Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | ₹18.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹18.3 L+₹19,466.50 (1.07%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹18.3 L+₹19,466.50 (1.07%) | L2 | Rejected-Finance L2 |
| 3 | L3₹18.9 L+₹77,697 (4.29%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹18.9 L+₹77,697 (4.29%) | L3 | Rejected-Finance L3 |
| 4 | L4₹20.0 L+₹1.8 L (10.2%)Rejected-Finance | ₹20.0 L+₹1.8 L (10.2%) | L4 | Rejected-Finance L4 |
| 5 | L5₹20 L+₹1.9 L (10.4%)Rejected-Finance | ₹20 L+₹1.9 L (10.4%) | L5 | Rejected-Finance L5 |
Tender Value
₹22.7 L
EMD Value
₹45,400
Closing Date
10 Aug 2020, 6:00 pmClosed
Lt Col Amit Bhat
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
PROVISION OF UG CABLE WITH MCCB FOR ARRESTER BARRIER AT RUNWAY CONTROLLER HUTS AT AF STN JAMNAGAR
2020_MES_346744_2
8727/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹45,400
Yes
17 Sept 2020
20 Jul 2020
11 Aug 2020
20 Jul 2020
10 Aug 2020
20 Jul 2020
Amount
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core.
Supply and lay cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor of size 120 sqmm 3.5 core. complete all as specified and directed by Engg –in-charge.
Supply and lay cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor of size 185 sqmm 3.5 core. complete all as specified and directed by Engg –in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, / laying of pipe / cable etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete complete all as specified and directed by Engg –in-charge.
Excavation in Trenches not exceeding 1.5 m wide and not exceeding 1.5mtr in depth for foundation. (Laying of under ground cables and PCC pole) in Hard/dense soil and getting out complete all as specified and directed by Engg –in-charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as specified and directed by Engg –in-charge.
Removing excavated soil to distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engg –in-charge.
M & L for sand filling in trenches for cable cushioning with clean dry fine sand, including gently punning around cable complete all as specified and directed by Engg –in-charge. NOTE : Punned thickness of sand will be measured and paid.
Supplying & laying factory made unreinforced precast cable cover LV type 1 flat of size 250 x150 x 40 mm complete all as specified and directed by Engg –in-charge.
M&L for 100 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground cable when crossing the road complete all as specified and directed by Engg –in-charge. Make: TATA/JINDAL/SURYA PRAKASH/SWASTIK
S&F Sheet metal enclosure (CRCA sheet) dust and vermin proof ,fixed with MCCB 160 Amps, 25 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed by Engg –in-charge.
S&F Sheet metal enclosure (CRCA sheet) dust and vermin proof ,fixed with MCCB 200 Amps, 25 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed by Engg –in-charge.
Cleaning of runway duct of any size from one end to another end of runway (Duct length approximate 40 to 50 mtrs) complete all as specified and directed by Engg –in-charge.
Cleaning of runway duct of any size from one end to another end of runway (Duct length approximate 30 to 40 mtrs) complete all as specified and directed by Engg –in-charge.
M&L for Boring under roads/pavement/hard standing without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and directed by Engg –in-charge.
Note :- Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost.
M&F for Earthing complete with galvanized steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth strip 32x6 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed.......
.......including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion complete all as specified and directed by Engg –in-charge.
Supply & Fixing Wall mounted fan 230 Volts, Single Phase oscillating 400mm sweep .
M & L for Switch socket combination white polycarbonate body, 6A 230 V, Multipurpose, indicator based including connecting complete all as specified and as directed Eng-in-Charge.
Material & Labour for point wiring concealed for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC casing capping not less than 25 mm, including all accessories like corner, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC board on wall complete all as specified and as directed Eng-in-Charge.
All as per item No 18 here-in-before but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M&L Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete all as specified and as directed Eng-in-Charge.
M & L for Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete all as specified and as directed Eng-in-Charge.
Supply and fix stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and as directed Eng-in-Charge.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
M&L for Ceiling rose ceiling rose , 3 phase white polycarbonate body 6 Amps, 250 volts AC, including connecting complete all as specified and as directed Eng-in-Charge.
Supply & Fixing ceiling fan 230 Volts, Single Phase 1200mm sweep alongwith canopy and fasterner bolts for hanging completely as directed by Engr-in-Charge.
S&F earth continuity conductor or main earthing strip of Copper strip of size 20 x 3.15 mm complete fixed to wall / ceiling in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engg -in - Charge
Material and labour for installation, testing and commissioning of earthing using following material including necessary T&P required to complete job for earthing excavation etc for Make:- Powertrac Model No-PT-803 or equivalent of make PRAGATI / McML’s Earthing Solution (MES) / Ashlock
(a) 'CHEMO' M.F. Earthing Electrode, (confirming to IS 3043:1987), of Copper, 3.00 metre long, 80 mm outer dia, Copper inner strip of size 50 x 6 mm thick, pipe filled with SRIP Compound (50 kg per earthing electrode) (b)FRP based earthing display board with support stand FRP Coated width-254mm, length-380mm, height-610mm (c) FRP Earthing chamber cover ,earthing pit, MOC-FRP,
...for chamber of internal size 300 mm x 300 x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), funnel, with wire mesh, complete all as specified and directed. Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Note:- (i)Earth work in any type of soil, Installation of complete earthing system will be carried out by company's authorized Tradesmen / representative (ii) Item Rate quoted by contractor shall include for 250 mm dia bore up to 3 metre deep by a spilling machine or bore well machine, mixing of SRIP compound with soil.
S & F Air termination, single pointed, copper rod 12mm dia and 300mm long
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm......
.....bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Material and labour for installation, testing and commissioning of earthing using following material including necessary T&P required to complete job for earthing, excavation etc.
Make:- Powertrac Model No-PT-803 or equivalent of make PRAGATI/ McML's Earthing Solution (MES)/ Ashlock (a) 'CHEMO' M.F. Earthing Electrode (conforming to IS 3043:1987) of copper, 3.00 metre long, 80 mm outer dia, copper inner strip of size 50 x 6 mm thick, pipe filled with SRIP compound (50 kg per earthing electrode) (b) FRP based earthing display board with support stand FRP coated width-254 mm, length-380mm, height-610 mm
(c) PCC earthing protection chamber for each earthing pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/sqm)
Note:- (i) Earthwork in any type of soil, installation of complete earthing system will be carried out in presence of company's authorised tradesmen/ representative. (ii) Item rate quoted by contractor shall include for 250 mm dia bore upto 3 metre deep and pouring, mixing of SRIP compound with soil. (iii) Drawing for single bore earthing is enclosed.
(d) The earthing result will be obtained for each electrode must be less than 3Ω. Otherwise contractor is liable to do chemical earthing to meet the result without extra cost if the results are above 3Ω. (e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work.
(f) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical earthing. (g) Extension strip from electrode strip upto 0.15 m height from GL to be deemed included in quoted rate including brazing (h) The contractor has to give in writing for 3 years minimum warranty for constant result of earth below 1Ω.
S&F Air termination, pointed Aluminium rod 12 mm dia and 300 mm long with Aluminium Air Rod fixed in position as support of aluminium strip network & PCC concrete block of size 15 cmx15cmx15 cm on roof complete with clamp and nut bolts all as specified and directed
S&F earth continuity conductor or main earthing strip of Copper strip of size 20 x 5 mm complete fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engg -in - Charge
Supply and fixing Aluminium earth strip of size 25 x 3.15 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminals all as directed by Engr-in-charge
Supply and fix GI strip 32mm x 6mm buried in ground
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size of 75 mm x 75 mm x 25 mm drilled and screwed fixing in FRP box complete all as specified and as directed.
Supply and fixing GI tubing of size 40 mm bore light grade ISI marked laid in trenches / on floor ceiling etc including with all fitting such as elbow, union reducer tees bends etc and short length for cable protection including taking down old GI tubing complete all as specified and directed by Engr -in -charge
Supply and fix PCC block of size 15cm x15cm x15cm suitable for copper strips including fixing with suitable size of screw and insulators all as specified and directed by engineer-in-Charge.
Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed by Engg –in-charge.
Supply and fix Flame proof rotary switch ( Isolator ) rating 16 Amps. Single pole ON /OFF in alluminium alloy LM 6 Construction with one/ 2 nos, 3/4 " ET entries, certified by CMRS , Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engg –in-charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engg –in-charge. Note- 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Supply & fix flame proof Ceiling Fan 1200mm in aluminium alloy LM 6 construction, certified by CMRS Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engg –in-charge. Make :- Sudhir or equivalent.
Supply anf fixing Flame Proof fan regulators in aluminium alloy LM 6 construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engg –in-charge. Make :- Sudhir or equivalent.
Supply & Fix Flame Proof LED tube light fitting 1 x 20 watt with built in electronic driver in aluminium alloy LM 79 construction , CMRI certified recommended for Gas/vapor group of IIA & II B & zone 1 with all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete complete all as specified and directed by Engg –in-charge. Make:- Crompton cat No EXTN1LT8-16/20 or equivalent of make Sudhir/C&S/Baliga.
jagdish machinery stores
SURESH ELECTRICALS
rajengineers
ambika electric co
JAMNAGAR ELECTRIC AND MACHINERY CO
M/s super construction
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .