Assistant Engineer
Office of the Assistant Engineer, LSGD Section, Anthoor Municipality, KUC(PO), Dharmasala PIN 670567
Electrification of GAS Crematorium
2021_LSGD_414045_1
E1-2965/20
Open Tender
Electrical Works
Item Rate
120 days
Anthoor Municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,700
Yes
₹21,250
Yes
9 Mar 2021
10 Feb 2021
23 Feb 2021
10 Feb 2021
20 Feb 2021
10 Feb 2021
90 days
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FR wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular typeROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control light point with 6A, 3 plate ceiling rose(LP)
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Supply and fixing Plug points with 6 A, 3 pin shutter socket controlled by 6 A switch in independent positions.(Including wall fan )
Supply and fixing Plug points with 6/16 A universal socket controlled by 16 A switch .
Supply and fixing 2-Nos 6A modular type 3 pin plug socket controlled with 2 Nos modular type 6 A switches with box .
Supply, Conveyance, Installation and Testing of 36 W patties Tube light fitting with electronic choke Havells or similar make of Philips, on ceiling and giving connection.
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder without shade and giving connection including 8/9 W LED lamp
Supply and fixing brass lined skirt type, bakelite Pendent holder without shade and giving connection including 10W LED bulb
Supply and fixing cast aluminium elliptical shaped bulk head fitting with front clear glass and mesh guard suitable for 9W LED to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
Supply, conveyance, installation, testing and commissioning of 25/30W or nearest LED street light fittings (IP 65) of syska/philips or similar make complete with all accessories and fixing on GI pipe bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
Supply and Providing GI bracket for Street light
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
1200 mm sweep - 5 star rated
Charges for cutting holes suitable for accommodating Turbo Ventilator of sizes up to 22'' Diameter including leak proof compound as required.
Supply, conveyance, installation, testing and commissioning of the following sizes of Turbo Ventilator with base plate suitable for fixing in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required.
22'' Diameter Turbo Ventilator (Stainless steel/alloy of Aluminium) with base plate.
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
300/ 305 mm, single phase light duty exhaust fan in metal frame
Supply, conveyance, installation, testing and commissioning wall mounting fan of the following sizes using mounting brackets supplied along with the fan and giving connection with existing wire
400 mm sweep or nearest size
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories in recess including making good the damages etc as required.
1.50 sq mm 3 run (For CPB)
25 mm dia medium gauge
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
1.50 sq mm 3 run
2.50 sq.mm 2 Run + 1.50 sq.mm 1 Run (For PP)
6.00 sqmm 4 run+4.00 sq mm 2 run (For 3Ø DB)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
40 A four pole mini break isolator
40 A, 4 pole, 100 mA RCCB
6-32A SP MCB (B/C curve)
6 A to 25 A, 10 kA, TP MCB (C curve)
Supply and providing 63 A, AC 23 A, 4 pole on-load COS in SS enclosure
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm tinned copper strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm copper strip tinned at the points of contacts
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
3.15 mm copper conductor (10 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
3.15 mm (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
25 x 3mm brass bolt & nut
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
Supply and fixing the following accessories in the existing meter board and giving connections etc.
32 A, TPN switch fuse unit with ISI marked HRC fuses
32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
32 A, DIN type fuse link of size 00
32 A, 415 V, DIN type fuse base.
Paert II - Providing L/A System
Supply and clamping GI strips of size 25x6mm on surface of wall/parapet using GI clamps/insulator fabricated from GI strips of size noted along with spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required for horizontal run 25x3mm flat clamped with 25x3mm clamps along patapet.
Supply and clamping GI strips of size 25x6mm in trench of depth not less than 60cm with protective covering using country burnt bricks for inter connecting the earth rods for lightning conductor.
Supply and clamping25 x 6 mm GI strip on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for vertical run).
Riveting, sweating and soldering of one GI tape with another GI tape using 2nos. 6mm dia GI bolt and nut joints including tinning/drilling holes as required.
Providing and fixing testing joint made of 2 no. tin copper strips of size 25X3 mm 150 mm long provided on either side of the conductors with 4 Nos of tinned brass bolts , nuts check nuts and spring washers etc. complete as required (for lightning conductors including inter connection).
Supply and providing Surge Protection device SPD Combination arrestor V50, 3Pole+NPE320V as IEC 61643-11 and EN 61643-11 with current discharging capacity of 12.5kA(10/350)per pole and upto 50kA(10/350) in total of OBO make or equivalent make of DHEN, Citel etc in Suitable Enclosure or in the main panel/VDB according to convenience and giving connections as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm tinned copper strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm copper strip tinned at the points of contacts
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
3.15 mm copper conductor (10 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
3.15 mm (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
25 x 3mm brass bolt & nut
Supply, threading, laying and joing of 40mm dia 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to the earth leads.
Supply, conveyance erecting, testing & commissioning of simple rod lightning arrestor electrode of Copper tube of 25mm dia, 1.5m height with all accessories on top of the roof and connecting to proposed earthing system.
Part III Providing DG
Kirloskar/Leyland/Cummins/Kholler/Cooper make Deisel engine coupled with15kVA, 415V, 50Hz, 0.8PF brushless alternator of Kirloskar or equivalent make with control panel.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
4 core 10 sq mm
Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required.
Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.
Supply and fixing of 50/75MM dia heavy guage MS exhaust pipe line for 15 KVA DG horizondal/vertical position up to hight of 4M Building using mechanical support, safety mechanisms like chain pully, and scafolding as per site condition including painting with boiler paint, clamping, providing reducing nipple etc
Thermel insulation of exhaust line with glass wool cladding with 26 SWG aluminium sheet as required and per standard practice
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing plate earthing as per IS 3043 with 300x300x6.00 mm copper earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required .
300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm tinned copper strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm copper strip tinned at the points of contacts
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
3.15 mm copper conductor (10 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
3.15 mm (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
25 x 3mm brass bolt & nut
Charges for errection, commissioning and placing on suitable foundation of 15kVA DG set with accoustic enclosure as per IE rules and inspectorate standards.
Preperation of electrical scheme and submission to electrical inspectorate, arranging inspection and obtaining approval /energisation certificate from electrical inspectorate
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_588159.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .