Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | Admitted-Finance |
| 2 | Admitted-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | Admitted-Finance |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
12 Jan 2023, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur - 342 011 (Raj)
REPAIR/MAINT OF POWER TRANSFORMER AND DISTRIBUTION TRANSFORMER OF DIFFERENT CAPACITY AND HT VCBS AND OTHER CONNECTED ITEMS IN ZONE -B AT DEF LAB JODHPUR
2022_MES_569240_1
8513/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
17 Jan 2023
15 Dec 2022
14 Jan 2023
15 Dec 2022
12 Jan 2023
24 Dec 2022
16 Dec 2022 - 23 Dec 2022
Amount
Dehydration/filtration of transformer oil by means of centrifugal filtration Machine to achieve the specified dielectric strength of 45 to 60 KV at 2.5 mm gap in existing position of transformer of any capacity and transformer oil for topping up at various substation complete all as specified and directed by Engr-in-Charge. (NOTE: (i)Transformer oil used for TOP UP shall be measured and paid separately as supply only. (ii) Contractor has to make his own arrangement for oil filtration machine/ plant. (iii) Filtration shall be done at site when electricity supplies functional.
Disconnecting existing HT/LT connections from transformer of capacity 315 KVA , 1000KVA & 3.15KVA and drain out oil up to working level for replacement of Low tension bushing insulator with stud, nut bolts and gasket etc including opening the transformer and refixing after repairs, including changing cover gasket, checking of winding core and correcting the slackness of core, and tightening nuts, bolts, tightening neutral of the transformer of the transformer from inside refilling in transformer, positioning core properly including testing for insulation resistance etc, and making good connections and testing complete all as specified and directed by Engineer-in-charge. Note: - (i) Item rates deemed to include for proper storage or drained transformer oil and refilling. (ii) The spare parts required for repairs shall be measured and paid separately as supply only (iii) rewinding shall be measured separately.
Supply only transformer oil of approved quality ISI marked for filling in transformer for topping up/ OCB 11 KV complete all as specified and directed by Engineer-in-Charge. Note:- (i) The rates quoted by the contractor deemed to include changing and testing for dielectric strength.
Supply only breather for transformer of suitable size up to 315 KVA transformer complete all as specified and directed by Engineer-in-charge.
Supply only breather for transformer of suitable size for 1000 KVA transformer complete all as specified and directed by Engineer-in-charge.
Supply only breather for transformer of suitable size for 3.15 MVA transformer including taking out unserviceable breather complete all as specified and directed by Engineer-in-charge.
Supply only silica gel for breather of transformer of any type/capacity complete all as specified and directed Engineer-in -Charge.
M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as specified and directed by Engr-in-Charge Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m for protection of earth strip and 32X6 mm GI strip up to 7.50 m length (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Ditto but using copper earth Plate 60cm x 60cm x 3.15mm thick electrode and 20x3mm copper strip as earthing lead complete all as specified and directed by Engineer-in-charge.
Dismantling unserviceable Lightning Arresters with all fittings of any description, complete all as specified and as directed by Engineer-in-charge.
M&L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, 33000V grade complete all as specified and directed by Engr-in-Charge
M&L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, 11000V grade all as specified and directed by engineer in charge.
Dismantling Pin/Disc type insulators with all fittings of any description,Discharge capacity and size, complete all as specified and as directed by Engineer-in-charge.
M&L pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm Height, 150mm dia for 33000 Volt Grade, complete all as specified and as directed by Engineer-in-charge.
M&L Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type white, brown or green, ‘two-in-series assembly’ for tension with tension clamps for conductors, working pressure 33000 Volt, complete all as specified and as directed by Engineer-in-charge.
Dismantling Air Break Gang operated switches,Vertical/Horizontal Mounted including insulators and operating mechanism for repair/replacement of broken/worn out component and insulators or carrying to MES store or credited to contractor, complete all as specified and directed by Engr-in-Charge
M&L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame with Operating Mechanism worked from ground level,current rating upto 200 Amps for 11000V, complete all as specified and as directed by Engineer-in-charge.
M&L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame with Operating Mechanism worked from ground level,current rating upto 400 Amps for 11000V complete all as specified and as directed by Engineer-in-charge.
Repairs GOD and Drop out fuse unit set 9/12 insulator type complete including replacement of all UNSV jumpers, aluminium lugs, nut bolts ,changing of U clips of horizontal/vertical clamps including necessary adjustment complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing HT 33 KV VCBs (Make : ALSTOM) from housing and cleaning, rubbing and servicing the mechanical parts incl , replacement of UNSV Trip coil, Breaker charging motor ,Gear Panion, roller Switch, Big gear etc and re-assembling the same after replacement as required and ,make the VCB serviceable including making all electrical Connection and Testing ( IR Test, Continuity Test, Tripping test of earth fault and Over current of panel ) complete all as specified and directed by Engineer-in-charge. Note:- The Spare parts of VCB panel are measured and paid saperately as supply only.
Supply & fixing Trip coil 300 Volt suitable for 33 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Closed coil 300 Volt suitable for 33 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Electrochemical type relay set of two O/C and one EF for 33 KV, Auxiliary supply 30 Volt DC for VCB panel complete all as specified and directed Engineer-in -Charge.
S&F spring charge motor 230Volts AC for 33KV (ALSTOM VCB) including taking down old unserviceable spring charge motor complete all as specified & directed by Engineer-in-charge.
Supply & Fixing invertor of capacity 1 KVA including taking down old unserviceable invertor of any capacity complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement of unserviceable maintenance free battery 24 V,120 AH initially charged complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing HT 11 KV VCBs from housing and cleaning, rubbing and servicing the mechanical parts incl , replacement of UNSV Trip coil, and re-assembling the same after replacement as required and ,make the VCB serviceable including making all electrical Connection and Testing ( IR Test, Continuity Test, Tripping test of earth fault and Over current of panel ) complete all as specified and directed by Engineer-in-charge. Note:- The Spare parts of VCB panel are measured and paid saperately as supply only.
Supply & Fxing Trip coil 110 Volt suitable for 11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Closed coil 110 Volt suitable for 11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Configureing TNC switch compatiable for 11KV VCB panel 10 Amps 440 volts including taking down old unserviceable complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Configuring remote switch compatible for 11KV VCB panle 32 Amps 440 Volts including taking down old unserviceable, complete all as specified and directed Engineer-in -Charge.
Supply & fixing Solid state relay IMDT type (02 O/C +01 EF) for 11 KV VCB panel,rating 5 Amps,Auxilliary supply 30 Volt DC complete all as specified and directed Engineer-in -Charge.
Repairing & testing of 33KV breaker mechanically type, 400 Amps, 36 KV, 3 phase, 50 Hz with shunt trip coil 110-volt DC volt 110 motor single phase 230 volt with replacement of burnt items and testing complete all as specified and directed by Engineer-in Charge.
Supply & fixing Auxillary relay of 110 volt DC complete all as specified and directed Engineer-in -Charge.
Supply & fixing Master Trip relay of 110 volt DC complete all as specified and directed Engineer-in -Charge.
Supply & fixing Annunciator 12 window of 110 volt DC complete all as specified and directed Engineer-in -Charge.
Supply & fixing Hooter of 110 volt DC complete all as specified and directed Engineer-in -Charge.
Supply and fixing of WTI & OTI Meter suitable for 3.15 MVA Transformer complete all as directed by Engineer-in-charge.
Supply, installed, commissioning and testing of indoor type HT/LT panel board of size not less than 600x600x200 mm, outdoor/indoor cubical type KIOSK factory made (CPRI approved) single/double door type locking arrangement, main panel board fabricated out of CRCA MS sheet 3.15 mm thick etc complete all as specified and directed by Engr-in-Charge
Dismantling of old control wiring of panel and replace with new control wiring with suitable items required at site by an Engineer having knowledge of 33/11 KV line etc complete all as specified and directed by Engr-in-Charge
Supply & fixing Buchhoz Relay for 3.15 MVA Transformer complete all as specified and directed Engineer-in -Charge.
Supply & fixing Control cable of 10 core, 2.5 sqmm. complete all as specified and directed Engineer-in -Charge.
Supply and fix in replacement of unserviceable PT complete Box Type- 005, 3 Phase, sta/star connection of 11 KV/110 volt all as per existing make complete all as specified and directed by Engineer-in charge.
Anil Builders
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .