Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹9.9 L+₹2.6 L (36.3%)Rejected-Finance | L2 | Rejected-Finance DUE TO L2 | |
| 3 | L3₹10.0 L+₹2.7 L (37.0%)Rejected-Finance 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | L3 | Rejected-Finance DUE TO L3 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 Oct 2023, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINTENANCE AND REPAIRS / RENEWAL OF DISTRIBUTION BOARDS, LT SWITCH GEAR ALONG WITH CONNECTED ITEMS UNDER GE (AF) BIDAR
2023_MES_618187_1
8250/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹30,000
Yes
20 Jan 2024
11 Sept 2023
10 Oct 2023
11 Sept 2023
9 Oct 2023
26 Sept 2023
Amount
Sub main wiring / power wiring complete with two runs of 4 Sqmm, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface of wall /floors / roof with one run of PVC insulated, 4 Sqmm FRLS copper conductor for earth continuity including taking down existing unserviceable sub main wiring with conduitcomplete all as specified and as directed.
All as per item No 1.00 here in before but with 2 runs of 6 Sqmm for phase and neutral and 1 run of 6 Sqmm for earth wire complete all as specified and as directed.
All as per item No 1.00 here in above but with 2 runs of 10 Sqmm for phase and neutral and 1 run of 10 Sqmm for earth wire complete all as specified and as directed. NOTE FOR ITEM NO. 1, 2 AND 3: Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Sub main wiring, complete with 4 runs of 6 sqmm, PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/ wall/ roof etc. with two runs of PVC insulated, 6 sqmm FRLS cable, copper conductor for earth continuity conductor including taking down existing unserviceable sub main wiring with conduitcomplete all as specified and as directed.
Sub main wiring, complete with 4 runs of 10 sqmm, PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/ wall/ roof etc. with two runs of PVC insulated, 10 sqmm FRLS cable, copper conductor for earth continuity conductor complete all as specified and as directed. NOTE FOR ITEM NOS 4 AND 5: Four runs of main copper conductor, two runs of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
S&F in repair MCB DB SPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB SPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB SPN 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB DB TPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCCBs including connecting etc., complete all as specified and as directed.
S&F in repair MCB SP 6-32 Amps complete all as specified and directed.
S&F in repair MCB SPN 32 Amps complete all as specified and directed.
S&F in repair MCB SPN 63 Amps complete all as specified and directed.
S&F in repair MCB TPN 32 Amps complete all as specified and directed.
S&F in repair MCB TPN 63 Amps complete all as specified and directed.
S&F in repair MCB TPN 100 Amps complete all as specified and directed.
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Disconnection and removing the u/s Industrial plug and socket unit and S&F Industrial plug and socket enclosure 32 Amp 3P+N+E, 4 module complete all as specified and as directed.
Disconnection and removing the u/s Industrial plug and socket unit and S&F Industrial plug and socket enclosure 63 Amp 3P+N+E, 4 module complete all as specified and as directed.
Disconnection and removing the u/s MCCB enclosure and S&F MCCB enclosure with solid neutral link for 3 pole MCCB complete all as specified and as directed.
Disconnection and removing the u/s on load change over switch and S&F on load change over switch 4 pole, 415V,200 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the u/s on load change over switch and S&F on load change over switch 4 pole, 415V,100 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the u/s off load change over switch and S&F off load change over switch with enclosure 4 pole, 415V,400 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the u/s off load change over switch and S&F off load change over switch with enclosure 4 pole, 415V,200 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the u/s off load change over switch and S&F off load change over switch with enclosure 4 pole, 415V,100 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the u/s off load change over switch and S&F off load change over switch with enclosure 4 pole, 415V,63 A, 50 Hz complete all as specified and as directed.
Disconnection and removing the unserveciable MCCB and S&F new MCCB with thermalmagnetic release Conform to IS/IEC 60947-2 & IEC 60947-2 4 pole, 415 V, 400 A, 50 Hz, breaking capacity of 36 KA complete all as specified and as directed.
All as per item No 31.00 here in before but of capacity 250 A, 36 KA
All as per item No 31.00 here in before but of capacity 200 A, 25 KA
All as per item No 31.00 here in before but of capacity 100 A, 16 KA
All as per item No 31.00 here in before but of capacity 63 A, 16 KA
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out /for laying under ground cables/ pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note: Only punned thickness will be measured and paid.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cms thick complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
Unreinforced precast concrete cable cover class LV, Type I, flat, of size 250 mm x 150 mm x 40 mm for cable protection complete all as specified and as directed.
Relaying of old serviceable PCC cable cover class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection complete all as specified and as directed.
Taking down of LT XLPE/ PVC UG cable 1100 V grade including joints where required of various size from the trenches for finding out the fault complete all as specified and as directed.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified and as directed.
All as per item No 43.00 here in before but of size 35 Sqmm 3.5 core
All as per item No 43.00 here in before but of size 25 Sqmm 4.0 core
All as per item No 43.00 here in before but of size 16 Sqmm 4.0 core
Disconnection and removing the unserveciable twin core service wire and S&F twin core Aluminium service wire of size 4 Sqmm unsheathed 1100 Volts grade complete with necessary fixing arrangements complete all as specified and as directed.
All as per item No 47.00 here in before but of size 6 Sqmm
Satish Patpally
famous construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .