Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | ₹7.7 L Quoted ₹8.1 L | L1 | Accepted-AOC Being lowest bidder. |
| 2 | L2₹9.0 LRejected-AOC | ₹9.0 L | L2 | Rejected-AOC Being other than lowest bidder. |
| 3 | L3₹10.7 LRejected-AOC SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | ₹10.7 L | L3 | Rejected-AOC Being other than lowest bidder. |
| Sl No | Description | Qty | Unit | M/s Abhay Enterprises L1 | M/S SRIDEVI ENTERPRISES L2 | Haryana EngineerService L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for Overhauling / Servicing of Air Conditioning split /window type of any capacity installed at various location at ground floor/1st floor by means of removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including Oiling and greasing complete all as specified and directed. | 8 | Each Job | 1,000 ₹8,000 | 350 ₹2,800 | 999 ₹7,992 |
| 2.00 | All as per Srl Item No. 01 here in before but for Water Cooler any type, any cap and any make. | 4 | Each Job | 800 ₹3,200 | 280 ₹1,120 | 699 ₹2,796 |
| 3.00 | All as per Srl Item No. 01 here in before but for Refrigerator/ Deep freezers any make and type. | 2 | Each Job | 600 ₹1,200 | 160 ₹320 | 899 ₹1,798 |
| 4.00 | S&F in replacement of defective and broken copper suction pipe of including cutting of demage / worn out with the copper pipe soldering & brazing,flaring with insulation including all other accessories required at site directed. | 6 | RM | 300 ₹1,800 | 220 ₹1,320 | 499 ₹2,994 |
| 5.00 | S&F for Hermatically sealed unit compressor of 1.5 TR Capacity (replaced with orignal company repaired) suitable for working on SP, 50 HZ AC supply after taking out unsv compressor from window type A/C of any make including making necessary Refrigeraent pipe, elect connection, leakage testing, complete all as specified and directed. | 1 | Each | 9,200 ₹9,200 | 5,500 ₹5,500 | 9,999 ₹9,999 |
| 5.10 | All as per Srl Item No. 05.00 here in before but for Window AC 2 TR Capacity | 1 | Each | 9,500 ₹9,500 | 6,200 ₹6,200 | 11,999 ₹11,999 |
| 5.20 | All as per Srl Item No. 05.00 here in before but for Split 2 TR Capacity | 1 | Each | 10,000 ₹10,000 | 6,200 ₹6,200 | 11,999 ₹11,999 |
| 5.30 | All as per Srl Item No. 05.00 here in before but for Split 1.5 TR capacity | 2 | Each | 10,000 ₹20,000 | 5,500 ₹11,000 | 7,999 ₹15,998 |
| 6.00 | S&F for Hermatically sealed unit compressor of Capacity 40/80 Ltrs (replaced with orignal company repaired ) suitable for working on SP 50 Hz AC supply after taking out carfully from water cooler any type and make, including making necessary refrigerent pipe, elect connections including making leakproof, all as specified and directed. | 2 | Each | 6,500 ₹13,000 | 4,700 ₹9,400 | 6,999 ₹13,998 |
| 6.10 | All as per Srl Item No. 06.00 here in before but for Refrigerator of any make, (165 to 210 Ltrs) | 1 | Each | 6,800 ₹6,800 | 3,800 ₹3,800 | 9,999 ₹9,999 |
Updated dates
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
4 Feb 2026, 6:00 pmClosed
GE (East) Bareilly
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
8477/E8 COMPREHENSIVE MAINT INCL REPAIR / REPLACEMENT OF PARTS OF MES INSTALLATION AND STREET LIGHTS AND VARIOUS SUMMER APPLIANCES HELD ON CHARGE OF STATION UNIT AT RTS AND DEPOT HEMPUR UNDER GE (EAST ) BAREILLY
2026_MES_747528_1
8477/E8
Open Tender
Electrical and Maintenance Works
180 days
Hempur under GE (East) Bareilly
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹25,000
Yes
7 May 2026
7 Jan 2026
11 Feb 2026
7 Jan 2026
4 Feb 2026
21 Jan 2026
M&L for Overhauling / Servicing of Air Conditioning split /window type of any capacity installed at various location at ground floor/1st floor by means of removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including Oiling and greasing complete all as specified and directed.
All as per Srl Item No. 01 here in before but for Water Cooler any type, any cap and any make.
All as per Srl Item No. 01 here in before but for Refrigerator/ Deep freezers any make and type.
S&F in replacement of defective and broken copper suction pipe of including cutting of demage / worn out with the copper pipe soldering & brazing,flaring with insulation including all other accessories required at site directed.
S&F for Hermatically sealed unit compressor of 1.5 TR Capacity (replaced with orignal company repaired) suitable for working on SP, 50 HZ AC supply after taking out unsv compressor from window type A/C of any make including making necessary Refrigeraent pipe, elect connection, leakage testing, complete all as specified and directed.
All as per Srl Item No. 05.00 here in before but for Window AC 2 TR Capacity
All as per Srl Item No. 05.00 here in before but for Split 2 TR Capacity
All as per Srl Item No. 05.00 here in before but for Split 1.5 TR capacity
S&F for Hermatically sealed unit compressor of Capacity 40/80 Ltrs (replaced with orignal company repaired ) suitable for working on SP 50 Hz AC supply after taking out carfully from water cooler any type and make, including making necessary refrigerent pipe, elect connections including making leakproof, all as specified and directed.
All as per Srl Item No. 06.00 here in before but for Refrigerator of any make, (165 to 210 Ltrs)
S&F in repair for overload protector for Water coolers 40/80 Ltr complete all as specified and directed. Make Shriram/Hiteck /Keltron
All as per Srl Item No. 07.00 here in before but for AC 1.5 TR/WC 40/80 Ltr Capacity
All as per Srl Item No. 07.00 here in before but for AC 2.0 TR/WC 40/80 Ltr Capacity
M & L for replacment of old unsv starting relay carefully from window/Split type AC of 1 to 2 TR capacity of any make including making necessary elect connections, complete all as specified and directed. (Make - Arvind/Shriram or equivalent as approved by GE)
All as per Srl Item No.08.00 here in before but for water coolers 40/80 to 150 Ltr capacity
M & L for opening body of water coolers, taking out cooling tank to rectifiy leakage of refrigerant tube/condensor and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and directed.
M & L in repair for taking out burnt fan motor 1/6 or 1/7 HP from window type AC of any size / capacity and replacement with new, providing insulation material, replacement of bushes/ shaft and refixing including making necessary electric connections complete all as specified and directed.
S&F in replacement fan Motor for split type A/C (1,1.5,2 TR Capacity) complete all as specified and directed.
S&F in replacement DC Motor for split type A/C (1,1.5,2 TR Capacity) complete all as specified and directed.
S&F in replacement swing Motor for split type A/C (1,1.5,2 TR Capacity) complete all as specified and directed.
S&F in replacement fan blade for window/split type A/C (1,1.5,2 TR Capacity) complete all as specified and directed.
S&F in repair of indoor unit of split AC 1.5 TR, 5 Star, (in replacement of worn out unit comprises of cooling coil, blower motor, swing motor, swing blade filter PCB, thermostat) complete all as specifird and as directed.
S&F in repairs of outdoor unit of split AC 1.5 TR, 5 Star (in replacement of warn out of existing comprises out door fan motor, out door fan, condenser unit with cooling coil cooper / alluminium fins, wiring as per existing with connection for indoor and outdoor with copper tubing) complete all as specified and directed.
S&F in repairs of indoor unit complete of split AC 2.0 TR (in replacement of worn out unit comprises of cooling coil , blower motor, swing motor, swing blade filter PCB, thermostat complete all as specifird and as directed.
S&F in repairs of outdoor unit split AC 2.0 TR (in replacement of warn out of existing comprises out door fan motor, out door fan, condenser unit with cooling coil cooper / alluminium fins, wiring as per existing with connection for indoor and outdoor with copper tubing complete all as specifird and as directed.
S&F vaccum magnetic rubber for frount door suitable for Refrigerator any capacity of existing size and make complete all as specifird and as directed.
M&L for charging of refrigerant R-22 in window / split type AC / Water cooler of any make (1.5 & 2 TR Capacity) carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak-proof including testing for leakage, and optimum grill temperature complete all as specified by the manufacturer and directed.
All as per Srl Item No. 21.00 here in before but R/12 refrigerant for water coolers any make refrigerator 165 to 310 ltrs.
S& F in replacement fan motor AC 230 V high speed suitable for split AC 1.5/2 ton for any Make of AC all as specified and directed.
S& F in replacement fan motor AC 230 V suitable for Water cooler for any capacity & any Make of AC complete all as specifird and as directed.
S & F in replacement new remote assembly for split/widow type AC 1.5/2 ton of any make & existing mode complete all as specifird and as directed.
S & F after taking out unserviceable defective PCB plate and fixing new remote control kit/ PCB plate in existing position with all electric connections complete and all as directed by EIC in 1.5/2 ton split type AC of any make and any type complete all as specifird and as directed.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 6mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and directed.
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specifird and as directed.
M&L and for minor repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deseret cooler/voltage stabliser by Tecnician carry out minor repair and making functional complete all as specified and directed at site.
M&L for shifting of existing Air Conditioners window AC of 1.5/2 ton capacity from one place to another place,any height/ any floor as per requirement of users any make and new re-installation and commissioning the unit inluding cutting of window/wall as required at site complete,including making good in orginal condition and testing after gas charging complete all as specified and as directed.
M&L for shifting of existing Air Conditioners Split type of 1.5/2 ton capacity from one place to another place as per requirement of users any make and new re-installation and commissioning the unit by using additional copper tubing of required size bent to shape including brazing insulation etc testing after gas charging ,including making hole on the wall and MS fastenar 10 to 12 cm long including making good in orginal condition complete including making on wall complete all as specified and as directed.
Supply and fix of automatic boost/buck transformer for low and high voltage correction equipped with electronic transistorized relay suitable for correction on single phase, 50 cycles, AC supply, naturally air closed, indoor type complete with voltmeter and designed for input voltage of 170V to270V and output voltage stabilized between 215V to 240V of capacity 5 KVA complete all as specified and as directed.
Supply and charging of R-134a refrigerant gas complete all as specified and as directed.
Supply and Fixing & Replacement split AC (1.5 & 2 Ton) stands including fasterner, grounding, nut-bolt and washer complete.as per site requrment as directed.
Supply fixing and clamping jointing copper tubing of standard size for suction line and for liquid discharge line duly insulated with and including nitrile rubber insulation material including making hole in wall for passing through and making good the disturbed surface complete all as specified and directed.
M&L for replacement of wiring kit suitable for window/split type AC 1.5 ton capacity including soldering tapping and thimbling etc complete all as specified and as directed.
M&L for LT steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31 (9mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulator and electric connection etc, complete all as specified and directed.
M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection laid in trenches or above ground surface, complete all as specified and directed.
All as per Item No 37.00 above but here in before of size 40mm dia.
M&L for MCCB 4 pole, 415 volts, adjustable type, 63 Amps with breaking capacity 16 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 volts, adjustable type, 100 to 160 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 volts, adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fixing for LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection, complete all as specified and as directed.
All as per item No 41.00 above but here in before of 90 watt 230 V AC outdoor type.
All as per item No 41.00 above but here in before of 120 watt 230 V AC outdoor type.
S & F for GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed on wall with flat iron clamps of size 25 x 4mm - 2 Nos with the help of bolts, nuts, washers etc for fixing of security light fitting, complete all as specified and as directed.
Supply and fixing for Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED Solar street light fitting 20/24 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately) complete with IP 65/66 protection, complete all as specified and as directed.
Supply and fixing for LED flood light fittings 210 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection, complete all as specified and as directed.
All as per above but here in before of 120 watt 230 V AC outdoor type.
Supply and fixing in replacement of lead acid battery 12 Volt, 150 AH, suitable for DG Set complete all as specified and as directed.
M & L for Junction boxes with PVC water tight encloser, ready made type, aluminium bus bar 25x3 mm, 200mm long fixed on post insulators, nut & bolts, MS Camps including 2.5 sqmm cable for street light connection& controlling with one number single pole MCB 6A, 230 Volts complete.
Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 25 sqmm x 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed.
All as per item No 49.00 above but here in before of size 16 sqmm x 4 core.
All as per Item No 49.00 but here in before of size 16 sqmm x 2 core.
All as per Item No 49.00 but here in before of size 10 sqmm x 2 core.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. Note : Rates includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.58 MB
Tender8477.pdf
Tender Documents • 1.72 MB
BOQ_837114.xls
BOQ • 1.54 MB
Download all tender documents and submit your bid