Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC NEAR KRIPAN GATE BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹46.2 L+₹65,957.14 (1.45%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDR | |
| 3 | L3₹47.7 L+₹2.2 L (4.81%)Rejected-Finance DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDR | |
| 4 | L4₹48.1 L+₹2.5 L (5.59%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDR | |
| 5 | L5₹48.3 L+₹2.8 L (6.07%)Rejected-Finance VILL DURGA NAGAR CHECK POST PO ETHELBARI DIST ALIPURDUAR PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDR |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
10 Sept 2022, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
SPL REPAIR / REPLACEMENT OF EXISTING SEWAGE LINE BOTH SIDE OF BLDG NO P-1 AND SEPTIC TANK AND SPL REPAIR TO SECURITY FENCE AT BINNAGURI MIL STATION UNDER GE (S) BINNAGURI
2022_MES_546558_1
8517/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹92,000
Yes
2 Nov 2022
20 Aug 2022
12 Sept 2022
20 Aug 2022
10 Sept 2022
3 Sept 2022
Amount
Schedule 'A'
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or shafts, manhole, sewage line etc and getting out in soft /loose complete all as directed.
Returning filling in inluding spreeding, leveling, watering and well ramming in layers not exc 25 cm thick in soft /loose soil complete all as directed.
Removing excvated material (Soil) not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L in repair for salt glazed stone ware drain pipe grade-A, conform to IS-651-1980, 150mm dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and as directed.
M&L in repair for salt glazed stone ware drain pipe grade-A, conform to IS-651-1980, 200mm dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and as directed.
M&L for 150mm thick concrete bed to drain pipe (200mm bore) with PCC (1:3:6) type D2 using 40mm graded stone aggregate including packing under and haunching aginnst the sides of pipe after they are laid jointed and tested complete all as specified and as directed.
M&L for 100mm thick concrete bed to drain pipe (150mm bore) with PCC (1:3:6) type D2 using 40mm graded stone aggregate including packing under and haunching aginnst the sides of pipe after they are laid jointed and tested complete all as specified and as directed.
S&F salt-glazed stoneware gully traps, square or round mouthed, type `P' fo size 180X150mm complete all as specfied and directed.
Cutting into existing man holes for connecting new drains making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 150mm all as specified and directed .
Cutting into existing man holes for connecting new drains making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 200mm all as specified and directed .
S&F cast iron work grade FG 150, article weight not exceeding 5 Kg Each unmachined, as in covers to manhole , Gulley trap etc with locking arrangement complete all as specfied and directed .
Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded aggregate) as in coping of manholes, channels etc complete all as specified and directed.
M&L for Mild steel TMT bars 8mm dia , cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and directed.
M&L for providing RCC 1:2:4 type B-1( using 20mm graded stone aggregate) as in precast cover slabs (for Manholes etc) and the like with plain faces and set in CM(1:4) including formwork complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radious in wall built in CM(1:6) complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radious in half brick thick wall built in CM(1:4) complete all as specified and directed.
M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 user as per IS code IS : 2470 ( Part 1 ) - 1985 CODE OF PRACTICE FOR INSTALLATION OF SEPTIC TANKS ( Second Revision ) complete all as specified and directed.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 4.5 M effective depth complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:3 as in fair faces of brick work or concrete surface of wall and finished surface even and fair without using extra cement with using wpc as per manufacturer instruction (measure seperately)complete all as specified and directed.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
Material and labour for preparation of new plastered or unplastered surafces of wall and applying two coats of white wash complete all as specified and as directed.
Material and labour for 50mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in flooring and finished the surface even and smooth with using extra cement or ramp etc including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed. complete all as specified and as directed .
M & L for 40 mm thick cement concrete 1:2:4 type B1 rendered smooth with extra cement complete all as specified and as directed.
Dismantling post or strut any section including taking out embedded portion and making good disturbed ground post embedded natural ground complete all as specified and as directed.
Dismantling post or strut any section including taking out embedded portion and making good disturbed ground post embedded in concrete or in brick masonry complete all as specified and as directed.
Dismantlimg fencing wire mesh any type complete all as specified and as directed.
S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc., complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removal excess soil to at a distance 50 m and making good surface(soft or loose soil) complete all as specified and as directed.
M&L for Cement concrete type D2 1:4:8 (40mm graded aggregate)in foundations filling and mass concrete complete all as specified and as directed.
M&L for Reinforced Cement Concrete 1:1.5:3 nominal mix using 20mm graded stone aggregate in Columns, Pillars,piers, posts and struts complete all as specified and directed.
M& L for Cement concrete in foundations, filling and mass concrete type C-2 1:3:6 using 40 mm graded aggegrate as in PCC complete all as specified and as directed.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.complete all as specified and directed.
Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L for Mild steel round bar 6mm dia for nibs in fencing post complete all as specified and directed.
Form work to rough finished flat Form work to sides of concrete foundations, rafts, plinth beams and similar work, vertical or batter complete all as specified and directed.
Form work to fair finished surfaces sides of Pillars,posts,struts,columns and stanchions of Square, rectangular or polygonal. complete all as specified and directed.
M&L in repair for flat iron in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or revetting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only Chain link MS galvanised fencing any size or type exc 1.9 Kg per square metre complete all as specified and directed. Note:-Weight of chain link fencing will be ascertain by BOO.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
L. B. SHARMA
M/S MOHAN KUMAR BANSAL
N K Construction
SHRI ARABINDA GHOSH
M/S SINHA ENTERPRISE
R K AGARWAL
M/s. RAMPHAL GARG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .