Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | ₹6.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.1 L+₹67,818 (10.6%)Rejected-AOC | ₹7.1 L+₹67,818 (10.6%) | L2 | Rejected-AOC L2 |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
26 Feb 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
PROVN OF RAILING , STAIR CASE, PCC PATH TO WATCH TOWERS,WEATHER SHELTER,DRAINAGE SYSTEM AND RAIN WATER GUTTER AT AF STATION KASAULI UNDER GE AF CHANDIGARH
2021_MES_417149_1
GE (AF)/CHD/T-51/2020-2021
Open Tender
Civil Works
Item Rate
180 days
Kasauli
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹15,000
Yes
25 Mar 2021
29 Jan 2021
1 Mar 2021
29 Jan 2021
26 Feb 2021
12 Feb 2021
Amount
Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface (hard/dense soil) complete all as specified and directed by Engineer-in-Charge.
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil Complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc. or for shafts, wells, cesspits,manholes, and getting out in hard/dense soil Complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils Complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as spcified and directed.
M&L for 75mm thick Cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) in sub-floors, sub-bases, floors and pavings Complete all as specified and directed by Engineer-in-Charge.
M&L for 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings complete all as specified and directed.
M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete Complete all as specified and directed by Engineer-in-Charge.
M&L brickwork with sub class 'B' bricks straight or curved on plan exc 6m mean radious, built in CM 1:6 complete all as directed by Engineer in Charge.
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished with even and smooth Complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 , complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:2:4 type B -2 (using 40 mm graded crushed stone aggregate) as in posts, complete all as specified and directed.
M&L Preparation of new previously untreated steel surfaces of any despcription, over 10 cm width or girth, otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer in Charge.
S&F Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W(Gde-E- 250) quality-A complete all as specified and directed by Engineer in Charge.
S&F Rolled mild steel as in Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W(Gde-E- 250) quality-A complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws,complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and directed by Engineer-in-Charge.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc ,complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:2:4 type B-2 using 40mm using graded crushed stone aggregate in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:2:4 type B -1 (using 20 mm graded crushed stone aggregate) as in coping/benching incl necessary formwork, weathering, slightly rounded or chamfered angles, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape reqd incl cranking, bending spirally for hooping for columns hooking ends and binding with with and including mild steel wire not less than 0.90mm dia Complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete (nominal mix) type B1, 1:2:4 using 20 mm aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Complete all as specified and directed by Engineer-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required,hooks (stay), heavy, for largegates; hook and pintle hinges: large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 Complete all as specified and directed by Engineer-in-Charge. Note: Item to be executed at 10 metres height.
S&F 0.80mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 Complete all as specified and directed by Engineer-in-Charge.
S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore of pipe complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed by Engineer-in-charge.
S&F 100mm Nozzle pieces (Out lets) with gutter of 1mm thickness of sheet complete all as specified and directed by Engineer-in-charge.
Varindera And Varindera Construction
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .