Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.0 L+₹6.0 L (18.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹39.5 L+₹6.6 L (20.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹48.8 L+₹15.8 L (48.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | Not Admitted-Fee OFFICE SPACE NO 95 10TH CROSS STREET SENTHIL NAGAR KOLATHUR CHENNAI 600099 | CHENNAI | TAMIL NADU | 600099 | - | Not Admitted-Fee RFP conditions not met |
Tender Value
Refer Docs
EMD Value
₹84,800
Closing Date
9 Feb 2022, 4:00 pmClosed
DGM PRODUCTION AND ESE
MFL MANALI CHENNAI
Construction of New Control Room for Utility Boiler II at MFL
2022_MFL_669376_1
ESER/ENGG/CONTROL ROOM/090222/002 Dt. 20/01/2022
Open Tender
Miscellaneous Services
Works
365 days
MFL MANALI CHENNAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹84,800
Yes
11 Apr 2022
20 Jan 2022
10 Feb 2022
20 Jan 2022
9 Feb 2022
20 Jan 2022
Dismantling of Old RCC & PCC Floor, Slab and Footings by JCB, Breaker and manually. Disposing the same to the designated area with in 500M inside MFL as per MFL Engineers' Instruction.
Excavation of all types of soil in Foundation to a maximum depth of 2M by JCB & Manually & Disposing the same to the designated area with in 500M inside MFL as per MFL Engineers' Instruction (Including Back Filling).
Supply & Laying PCC of Grade M15 in foundation, plinth, column and floors etc., to a height of 150mm.
Supply and installation of FE500 Grade TMT Bars of sizes ranging from 8 mm to 20 mm diameter along with 22 gauge MS Binding wire in Foundation, Plinth, Column, Beam, Staircase, etc.
Supply & Laying RCC of Grade M25 for super structure works including Foundation, Columns, Beams, Lintels, Stair Cases, Roof etc., inclusive of scaffolding.
Construction of Brick/Block Masonry wall of 200 mm thick in cement mortar at 1:3 including of stairs and scaffolding.
Providing 12mm thick cement and sand plasters 1:4 for internal plastering over the bridge/block work walls, ceiling inclusive of scaffolding.
Providing 20mm thick cement and sand plasters 1:4 for external plastering over the bridge/block work walls inclusive of scaffolding.
Shuttering - Providing, installing & removal after completion of Shuttering in foundation and super structure.
Supply and apply of bituminous black paint on all the pedestals, foundations, plinths whichever lies below ground level.
Providing and applying 3 coats (1 coat Primer + 2 coat Paint) with all levels with cement paint (ACE or equivalent) on the internal surfaces including scaffolding, surface preparation, etc.,
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying 3 coats (1 coat Primer + 2 coat Paint) with all levels with exterior weather shield paint (Snowcem or equivalent) on the external surfaces including scaffolding, surface preparation, curing etc.,
Providing and fixing UPVC windows (1.2 x 1.2 m - 2 nos.), Ventilator (0.6 x 0.6 m - 2 nos) (sliding type) of glass panels 6mm thick with frame and required fittings.
Providing and fixing UPVC Door of size 2.1 x 1.5 m - 1 no of glass panels 6mm thick with frame and required fittings.
Supplying and filling Crusher Sand upto any depth under floors around foundations, plinths etc., in layers not exceeding 150 mm thickness.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long drywall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of drywall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. 12.5 mm thick tapered edge gypsum moisture resistant board.
providing and laying anti-skid vitrified floor tiles 0.6 x 0.6 m with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand). Preferred Brands : KAG/Johnson/Kajaria/Anuj
Supply/ Installation/Construction of western toilet complete set with trap/ pond/ sewer piping upto the exterior with in battery limit, as per drawing, along with 2 urinal stations with 2'*1' non-metallic louver accommodating 150mm exhaust fan in it. (Include Supply and installation of 2 nos of PVC bathroom doors & partition in scope). Brand: Parryware/Johnson/Hindustan /Equivalent - Colour : White. 2 Urinal, 1 Wash basin, 1 EWC including all SS taps, pipes & fittings (As per the Institution of EIC) S.I.T.C of UPVC concealed plumbing for the above toilet, urinals, wash basin, along with water tap set 3 nos, health faucet 01 no., 6 hook SS dress hanger 01 no., SS towel ring 01., acrylic /PVC soap tray 01 no. along with required quantity of angle cocks / bib cocks / isolation ball valves etc.
Providing and laying rectified Glazed Ceramic anti-skid floor tiles of size 300x300 mm or more, of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, mixed with 2% integral water proofing compound laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. Preferred Brands : KAG/Johnson/Kajaria/Anuj
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622, of approved make, in all colours, shades except burgundy, bottle green, black of size 0.3 x 0.6 m as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Preferred Brands : KAG/Johnson/Kajaria/Anuj
Providing and laying ceramic roof tiles (as per approved pattern 10 - 12 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. Preferred Brands : KAG/Johnson/Kajaria/Anuj
S.I.T.C of sewer and drainage system with UPVC pipes and fittings for the above toilet, urinals, wash basin, along with traps/gulley traps/chajjas. Integrating the urinal drain, wash basin drain, tap water wash drain etc. upto the exterior of the battery limit and running the sewer line up to distance 100 meters from battery limit and connecting it with the existing line. Include excavation/ civil and other required additional works in scope.
S.I.T.C Incomer main DB box with 63Amps MCB 01 No., 63 Amps ELCB 01 No., 20 Amps MCB 5 No., 16 Amps MCB 05 No., 10 Amps MCB 05 Nos. Provide and install 15 lighting points, 10 fan points, 5 Amps plug points with switch 5 nos. consisting of 3 per plug socket with switch/set, 15 Amps plug points with switch 3 nos. consisting of 2 per plug socket with switch/set along with required fittings, pipings, casings, clamps, fasteners. With wires and cables of sufficient quantity and capacity. (Copper wires of FRLS grade to be used).
SRT Engineering Service
Dassara Constructions
Bhagyalaxmi Projects Engineers And Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .