Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC L1- Bidder | |
| 2 | L2₹37.6 L+₹85,875.80 (2.34%)Rejected-Finance 19 PAOTA C IIIRD ROAD JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹39.5 L+₹2.8 L (7.49%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹48.3 L+₹11.5 L (31.3%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | Om Trading Corporation L2 | M/S KAUTILYA GARG L3 | M/S SUMAN ENTERPRISES L4 | mahalaxmi enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling existing tanks of any description exc 500 n.exc 1000 ltrs capacity and removing from site complete all as specified & directed. | 10 | Each | 150 ₹1,500 | 100 ₹1,000 Lowest | 500 ₹5,000 | 100 ₹1,000 Lowest |
| 2.00 | S&F for 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl fixing arrangment for inlet/outlet/overflow & vent pipe of standard size complete all as specified & directed. | 10 | Each | 8,250 ₹82,500 | 6,000 ₹60,000 Lowest | 9,000 ₹90,000 | 7,500 ₹75,000 |
| 3.00 | Supply only 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & 3, plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) all as specified & directed. (Fixing included in Item No 3 & 4 above) | 16 | Each | 350 ₹5,600 | 200 ₹3,200 Lowest | 400 ₹6,400 | 200 ₹3,200 Lowest |
| 4.00 | Disconnecting of existing Exc 500 ltr n.exc 1000 ltr capacity existing tanks, seting aside (or lowering if required) for repair, cleaning etc. and hoisting and reconnecting and refixing in position for complete all as specified and as directed. | 6 | Each | 500 ₹3,000 | 200 ₹1,200 Lowest | 1,000 ₹6,000 | 500 ₹3,000 |
| 5.00 | S &F in repair 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron
pipe and fixed both ends for iron pipe or for union complete all as specified & directed. | 10 | Each | 650 ₹6,500 | 600 ₹6,000 Lowest | 1,000 ₹10,000 | 650 ₹6,500 |
| 6.00 | All as per item No. 5.00 here-in-above but in 20 mm bore pipe | 10 | Each | 450 ₹4,500 Lowest | 550 ₹5,500 | 1,000 ₹10,000 | 550 ₹5,500 |
| 7.00 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or remove to store or credited to contractor for 15 mm bore pipe complete all as specified and directed. | 50 | RM | 25 ₹1,250 | 10 ₹500 Lowest | 30 ₹1,500 | 10 ₹500 Lowest |
| 8.00 | All as per item No. 7.00 here-in-above but here in 20 mm bore pipe | 100 | RM | 15 ₹1,500 | 10 ₹1,000 Lowest | 30 ₹3,000 | 10 ₹1,000 Lowest |
| 9.00 | All as per item No. 7.00 here-in-above but here in 25 mm bore pipe | 80 | RM | 50 ₹4,000 | 10 ₹800 Lowest | 30 ₹2,400 | 10 ₹800 Lowest |
| 10.00 | Supply, fixing, testing & commissioning of 15mm bore GI steel water tubing, medium grade, ISI marked, galvanised including short lengths, fixed to walls / pillars with MS clamps is or position in Walls, ceiling, floors complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) of following sizes bore of GI pipe, complete all as specified and directed"- | 50 | RM | 180 ₹9,000 | 180 ₹9,000 | 250 ₹12,500 | 160 ₹8,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹87,800
Closing Date
8 Sept 2025, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
SPECIAL REPAIR OF ROOF TREATMENT TO BLDG No 1251 (ORs LINE) OF CSR AND PROVN OF WALL AND FLLOR TILING INCLUDING ASSOCIATED WORKS IN BLDG No P-218/1 UNDER THE AREA OF AGE B/R-I OF GE (A) No 1 JODHPUR
2025_MES_725621_1
GE/JODH (A) NO 1- OF 2025-26 (9353/E8)
Open Tender
Civil Works
Item Rate
180 days
Jodhpur
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (A) No 1
₹87,800
Yes
16 Oct 2025
11 Aug 2025
15 Sept 2025
11 Aug 2025
8 Sept 2025
25 Aug 2025
Amount
Dismantling existing tanks of any description exc 500 n.exc 1000 ltrs capacity and removing from site complete all as specified & directed.
S&F for 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl fixing arrangment for inlet/outlet/overflow & vent pipe of standard size complete all as specified & directed.
Supply only 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & 3, plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) all as specified & directed. (Fixing included in Item No 3 & 4 above)
Disconnecting of existing Exc 500 ltr n.exc 1000 ltr capacity existing tanks, seting aside (or lowering if required) for repair, cleaning etc. and hoisting and reconnecting and refixing in position for complete all as specified and as directed.
S &F in repair 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed both ends for iron pipe or for union complete all as specified & directed.
All as per item No. 5.00 here-in-above but in 20 mm bore pipe
Taking up or down steel water tubing and connections, including cleaning for re-fixing or remove to store or credited to contractor for 15 mm bore pipe complete all as specified and directed.
All as per item No. 7.00 here-in-above but here in 20 mm bore pipe
All as per item No. 7.00 here-in-above but here in 25 mm bore pipe
Supply, fixing, testing & commissioning of 15mm bore GI steel water tubing, medium grade, ISI marked, galvanised including short lengths, fixed to walls / pillars with MS clamps is or position in Walls, ceiling, floors complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) of following sizes bore of GI pipe, complete all as specified and directed"-
All as per item No. 10.00 here-in-above but here in 20 mm bore pipe
All as per item No. 10.00 here-in-above but here in 25 mm bore pipe
Refixing 20mm bore old steel tubing and connections in new or old position in Walls, ceiling, floors, etc complete all as specified and directed.
All as per item No. 13.00 here-in-above but here in 25 mm bore pipe complete all as specified and directed.
Taking down existing damaged /loosed cement concrete /stone patti from roof /terrace to a depth of average 50 mm including taking down of existing app membrane if any cleaning with water and depositng of debris outside MoD land height of Bldg upto 4th story complete all as specified & directed.
M&L for PCC 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof pedding including weathering, slightly rounded or chamfered angles and finished surface even and smooth height of Bldg upto 4th story complete all as specified and as directed.
M& L for roof treatment in the following stages :-(Height of Bldg upto 4th storey) (a) first Course : M&L for 15 mm thick plaster with CM 1:3 mixed surface even and smooth with water proofing compound as per manufacturer instructions (Note: - WPC shall be measured and paid separately). (b) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied water proofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. Note : - 1. The authorized applicator of manufacturer shall be approved by GE.
M&L for 30 mm thick guniting in patches on to the required area on RCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at any heights from existing ground floor and at any locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete as specified here in before and applying one coat of rust convertor/kp-100 equivalent grade over reinforcement wherever necessary providing and tying in position 25mmx25mmx12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc,loose spalt concrete portions by chipping, removal of dust over treated surface and applying 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, and removing the debris out side the MOD land in low lying areas and leveling complete all as specified & as directed.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & as directed.
M&L for cutting in to old masonry to form toothings for bonding in new brick or stone work including making good in cement mortar 1:6 complete all as specified and directed.
M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complate all as specified and directed.
All as per item No 21 above but except stone complate all as specified and directed.
M&L PCC solid building blocks 10 cm thick type B1 1:2:4 set in cement mortar (1:6) complete all as specified and directed.
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete to squared rubble walling, regular coursed, Jodhpur typeall as specified and directed.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L Rendering 10 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of concrete or stone wall surfaces finished even and smooth without extra cement complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of concrete or stone wall surfaces finished even and smooth without extra cement complete all as specified & directed.
Supply only Integral water proofing compund (ISI marked) complete all as specified and directed
Racking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar complete all as specified and directed
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 complete all as specified and directed
Taking down carefully cement concrete/ spalled out concrete from RCC roof projections, Ceilings, Sunshades, beams etc upto cover depth by chipping out lightly including necessary scaffolding etc for complete all as specified and as directed.
M&L for cleaning the existing reinf of slabs chajjas etc & applying a coat of SIKA RUSTOFF 11 or equivalent of pidilite,fosroc,Thermax etc to remove rust particles etc throughly cleaning the surface including necessary scaffolding height of Bldg upto 4th storey complete all as specified & as directed.
M&L for applying a coat of bond coat made with cement slurry (1part cement to 1.5-2 parts water) mixed with admixture LATEX POWER of SIKKA or equivalent to fosroc 'Asian Paint' mixed @ 5 Kg per 50kg of cement & applying to the concrete surfaces @200gm/sqm to obtain tackincluding necessary scaffolding height of Bldg upto 4th story complete all as specified & as directed.
M&L for 15-20mm thick rendering in CM 1:1:2 using 1 part cement to 1part 2-3mm screenings of stone aggregate & 2 parts coarse sand over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE admixture or equivalent of pidilite, fosroc, Thermax etc @100gm/50kg of cement & finishing the surfaces even & rough to recieve final rendering coat including necessary scaffolding height of Bldg upto 4th story complete all as specified & as directed.
M&L for 10-15mm thick rendering in CM 1:3 over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE SUPER or equivalant admixture @100gm/50kg of cement & finishing the surfaces even & smooth, including over the surface of GI chicken wire mesh of 0.71mm dia wire & 12mm mesh size fixed with nails & screws around RCC chajjas/fascias etc including necessary scaffolding height of Bldg upto 4th story complete all as specified and directed.
Demolition of reinforced cement concrete of any description for roof,colums, beam of any type etc complete all as specified and directed.
M & L RCC design mix M-25 using 20 mm graded stone aggregate as in slab supported on wall, roof slab, Chajja and in shelve etc complete all as specified and directed.
M & L RCC nominal Mix-25 using 20 mm graded stone aggregate as in beam, roof beam, cantilevers, lintel beam, etc. complete all as specified and directed.
S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F mild steel TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
Use and waste of formwork to sides and soffits of slabs n. exc. 200 mm thick and similar works fair finished surfaces of concrete complete all as specified and directed.
Use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of fair finished surfaces complete all as specified and directed
From work to edge of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide with fair finished surfaces complere all as specified and directed.
S&F for Mild steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for ledders; fixed with angle cleats or other connecting platesbracket framing including distance pieces, cleats etc Fe-410-W(Gde-E-250) quality complete all as specified
Dismantling of steel work including doors, gate railing stair case ladder, steel post, chain link fencing fixed with post and barbed wire etc complete all as specified and directed.
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and directed
M&L for applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
M & L three coats of white wash on newly plastered surface of ceiling including preparation of serfaces complete all as specified and directed.
M&L preperartion of newly plastered surfaces on wall and applying 1.5 - 2 mm of wall putty with fair finished and even surface and applying two coat of oil bound distemper over a coat of primer complete all as specified & directed.
M&L for complete removal of existing distempered surfaces of walls and applying two coats of oil emulsion distemper of white shade or other approved shade over two coat of white putty on plastered surface all as specified and directed.
M&L for applying one coat of cement base paint on old surfaces including preparation complete all as specified & directed.
M & L two coats of cement based paint on newly plastered/ unplastered surface of wall including preparation and one coat of chalk white of surfaces complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.
M&L for 25mm thick cement concrete type B-0 1:2:4 as in sub base of floor tiles (using 12.5 mm graded crushed stone aggregate) complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished double charged, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Ditto all as per Item No 56.00 above but herein skirting/dado including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed colour ceramic tiles of size 300x450x7/ 300x600x 7mm thick, laid in vertical surface dado/skirting joint free etc, set and jointed in neat cement slurry and pointed in coloured tiles to match the shade of tiles including 10mm thick rendering in CM 1:4 over stone masonary surfaces finished even & rough to receive tiling complete.
Taking down shutter of any description, exc.1 Sqm but n exc 2 Sqm each and refixing in the other opening incl necessary hinges complete all as specified and directed.
S&F ONE PEICE vitreous china wash down EWC with and including inbuilt flush tank with seat cover Fixing Accessories etc complete all as specified and as directed.
S&F fancy type vitreous WHB oval type fixed to granite of bracket or erecting stand with waste pipe complete all as specified and directed.
S&F 15mm bore CP central hole basin mixture popum waste system with 450 mm long copper pipe and brass nuts ISI Marked sitable for over head counter WHB complete all as spd and directed.
S&F CP brass Wall mixture 3-in-1 system fancy type, cast copper alloy,with capstan heads,chromium plated,screwed down high pressure 15mm bore, Hot or Cold with with or without legs,screwed for iron pipe fixed
S&F Brass chromium plated over head shower rose 150x150mm size square with shower arm including fixing to steel pipe or union in repairs
S&F Bidet spray (Health faucet) with 1 meter PVC tube and holder, completed. Make- Jaquar and Equivalent
S&F 15 mm bore CP brass two way angular stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe fixed in repair.
S&F 15 mm bore single lever swan neck sink mixer, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
M&L 20 mm thick machine cut one side polished black granite on WHB,kitchen plate form and windows cill, set and jointed including 20 mm thick screed bed in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including moulding to 20mm thick rubbing, machine polishing to edge complete all as specified and directed.
S&F corner glass shelf assembly consisting of 5.5mm thick sheet glass of size 250 mm size triangle with CP brackets, gaurd and railing complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide 600mm long with aluminium alloy brackets and gaurd and railing 60cm long complete all as specified
M&L for coloured parking tile / varandah tile for 8-10mm thick set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed
S&F, install & testing Electrical chimney size 600L x 110W x 430 H cm complete with duct with cooker hood 6058 NBL Auto clean size 60 cm etc complete all as specified and directed by Engineer-in-Charge ,
M&L for Point wiring (Modular Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit (including Cutting Chases and make good the distrubed surfaces as per existing finishes) of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly suitable for 15 Amp Independent power point controlled by one 15 Amps modular Switch complete all as specified and directed.
S&F modular switch flush type single pole one way 16 Amp ISI marked complete all as specified and directed
S & F modular socket outlet 2 in 1, 6 Pin, 5 and 16 Amp flush type, 230 volts ISI marked complete all as specified and directed
Note:- (i)- Qty's have been clubbed from 2 Nos sanction Job's, BOQ Item Serial No 01 to 24, 26 to 27, 29 to 49 and 51 to 53 is consider in 06/ SR(BLDG) / JODH / 2025-26 & BOQ Item Serial No 54 to 75 is consider in JODH/MW/07/2025-26 and item No 25, 28 and 50 are clubbed as per page ser No 26 of tender documents. NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount.
Om Trading Corporation (BID ID -3413284)
M/S KAUTILYA GARG (BID ID -3419303)
M/S SUMAN ENTERPRISES (BID ID -3419357)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .