreakable, rust and rain proof and anticorrosive, no metallic components parts used single walled including aluminum basket for led,s retrofit kit with brass nb, texture non reflective from surface ,hdpe detachable sun visors and LED’s based lamp from giving balanced light output intensity with tolerable limit and with appropriate colors and necessary mounting arrangements. Green Colour LEDs Signal Aspect Led’s Viewing angle -23deg. Led,s Forward current-10ma Total no of Led’s -66 nos. Total consumption -4W max. Intensity of Led aspect-260cd minimum. | 24 | Each | 6,250 ₹1,50,000 Lowest |
| 1.04 | Revised rates: Cantilever poles: - This signal post consists of 3 sections 6”/5”/2” dia made from mild steel B class pipes. The tubes are joined by tempering outer tube signal post is capable of Holding vehicular as well as pedestal faces the overhang assembly is provided for minimum clearance of pole from G/L Total height of Pole varies from 8 mtr. Pole is further Divided in two sections and is joined with the help of flanges for easy transportation M.S Poles have also a Solar Panel Installation Stands Mounting Cross and Channel size 35x5mm 4 nos. with2x2 feet Triangle on the Base for Pole support including required RCC in Base Foundation. | 4 | Each | 29,500 ₹1,18,000 Lowest |
| 1.05 | Supply and erection of Turner type Black sheathed PP copper wire 10 core 23/76 for Aspects Connection with Slaves as per site requirement (alloted rates) | 160 | Metre | 415 ₹66,400 Lowest |
| 1.06 | Supply and erection of Jumbo Big Display Count Down Timer with Three stages Display with 12 height” Digital display in Red Leds, Complete showing Red/Amber/Green Timings (operative with Slave and 12Volt Power source) (Alloted rate) | 4 | Each | 19,500 ₹78,000 Lowest |
| 1.07 | Power Source:-Supply and erection of Power Back Supply unit for Poles for Independent Slaves as following features:- Night Dimmers with Low Battery usage software based Systems included a) Input: -160-280 b) Output: -230VAC plus 0.5 c) Charger:-Solar Charge Controller/SMPS based Charging System.0-20Amp d) Power source tech (EPG):- MPWMM, Efficiency-90% e) Technology: -MBT f) Waveform 1Disortation -5% approx. g) Batteries:- 2 nos Exide/ Amron) Rating: - 100A h 12V or 24V i) CVR:- included 180-220 j) CVT:-included 180-220 k) Including off line CVT as per (IRS) l) Quality Assurance: -ISI Standards Approved | 1 | Each | 65,000 ₹65,000 Lowest |
Tender Value
₹5.8 L
EMD Value
₹10,500
Closing Date
3 Mar 2026, 5:00 pmClosed
Narender Singh Suhag
Municipal Corporation Yamunanagar
Installation of Traffic light signal system at Bus stand Jagadhri chowk in M.C Yamunanagar-Jagadhri. (RECALL)
2026_HRY_504982_1
2026A9D1F1CF F920 405E B50E 44F1FC610B1C288ULB
Open Tender
Civil Works
Works
55 days
Jagadhari
2 documents required · 2 mandatory
₹1,000
₹10,500
Yes
20 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
3 Mar 2026
25 Feb 2026
Supply and Erection of Intelligent Co-ordinate Traffic Light Control System with following features: Compact Next Generation Hardware and User friendly GPRS enabled system, 32 bit Microcontroller based, Pole mountable, Master and Slave architecture, Control up to 16 slaves, 16 independent lamp outputs per slave and for master, Inductive, Integrated custom keyboard and LC Display, Lamp monitoring, Programmable intensity control, Remote Administration and Monitoring from central computer, Area Traffic Control System (ATCS) compatible, 12VDC/220V AC Operation. Technical Specifications- AT91SAM7X512 processor with 512K flash and 128 k RAM, Drive 16 lamps per controller and delivers current of 2A max per channel, GPS based Real Time Clock (RTC) with battery back up, PORTS: RJ45, CAN(for redundant communication channel),USB device port (USB), Wireless transceiver operating on unlicensed ISM band of 2.4 GHz and 868 MHz, Vehicle sensor module interface ,12 VDC operation at 4.2 Watts, Plan entering and retrieval using user interface (LCD and keypad) 1. 24x7 working Standbymode 2. Standby working using the pre-configured data 3. Isolated modules 4. Master- Slave model 5. Continuous monitoring for a) Lamps working status b) Voltages c) Currents 6. Wireless communication using zigbee 2.4GHz ISM Band 7. Supports Cantilever and normal poles 8. Low power consumption 9. Central connectivity with GPRS (optional) 10. User friendly Software for the configuration, monitoring and controlling 11. Programmable intensity control to optimize the solar power 12. Junction capacity: a) Up to 10Ways b) One master and up to 40 slaves can be accommodated 13. Operating modes a) Auto mode - With pre-configured plans b) Flash/Blinker mode - c) Manual mode - Manual signals d) Power down mode - Sleep mode CMU CARD 1. 24x7 monitoring and controlling 2. Daily backup for monitored data 3. User friendly configurations 4. Junctions connectivity options a) Serial 5. Max 254 junctions can be connected to one application 6. Each junction can be configured up to Max of Ways 10 Slaves 40 Sequences 32 plus 1(Blinker) Combinations per sequence 80 Day plans 7(week days) plus 6(custom days) Holidays 30 Intensity plans 24 Intensity configurations 64 7. Configure - Download and Forget mechanism i.e., Junction does n’t depends on the software after downloading the Configuration to it. Also Pre-configure data (Configure once - Use many times) 8. Instant fault triggering to minimize the MTTR(Mean Time To Recover) 9. System Control a) Data base downloading b) VIP Movement c) Emergency Sequence plan d) Any junction can be controlled from the CMU at any time 10. Software requirements a) OS: Windows XP / 7(Recommended) b) RAM: 512 MB c) Size: ~5.2MB d) Platform: Delphi e) Drivers: Intelligent control unit 1. No of masters per junction: 1(One) 2. Capacity:Up to 40 slaves per junction 3. Data: Pre-configured data base loaded in master 4. Time synchronized with GPS to maintain the Unique standard time 5. 2x24 LCD and 4x3 Keypad is provided to get the junction information 6. Sequences smooth change will be taken place 7. Monitoring: a) Junction status and faults b) Information from slaves and their poles like health, configurations, status,solar and battery information 8. Controlling: a) Slaves will be controlled by master continuously. b) All slaves will be synchronized in time with respect to master. 9. Communication: a) Master - Slave: Zigbee 2.4GHz b) Master - CMU: GPRS(optional) 10. Technology: a) Micro-controller: LPC2368 b) Family: ARM - 7 TDMI c) Memory: Nonvolatile memory to store configurations 11. Power: a) Voltage: 12V or 24V DC (-10%, plus 20%) b) Max Current: 0.8A/12V or 0.4A/24V c) Max power: 9.6W (Peek pulse) - 2W(Average) Vehicle Actuataion /Leeplap Software Enabled
Supply and Erection of LED aspects as per following specifications and standards:- LATEST CLUB DESIGN WITH Backside TRACK LINE for Easy Fitting and Semi Flat Crystel Clear Glass. Polycarbonate signal aspects of impact resistance, UV stabilized, Fast dyed, Unbreakable, rust and rain proof and anticorrosive, no metallic components parts used single walled including aluminum basket for led,s retrofit kit with brass nb, texture non reflective from surface ,hdpe detachable sun visors and LED’s based lamp from giving balanced light output intensity with tolerable limit and with appropriate colors and necessary mounting arrangements. a) RED/Amber Led,s Signal Aspect 12/24Volt Solar Operative Led’s Viewing angle -23deg. Led,s Forward current-20ma Total no of Led’s -190no. Total consumption -10W max. Intensity of Led aspect-260cd minimum
Supply and Erection of LED aspects as per following specifications and standards:- LATEST CLUB DESIGN WITH Backside TRACK LINE for Easy Fitting and Semi Flat Crystal Clear Glass. Polycarbonate signal aspects of impact resistance, UV stabilized, Fast dyed, Unbreakable, rust and rain proof and anticorrosive, no metallic components parts used single walled including aluminum basket for led,s retrofit kit with brass nb, texture non reflective from surface ,hdpe detachable sun visors and LED’s based lamp from giving balanced light output intensity with tolerable limit and with appropriate colors and necessary mounting arrangements. Green Colour LEDs Signal Aspect Led’s Viewing angle -23deg. Led,s Forward current-10ma Total no of Led’s -66 nos. Total consumption -4W max. Intensity of Led aspect-260cd minimum.
Revised rates: Cantilever poles: - This signal post consists of 3 sections 6”/5”/2” dia made from mild steel B class pipes. The tubes are joined by tempering outer tube signal post is capable of Holding vehicular as well as pedestal faces the overhang assembly is provided for minimum clearance of pole from G/L Total height of Pole varies from 8 mtr. Pole is further Divided in two sections and is joined with the help of flanges for easy transportation M.S Poles have also a Solar Panel Installation Stands Mounting Cross and Channel size 35x5mm 4 nos. with2x2 feet Triangle on the Base for Pole support including required RCC in Base Foundation.
Supply and erection of Turner type Black sheathed PP copper wire 10 core 23/76 for Aspects Connection with Slaves as per site requirement (alloted rates)
Supply and erection of Jumbo Big Display Count Down Timer with Three stages Display with 12 height” Digital display in Red Leds, Complete showing Red/Amber/Green Timings (operative with Slave and 12Volt Power source) (Alloted rate)
Power Source:-Supply and erection of Power Back Supply unit for Poles for Independent Slaves as following features:- Night Dimmers with Low Battery usage software based Systems included a) Input: -160-280 b) Output: -230VAC plus 0.5 c) Charger:-Solar Charge Controller/SMPS based Charging System.0-20Amp d) Power source tech (EPG):- MPWMM, Efficiency-90% e) Technology: -MBT f) Waveform 1Disortation -5% approx. g) Batteries:- 2 nos Exide/ Amron) Rating: - 100A h 12V or 24V i) CVR:- included 180-220 j) CVT:-included 180-220 k) Including off line CVT as per (IRS) l) Quality Assurance: -ISI Standards Approved
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
[23.27.4]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 4. M.S. pedestal of size 900 mm wide , 1500 mm high , 450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1050 mm x 600 mm x 200 mm above ground level ,having a base of size 1200 mm x 750 mm x 250 mm below ground level . 0 0 [Through Rate]
[23.5.6.9]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.9. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.11.23]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 23. 16 Sq mm 4 core (UnArm.) [Through Rate]
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]
[24.4.16]STREET LIGHT 16. Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections . [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_583700.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .