Executive Engineer, Electrical (R&B) Division, Valsad
Providing Solar Rooftop System on New Workshop & Theory Room Building at ITI, Bilimora, Ta. Gandevi, Di. Navsari.
353213
Online Tender Notice No. 16 of 2026-27 (Second Attempt)
Open
Electrical Works
Works
Valsad
8 documents required · 8 mandatory
₹1,500
Executive Engineer, Electrical (Rand B) Division, Valsad
₹25,500
7 Oct 2026
7 Oct 2026
7 Oct 2026
15 Oct 2026
7 Oct 2026
Name of Providing Solar Rooftop System on New Workshop & Theory Room Building at ITI, Bilimora, Ta.
work : Gandevi, Di. Navsari.
Qnty Sr.No. Item Description Rate After Rs in Words Amount
1 Supply, Installation, Testing & Commissioning of following size of Grid Tied
Solar Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum
alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-
Iron Tempered Glass (AR Coated), High efficency and positive power
tolerance Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%,
Normal operating temperature 45'C, Junction Box with Waterproof IP67 &
MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than -0.45%/degree C. Solar
PV modules of minimum fill factor 75% to be used. Unit Production:- More
than 4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty.
Modules must be complied to the DCR(Domestic content requirements). The
Ration of AC to DC is 5:6 for the Installation capacity which are given in AC
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency:
97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p
Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection, Output
Short Circuit Protection, Output Over Voltage Protection, PV array string
fault Protection. Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection Integrated, Protection Degree:
IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-
Fi, Module Mounting Structure: The mounting (Rectangular pipe / square
pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot
deep galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness should be
minimum 2.5 mm. A certificate of a structural engineer certifying the strength
and stability of the mounting structure to withstand the weight and wind
speed of 150 km/hour , shall be submitted by the vendors. Hot Dipped
Galvanized steel coils. suitable arrangement for base plate for foundation
solar panel mounting, the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with necessary foundation work/wall
mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture
should be (SS 304) quality.The ground clearance of the bottom most edge of
solar panel shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM
Balane of System with necessary Swichgears (Suitabel size and protection of
ACDB & DCDB), inter connecting wiring, earthing system as per the CEIG
drawing approval, lightining arrester systerm as per the CEIG drawing
approval, all liasoning work with various gov. dipartment like state nodal
agency, DISCOM & CEIG is included in agency scope.
lightining arrester system as per the CEIG drawing approval, all liasoning
work with various gov. dipartment like state nodal agency,DISCOM & CEIG
is included in agency scope (Excluding All charges namely GEDA
Application fees, Solar connectivity Charges, Meter connectivity Charges,
Meter testing Charges and system stability/strenthning charges.)
60 (E) Grid Tied Solar Power System: 51 - 100 kW (3 - phase) 40658.56 Rupees Forty
Paise Fifty Six
60 2 Providing & erecting Automatic solar panel cleaning system for solar power 1776.59 Rupees One
projects which includes necessary plumbing work (UPVC pipes and Thousand
accessories) from source of water to project site (up to 30 meters),Suitable Seven Hundred
size of sub mercible/ open well motor, necessary wiring for motor and Seventy Six
sprinkler system with safety, timer circuit for automatically on/off the And Paise Fifty
sprinkler system, necessary size oand number of nozzles/JET (minimum 1 Nine Only
Nozzle/Jet per module). (E) 51KW-100KW Cleaning System
Deputy Executive Engineer Executive Engineer
Electrical R & B Sub-Division Electrical R & B Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B Solar ITI Navsari.pdf
Special Conditions.pdf
Supply and Installation Commissioning with 5year CMC of Solar.pdf
4.0 FINAL _ SBD (Electrical Work) _ 2024 _ 120 pg (1).pdf
ELEGIBILITY CRITERIA.pdf
Notic No 16 of 2026-27 Second Attempt Solar.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .