Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹19.4 L+₹2.2 L (13.0%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹19.9 L+₹2.8 L (16.1%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹24.2 L+₹7.0 L (41.0%)Rejected-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Jun 2020, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT OF STREET LIGHT, SECURITY LIGHT IN DOMESTIC AREA AT AF STN JODHPUR
2020_MES_341252_1
8400/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
30 Jun 2020
27 Apr 2020
12 Jun 2020
27 Apr 2020
10 Jun 2020
18 May 2020
Amount
Attending day to day street / security light (of any type and make, installed at various locations of domestic area & 33SU site 1A & 1B at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), GI Socket, replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, MCB, MCCB, Contactor etc replacement of straight through joint and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of schedule 'A'/BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply & fixing in repair GI pipe bracket, made out of 40 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair GI pipe bracket, made out of 25 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair MS clamps, suitable for PCC/Steel tubular pole, fabricated into shape and size as required suitable for street light brackets of GI pipe 40/25 mm bore, with MS nuts & bolts including painting with one coat of red oxide primer and two coats of aluminium paint complete all as specified & directed by the Engineer-in-Charge.
Supply only 4 sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only 6 sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only 10sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only starter for fluorescent street light fitting 24 Watt complete all as specified by Engineer-in-Charge.
Supply only fluorescent tube rode T5 type 24 watt of make as existing at site complete all as specified by Engineer-in-Charge.
Supply only electronic ballast suitable for T5 HO lamps 2x24 watt/4x24 watt complete all as specified by Engineer-in-Charge.
Supply only lamp holder Single/Double ended suitable for HPSV/MH street light fittings of 1x 70/150/250/400 watt of make as existing at site complete all as specified by Engineer-in-Charge.
Supply only copper ballast of capacity 150 watt for HPSV/MH street light fittings complete all as specified by Engineer-in-Charge.
Supply only copper ballast of capacity 250 watt for HPSV/MH street light fittings complete all as specified by Engineer-in-Charge.
Supply only copper ballast of capacity 400 watt for HPSV/MH street light fittings complete all as specified by Engineer-in-Charge.
Supply only metal halide lamp 250 watt single/double ended of make as existing at site complete all as specified by Engineer-in-Charge. Make- Bajaj/Philips/ Crompton Greaves
Supply only metal halide lamp 400 watt single/double ended of make as existing at site complete all as specified by Engineer-in-Charge. Make- Bajaj/Philips/ Crompton Greaves
Supply only metal halide lamp 150 watt single/double ended of make as existing at site complete all as specified by Engineer-in-Charge. Make- Bajaj/Philips/ Crompton Greaves
Supply only ignitor for HPSV/MH 70/150/250/ 400 watt light, of make as existing at site complete all as specified by Engineer-in-Charge.
Supply only capacitor suitable for 70/150/250/400 watt MH/HPSV light fitting, of make as existing at site complete all as specified by Engineer-in-Charge.
Trimming/cutting the tree branches/ bushes around the LT overhead line/panel and making safe clearance up to 2.00 metre distance from line wire/panel all as directed by Engineer-in-Charge.
Material and labour for unbinding ACSR conductor and insulators from the poles and restringing and fixing of same ACSR conductor on same poles and insulators including making/tightening of jumpers at appropriate place to ACSR Conductor at site all as specified and directed by Engineer-in-Charge. Note: All wires between pole to pole shall be restringed and measured as one length. Distance between pole to pole shall be considered for the purpose of payment.
Supply only FRP Junction box for street light central with linked door control including 6 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights complete with pole mounting type size 300x200x105mm complete all as specified by Engineer-in-Charge.
Supply only electric driver for 50 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only electric driver for 60 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only electric driver for 72 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only electric driver for 90 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only electric driver for 120 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only electric driver for 150 Watt LED type light fitting complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified by Engineer-in-Charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only LED street light 72 Watt with IP 65, 230 Volt with all connected acessories required as directed by Engr-in-charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only LED street light 90 Watt with IP 65, 230 Volt with all connected acessories required as directed by Engr-in-charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only LED street light 60 Watt with IP 65, 230 Volt with all connected acessories required as directed by Engr-in-charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Supply only LED flood light 150W with IP66 protection with all necessary accessories required for fitting as directed by Engr-in-charge. Make- Phillips, C&S, Crompton Greaves, BAJAJ, Wipro
Attending day to day complaints of existing 12 m high highmast light (of any type, make and wattage installed at various locations in domestic area & 33 SU site 1A and 1B at AF station jodhpur) received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of flexible wire, MH choke, MH/Sodium lamp, ignitor, lamp holder, driver, SPD, PCB, Contactor, MCB, MCCB replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment etc, properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of schedule 'A'/BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Material & labour for repair of mechanism of High mast and rewinding of three phase tower motor 440volt AC if burnt and incl. dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
Material & labour for General servicing of Highmast light fitting with pole and accessories etc including oiling, greasing in gear system, chain, rope wire etc; alignment of Light holder ring, checking for the serviciability of electric motor, gear system, functionality of rope wire and other connected parts for serviciability of highmast and rectification of defects including replacement of unserviceable nuts, bolts, fixing of broken chains and making the high mast fully functional upto the entire satisfaction of Engineer-in-charge complete all as specified and directed.
Supply only straight through joint heat shrinkable type for LT cable 10 sqmm 02 core 1100 Volt grade complete all as specified by Engineer-in-Charge.
Supply only straight through joint heat shrinkable type for LT cable 16 sqmm 02 core 1100 Volt grade complete all as specified by Engineer-in-Charge.
Supply only straight through joint heat shrinkable type for LT cable 25 sqmm 3.5 core 1100 Volt grade complete all as specified by Engineer-in-Charge.
Supply & fixing in repairs rigid PVC, LT line spacers for two lines all as directed by Engineer-in-Charge.
Supply & fixing in repairs rigid PVC, LT line spacers for four lines all as directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 10 Sqmm 02 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 25 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Excavation in trenches, trenches not exc 1.5 M wide and not exc. 1.5 M in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 m and deposing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and filling dry clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be maesured and paid
Laying only 40 to 50 mm thick rough dressed sq mtr. Jodhpur type stone slab cover 25 to 30 cm wide and 80 cm in length received from excavation, laid dry abutting each other for under ground protection complete all as specified and directed.
Material & labour for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Material & labour for Aviation obstruction LED light fitting 240 volt low intensity twin aviation light of power consumption 10 watt in total, dismantling and taking down the old unserviceable fitting from the poles/walls complete all as specified and directed by the Engineer-in-Charge.
Material & labour in repair for prestressed cement concrete pole, 9 m long, 152 mm x152 mm at top and 152 mm x 260 mm at bottom, class 9 including excavation in any type of soil, returning and filling in, removal of surplus soil to a distance as directed and including PCC 1:3:6 type B2 (using 40 mm graded stone agrregate) in foundation and pedestal etc complete all as specified and directed by the Engineer-in-Charge.
Supply only three Pole Contactor 25/50Amp 240V AC complete all as specified and directed by the Engineer-in-Charge.
Supply only two Pole Contactor 40/63/75Amp 240VAC complete all as specified and directed by the Engineer-in-Charge.
Supply only MCBs of 'C' of Single pole 6 to 32 amp series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply only MCBs of 'C' of SPN 40 amp series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size complete all as specified and directed by the Engineer-in-Charge. .
Supply only MCCB four pole 63 Amps, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, including lugs as required complete all as specified and directed by the Engineer-in-Charge.
Supply only MCCB four pole 100 Amps, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, including lugs as required complete all as specified and directed by the Engineer-in-Charge.
Material & labour in repairs for aluminium conductor, steel reinforced (ACSR) including 22 gauge aluminium binding wire, line connections and jumper etc (Squirrel, weasel & ferret) complete all as specified and directed by the Engineer-in-Charge. Note :- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
Supply & fixing in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take THREE phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps. Make:- Cat part No Swadeep 02EC-8KW3P or equivalent in legrand, siemens.
Supply & fixing in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: Single phase load of 8KW, Contactor Rating 63Amps, MCB SP 63Amps, circuit wiring-16sqmm. Make:- Cat part No Swadeep 02EC-8KW1P or equivalent in legrand, siemens.
Dwarka Enterprises
Shri Electrical Enterprises
M/s. Dhananjay Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .