Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹3.5 L (1.83%)Admitted-Finance | ₹1.9 Cr+₹3.5 L (1.83%) | L2 | Admitted-Finance |
| 3 | L3₹3.3 Cr+₹1.3 Cr (70.4%)Admitted-Finance | ₹3.3 Cr+₹1.3 Cr (70.4%) | L3 | Admitted-Finance |
| 4 | L4₹3.4 Cr+₹1.5 Cr (78.8%)Admitted-Finance | ₹3.4 Cr+₹1.5 Cr (78.8%) | L4 | Admitted-Finance |
| 5 | L5₹3.4 Cr+₹1.5 Cr (78.9%)Admitted-Finance IX 526 527 HILL PALACE ROAD KARINGACHIRA IRUMPANAM P O TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | ₹3.4 Cr+₹1.5 Cr (78.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Amity Projects and Construction L3 | DELTA CONSTRUCTIONS L2 | S K BOILERS PVT LTD L5 | DEEPAK ENGINEERING WORKS L4 | SKIDTECH ENGINEERING PVT LTD L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00SUPPLY OF PIPES AND FITTINGS | ||||||||
| 1.01 | CS PIPE, A333Gr.1, SMLS 25 NB, SCH.80 | 720 | M | 4,68,000 ₹5,52,240 | 3,44,880 ₹4,06,958.4 Lowest | 5,25,600 ₹6,20,208 | 5,04,000 ₹5,94,720 | 5,40,000 ₹6,37,200 |
| 1.02 | CS PIPE, A333Gr.1, SMLS 80 NB, SCH.40 | 6 | M | 9,492 ₹11,200.56 | 8,094 ₹9,550.92 Lowest | 10,200 ₹12,036 | 9,600 ₹11,328 | 9,000 ₹10,620 |
| 1.03 | CS PIPE, A333Gr.1, SMLS 250 NB, SCH.40 | 12 | M | 1,17,864 ₹1,39,079.52 | 95,988 ₹1,13,265.84 Lowest | 1,26,000 ₹1,48,680 | 1,17,600 ₹1,38,768 | 1,20,000 ₹1,41,600 |
| 1.04 | CS PIPE, A333Gr.1, SMLS 300 NB, SCH.40 | 360 | M | 48,42,000 ₹57,13,560 | 41,10,840 ₹48,50,791.2 Lowest | 54,91,800 ₹64,80,324 | 50,40,000 ₹59,47,200 | 41,40,000 ₹48,85,200 |
| 1.05 | CS PIPE, API 5L Gr.B,PSL1, SMLS 25 NB, SCH.80 | 360 | M | 1,78,920 ₹2,11,125.6 | 1,43,640 ₹1,69,495.2 Lowest | 1,90,800 ₹2,25,144 | 1,90,800 ₹2,25,144 | 2,70,000 ₹3,18,600 |
| 1.06 | PIPE, A312 TP304, SMLS 25 NB, SCH.40S | 360 | M | 4,66,560 ₹5,50,540.8 | 4,60,440 ₹5,43,319.2 | 5,29,200 ₹6,24,456 | 5,04,000 ₹5,94,720 | 2,70,000 ₹3,18,600 Lowest |
| 1.07 | API 5L Gr.B PSL 1, ERW, BE 80 NB, SCH40 | 6 | M | 13,932 ₹16,439.76 | 5,994 ₹7,072.92 | 14,850 ₹17,523 | 8,400 ₹9,912 | 4,800 ₹5,664 Lowest |
| 1.08 | API 5L Gr.B PSL 1, ERW, BE 100 NB, SCH40 | 6 | M | 20,304 ₹23,958.72 | 8,694 ₹10,258.92 | 21,600 ₹25,488 | 10,200 ₹12,036 | 7,500 ₹8,850 Lowest |
| 1.09 | API 5L Gr.B PSL 1, ERW, BE 150 NB, SCH40 | 420 | M | 19,16,460 ₹22,61,422.8 | 9,36,600 ₹11,05,188 | 20,37,000 ₹24,03,660 | 17,85,000 ₹21,06,300 | 8,40,000 ₹9,91,200 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
1 Sept 2020, 11:00 amClosed
SM(Mat)-C
SM(Mat)-C Corporate Materials Dept. FACT Ltd
Transfer and extension of Ammonia Ship unloading facility from SCB to Q1 berth
2020_FACT_576351_1
04085/2020-2021/E21907
Open Tender
Miscellaneous Works
Works
69 days
FACT Ammonia Handling section, Willington Island
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1 L
Yes
FACT Ammonia Handling section ,Willington Island
14 Sept 2020
8 Aug 2020
2 Sept 2020
8 Aug 2020
1 Sept 2020
8 Aug 2020
17 Aug 2020
SUPPLY OF PIPES AND FITTINGS
CS PIPE, A333Gr.1, SMLS 25 NB, SCH.80
CS PIPE, A333Gr.1, SMLS 80 NB, SCH.40
CS PIPE, A333Gr.1, SMLS 250 NB, SCH.40
CS PIPE, A333Gr.1, SMLS 300 NB, SCH.40
CS PIPE, API 5L Gr.B,PSL1, SMLS 25 NB, SCH.80
PIPE, A312 TP304, SMLS 25 NB, SCH.40S
API 5L Gr.B PSL 1, ERW, BE 80 NB, SCH40
API 5L Gr.B PSL 1, ERW, BE 100 NB, SCH40
API 5L Gr.B PSL 1, ERW, BE 150 NB, SCH40
FLANGES 300#, WNRF, B16.5, A350-LF2 25 NB
FLANGES 300#, WNRF, B16.5, A350-LF2 80 NB
FLANGES 300#, WNRF, B16.5, A350-LF2 250 NB
FLANGES 300#, WNRF, B16.5, A350-LF2 300 NB
FLANGES 150#, SW,RF, B16.5, A182 Gr.F304 25 NB
FLANGES 150#, SW, RF, B16.5, A105 25 NB
FLANGES FIRE WATER LINE 150#, SORF, B16.5, A105 80 NB
FLANGES FIRE WATER LINE 150#, SORF, B16.5, A105 100 NB
FLANGES FIRE WATER LINE 150#, SORF, B16.5, A105 150 NB
BLIND FLANGES (PRODUCT AND UTILITY LINE) 300#, RF, B16.5, A350-LF2 25 NB
BLIND FLANGES (PRODUCT AND UTILITY LINE) 300#, RF, B16.5, A350-LF2 80 NB
BLIND FLANGES (PRODUCT AND UTILITY LINE) 300#, RF, B16.5, A350-LF2 300 NB
BLIND FLANGES (PRODUCT AND UTILITY LINE) 150#, RF, B16.5, A182 Gr.F304 25 NB
BLIND FLANGES (PRODUCT AND UTILITY LINE) 150#, SW, RF, B16.5, A105 25 NB
90o ELBOW,3000#, SW, B16.11, A350-LF2 25NB
90o ELBOW,SCH40, BW, B16.9, A420-WPL6 300NB
90o ELBOW,3000#, SW, B16.11, A182 Gr.F304 25NB
90o ELBOW,3000#, SW, B16.11, A105 25NB
45o ELBOW,SCH40, BW, B16.9, A420-WPL6 300NB
EQ.TEE,3000#, SW, B16.11,A350-LF2 25NB
EQ.TEE,SCH40, BW, B16.9,A420-WPL6 80NB
EQ.TEE,SCH40, BW, B16.9,A420-WPL6 300NB
ECC. RED, SCH40 , A420-WPL6 300NBx250NB
NIPPLE BEP,SCH 80, A333 Gr.1,SMLS 15NB
NIPPLE BEP,SCH 80, A333 Gr.1,SMLS 25NB
NIPPLE OET,SCH 80, A333 Gr.1,SMLS 15NB
HALF CPLG.,3000#,SW,B16.11,A350-LF2,15NB
HALF CPLG.,3000#,SW,B16.11,A350-LF2,25NB
FULL CPLG,3000#,SW, B16.11,A350-LF2 25NB
FULL CPLG,3000#,SW, B16.11, A182, Gr.F304 25NB
FULL CPLG,3000#,SW, B16.11, A105, 25NB
RED.CPLG,3000#,SW, B16.11,A350-LF2 25NB x 15NB
90o ELBOW,A234 Gr.WPB-W,BW 150NB,SCH40
EQ.TEE,A234 Gr.WPB-W,BW 150NB,SCH40
A320-L7 STUD BOLT & A194- 4 HEX NUTS M16x85
A320-L7 STUD BOLT & A194- 4 HEX NUTS M20x80
A320-L7 STUD BOLT & A194- 4 HEX NUTS M30x170
A320-L7 STUD BOLT & A194- 4 HEX NUTS M24x160
A193 GR.B7 STUD BOLT & A194 Gr.2H HEX NUTS M12x70
A193 GR.B7 STUD BOLT & A194 Gr.2H HEX NUTS M16x95
A193 GR.B7 STUD BOLT & A194 Gr.2H HEX NUTS M20x100
GASKET ( PRODUCT & UTILITY ) 300#,B16.20,SPW,SS304+GRAPHITE,4.5mmTHK -25NB
GASKETS (PRODUCT & UTILITY) 300#,B16.20,SPW,SS304+GRAPHITE,4.5mmTHK-80NB
GASKET ( PRODUCT & UTILITY ) 300#,B16.20,SPW,SS304+GRAPHITE,4.5mmTHK-250NB
GASKET ( PRODUCT & UTILITY ) 300#,B16.20,SPW,SS304+GRAPHITE,4.5mmTHK- 300NB
GASKET ( PRODUCT & UTILITY ) ASME B 16.21,GRAPHITE FILLED,150# 25NB
GASKET ( FIRE WATER LINE) 150#,ASME B16.21,GRAPHITE 150NB
GASKET ( FIRE WATER LINE) 150#,ASME B16.21,GRAPHITE 100NB
GASKET ( FIRE WATER LINE) 150#,ASME B16.21,GRAPHITE 80NB
GATE VALVE ( PRODUCT & UTILITY) 800#, SW, API 602, A350 Gr.LF2 15NB
GATE VALVE ( PRODUCT & UTILITY) 800#, SW, API 602, A350 Gr.LF2 25NB
GATE VALVE ( PRODUCT & UTILITY) 800#SW,API602, ASTM A 182 Gr.F304 25NB
BALL VALVE (PRODUCT & UTILITY) 300#, BW, BS EN ISO17292, A352Gr.LCB 80NB
BALL VALVE (PRODUCT & UTILITY) 300#, FLGD,BS EN ISO17292, A352 Gr.LCB 300NB
GATE VALVE (FIRE WATER LINE) BODY : ASTM A216 GR.WCB TRIM : 8(API 600) (13CR / HF),150# 150 NB
PIPE PVC,IS4985,CLASS 5 (PN 10 Kg/cm2),PE 20NB
PIPE PVC,IS4985,CLASS 5 (PN 10 Kg/cm2),PE 32NB
90o ELL,PVC (SUITABLE FOR PN 10 Kg/cm2) 20NB
90o ELL,PVC (SUITABLE FOR PN 10 Kg/cm2) 32NB
EQ.TEE,PVC (SUITABLE FOR PN 10 Kg/cm2) 32NB
FULL CPLG,PVC (SUITABLE FOR PN 10 Kg/cm2) 32NB
RED CPLG,PVC (SUITABLE FOR PN 10 Kg/cm2) 32NB x 20NB
BALL VALVE PVC (SUITABLE FOR PN 10 Kg/cm2) 32NB
TAP (PVC) 20NB
EYE WASH AND EMERGENCY SHOWER
FABRICATION AND ERECTION OF PIPING SYSTEM
WELDING & ERECTION OF CS PIPE, A333Gr.1, SMLS 25 NB,SCH.80
WELDING & ERECTION OF CS PIPE, A333Gr.1, SMLS 80 NB,SCH.40
WELDING & ERECTION OF CS PIPE, A333Gr.1, SMLS 250 NB,SCH.40
WELDING & ERECTION OF CS PIPE, A333Gr.1, SMLS 300 NB,SCH.40
WELDING & ERECTION OF CS PIPE, API 5L Gr.B,PSL1,SMLS 25 NB, SCH.80
WELDING & ERECTION OF SS PIPE, A312 TP304, SMLS 25 NB,SCH.40S
WELDING & ERECTION OF CS,API 5L Gr.B PSL 1, ERW, BE 80NB, SCH.40
WELDING & ERECTION OF CS,API 5L Gr.B PSL 1, ERW, BE100 NB, SCH.40
WELDING & ERECTION OF CS,API 5L Gr.B PSL 1, ERW, BE150 NB, SCH.40
INSTALLATION OF VALVE 800#, SW, API 602, A350 Gr.LF2 15NB
INSTALLATION OF VALVE 800#, SW, API 602, A350 Gr.LF2 25NB
INSTALLATION OF VALVE 300#, BW,BS EN ISO17292, A352 Gr.LCB 80NB
INSTALLATION OF VALVE 300#, FLGD, API 600, A352 Gr.LCB 300NB
INSTALLATION OF VALVE 800#SW,API602, ASTM A 182 Gr.F304 25NB
INSTALLATION OF VALVE 150#, BW, A216 Gr.WCB 150NB
DISMANTLING AND TRANSPORTATION OF AUTOMATIC MARINE UNLOADING ARM ALONG WITH HYDRAULIC UNIT TO SAFE HOUSE (WITHIN 200 meters)
DISMANTLING AND TRANSPORTATIONOF MANUAL MARINE UNLOADING ARM TO Q1 BERTH
ERECTION OF MANUAL MARINE UNLOADING ARM AT Q1 BERTH.
DIMANTLING AND RELOCATION OF PRESSURE INDICATOR ASSEMBLY
DIMANTLING AND RELOCATION OF PRESSURE TRANSMITTER ASSEMBLY
DIMANTLING AND RELOCATION OF TEMPRATURE INDICATOR ASSEMBLY
DIMANTLING AND RELOCATION OF TEMPRATURE ELEMENT ASSEMBLY
DIMANTLING AND RELOCATION OF SAFETY VALVE ASSEMBLY
DIMANTLING AND RELOCATION OF STRAINER 300 NB
DIMANTLING AND RELOCATION OF BALL VALVE 300 NB
DIMANTLING AND RELOCATION OF FLOWMETER ASSEMBLY WITH MATING FLANGES GASKETS & BOLT SETS- 250NB
DIMANTLING AND RELOCATION OF CONTROL VALVE ASSEMBLY WITH MATING FLANGES GASKETS & BOLT SETS- 300NB
RADIOGRAPHIC / ULTRASONIC TEST (with material supply))
DP / MP TEST( with material supply)
STRUCTURALS FOR THE WORK (with material supply)
PAINTING (WITH MATERIAL SUPPLY)- 25NB
PAINTING (WITH MATERIAL SUPPLY)-80NB
PAINTING (WITH MATERIAL SUPPLY)-100NB
PAINTING (WITH MATERIAL SUPPLY)-150NB
STRUCTURAL PAINTING (WITH MATERIAL SUPPLY)
COLD INSULATION LINE SIZE-250NB, THK-100MM (with material supply)
COLD INSULATION LINE SIZE-300NB, THK-100MM (with material supply)
CIVIL WORKS FOR RELOCATION
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in premises of FACT at Willingdon Island and lift up to 1.5m in all kinds of soil
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 30 cm girth upto and including 60 cm girth
Clearing jungle including uprooting of rank vegetation,grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Disposal of moorum / buildingrubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 30km for all lifts, complete as per directions of Engineer in-charge. Note - Item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5cum or more.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains ,in all kinds of soil, including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed with in premises of FACT at Willingdon Island and close timbering in trenches including strutting, shoring and packing cavities wherever required and bailing out water to keep the excavated trenches suitable for concreting.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering
Supplying and filling contractor's own good quality earth to the required levels and grades to level uneven areas at site in layers of 200 mm including watering, ramming, etc complete with all leads and lifts as directed by Engineer in charge (Measurement will be given for consolidated filled volume as per initial and final levels as approved and certified by Engineer- in - charge)
Charges for conveying the surplus earth to places approximately 30 kms away and dumping at low lying places as directed by the Engineer in-charge. Note - Item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5cum or more.
Cement concrete work in 1:3:6 mix (1 Portland Pozzolana cement: 3 coarse river sand/manufactured sand: 6 20mm nominal size graded hard granite broken stones) including all charges for mixing concrete, necessary shuttering, laying,consolidating, curing, removal of shutters, cost for bailing out of water, oil, liquid mud etc. from all sources in excavated pits, trenches, etc. complete at all levels as per standard specifications and as directed by the Engineer in-charge for foundation / levelling course etc. Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004.
Supplying and grouting pockets,base plates, etc. at all levels for static equipment / structural steel supports using non-shrink grouts. Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004.
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge."(Note :- Cement content considered in this item is @ 340 kg/cum."Excess/ less cement used as per design mix is payable/ recoverable separately)- All works above plinth level up to and including floor V level (No separate payment shallbe made for positioning the precast sleepers)
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet,steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks for beam sides etc. including removal after completion /curing at all levels - foundation footings, bases of columns and walls. for mass concrete with straight sides
Providing form work to cement concrete and RCC works with necessary plywood/steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks for beam sides etc. including removal after completion /curing at all levels - Lintels, beams, plinth beams, girders,bressumers and cantilevers.
Providing form work to cement concrete and RCC works with necessary plywood/ steel sheet,steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks for beam sides etc. including removal after completion /curing at all levels - Suspended floors, roofs, landings, balconies and access platform.
Providing form work to cement concrete and RCC works withnecessary plywood/ steel sheet,steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks for beam sides etc. including removal after completion / curing at all levels - Columns, Pillars, Piers, Abutments, Posts and Struts.
Supplying , fabricating,conveying and fixing reinforcement to RCC works at all levels with high strength deformed bars Fe500D grade Thermo Mechanically Treated (TMT) bars conforming to IS 1786 including all charges for uncoiling and straightening rods, cutting rods, bending cold, placing in position and supplying & tying with black annealed tying wire of 16 gauge, etc. complete. Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004
Supplying, conveying fabrication and erection of MS singlesection members such as channels, guard rail, MS angle hand rails verticals, etc. with fixtures such as end stops, Supplying, conveying fabrication and erection of MS single clamps, bolts and nuts etc. including charges for cutting, splicing, drilling holes as required, fixing to lines and levels and cleaning thoroughly with power tools and painting with two coats of red oxide zinc chromate primer ( one shop coat and one coat after fixing / erection) Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004, Refer painting specs for applying priming coats
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete with Electric resistance or induction butt welded tubes
Supplying and fixing MS inserts of all types fabricated out of MS plates, angles, channels, flats, rods, fabricated pieces, etc. in RCC / masonry works at all levels including all charges for cutting, welding, fixing to lines and levels and painting the exposed surfaces with two coats of chemical resistant enamel paint of approved quality and colour over two coats of red oxide zinc chromate primer, etc. complete Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004, Refer painting specs for applying priming coats
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete to all lines and levels and applying petroleum jelly / grease after erection on exposed surface of bolts to prevent corrosion
Painting of structural steel work over priming coats (paid with the steel supply item) as follows: a) One intermediate coat of Micaceous Iron Oxide epoxy paint of 70-micron DFT b) One coat of two pack polyamide cured epoxy finish paint of 40-microns DFT c) One coat of aliphatic acrylic polyurethane finish paint of 40-microns DFT Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004, Refer painting specs
Plastering with cement plaster of mix 1:4 (1 cement: 4 fine sand), for an average thickness of 12mm, one coat, floated hard and trowelled smooth at all levels including necessary scaffolding and curing etc in interior walls. Approved make of materials are furnished in Specific requirements of work 32669-12-DA-004
Anchoring rebar after placing in position and inserting into the holes drilled and grouted using the grout manufactured by HILTI or equivalent make for beams as directed by the engineer in-charge. Rate shall include supply of all materials (except reinforcement rods), conveyance, all charges for cleaning the surface, drilling holes,fixing rebar, grouting etc, at all levels by HILTI authorised personnel rods will be paid in separate item) for 16mm / 20mm dia bars with RE-500 V3 adhesive
INSTRUMENTATION SYSTEMS
A-Control Valve accessories including Tubing The scope includes the laying of individual cables, ganding and termination at both the instrument and Junction box end etc of the following instruments/ instrument assemblies including the supply and erection of necessary instrument air connection/ tubing and connectors if required. The mechanical relocation of instruments and valve is covered under piping SOR.
B-Turbine Type Flow meter The scope includes the laying of individual cables, ganding and termination at both the instrument and Junction box end etc of the following instruments/ instrument assemblies including the supply and erection of necessary instrument air connection / tubing and connectors if required. The mechanical relocation of instruments and valve is covered under piping SOR.
C-Ambient Ammona Detectors The scope includes the laying of individual cables, ganding and termination at both the instrument and Junction box end etc of the following instruments/ instrument assemblies including the supply and erection of necessary instrument air connection /tubing and connectors if required. The mechanical relocation of instruments and valve is covered under piping SOR.
D-Temperature Element (RTD) The scope includes the laying of individual cables, ganding and termination at both the instrument and Junction box end etc of the following instruments/ instrument assemblies including the supply and erection of necessary instrument air connection/ tubing and connectors if required. The mechanical relocation of instruments and valve is covered under piping SOR.
E-Pressure transmitter The scope includes the laying of individual cables, ganding and termination at both the instrument and Junction box end etc of the following instruments/ instrument assemblies including the supply and erection of necessary instrument air connection/ tubing and connectors if required. The mechanical relocation of instruments and valve is covered under piping SOR.
"Supply of junction box (at Q1 berth end) with cable glands and plug- (Suitable for 12 Pair multicore), Weatherproof IP65, Flame Proof Exd, material: Diecast Aluminium,Terminals: 30 nos, Earth connection: 1 no inside and 2 no outside, Cable entry: bottom or side Cable glands and plugs - Individual cable enrty- 1/2"" NPT(12 Nos) - 12 Nos of Cable gland, Spare-12 nos of cable gland +3 Nos Plug in loose Multi pair cables- 1"" (typical) (2 Nos,)- Cable glands- 1nos, Plug- 1 No. Cable glands/ with plugs- SS316 Double compression type suitable for Armored cables, PVC shrouds also to be installed. (Necessary Civil work and structural work also to be included in scope of work)"
"Erection of junction box (at Q1 berth end) with cable glands and plug- (Suitable for 12 Pair multicore), Weatherproof IP65, Flame Proof Exd, material: Diecast Aluminium,Terminals: 30 nos, Earth connection: 1 no inside and 2 no outside, Cable entry: bottom or side Cable glands and plugs - Individual cable enrty- 1/2"" NPT(12 Nos) - 12 Nos of Cable gland, Spare-12 nos of cable gland +3 Nos Plug in loose Multi pair cables- 1"" (typical) (2 Nos,)- Cable glands- 1nos, Plug- 1 No. Cable glands/ with plugs- SS316 Double compression type suitable for Armored cables, PVC shrouds also to be installed.(Necessary Civil work andm structural work also to be included in scope of work)"
"Supply of Intermediate junctionbox (At SCB area tie in point) with cable glands and plug- (Suitable for 12 Pair multicore), Weatherproof IP65, Flame Proof Exd, material: Diecast Aluminium,Terminals: 30 nos, Earth connection: 1 no inside and 2 no outside. Cable entry: bottom or side Cable glands and plugs - Individual cable entry- 1/2"" NPT (12 nos)- 12 nos plugged +12 Nos Cable gland in loose Multi pair cables- 1"" (typical) (2 Nos,)- Cable glands- 2nos, Cable glands/ with plugs- SS316 Double compression type suitable for Armored cables, PVC shrouds also to be installed. (Necessary Civil work and structural work also to be included in scope of work). Erection includes disconnecting of the existing 12 Pair multicore cable from Old Junction box end, roll and tie the cable from overhead cable tray Approximately 30 mtr) and terminate it at the Intermediate junction box."
"Erection of Intermediate junction box (At SCB area tie in point) with cable glands and plug- (Suitable for 12 Pair multicore), Weatherproof IP65, Flame Proof Exd, material:Diecast Aluminium,Terminals: 30 nos, Earth connection: 1 no inside and 2 no outside. Cable entry: bottom or side Cable glands and plugs - Individual cable entry- 1/2"" NPT (12 nos)- 12 nos plugged +12 Nos Cable gland in loose Multi pair cables- 1"" (typical) (2 Nos,)- Cable glands- 2nos,Cable glands/ with plugs- SS316 Double compression type suitable for Armored cables, PVC shrouds also to be installed. (Necessary Civil work and structural work also to be included in scope of work). Erection includes disconnecting of the existing 12 Pair multicore cable from Old Junction box end, roll and tie the cable from overhead cable tray (Approximately 30 mtr) and terminate it at the Intermediate junction box."
Supply of all required type of individual cables(1Pair, 1 Triad, 2 Pair) between instrument and junction box,1.5 sq mm FRLS Cable- Screened and armoured, 600 voltage class, Extruded PVC Type C, ST2, Conductor: ATC, 7 stranded, Shield : Aluminium backed mylar, 25% overlapped with helical wrapping, Drain wire: 20 AWG tinned copper with 7 strands, Armour: 1.4 sq mm galvanised steel round wire, Binder: Non hygroscopic, 50% overlapped with helical wrapping, Colour: Sheath- Black, Core1-White, Core2- Black, As per standard IS1554/5831
Erection of all required type of individual cables(1Pair, 1 Triad, 2 Pair) between instrument and junction box,1.5 sq mm FRLS Cable- Screened and armoured, 600 voltage class, Extruded PVC Type C, ST2, Conductor: ATC, 7 stranded, Shield : Aluminium backed mylar, 25% overlapped with helical wrapping, Drain wire: 20 AWG tinned copper with 7 strands, Armour: 1.4 sq mm galvanised steel round wire, Binder: Non hygroscopic, 50% overlapped with helical wrapping, Colour: Sheath- Black, Core1-White, Core2- Black, As per standard: IS1554/5831
Supply of 12 Pair 1 sq mm FRLS Cable(Approximately 280m)- Individual & overall screened and armoured, 600 voltage class,Extruded PVC Type C, ST2, Conductor: Annealed tinned copper, 7 stranded, Shield : Aluminium backed mylar, 25% overlapped with helical wrapping, Drain wire: 20 AWG tinned copper with 7 strands, Armour: 1.4 sq mm galvanised steel round wire, Binder: Non hygroscopic, 50% overlapped with helical wrapping, Colour: Sheath- Black, Core1-White, Core2- Black, As per standard IS1554/5831
Erection of 12 Pair 1 sq mm FRLS Cable(Approximately 280m)- Individual & overall screened and armoured, 600 voltage class, Extruded PVC Type C, ST2, Conductor: Annealed tinnedcopper, 7 stranded, Shield : Aluminium backed mylar, 25% overlapped with helical wrapping, Drain wire: 20 AWG tinned copper with 7 strands, Armour: 1.4 sq mm galvanised steel round wire, Binder: Non hygroscopic, 50% overlapped with helical wrapping, Colour: Sheath- Black, Core1-White, Core2- Black, As per standard IS1554/5831
Supply of Cable Trays- FRP Cable tray, Perforated type, minimum Thickness 2.5mm, with cover, coupler plates, fastening ties etc, width-minimum 50mm, . Supported at every 2 mtr horizontally. Necessary structural also shall be considered in scope of supply and erection.
Erection of Cable Trays- FRP Cable tray, Perforated type, minimum Thickness 2.5mm, with cover, coupler plates, fastening ties etc, width-minimum 50mm, .Supported at every 2 mtr horizontally. Necessary structural also shall be considered in scope of supply and erection.
Supply of structural steel includes cable tray support (Structuaral support at every 2 Meter interval), Junction boxes mounting, control valve accessories mounting and instruments mounting.)
Erection of structural steel includes cable tray support (Structuaral support at every 2 Meter interval), Junction boxes mounting, control valve accessories mounting and instruments mounting.)
Dismantling of Existing instrument/ junction box related cables and cable trays, related structural steel etc and transporting of the same to authorised location as per Engineer in charge instruction and handing over to Client.
Integration of the instruments from the reloacated area to control room including hookup to junction boxes, Loop testing etc
INSTRUMENT ENGINEER CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
INSTRUMENT TECHNICIAN CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft
SUPERVISOR CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
ELECTRICIAN CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
FITTER CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
WELDER CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
RIGGER CHARGE Schedule of labour charge for commissioning & start up for following personnel- per day (8 hour shft)
DELTA CONSTRUCTIONS
Amity Projects and Construction
DEEPAK ENGINEERING WORKS
S K BOILERS PVT LTD
Bidder Name
DELTA CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .