| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹33.6 L+₹27,280 (0.82%)Rejected-AOC | L2 | Rejected-AOC R | |
| 3 | L3₹36.0 L+₹2.7 L (7.97%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L3 | Rejected-AOC R | |
| 4 | L4₹36 L+₹2.7 L (8.01%)Rejected-AOC | L4 | Rejected-AOC R | |
| 5 | L5₹37.0 L+₹3.7 L (11.0%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L5 | Rejected-AOC R |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
DAY TO DAY MAINT AND REPAIRS OF ELECTRIC SUPPLY OF OTM AND MD ACCN AT NORTH COMPLEX AT IMA DEHRADUN
2023_MES_606247_1
GE/IMA/T-48 of 2023-2024 9342/E8
Open Tender
Support/Maintenance Service
Item Rate
334 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹80,000
Yes
16 Sept 2023
27 Jun 2023
20 Jul 2023
28 Jun 2023
18 Jul 2023
11 Jul 2023
Amount
M&L for attending all type of electric complaint in the blocks/qtrs/lines/offices in the OTM/Md Accn due to any reason like MCBs/MCCBs burnt out/tripping, leakage fault, short/open circuit faults, electric fittings/fixtures, all type of controls, controls of garden/street lights,controls of summer and cooling appliances i.e Fan , Exhaust Fan , Wall Fan ,Geyser etc.with rectification and restoring the supply by trained person complete all as specified and directed for the South complex OTM/Md Accn Area ( Thimaya Bn, Cariappa Bn, Bhagat Bn, Manekshaw Bn) ,VB Mess , MT colony and Misc area inside the South Complex.
Note: (i) All the T&P items like aluminium folding self supported ladders as per site requirement, drill machines with bits, cutting plier, spanners, Allen key Set, Pipe wrench, Screw driver Sets, Crimping tool,descaling rod, etc will be provided to electricians by the contractor. The cost of T&P shall be inciuded in quoted rates and no extra cost will be paid by department. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen.
All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintained by the contractor.
Stores required for day to day maintenance for all repair work provided by the contractor through this contract. All sundries items like Insulation Tape, Screws, washers, Plastic wall rawal plugs, Nuts, Bolts, dummy plates, thimbles for coper wire etc shall be supplied/ arranged by the contractor without any extra cost to Govt.
All the retrieved material shall be the property of Contractor with Sch of credit as shown on credit schedule.
Contractors are advised to visit the site before quoting rates.
Contractor shall be penalised @ Rs. 200/- per complaint/ day, if he fails to attend and rectify the complaint within 24 hours of lodging the complaint either personally or telephonically. In this regard the decision of the Engr-in-Charge shall be final & binding.
The employed electrician should be qualified with ITI in concerned trade and shall have minimum 03 years experience.
Work shall be carried out as per modern engineering practice and contractor to maintain record register, duty roster, attendance register etc complete alongwith general tool safety measures on conveyance/ transportation uniform etc.
All workers employed by the contractor in day to day maintenance is mendatery to wear proper uniform .
Any stores required for rectification of electric complaints other than item mentioned in CA as provided by the department .
Unit rates also include 2 electrician (SK) each and 2 electrician helper (SSK)each (2+2 x2=8 persons)in two shift with deployed in two places ie South Complex And CR camp Complaint cell for rectification of complaints including sunday & holidays from the date of commencement of work.
Conractor should also provide almirah to electricition employed under the contract to keep their tool bags /stationary etc in safe custody.
Unit rates also include the conveyance and communication facility requried to complete the Job.
S & F in repairs Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt flush to wall including 01 Nos 160 Amps MCCB FP as incomer and 12/24 SP MCBs or 4 / 8 TP MCBs per per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity including taking down old unsv MCCB DB,s complete all as directed. Make :- Havells/ Indo Asian/ HPL
4 Way VTPN DB (FP MCCB +12 MCB,C).
8 WAY VTPN DB TP&N DB(FP MCCB +24 MCB,s)
S & F in repairs MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 18 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity complete all as directed. Make :- Havells/ Indo Asian/ HPL
S & F in repairs MCB,S SP/SPN complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make:- Havells/ Indo Asian/ HPL
MCB SP6 to 32 Amp.240 volts
MCB SP 40 to 63 AMPS 240 volts
MCB SPN 6 to 32 Amps 240 volts
MCB SPN 40 to 63 Amps 240 volts
S & F in repairs MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door Including 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out gooning as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity Make:- Havells/ Indo Asian/ HPL
4 way SPN DB.
8 way SPN DB.
12way SPN DB
16 way SPN DB
S & F repairs sheet metal enclosure, Triple pole and neutral with three pin and earth plug and socket with and including one triple pole MCB 100 Amps, 240 volts,16 KA , including taking down old unsv sheet metal enclosure complete all as directed. Make:- Havells/ Indo Asian/ HPL
S & F in repairs sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps, , complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make:- Havells/ Indo Asian/ HPL
S & F in repairs MCB TP/TPN complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 63A to 100A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable including connection with suitable size copper lugs complete all as directed. Make:- Havells/ Indo Asian/ HPL
MCB TPN 63 Amps, 415 volts
MCB TPN 100 Amps, 415 volts
S&F in repairs fan regulator modular step type 120W 240 volts 2 module type complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
Supply only in repair Modular switch single pole one way 6 Amp complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crab tree)
Supply only Modular switch single pole one way 16 Amp including taking down old unsv switch complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crab tree)
Supply only in repair Modular socket outlet 2/3 pin combined 6 Amp 240 volts including taking down old unsv socket complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crab tree)
Supply only in repair Modular socket outlet 2/3 pin combined 16 Amp 240 volts including taking down old unsv socket complete all as directed.Make: Anchor(Roma), Legrand (Mylinc), Havells (Crab tree)
Supply only in repair Modular bell push flush type, 5 Amps including taking down old unsv bell push complete all as directed. Make: Anchor(Roma), Legrand (Mylinc)
Supply only in repair white modular cover plate with frame including modular metal flush box of following module complete including taking down old unsv modular metal flush box and cover Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
1Module
2Module
3Module
4Module
6Module
8 Module
Supply only in repair Bell AC 230 volts single pole complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
Supply only in repairs ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor,Havells (Crabtree), SSK
Supply only in repairs Electronic steppped type fan regulator 100 watt 230 volts AC 50 Hz complete all as directed. Make: Anchor, Bajaj, Havells
S&F Batten holder including LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output ,including taking down old unsv led bulb PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK Make of bulb : Philips / Eveready /Havells
Supply only in repairs switch piano, flush type, single pole one way 6 Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
Supply only in repairs switch piano, flush type, single pole one way 16Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
Supply only in repairs socket out let, multipurpose, 2 in 1 5 pin, 6 Amp including taking down old unsv socket complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
Supply only in repair socket out let, multipurpose, 2 in 1 5 pin, 16 Amp with fuse and neon indicator complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
S & F in repair 6 Sqmm 2 core 1100 volts grade heavy duty twin flat cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as directed. Make: Anchor, Havells, Polycab.
S & F in repairs flexible cable 3 core 23/0.0076 multi stranded copper conductor white/ black colour code complete all as directed. Make: Anchor, Havells, Polycab.
S & F in repairs single core FR-LSH PVC insulated copper multi stranded conductor cable drawing into existing/new PVC rigid conduit in surface/concealed as required complete of following sizes as directed. Make: Anchor, Havells, Polycab.
Supply and fix in repairs Rigid non metalic PVC conduit of , inclusive of boxes (junction/terminal)but inclusive of all tees,bend ,elbow reducers, bell mouth tube ends and fixing acessories such as couplers,lock,nut saddles,pipe hooks all as specified and directed. Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab
40mm dia
32mm dia
25mm dia
20mm dia
Supply and fix in repairs PVC rectangular block white in colour for mounting Switch,Socket,fan regulator etc. with 3mm thick plastic laminated sheet cover of size s including taking down old unsv rectangular block all as directed.
100mmx100mm and 50mm deep
175mmx100mm and 50mm deep
Supply only in repairs LED Batten light fittings 4 feet / 1200 mm on walls including brackets all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Syatem watt/Lumens: - total system lumen not less than 2850 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 125 lm/watt. (ix) Colour temperature (K): - Not less than 5700 ( COOL DAY LIGHT/WARM WHITE LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 20000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2.5KV (xv) Heat Shink: - As per OEM's design Make:- Philips/ Havells/ Eveready/ Crompton
Supply only LED Batten light fittings 2 Feet on walls including brackets all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Syatem watt/Lumens: - total system lumen not less than 1200 lumen (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700( COOL DAY LIGHT/WARM WHITE LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 20000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2KV (xv) Heat Shink: - As per OEM's design Make: Philips/ Havells/ Eveready/ Crompton
Supply only LED 1 x 1 feet Surface / Recess Mounted (depending upon requirement) light fittings including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: - System lumen not less than 1500 lumen & 1800 lumen. (ii) Housing: - CRCA sheet with powder coating (iii) IP Rating: - IP 20 (v) Mounting: - Surface /Recess Mounted (vi) Finish: - Opal PMMA Diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day white /warm white ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 35000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-27V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2.5 KV (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply only LED 2x2 Recessed/Surface Mounted fittings (depending upon requirement )including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv recess mounted fitting all as conforming to the following parameters: - (i) Lumens: - System lumen not less than 4000 lumen (ii) Housing: - Single Piece CRCA body (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - Ceiling/ Recess Mounted . (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day white ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation @ Ta 35*C (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattarn- Asymmetrical driveway. (xiii) Control gear: - inbuilt electronic driver with 325V Auto Cut off Restart feature, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 3KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply only LED Round/Square Surface/Recess Mounted Downlighter fittings (depending upon requirement )and connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv LED down lighter all as conforming to the following parameters: - (i) Lumens: - System lumen 1500 lumen & 2000 lumen (ii) Housing: - Single Piece body Die cast lluminium (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - On ceiling/Recess Mounted (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lumen/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day White /Warm Light ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation. (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 20% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 2.5KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Crompton/ Eveready
Supply only LED Flood Light fittings with complete fixing arrangemnets and connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv led flood light all as conforming to the following parameters: - (i) Lumens: - System lumen not less than 5000 lm (ii) Housing: - Single Piece Aluminium die cast body (iii) IP Rating & IK Rating: - IP66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - With complete fixing arangement, (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI) & SDCM: - Not less than 70, <5 (xi) Life: - Not less than 50000 Hrs of operation at Ta 45*C (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply only LED Flood Light fittings with complete fixing arrangemnets and connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv led flood light all as conforming to the following parameters: - (i) Lumens: - System lumen not less than 14500 lm (ii) Housing: - Single Piece Aluminium pressure die cast body (iii) IP Rating & IK Rating: - IP66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - With complete fixing arangement, (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI) & SDCM: - Not less than 70, <5 (xi) Life: - Not less than 50000 Hrs of operation at Ta 45*C (xii) Optics: -Diffused/Lens (xiii) Control gear: -Outcutt off @325V, 440V phase 2 phase protection, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV and 10 KV External SPD . (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
M&L for Chemical Earthing Copper Bonded steel earth pipe of 3 metre long having diameter of 80 mm with copper bonding thickness 250 micron , CPRI tested at 25 KA fault current for one second and is provided with universal clamp made of SS Earth Enhancing compound of 50 KG /PIT (Resistivity should be less than 0.12 Ohm meter ) tested as per IEC 62561-7. M&L for Heavy Duty earth cover pit made of poly plastic having Load bearing capacity of 6000 kg. Size of Pit Cover : 270 mm x 240 mm x 200 mm The Electrode should be connected with GI WIRE 4 mm (duly protected by GI pipe of suitable size ) by means of nuts,bolts,check nuts & washers connected to main switch board,including all necessary excavation & earth work in hard dense soill with Backfill compound all around the electrode and necessary testing complete all as shown in drawings attached in tender all as specified and directed Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.
Supply and fix in replacement of ceiling fan complete with blade ,down rod 230 Volts AC ,1200 MM Sweep Min air delivery 210 CFM Five star rated with brushless direct current ( BLDC)motor connected with ceiling rose including fan regulator etc complete all as specified and directed. Make:- Usha/orient/Bajaj/Havells
Supply and fix in replacement of metal body exhaust fan 300 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in replacement of metal body exhaust fan 450 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in replacement of metal body exhaust fan 600 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in repair Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : Crompton/Havells/Bajaj
Supply and fix Water heater (water heater) storage type 25 ltr capacity , five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rust proof metal body, stainless steel inner container, high efficiency heating element, autocut thermostat, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete of following capacity :- . Make: Havells(Adonia Series)/Jaquar/Bajaj
Balraj and Co
M/S S P BUILDERS
Bhanu Prakash
JS CONSTRUCTION COMPANY
KRISHANA ELECTRIC WORKS
M/s Anamika Enterprises
avtarsinghchaddha
Meher enterprises
venus engineers
PRAGATI ENTERPRISES
M R Taders
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .