Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.9 L+₹6.0 L (37.8%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹16.6 L
EMD Value
₹32,500
Closing Date
29 Jan 2024, 11:00 amClosed
Executive Engineer
Jal Shakti Division Bilaspur
Providing LWSS Banoha, Bhagwani, Ransal and adjoining villages in Tehsil Ghumarwin District Bilaspur (SH Laying, jointing and testing of rising main in Booster and 1st stage, providing and errection of submersible pumping machinery for booster stage
2024_HPIPH_84208_1
BLP-BLP-00736 NIT No. 25285-384 dated 17/01/2024
Open Tender
Civil Works
Item Rate
180 days
Sub Division Kandrour Section Harlog
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
EE JSV Bilaspur
₹32,500
Yes
21 Sept 2024
19 Jan 2024
29 Jan 2024
19 Jan 2024
29 Jan 2024
19 Jan 2024
Amount
Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling/wedging out of rock/where blasting prohibited) saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge.
Laying,jointing and testing GMS Pipes jointed with 5% joint flanged and remaining butt weld joint of below dia mtr i/c the cost of bends ) complete as per IS:1239-1990 (Part-I) , as per dimensions, weights and test pressures mentioned below in a random length of 4 to 7 meters. The Butt welded joints & MS Flanges are to be provided on each joint as per table given below conforming to IS:6392 - 1971 and welding of flanges with electrodes as per relevants codes including required number & size of nuts and bolts as per relevants codes and asbestos fibre jointing gasket sheet not less than 3mm thickness as per relevants codes . The welding of flanges to be done on both faces in three layers to make the joints leak proof and to entire satisfaction of the Engineer-in-charge. The laying of pipe should be conformed to IS:5822-1994. (Earth work in trenches, Flanged joints & Butt weld joints to be measured and paid for separately )
Booster & 1st Stage GMS pipe (Heavy Class) 65 mm dia. with wall thickness of 4.50,outer dia.of 76.60 mm, having wt. of pipe 8.05 Kg/Rmt
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of MSERW pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.tion of Engineer-in-Charge.
Booster & 1st stage GMS pipe (H.C.) 65mm dia table-5
1st Stage GMS pipe (H.C.) 65mm dia table-17
Providing circumferencial Butt welded joints by electrical arc welding to GMS/MSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes conforming to IS:814-1991, at site of work complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
Booster & 1st Stage GMS pipe 65mm dia rising main
Providing and installation of Submersible pumping set of KSB/ Kirloskar/Oswal/Johnston Crompton make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per BIS 8034-2018 relevant code with latest ammendments for clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible motor (water proof type) of required HP, RPM 2900 of Reputed make conforming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps, cable clips and depth gauge etc. and suitable for operation on data given below:- Please refer SOQ uploaded in PDF format for specification, quantity and unit of below items:-
Providing, Installation, Testing and Commissioning of DOL Starter panel for submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. submerisble pump set (one working) incuding all other required accessories etc.
DOL and Mains Power Contactors of required ratings as per type-2 co-ordination for 2 sets of required HP starter
Voltage Protection device to protect panel from over voltage and under voltage for the above rating of machinery.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi-function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make MAS/L&T.
Main incomer MCCB/MCB of suitable for 2 sets of required rating motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).
Individual Starter incomer MCCB/MCB suitable for 2 sets of required rating motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with up to date amendments.
LED On / Off & Trip indicator and push buttons, Control and power wiring,Powercapacitor,Cooling fan 230 VAC, Control terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge suppressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges for above rating.
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.
50mm dia Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications
Providing and fixing of Kirloskar/Leader/ Kartar make cast iron (class PN-1.0) double flanged sluice valve of size one dia heigher the delivery of pump and capable of withstanding norminal seat pressure 10.20 kg/cm2 as per IS: 780-1984 part-I). or latest ammendements.
Providing and fixing of Kirloskar/Leader make cast iron (class PN-1.0) double flanged (swing check type) reflux valve / Non return valve of size one dia higher than delivery of pump having bye pass arrangement on delivery line and capable of withstanding nominal seat pressure of 10.20kg/cm2 as per BIS: 5312-1984 (Part-I). or latest ammendements.
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date ammendments siemen/closter/ICC make form meter of HPSEB- to MCB and form MCB to Busbar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type , size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer.Supply side if suitable size.
Providing and fixing of Leader/ Kirloskar make 65mm dia cast iron, class PN-1.0 double flanged swing /Reflux/ Non Return valve having bye pass arrangement and 65 mm dia of rising main for withstanding nominal seat pressure 10.20kg/cm2 as per IS: 780-1984 (part-I) or latest amendments
Providing and fixing of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date ammendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender of suuitable size.
Providing and laying double loop earthing with G.I wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date ammendments for above motors and other electrical equipment’s.
Providing and fixing of standard make circular dial pressure gauge 0-11 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc. conforming to IS: 3624-1987 latest with upto date ammendments.
Providing and laying delivery pipe 50 mm dia and common header 65 mm dia as per IS: 1239-1990 (Part-I) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.
Providing and fixing of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date ammendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form busbar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range tobe specified by the tendrerer).
CENTRIFUGAL PUMPING MACHINERY Providingand installation of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump or combination of pump Kirloskar/KSB/ M&P make pump as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments Please refer SOQ uploaded in PDF format for specification, quantity and unit of below items:-
Providing, Installation, Testing and Commissioning of premium Star Delta Starter panel for Centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps each of the required rating through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators.
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for starter of required rating.
Voltage Protection device to protect panel from over voltage and under voltage for the above rating of machinery.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi-function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make MAS/L&T.
Main incomer MCCB/MCB of suitable for required rating motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).
Individual Starter incomer MCCB/MCB of suitable for required rating motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with up to date amendments.
LED On / Off & Trip indicator and push buttons, Control and power wiring,Powercapacitor,Cooling fan 230 VAC, Control terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge suppressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges for above rating.
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.
Providing and fixing of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition)
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar make 50mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 780-1984 class PN-1 with up to date amendments.
Providing and fixing double flanged Cast steel sluice valve on delivery line of Leader/Kirloskar/ KSB make and size one dia higher the delivery of pump and capable of with standing the 52 Kg/cm2 seat pressure and as per BS –1414/ API-600(class-ASA-300) with up to date amendments.
Providing and fixing o double flanged (Swing type) Cast steel reflux valve of Leader/Kirloskar/KSB make of size one higher the delivery of pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per BS-1868/ API-600(class, ASA-300 working pressure 52/cm2 with flange table-17 with up to date amendments
Providing double flanged Cast steel non return valve of Leader/ Kirloskar/KSB make and of 65 mm dia. having bye pass arrangement for rising main and capable of seat pressure 52kg/cm2 with flange table-17 as per per BS –1868/ API-600(class, ASA-300) up to date amendments
Providing and fixing double flanged G.M.S. piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:
Suction pipe: 50mm dia with flange table-5
Delivery pipe: 50mm dia with flange table-17
Common header: 65mm dia
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Motor side: Suitable size Supply side :Suitable size
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm copper & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Metro Suppliers and Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .