Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.2 LAccepted-AOC | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹29.7 L+₹53,789.70 (1.84%)Rejected-Finance PREM SAROVAR HOTEL NAINITAL 263 001 UTTARAKHAND | NAINITAL | UTTARAKHAND | 263001 | L-2 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
5 Nov 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
PROVISION OF MIXER WATER TAP FOR SMQs, PROVISION OF WASH BASIN IN SMQs, ADDITION / ALTERATION TO BUILDING NO. P/8, PROVISION OF SHED IN FRONT OF BUILDING NO. P/7 AND PROVISION OF CRASH BARRIER AT AF STATION BHOWALI.
2020_MES_385354_1
8554 / E8
Open Tender
Civil Works
Item Rate
180 days
Bhowali
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹60,000
Yes
31 Dec 2020
10 Oct 2020
7 Nov 2020
10 Oct 2020
5 Nov 2020
24 Oct 2020
10 Oct 2020 - 24 Oct 2020
Amount
S & F of 15 mm size brass chromium plated sink mixer with regular swinging spout (Wall mounted type) along with connecting legs and wall flanges as per Cat. Part No. FLR-5309N of Jaquar or having same specifications in MARC complete all as specified and directed.
Taking down 15 mm size PTMT bib tap any type complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Re-fixing of 15 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
S & F of 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
Cutting and screwing existing steel water tubing of 20 mm bore GI pipe any grade of alteration or additions of lengthening / threading and screwing pipe to form connection including insertion of new fittings as required complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 10 cm in girth complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for glazed ceramic jointfree coloured tiles 350 mm X 250 mm X 7 mm thick or 450 mm X 350 mm X 7 mm thick as per site requirement on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed in cement mortar 1:4, finished even and rough suitable for laying wall tiles complete all as specified and directed.
S & F of 15 mm size brass chromium plated basin mixer single lever without popup waste system along with 450 mm long copper pipe and brass nuts as per Cat. Part No. FLR-5001B of Jaquar or having same specifications in MARC complete all as specified and directed.
S & F of vitreous china wash basin white, flat back, size 450 X 300 mm including angle iron fixing brackets, 32 mm size chromium plated waste coupling alongwith PVC waste pipe, 450 mm long 15 mm bore size PVC connetion pipe, cutting for and pinning in as required complete all as specified and directed.
S & F of 15 mm bore fancy type, chromium plated angular stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F of 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf per Sqcm and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 60 cm long sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 120 mm wide with chromium plated bracket guard and railing complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for treating the back fill in contact with foundation at the rate of 7.5 litre of emulsion per Sqm of vertical surface (area of the sub structure in contact with back fill to be measured) complete all as specified and directed.
M & L for treating the junction of wall and floor at the rate of 7.5 litre of emulsion per Sqm of vertical wall surface complete all as specified and directed.
M & L for treating the top surface of filled earth at the rate of 5 litre of emulsion per Sqm of surface complete all as specified and directed.
M & L for treating the soil under plinth protection at the rate of 5 litre of emulsion per Sqm of surface area complete all as specified and directed.
M & L for treating the soil alongwith external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter of wall complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on other than fair faces of brick work or stone masonary surfaces finished even and fair without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
Supply only integral water proofing compound (Powder) complete all as specified.
M & L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND WILL BE MEASURED AND PAID SEPARATELY.
M & L for applying evenly a coat of blown type bitumen @ 1.50 Kg per Sqm including cleaning of surface and binding with clean dry sand @ 0.05 cum per Sqm complete all as specified and directed.
S & F of 50 micron thick black polythene film, laid in floor or DPC over a coat of bitumen primer @ 0.30 To 0.50 Kg per Sqm complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, in verical surface such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection or hardstanding, finished surface even and fair without using extra cement with and including all necessary form work as required complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Cutting opening through brick walls built in cement mortar for door, window and other opening or enlarging existing opening, converting window into door opening etc. including removing of surplus rubbish within 50 m distance complete all as specified and directed.
S & F of aluminium anodised powder coated of approved colour, sliding type three track window or ventilator with sliding shutter and frame with and including aluminium grill, 5 mm thick tinted glass and mosquito proofing net as detailed below complete all as specified and directed: - (i) Frame made of section size 92.00 X 31.75 X 1.30 mm. (ii) Shutter for top, bottom and side rails 40.00 X 18.00 X 1.30 mm. (iii) Glass 5 mm thick one side reflective glass and other side visible fixed with rubber gasket and aluminium clips of suitable size, 4 Nos. aluminium hold fasts with each window and necessary handles, tower bolt etc. as directed. (iv) Aluminium grill made of 5 mm dia powder coated aluminium section as per design No. DG-102 of make DEDO grill or design No. A-103 duly fixed with aluminium section 50 X 20 X 1.5 mm size. (v) Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of aperture 1.40 mm duly fixed with tined tacks or galvanised wire staples.
S & F of aluminum section powder coated of approved colour as in door frame and shutter partially glazed with 5.5 mm thick one side refelctive glass and partially panelled, panel made of 5 mm thick PVC composite board duly fixed with aluminium clips comprising of the following complete as specified and directed:- (i) Frame made of section size 100 x 40 x 2 mm thick. (ii) Styles of shutter made of section size 85 x 44.45 x 3 mm thick. (iii) Top rail made of section size 95.25 x 44.45 x 1.7 mm thick. (iv) Middle rail made of section size 83.50 x 44.75 x 1.7 mm thick. (v) Bottom rail made of section size 114.30 x 44.15 x 1.7 thick. (vi) Glazing aluminium clips made of 0.70 mm thick section. (vii) 2 Nos. Handle Powder coated Aluminium 200 mm long as approved. (viii) Tower bolt having dia of bolt 9.90 mm dia and 200 mm long. (ix) Mortice lock 100 mm size, 7 Livers make Godrej. (x) Hold fast aluminium 100 mm long. (xi) One No. Floor door spring with each shutter. (xii) 1 No. 300 mm long sliding door bolt of Aluminium duly Powder coated.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed.
S & F of 100 mm long B-21 type anodised butt hinge extruded aluminium alloy with galvanised mild steel hinge pin complete all as specified and directed.
S & F of 300 mm long mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts complete all as specified and directed.
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for complete removal of old decoration by scraping off the same from wall or ceiling surfaces of any description over 10 cm width or girth and applying two coats of distemper oil emulsion over one coat of primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
M & L for preparation of newly plastered previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
S & F of Hangers made of 6 mm dia GI wire (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made of GI flat 40 X 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
S & F of anodised aluminium snap grid frame work, size of grid 605 mm X 605 mm for false ceiling complete all as specified and directed.
S & F of 12 mm thick perforated particle board / tiles for insulation and accoustic purpose, 60 X 60 cm size fixed with staples on snap grid as in ceiling complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for Core Endura tiles (Super grip series) coloured (Ivory, Terracotta, Grey) of size (300 X 300 mm OR 400 X 400 m) X 10 mm thick in floors and the like, set and jointed with necessary adhesive / neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
S & F of mild steel screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 5 cm but not exc. 10 cm and diameter of the neck of bolt 11 to 15 cm complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in any type of soil, returning, filling and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F of galvanised mild steel channel having minimum galvanising @ 0.55 Kg per Sqm, of size 150 mm X 75 mm X 5 mm thick as in spacers and vertical post of crash barrier including cutting as per requirement and making hole for jointing, bolting as recommended by the manufacturer's complete all as specified and directed. MAKE- JINDAL, UTKARSH, HITECH.
S & F of galvanised mild steel 'W' beam having minimum galvanising @ 0.55 Kg per Sqm, 3 mm thick corrugated sheet metal beam fixed to spacers and vertical posts as in crash barrier including cutting as per site requirement and making hole for jointing, bolting as recommended by the manufacturer's complete all as specified and directed. MAKE- JINDAL, UTKARSH, HITECH.
S & F of galvanised mild steel bolts (machine made) suitable for crash barrier, with hexagonal head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal nut, length of bolt not exc. 5 cm and diameter of the neck of bolt 16 mm complete all as specified and directed.
S & F of 50 mm wide reflecting warning tape sticker, high visibility safety honeycomb conspicuity tape of any colour as directed complete all as specified and directed.
M & L for point wiring for one light point, fan point, bell point, 5 Ampere socket outlet point on independent board, controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 82.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of modular type socket outlet 6 Ampere, 2 and 3 Pin combination, 2 Modules complete all as specified and directed.
S & F of modular type switch 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 and 16 Ampere, 3 Pin for both rating (Total 6 Pins), 2 Modules complete all as specified and directed.
S & F of modular type switch 16 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of white cover plate with frame, 3 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 3 Module complete all as specified and directed.
S & F of white cover plate with frame, 4 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 4 Module complete all as specified and directed.
S & F of metal flush box 1 or 2 Module complete all as specified and directed.
S & F of white cover plate with frame, 1 Module suitable for modular type switches complete all as specified and directed.
Supply and fixing of single phase 'DING-DONG' electric call bell, AC 230 volts complete all as specified and directed.
S & F of modular type bell push 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of suspended surface mounting fullglow high efficiency glare free LED luminaire suitable for 2'x2' ceiling grid as per Cat. Part No. RC383B LED 36S-6500 PSU OD WH PIR (SmartGlow) of Philips or PLUTONEO2X2PLR42WLED857S (Pluto Neo Panel 2X2) of Havells or having same specifications in WIPRO, duly pre-fitted with all accessories complete all as specified and directed.
S & F of flush mounting factory made Ekinoxe SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of isolator, single pole and neutral, 40 Ampere breaking capacity 10 KA, 230 volts complete all as specified and directed.
S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 16 Sqmm 4 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
Ramsons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .