Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹3.4 L (11.8%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹32.1 L+₹3.6 L (12.6%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹32.2 L+₹3.7 L (12.9%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹32.8 L+₹4.3 L (14.9%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
24 Sept 2019, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
PROVISION OF VARIOUS MINOR WORKS AT DIFFERENT LOCATIONS INCLUDING SPECIAL REPAIR REPLACEMENT OF UN SERVICABLE LOW TENSION UNDER GROUND CABLE WITH CONNECTED ITEMS AT CERTAIN LOCATIONS AND UPS POWER SUPPLY AGAINST BER TO CERTAIN BUILDINGS UNDER GE I
2019_MES_282910_1
8404
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹58,000
Yes
18 Jan 2020
17 Sept 2019
26 Sept 2019
17 Sept 2019
24 Sept 2019
19 Sept 2019
17 Sept 2019 - 18 Sept 2019
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
Cutting chases in brick wall, pinning in, making good to facing where reqd and pointing in CM 1:3 to ends of edges of landing, steps, cills, lintels etc and cutting chases exceeding 10 cm but not exceeding 20 cm girth. for concealed water tubing and making good cutting as per its original specfication complete al as directed.
M&L river sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable. Note: Thickness after punning shall be measured for payment.
M & L for PCC 1:4:8, type D2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
Taking up old existing PCC cable cover complete.
Laying only PCC cable covers for protection of UG cable in trenches , cable cover obtained from Item Sl No. 7 here-in-above.
Supply and laying un-reinforced precast cement concrete cable cover, class LV, type 1, flat, size 250x150x40 mm for protection of underground cable in trenches complete all as directed. Make: Mehtab tiles / Ultra tiles / Sirex / Scorpio or any ISI marked tiles as approved by GE.
Supply and lay 40 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, laid in trenches as cable protection with all fittings complete all as specified.
Supply and lay 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, laid in trenches as cable protection with all fittings complete all as specified.
Taking down unservicable calbe laid in any description and Supply, lay and testing new XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 cross-sectional area 240 Sqmm, 3.5 core and laid in trenches / pipe / ducts complete all as specified.
All as per item No. 12.00 here in above, but cross-sectional area 185 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 120 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 70 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 50 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 35 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 25 Sqmm, 3.5 core.
All as per item No. 12.00 here in above, but cross-sectional area 16 Sqmm, 4 core.
All as per item No. 12.00 here in above, but cross-sectional area 10 Sqmm, 2 core.
Taking down rusted / worn out GI Pipe any dia form excavated trench and Supply and lay in trenches new GI Pipe 100 mm bore light grade (ISI Marked) with necessary fittings such as bend, tee, elbow etc., and testing on completion complete all as specified & directed..
All same as per item No 21 here-in above but 80 mm bore of pipe -do-
All same as per item No 21 here-in above but 50 mm bore of pipe -do-
All same as per item No 22 here-in above but 40 mm bore of pipe -do- (Note for item No 21 to 24 : Quoted rate is deemed to be inclusive of earth work & excavation complete)
Supply and laying in trenches 50 mm bore galvanised steel water tubing medium grade with fittings such as bends, tees, elbows, nipples, unions, short pieces etc making necessary connection and testing on completion all as specified and directed . (Note for item No 25 : Excavation & earth work measured and paid seperately)
S & F 10 KVA true On-line Double Conversion Type UPS system consisting of following:- - Input : 300-450 VAC, 3P4W, 50 Hz + 3Hz Rectifier cum Battery Charger - Output : 230 VAC, + 1%, 1P2W, 50 Hz + 1% IGBT inverter - Inbuilt Galvanic Isolation Transformer at Inverter output side - Waveform : Sinewave - Output voltage Harmonic distortion : < 2% for Linear Load and < 5% for Non Linear Load - Transient Response : Less than + 5% for 100% step load - Short term overload capacity : 120% for 30 minutes, 150% 10 secs and 200% 10 cycles - Protections : Input over/under voltage, phase fail, overload at the output, SOAR protection for IGBTs, Output AC over/under voltage, High speed fuses for semi-conductor devices, Snubber circuits for power semi-conductor devices - Front panel LED indication : Mains on, Inverter on, Battery on charger, Load on Inverter, Load on bypass, Manual bypass on, Mains abnormal, Low battery imminent, DC O/U voltage, Inv O/U voltage, Inverter overload, overheat - LCD metering display for input & output voltage & DC voltage, output frequency, % load, % battery etc - UPS panel of CRCA sheet steel structured Black paint shade (RL7807) with IP-31 protection class complete all as directed. Make : Aplab ltd / Microtek /Exide
S & F 15 KVA true On-line Double Conversion Type UPS system consisting of following:- - Input : 300-450 VAC, 3P4W, 50 Hz + 3Hz Rectifier cum Battery Charger - Output : 230VAC, + 1%, 1P2W, 50 Hz + 1% IGBT inverter - Inbuilt Galvanic Isolation Transformer at Inverter output side - Waveform : Sinewave - Output voltage Harmonic distortion : < 2% for Linear Load and < 5% for Non Linear Load - Transient Response : Less than + 5% for 100% step load - Short term overload capacity : 120% for 30 minutes, 150% 10 secs and 200% 10 cycles - Protections : Input over/under voltage, phase fail, overload at the output, SOAR protection for IGBTs, Output AC over/under voltage, High speed fuses for semi-conductor devices, Snubber circuits for power semi-conductor devices - Front panel LED indication : Mains on, Inverter on, Battery on charger, Load on Inverter, Load on bypass, Manual bypass on, Mains abnormal, Low battery imminent, DC O/U voltage, Inv O/U voltage, Inverter overload, overheat - LCD metering display for input & output voltage & DC voltage, output frequency, % load, % battery etc - UPS panel of CRCA sheet steel structured Black paint shade (RL7807) with IP-31 protection class - Sealed Maintenance Free Batteries of 12V/42AH-30 Nos of Exide with suitable MS open Rack, interconnection links, Battery Isolator & UPS to Battery bank cable of 5 mtrs length to support 30 mins. Backup at full load (Min 15120 VAH) complete all as directed. Make : Aplab ltd / Microtek /Exide
S & F Sealed Maintenance Free Batteries of 12V/42AH-30 Nos with suitable MS open Rack, interconnection links, Battery Isolator & UPS to Battery bank cable of 5 mtrs length to support 30 mins. Backup at full load (Min 15120 VAH) Make: Exide / Star Gold / Amaron
S&F cable 4 Core PVC insulated unsheathed multistranded copper conductor of dia 4 Sqmm complete all as directed. Make: Havells/Finolex/Poly cab
S&F cable 2 Core PVC insulated unsheathed multistranded copper conductor of dia 16 Sqmm complete all as directed. Make: Havells/Finolex/Poly cab
S&F cable 4 Core PVC insulated unsheathed multistranded copper conductor of dia 6 Sqmm complete all as directed. Make: Havells/Finolex/Poly cab
S&F cable 2 Core PVC insulated unsheathed multistranded copper conductor of dia 25 Sqmm complete all as directed. Make: Havells/Finolex/Poly cab
S&F cable 10 Core insulated unsheathed multistranded copper conductor of dia 4 Sqmm complete all as directed. Make: Havells/Finolex/Poly cab
S&F epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand / Havells / L&T / ABB
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 8 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No. 6077 11 / Havells / L&T / ABB
S&F epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB TPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand / Havells / L&T / ABB
S&F MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95 / Havells / L&T / ABB
S&F MCB SPN 10 to 32 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 12 to 4086 17 / Havells / L&T / ABB
S&F MCB TPN 6 to 32 Amp, 50 Hz, AC supply, 10 kA with proper size lugs. Make: Legrand Cat No. 4086 72 to 4086 80 / Havells / L&T / ABB
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point complete all as specified including testing on completion.
M&L earthing with galvanised steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI steel earth strip protected by GI medium grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with XPM (wt not less than 4 kg/sqm) and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exc 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion all as specified.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through heavy duty PVC casing, capping, double lock type, min 25 mm wide including sheet metal box, terminal plates suitable for modular switch, socket etc. with all accessories, concealed GI box / PVC modular box with cover and 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 42 here-in-above but with 2.5 Sqmm cables for one 16Amps , 6-Pin socket outlet point on independent board .
S&F switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S & F Ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 10 Sqmm 2 core making necessary connection & testing on completion all as directed.
S&F 50 W IP 65 LED flood light with high pressure die cast housing with lens having 3000 CCT(k) complete. Make: Jaquar Cat No. LFLD02S050XC or equivalent in Bajaj / Osram / Wipro / Schreder.
S&F mild steel bands, straps, supports or stays for rainwater, hold fasts; wall ties; and similar small articles steel conforming to Fe-290 Gde-E-165.
S&F 3 core, 2.5 sqmm PVC insulated unsheathed multistranded copper conductor cable drawn through suitable size PVC heavy duty conduit pipe from junction box to fitting complete all as specified. Make: Havells / Finolex / Polycab
S&F junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB DP 32 Amp - 01 No., MCB SP 25 A - 01 No. 10 kA fixed to pole/wall with MS clamp 25x5 mm and necessary painting to MS clamp complete all as specified.
S&F junction box made from SMC/FRP sheet readymade of size 195x135x90 mm having with aluminum busbar with 4 way connector concealed in column / wall and making good surface to matchthe existing finish etc. complete all as specified.
S&F 300 mm sweep exhaust fan, 230/240 V, 50 Hz, with lower shutter venti Air and including connecting with three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as directed. Make: Havells Venti Air - DB or equivalent in Khaitan / Bajaj / Crompton
S&F 40W IP 65 decorative LED outdoor post top lighting fixture with powder coated pressure die cast aluminum housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimun Lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket complete all as specified. Make : Bajaj BGCT W4 40W WW LED or Schreder 40W or Panasonic APT010404.
M/S Badri Electicals
jagdish machinery stores
Jyoti Refrigeration
suvidhiconstruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .