Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 30 74 BLOCK NO EXTRA 30 TRILOK PURI DELHI EAST DELHI 110091 | DELHI | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC Selected |
Tender Value
₹18.0 L
EMD Value
₹35,920
Closing Date
1 May 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Providing of Electrical Work
2019_PWD_171964_1
24 /EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
60 days
Delhi.
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹35,920
20 Oct 2020
20 Apr 2019
1 May 2019
20 Apr 2019
1 May 2019
20 Apr 2019
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit etc as required. a) 2 x 1.5 sq. mm
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 Volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Ampers, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a) 8 way (4 + 24), Double door
Supplying and fixing of 5 Ampers to 32 Ampers rating, 240/415 Volts, 10 kA breaking capacity, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. a) Single pole
Providing and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 200 Ampers, 16 kA, breaking capacity TPMCCB
Supplying & fixing of energy efficient 7 watts LED down lighter luminaries with the help of DL-7-6K frame in the recessed including connection, testing etc. as required. The Total minimum system efficacy of luminaries should be minimum 80 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying and fixing of 400 mm sweep size wall mounted fan complete with inbuilt Electronic Regulator, Blade, wire lead with moulded plug top etc. as required.
Supplying, Installation, Testing and Commissioning of energy efficient cassette type Air Conditioner unit of minimum 2 TR capacity, 6000 k cal/hour capacity complete with outdoor condensing unit & ceiling mounted evaporating unit having cordless remote control with angle iron rod, clamp & fastner type hook for supporting of indoor unit, capable of cooling, filtering & dehumidifying, suitable for operation on 230Volts, single phase, AC supply complete with copper refrigeration pipe up to 4 meters length and suitable length of drain pipe with outdoor unit stand etc. as required
Supplying, installation, testing & commissioning of energy efficient 2 TR capacity Split type Air Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required.
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75 mmX75 mm)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit etc as required. a) 25 mm
Supplying and drawing of UTP 4 pairs CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. a) 1 run of cable
b) 2 run of cable
c) 3 run of cable
Supplying and fixing of RJ-45 Cat-6 in existing modular box with connection as required.
Supplying and fixing of Digital display wall mounting type Servo Voltage Stabilizer of following capacity for 2 TR capacity Air-Conditioner unit complete etc as required. a) 5 KVA(Input -165-280 Volts)(Output195-245 Volts)
Providing & Laying of refrigerant copper piping of size 5/8” & 1/4” diameter from indoor unit to outdoor unit of cassette/split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of duly insulated PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc as required. (Measurement to be done for quantity after 4 meters, which is included in item no -10 & 11)
Providing and fixing of 25 mm diameter PVC Heavy duty pipe for sweating water dragged in the existing Air Conditioner’s Clamp etc. Complete as required
Providing and fixing heavy duty portable powder coated stand for fixing the outdoor unit on the surface of wall etc. complete as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Ampers modular socket outlet and 5/6 Ampers modular switch, connections etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 Ampers & 15/16 Ampers modular socket outlet and 15/16 Ampers modular switch, connections etc. as required.
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
Supplying, installation, testing & commissioning of 20 to 22 watt, 6000K, 1200 mm long energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thickness including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meters long etc. with charcoal/ coke and salt as required.
Providing and fixing of 3 core flexible PVC insulated wire of size 2.5 Sq. mm including testing etc as required.
Supplying and laying of 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Supplying and installation of Heavy duty exhaust fan of 380 mm sweep size, 900 rpm speed with shutter & louvers in the existing opening alongwith connection, testing & commissioning etc as required.
Providing optical smoke detector with base, Blinking LED type complete with connections, testing & commissioning etc as required.
Providing and fixing of flexible joint for sprinkler of 1.0 Meter Length having male inlet of 25 mm diameter at one end and female out let of 15 mm diameter at other end only UL listed, FM approved together with providing & fixing G.I. Spotter 25 mm diameter, G.I. Nipple 25 mm diameter and Rosetter of stainless steel duly polished for 15 mm diameter sprinkler head etc as required.
Supplying, installation, testing and commissioning of 10 KVA capacity 3 phase input to 1 phase output, solid state type true on line fully micro processor controlled double conversion PWM IGBT with pollution free instantaneous sine wave control. Parallel redundant for redundancy or capacity enhancement. Inbuilt static switch useful for starting inrush current. Manual bypass switch for easy maintenance. Alpha numeric LCD display for status and alarm in real time. Wide frequency synchronization range upto 10% based UPS system with paralleling kit and battery bank of 20 Nos. 65AH/12 Volts SMF battery to provide 30 minutes power backup at full load along with BCB, Racks, copper cable and required software etc
Supplying, installation, testing and Commissioning of following zone microprocessor based networkable programmable communicator fire alarm control panel (each zone accessing minimum 50 nos. units) wall mounted type fabricated out of 1.2/1.6 mm CRCA sheet, dust and vermin proof, powder coated, complete in all respect suitable for operation on 220V, AC supply, 50Hz power supply and battery charger. The panel shall be (ERTL/TAC/C/LPCB/EN-54 certified) with standard feature including dismantling along with credit for wornout accessories under buy back arrangement etc as required. a) 8 Zone
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .