Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹30.0 L+₹8,615 (0.29%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹33.2 L+₹3.3 L (11.0%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹36.8 L+₹6.9 L (23.2%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L4 | Rejected-AOC L4 QUOTED | |
| 5 | L5₹37.3 L+₹7.4 L (24.9%)Rejected-AOC | L5 | Rejected-AOC L5 QUOTED |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
18 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56APO
PROVN OF INDEPENDENT ELECTRIC SUPPLY TO PORTA CABINS GUARD POSTS AND THREE PHASE ELECTRIC SUPPLY TO AIRMEN SINGLE ACCOMODATION AT AF STATION CHANDIGARH
2023_MES_614845_1
GE(AF)/CHD/T-34/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
10 documents required · 10 mandatory
₹500
GE AF Chandigarh
₹87,000
Yes
28 Feb 2024
21 Aug 2023
25 Sept 2023
21 Aug 2023
18 Sept 2023
4 Sept 2023
21 Aug 2023 - 28 Aug 2023
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed.
Returning and filling in excavated soil including spreading levelling, watering and well ramming in layers each not exceeding 25mm thick in soft/ loose soil all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid.
Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed.
Supply and fixing GI tubing 80mm bore light grade fixed along walls/ poles/ under road/ culvert etc. complete all as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm 3½ core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3½ core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3½ core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3½ core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3½ core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trenches/ passing through GI tubing etc. complete as specified and directed.
M&L for submain wiring complete with four runs of 10.0 sqmm (nominal area) single core PVC insulated unsheathed FRLS cable 1100 volts grade with copper conductor, drawn in and including 25mm dia PVC concealed conduit with one run of 6.0 sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note: Four runs of 10.0 sqmm multi-stranded cable and one run of 6.0 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for cutting chases for concealed water tubing or concealed conduit wiring etc. water tubing and making good, cutting not exceeding 10cm girth and making good in cement mortar (1:3) including removal of rubbish outside MoD land complete all as specified and directed.
S&F in sheet metal enclosure flush mounted in wall suitable for MCCB as incomer and outgoing MCB's, factory made double door, VTPN 415 volts, 4 ways with 200 Amp bus bar with IP43 protection including making good to disturbed surface complete in all respects complete all as specified and as directed. Note: MCCB/ MCB's shall be measured and paid separately under respective items.
S&F MCCB, 4 pole, 63 Amps, 16 KA, 50Hz, 415 volts with Ics= 100% of Icu with adjustable thermal & adjustable magnetic type relays complete all specified and directed.
S&F MCB SP 240 volts 6 to 32 Amps 'B' curve series all as specified and directed.
S&F MCB FP 415 volts 32 Amps 'B' curve series all as specified and directed.
Disconnecting and taking out existing SPN DB's of any type and size alongwith MCB's/ cutouts all as specified and directed.
Disconnecting and taking out existing LT feeder pillars/ bus bar chambers of any type and size alongwith fittings/ fixtures complete all as specified and directed.
Disconnecting and taking out existing LT cable/ service wire of any type and size all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised Iron strip of size 32mm x 6mm by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C-1 chamber, pit cover of precast RCC (1:2:4) type B-1 reinforced XPM of weight not less than 4 Kg/ Sqm complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion. Notes:- (i) The unit rate shall be deemed to include cost of galvanised iron strip and protection pipe upto 7.5 metre from earth plate to earth point/ test point. (ii) The complete earth system shall be guaranteed to give result less than 5 ohm resistance. (iii) Complete earthing will be redone at no extra cost to department, if result is found above 5 ohm.
Supply, installation, testing and commissioning in replacement LT cubical panel (CPRI Approved) of suitable size to accommodate the following fittings and fixtures and provided with set of 600 Amp, 4 strip aluminium bus bars duly sleeved with relevant colored insulation heavy duly mounted on insulators; factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA sheet on 50mm x 50mm x 6mm angle iron frame, 75cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:-
Supply, installation, testing and commissioning in replacement LT cubical panel (CPRI Approved) of suitable size to accommodate the following fittings and fixtures and provided with set of 500 Amp, 4 strip aluminium bus bars duly sleeved with relevant colored insulation heavy duly mounted on insulators; factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA sheet on 50mm x 50mm x 6mm angle iron frame, 75cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:-
Supply, installation, testing and commissioning in replacement LT cubical panel (CPRI Approved) of suitable size to accommodate the following fittings and fixtures and provided with set of 500 Amp, 4 strip aluminium bus bars duly sleeved with relevant colored insulation heavy duly mounted on insulators; factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA sheet on 50mm x 50mm x 6mm angle iron frame, 75cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:-
Supply, installation, testing and commissioning in replacement LT cubical panel (CPRI Approved) of suitable size to accommodate the following fittings and fixtures and provided with set of 200 Amp, 4 strip aluminium bus bars duly sleeved with relevant colored insulation heavy duly mounted on insulators; factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA sheet on 50mm x 50mm x 6mm angle iron frame, 75cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:-
Supply, install, test & commissioning factory made LT feeder pillar box of size 75cm x 75cm x 60cm with set of 4 strip copper bus bar 200 Amp, 1100 volt grade, 60cm long duly sleeved with relevant colored sleeved cubical outdoor type, weather proof, fabricated out 14 SWG MS sheet, welded on 40mm x 40mm x 6mm angle iron frame & having four Nos 120cm long legs made out of 40mm x 40mm x 6mm angle iron below frame grouted on ground in concrete block of size 80cm x 80cm x 20cm built in PCC (1:2:4) of suitable size with front & rear openable door having locking arrangements, bottom space for cable entry with duly internally and externally painted with two coats of dark grey synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB/ Panel board all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 meter long for earth strip including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC (1:2:4), type B -1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia light grade, common salt, charcoal filling in layers as specified, necessary excavation and earth work in any type of soil etc. including dismantling existing earthing complete all as specified and directed.
R D Bansal
M/s badrinath Traders
PARTAP ENGINEERING WORKS
M/s Shiksha Enterprises
HARISH SALES CORPORATION
Gupta Enterprises
UNITED ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .