SPECIAL REPAIR TO BLDG NO. T-21 AT BADRINATH PARAGAMAN AND PROVN OF COVERED PATHWAY AT JOSHIMATH AND PROVN OF DRAINAGE SYSTEM OF COOK HOUSE AND STAIRS FOR GUEST ROOM AT AULI UNDER GE 871 EWS
2022_MES_531171_1
8684/E8
Open Tender
Civil Works
Item Rate
180 days
Joshimath and Auli
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹71,000
Yes
5 Sept 2022
16 Jun 2022
3 Aug 2022
16 Jun 2022
27 Jul 2022
30 Jun 2022
Amount
Dismantling plain corrugated steel sheeting any gauge thickness including Nainital and similar pattern complete all as specified and directed.
Dismantling of wall and ceiling board any thickness including cover fillets complete all as specified and directed.
Dismantling of frame work timber scantling 40 Sq cm and over in section in any position complete all as specified and directed.
Dismantling of frame work timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
Taking down chowkat with shutters (without taking off shutter ) area exc. 1.5 sqm but n exc. 4 sqm each complete all as specified and directed.
Taking down door/window shutter/cupboard shutter with frame (without taking off shutters from the frame) area up to1.5 sqm each complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thick (below or above ground level) etc complete all as specifed and directed.
Demolition of Concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Demolition of concrete block walling, stone masonary built in cement mortar including all quoins archas pillars etc and pre-cast block walling etc complete all as specifed and directed.
Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed.
Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and as directed.
Dismantling water tank and removing to store exeeding 250 but n.exc 500 ltrs complete all as specifed and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and directed..
Dismantling of 150 mm dia CI pipes pipe jointed in cement mortar and taking out of trenches if required complete all as specified and directed.
Surface excavation n.exc 30cm deep fand averging 15 Cm deep and getting out in hard/dense soil Complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in harde/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm,watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm.complete all as specified and directed.
Removing excavated material soil nexc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified.
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for plain cement concrete 1:4:8 type D 2 , (Using 40mm graded stone aggregate) in foundation etc complete all as specified and directed.
M&L for 75 mm thick cement concrete type D-2,1:4:8(40mm graded stone aggregate) as in sub base complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-0 (Using 12.50mm graded stone agg) 25 mm thick in flooring finished even & smooth without using extra cement complete all as specifed and directed.
M&L Cement concrete 1:2:4, type B-1(using 20mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
M&L Extra for forming 40 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L Plain cement concrete 1:3:6 type C-1(using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F for ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979 grade Yst 240 including fabrication and erection and fixed in position complete all as specified and directed.
S&F for rolled mild steel section in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W (Gde E-250,quality- A)complete all as specified and directed.
S&F for 11 to 15 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long complete all as specified and directed.
S&F for Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment
S&F for MS Tube as in post, columns complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade Yst-240 including fabrication,erection and fixing in position complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 12 mm dia exc. 22.5 cm long but not exc 30 cm long complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 10 mm dia not exc 5cm long complete all as specified and as directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed.
M&L for RCC M-25 design mix( using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 design mix( using 20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in chajjas complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, finshed flat rough finished surfaces etc.complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, finshed flat rough finished surfaces etc.complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges, finshed flat rough finished surfaces etc.complete all as specified and directed. complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto- as per Item No. 43 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for precast cement concrete type C1, 1:3:6 (using 20 mm graded crushed stone aggregate as in solid building blocks, exc. 10 cm in width and setting in CM (1:6) complete all as specified and directed.
M&L for precast cement concrete type C1, 1:3:6 (using 20 mm graded crushed stone aggregate as in solid building blocks,of 10 cm thick and setting in CM (1:4) complete all as specified and directed.
M&L for Providing precast cement concrete type 1:2:4 type B-1, (20 mm graded aggregate) as in landing, cover slab (for manholes etc) chullah woods, chajjas, water trough mangers, shelves, and similar articles with plain faces and steeing in cement mortar 1:4 complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channel and drain complete all as specified and directed.
Extra for forming fair finished drain and channel 30 cm inner grith in cement concrete using extra cement in forms mould mitred/stopped ends complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement in internal surfaces complete all as specified and directed.
M&L rendering 15 mm thick on other than fair faces of brick work or concrete surfaces with CM (1:6) finished even and smooth without using extra cement in external surfaces complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty complete all as specified and as directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of suitable primer complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in leveling course ,finished surfaces even and rough to receive floor finish complete all as specifed and as directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed bed of 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specifed and directed.
M&L for Non skid ceramic coloured tiles (300x300)x7 mm thick in floors etc. set and jointed in neat cemenbt slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and as directed.
M&L for glazed ceramic coloured tiles of size 350x 250x 7 mm/ 450X 350X 7mm thick thick over and ncluding 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed.complete
M&L for Prepolished Chequered cement concrete tiles 25cm x 25cm/ 30cmx30 cm x 25mm thick, set, jointed and pointed in neat cement slurry in floor with grey cement and no pigment over Screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying in floors, tiles complete all as specified and directed.
M&L for Prepolished chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed and in neat cement slurry in floor with grey cement and pigment and including over screed bed or bedding layer of mortar 20 mm thick laying floor finished in cement mortor 1:6 complete all as specified and directed.
S&F for frame work only for suspended false ceiling, GI exposed ceiling suspension system of grid size 600mm x 600mm with main runner 38mmx24mm, cross tee 29mmx24mm and wall angle 24mmx24mm. to form a grid of GI system duly suspended with 4mm dia GI/MS bar hanger fixing with steel dash fastner or iron purlins from the roof with adjustment clip providing position for light fixture etc all as specified and as directed.
S&F for false ceiling of Everest designer boards of size 595 mm x 595 mm x 4 mm thick fixed on GI snap grid, complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 (using 20 mm graded crushed stone aggregates) as in plinth protection; 75 mm thick; finished even and smooth without using extra cement complete all as specified and directed.
S&F for Pressed steel frames for doors with one or more rebates (Size of frame 125x60mm) including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, complete all as specified and directed.
S&F for Pressed steel frames for doors with one or more rebates (Size of frame 105x60mm) including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, complete all as specified and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F for 35mm thick IInd class hard wood glazed and skelton door shutter divided into square, open rebated and prepared to receive glass/gauge etc (without sash barsi) edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass/gauge etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.20 (a) complete all as specified and as directed.
S&F for Solid PVC door frame of size 50 mmx47 mm made out of 5 mm plain colour PVC sheet re-inforced with M.S square tube, suppyling and fixing in opening as per specification and drg complete all as specified and directed..
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour of PVC sheet for top rail lock rail and bottom rail, on either side & gap insert for top rail bottom rail panelling of plain colour PVC sheets to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppying and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F for powder coated aluminum section for making frame and shutters of doors, windows, partition wall, shutters etc including styles & rails with standard anodized aluminum section, with one or more rebates including aluminium snap beading complete all as specified and as directed (Glazing, rubber beading,hinges etc shall be measured and paid separately)
S&F Aluminium anodised DG 102 "DECO" grill of size 100mm x 10mm x7mm thick, approved design for windows / ventilators with and including F/U channel, ,complete all as specified and as directed by Engineer-n-Charge.
S&F for 4.8mm thick sheet glass of ordinary quality and glazing fixed to aluminium shutters in square n.exc 0.5Sqm in each pane complete all as specified and directed.
S&F for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specifed and as directed.
S&F for butt hinges medium weight cold rolled mild steel 100mm complete all as specifed and directed.
S&F for 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long anodised extruded aluminium alloy handles, fabricated type. complete all as specified and directed.
S&F for 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F for floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), fixed as in repair complete all as specified and directed.
S&F in repair for 20 mm dia chromium plated pipes for curtain rods complete all as specified and directed.
S&F in repair for Chromium plated brackets and knobs for curtain rods complete all as specified and directed.
M&L for preparation of new steel surfaces of any description,over 10cm in width or girth, not otherwise describedand applying two coat of synthetic enamel paint on roof over a coat of red oxide primer complete all as per specified and directed.
M&L for preparation of old painted steel surfaces of any description,over 10cm in width or girth, not otherwise describedand applying two coat of synthetic enamel paint on roof over a coat of red oxide primer complete all as per specified and directed.
M&L for Preparation of new wooden surface of any description over 10cm width or girth applying two coat of synthetic enamel paint over a coat of pink primer complete all as specifed and directed.
S&F 15mm bore GI tubing medium grade with all fitting fixed to wall and ceiling or laid in floor complete all as specifed and directed.
S&F for 20mm bore GI tubing medium grade with all fitting fixed to wall and ceiling or laid in floor complete all as specifed and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) including making good complete all as specifed and directed.
S&F in repair plastic water closet seat, black and white closed pattern with flat bottom and cover and mild steel chromium plated plated or aluminium hinging device complete all as specifed and directed.
S&F for 15mm dia CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed .
S&F for 15mm bore Health faucet with CP felxible pipe of 90cm long incl necessary fittings complete all as specified and directed .
S&F in repair Vitreous china wash hand basin (550X400mm) white, flat back excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specifed and as directed.
S&F in repair 32mm bore waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and othter end fixed complete all as specifed and as directed.
S&F in repair for 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float , flush pipe and handle including brackets and fixed complete all as specifed and as directed.
S&F in repair PVC connection 15mm dia and 600mm long complete all as specifed and as directed.
S&F in repair PVC waste pipe 32mm dia complete all as specifed and as directed.
S&F in repair 15 mm bib tap CP fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrules and complete all as specifed and as directed.
S&F in repair 15mm bore chromium plated brass angle cock screwed for iron pipe or union and fixed complete all as specifed and as directed.
S&F in repair for 15mm bore brass chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall complete all as specifed and directed.
S&F in repair for 15mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall complete all as specifed and as directed.
S&F for rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and as directed.
S&F in repair CP towel rail with hook 600mm long complete all as specifed and as directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in concrete bed to 150 mm dia pipes including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed.
M&L for 150 mm dia CI pipe (sand cast) soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified.
S&F for 110mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor including taking downcomplete all as specifed and directed.
M&L for 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Cutting into existing manholes for 110 mm dia pipe,connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, light fitting etc removing materials to store for keeping in safe custody for taking credit or reuse serviceable fittings/fixtures and making good the disturbed surfaces of wall/floors.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No 108 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch.
All as per item No 108 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches
All as per item No 108 here in before but one socket out let 15/16 Amps controlled by one switch on independent board and wiring with 2.5sqmm cable.
S&F switch piano flush type single pole , 5/6 Amps one way, 230 volts, all as directed .
S&F switch piano flush type single pole , 15/16 Amps one way, 230 volts, all as directed .
S& F socket outlet 5/6 Amps flush type piano 5 pin 230 volts all as directed.
S&F socket outlet 15/16 Amps multipurpose 3 pin 230 V all as directed by Eng-in- charge.
S&F ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals.
Supply and fixing in replacement of electrical bell (Ding dong type) AC, 230 Volt .
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed.
Supply & Fixing lamp holder , insulated body ,with back plate suitable for batten fitting complete all as specified and directed.
S&F 9 Watt LED bulb. cool day light, 230/240V AC supply all as specified and as directed by the Engineer-in-charge.
S&F in replacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one No MCB, SP, 20 Amps, 230 Volts, 10KA 'C' series complete all as specified and directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F surface and wall mounted LED tube light fitting mirror type with high out put diffuser 2 feet ,10 watt 220 volt AC decorative type with driver holder and LED lamp/rod including connecting up with three core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F in replacement building security light fitting complete with 35 watt LED type IP 66 pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution etc complete fixed bracket made out by GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces.
S&F in replacement of unserviceable MCB DB sheet metal enclosure Single pole and neutral 230 V with 200 Amps standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mounting type double door factory fabricate complete without MCB and with encosure blank plates for unused way suitable for 8 way flush in wall complete.
S & F MCB SPN 40 Amps 240 Volts C, series complete all as specified and directed.
S & F MCB 6 to 40 Amps SP, 240 Volt C, series complete all as specified and directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for in replacement sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down serviceable Exhaust fan any size capacity and refixing same location with Hole fastener Nut & Bolts after complete work of building complete all as specified and directed.
Taking down serviceable Electric storage water geyser 25 Ltrs capacity and refixing same location with PVC connection pipe 15 mm dia heavy duty approx length 450/600mm long -02 Nos, Hole fastener Nut & Bolts made of iron approx length 6 cm long -04 Nos after complete work of building complete all as specified and directed.
Supply and fixing in replacement, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core all as per IS , specified & directed. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule )
Supply and fix in replacement of light grade Galvanised mild steel pipe 40mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ).
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
ms triveni nirman
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .