Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | ₹41.5 L Quoted ₹42.0 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹45.1 L+₹3.1 L (7.38%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹45.1 L+₹3.1 L (7.38%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹48.5 L+₹6.5 L (15.4%)Rejected-AOC | ₹48.5 L+₹6.5 L (15.4%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected due to not enlisted in appropriate category. |
| Sl No | Description | Qty | Unit | Shree Builders L3 | Abhishek Enterprises L2 | JYOT ENTERPRIES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed. | 3,140 | PER POINT | 19 ₹59,660 | 18 ₹56,520 Lowest | 20 ₹62,800 |
| 2.00 | M&L for servicing of ceiling fans 1200/1400mm sweep any make, model after disconnecting electricity from ceiling rose, taking down the fan, strip opening of stator & rotor, proper cleaning of all bearing, bushes, blade, providing oiling, greasing, including small spare parts like washer etc, re-assembling the same, writing ceiling fan number, or aplying sticker for the same & testing & re-hanging the celling fan of 230 V AC complete all as specified and directed. | 1,500 | EACH JOB | 85 ₹1,27,500 | 80 ₹1,20,000 Lowest | 150 ₹2,25,000 |
| 3.00 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and modular sunken boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One light/fan/bell/exhaust point controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 1,000 | PER POINT | 1,050 ₹10,50,000 | 950 ₹9,50,000 | 690 ₹6,90,000 Lowest |
| 4.00 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sunken for boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp same board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 120 | PER POINT | 950 ₹1,14,000 | 750 ₹90,000 | 220 ₹26,400 Lowest |
| 5.00 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12& including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp Indepedent board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 350 | PER POINT | 850 ₹2,97,500 | 950 ₹3,32,500 | 690 ₹2,41,500 Lowest |
| 6.00 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12 & including with multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed for the following :-Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 250 | PER POINT | 1,100 ₹2,75,000 | 1,050 ₹2,62,500 Lowest | 1,190 ₹2,97,500 |
| 7.00 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multi stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12 & including with multi stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed for the following :-Note: per point lenght of cable should be 7 to 15 mtr . | 80 | PER POINT | 1,250 ₹1,00,000 Lowest | 1,300 ₹1,04,000 | 1,490 ₹1,19,200 |
| 8.00M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade non flamble heavy duty with decorative casing & caping including elbow,tee,junction boxes double lock type 32mm in size,sunken boxes,plate 4,6,8,10,12 modulare plate, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :--Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | ||||||
| 8.01 | (a) One light/fan point controlled by one switch | 850 | PER POINT | 775 ₹6,58,750 | 750 ₹6,37,500 | 590 ₹5,01,500 Lowest |
| 8.02 | (b) One 5 Amps socket on Independent board. | 350 | PER POINT | 690 ₹2,41,500 | 750 ₹2,62,500 | 590 ₹2,06,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
16 Jun 2026, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT OF REWIRING OF INTERNAL WIRING FITTINGS FIXTURES AND APPLIANCES OF BLDG UNDER REWA AT MIL STN GANDHINAGAR
2026_MES_768324_1
GE(A)/GNR/TOKEN/50 of 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹85,000
Yes
22 Aug 2026
27 May 2026
18 Jun 2026
27 May 2026
16 Jun 2026
10 Jun 2026
27 May 2026 - 8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed. | 3,140 | PER POINT | - | - |
| 2 | M & L for servicing of ceiling fans/wall mounted 1200/1400mm sweep of any make/model, including removal of existing winding carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation with super enmelled copper number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including complete all as specified and directed. | 1,500 | EACH JOB | - | - |
| 3 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and modular sunken boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One light/fan/bell/exhaust point controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 1,000 | PER POINT | - | - |
| 4 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sunken for boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp same board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 120 | PER POINT | - | - |
| 5 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12& including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp Indepedent board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 350 | PER POINT | - | - |
| 6 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12 & including with multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed for the following :-Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 250 | PER POINT | - | - |
| 7 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multi stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12 & including with multi stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed for the following :-Note: per point lenght of cable should be 7 to 15 mtr . | 80 | PER POINT | - | - |
| 8M&L for drawing of wire RYB for phase,black for neutral,green for earth wire and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade non flamble heavy duty with decorative casing & caping including elbow,tee,junction boxes double lock type 32mm in size,sunken boxes,plate 4,6,8,10,12 modulare plate, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :--Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | |||||
| 8.01 | (a) One light/fan point controlled by one switch | 850 | PER POINT | - | - |
| 8.02 | (b) One 5 Amps socket on Independent board. | 350 | PER POINT | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_860420.xls
BOQ • 0.34 MB
TenderDocuments.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .