Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | ₹26.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹27.5 L+₹1.4 L (5.40%)Rejected-Finance | ₹27.5 L+₹1.4 L (5.40%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 4 | Rejected-Technical | - | - | Rejected-Technical L3 |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹28.8 L
EMD Value
₹50,000
Closing Date
22 Sept 2020, 3:00 pmClosed
AEE
Municipal office , Tripunithura
Construction of Municipal Mall at Thripunithura Municipality_Installation of RMU AND USS.
2020_LSGD_383904_1
PW1-6243/20
Open Tender
Electrical Works
Item Rate
90 days
TRIPUNITHURA
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,500
Yes
online
₹50,000
Yes
4 Dec 2020
11 Sept 2020
25 Sept 2020
11 Sept 2020
22 Sept 2020
11 Sept 2020
Amount
Supply and installation of CCT2 type Outdoor RMU Unit , 2 Isolator+1 Breaker, both sides extensible with Battery & Battery Charger, motorized SCADA compatible outdoor front cable entry with additional canopy CT for metering in C limb 1 No SF6 insulated arc quenching load break switch with SF 6 breaker suitable for 11KV/433V Transformer. Unit shall be with terminal protectors protection relays with all materials complete conforming to relevant IS/ IEC standards. The work should be carried out as per the directions of the KSEB authorities. Make-Schneider/ Equivalent make suggested by KSEB authorities.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 2 core 4 sq mm
Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. 4 sq mm
Supply of superior quality aluminium reducer (banana) cable socket and making core termination of cables of the following sizes including crimping etc. as required. 4 sq mm
Supply and fixing Emergency Push Button with MS Box and giving connection etc as required.
Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.
Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.
Supplying and installation of supports, anchor bolts etc made out of suitable size single section MS angle, flats etc as required including painting with 2 coats of synthetic enamel paint
Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required. 450 x 450 x 10 mm cast iron gully trap with covering
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required. 300 x 300 x 6 mm cast iron gully trap with covering.
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm tinned copper strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 x 3 mm copper strip tinned at the points of contacts
Supply and laying strips of the following sizes along with wiring/ cables and giving connection as required. 25 x 3 mm copper strip tinned at the points of contacts
Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). 25 x 3 mm copper strip tinned at the points of contacts
Supplying , threading , laying and jointing of the following sizes of 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. 32mm
Earth work excavation in ordinary soil and depositing with a lead up to 50 m and lift up to 1.50 m including neat banking
Brick work in cement mortar 1:6 with country burnt bricks 19cm x 9cm x 9cm for foundation and basement.
Plastering with cement mortar 1:4, 12mm thick one coat.
Cement concrete 1:2:4 using 20mm (nominal size) broken stone for reinforced concrete work.
Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel
Form work for reinforced cement concrete in slabs including wooden planks, joists, bamboo posts and labour for taking down after completion of work (Hire and labour charges only)
Colour washing, two coats
Supply conveyance installation testing and commissioning of 400 kVA indoor type unitised sub station comprising of H.T panel trunked with cast resin Transformer with load break switch/ Air break switch on H.T.side and manualy operated, with top/bottom entry cable box, 630A, 4 pole 50kA M.C.C.B on L.T. side as per technical details furnished below. H.T Portion consists of (1) 1 No 11K.V, 630A, 26.3 K.A air break/Load break switch suitable for 3 phase 3wire 50 Hz system with suitable H.R.C. fuses of appropriate rating with earth inter lock with main switch and mechanical ON/OFF indication (2)shunt trip coil for the remote operation of the the load break switch. Transformer Portion: 400 K.V.A , 11 K.V, 50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrossion by epoxy resin finish.Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achive tap position of 2.5% x 4. Temperature scaner with trip annunciator shall be provided. The transformer shall confirm to IEC 726 and IS 11171/1985 reaffirmed in IS2026/ 1991, complying to ECBC as per rules. L.T.Portion The LT portion shall be provided with 1No 4Pole 630A 50KA isolation duty type MCCB(Ics=100%Icu) with microprocessor based release with setting range 80-100% with shunt release including suitable range neutral CT and over current & earth fault relay. All inter connection from HT load break switch to transformer and to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclousure shall comply to IP 54 standards and shall be powder coated over suitable primer after seven tank processing and phosphating. The USS shall be installed as per the directions of site in charge.
TOD Metering Facitiies (a) */5A (Suggested by K.S.E.B) 15VA, 0.2S Class accuracy Cast resin C.Ts-3 Nos (b) 3Phase 3Limb 11KV/110V, 10VA, 0.2S Class accuracy Cast resin P.T with protective fuses-1 No (c ) 1No TOD meter, 3 Ph 4 Wire, 0.2S Class accuracy both for active and reractive power-1 No (d) 1No TOD meter test terminal block-1 No (TOD meter and CTs, PTs unit compartment shall be so fabricated. So as to enable the K.S.E.B authorites to seal it).
3 phase 4 wire TVM 240 V, 5A with BM RS 485 port of class 0.5s.
400/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
Supply & laying of one number 11 KV grade XLPE cable of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. - 3 core 300 sq mm
Supply & laying of one No. 11 KV grade XLPE cable of the following sizes in the existing masonry open duct as required. - 3 core 300 sq mm
Supply, laying and clamping ogf 1 no. 11 KV grade XLPE cable of the following sizes using clamps fabricated from 20x3 mm MS flat, spacing of clamps not exceeding 60cm, making good the damages, colour washing etc., as required. - 3 core 300 sq mm
Supplying and making indoor end termination with push-on end termination kit (earthed) for 11 KV grade XLPE cable of the following sizes including supply of end sealing kit consisting of stress-cum-semi conducting pad, sliding core, self bonding insulating tape, boot (with 3 core kit), earth continuity connection (with 3 core kit), earthling lug (with 1 core kit), adhesive-cum-solvent, PVC (NA) tape, silicon grease, aluminium crimping lug, aluminium oxide cloth, nylon string, copper binding wire, hose clamp and bi-metallic washer etc. as required.
Supplying , laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground including excavation of trench to a depth of 120 cm and refilling the trench with the excavated soil etc as required (in ordinary soil) - 175 / 147 mm or nearest size
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 400 sq mm with factory made clamp
Supplying siemens / tropodur type nickel plated Single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required 3.5/ 4 x 400 sq mm
Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 25 x 6 mm for earthing glands of size 400 sq mm to 630 sq mm
Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 400 sq mm
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height
Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
Supply and providing 2.5mm thick synthetic VC fire retardent insulating sheet to withstand 3.3 KV dielectric strength conforming to IS
Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Prepration of completion report, arranging inspection and otaining energisation / sfaety certificate for Ring Main Unit from Depty Chief Electrical Inspector Eranakulam excluding statutory and other charges.
Charges for preparation of Electrical Schematic per A3 sheet first copy
Copying charges for additional copies per A3 sheet
KAY BEE TECH ENGINEERS AND CONTRACTORS PRIVATE LIMITED
Kittu Electricals private limited
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_545733.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .