| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC DARBHANGA | ₹1.2 Cr | L1 | Accepted-AOC L1 Basis |
| 2 | L2₹1.2 CrRejected-Finance BHILAI | ₹1.2 Cr | L2 | Rejected-Finance Not accepted |
| 3 | L3₹1.2 CrRejected-Finance | ₹1.2 Cr | L3 | Rejected-Finance Not accepted |
| 4 | L4₹1.3 CrRejected-Finance | ₹1.3 Cr | L4 | Rejected-Finance Not accepted |
| 5 | L5₹1.3 CrRejected-Finance | ₹1.3 Cr | L5 | Rejected-Finance Not accepted |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
20 Jan 2026, 3:00 pmClosed
Deputy General Manager (C)
Indian Oil Corporation Limited, Eastern Region Pipelines, Patna Unit Headquarters, IndianOil Bhavan, Bihar State Office, Plot no.-A-6, Patliputra Industrial Area, Patna (Bihar) - 800013
Annual Rate Contract for Civil, Electrical, Housekeeping, Horticulture and other misc works in Mughalsarai and Baitalpur stations in Uttar Pradesh State under ERPL Patna Unit jurisdiction
2026_BKBRN_188267_1
9232C26A02
Open Tender
Civil Works
730 days
MUGHALSARAI AND BAITALPUR
Please refer tender document
6 documents required · 6 mandatory
₹36,000
4 Jun 2026
6 Jan 2026
21 Jan 2026
6 Jan 2026
20 Jan 2026
15 Jan 2026
FIXED PART-NOT TO BE QUOTED
BKPL Mughalsarai
Wages of 1 nos semi-skilled manpower to be paid on monthly basis for attending day to day maintenance requirement at any Station. It includes Minimum basic wages (including PF, ESI and Bonus)(C-Class City) FIXED
For working beyond normal working hours by 1 no. semi-skilled manpower. (C-Class City) FIXED
For working beyond normal working hours by 1 no. unskilled manpower. (C-Class City) FIXED
Reimbursement of payment to the Contractor against additional payment to the workers over & above Minimum wages, if any.(To be paid on actual basis on the instruction of Engineer-in-Charge)
Providing one set of liveries per year to each contract worker. For details refer to tender document. The contractor has to submit o riginal bill, upon verification of which by EIC, payment will be reimbursed. FIXED
Wages of 1 nos unskilled manpower to be paid on monthly basis for attending day to day maintenance requirement at any Station. It in cludes Minimum basic wages (including PF, ESI and Bonus)(C-Class City) FIXED
PMBPL Baitalpur
Wages of 1 nos semi-skilled manpower to be paid on monthly basis for attending day to day maintenance requirement at any Station. It includes Minimum basic wages (including PF, ESI and Bonus)(C-Class City) FIXED
For working beyond normal working hours by 1 no. semi-skilled manpower. (C-Class City) FIXED
For working beyond normal working hours by 1 no. unskilled manpower. (C-Class City) FIXED
Reimbursement of payment to the Contractor against additional payment to the workers over & above Minimum wages, if any.(To be paid on actual basis on the instruction of Engineer-in-Charge)
Providing one set of liveries per year to each contract worker. For details refer to tender document. The contractor has to submit o riginal bill, upon verification of which by EIC, payment will be reimbursed. FIXED
Wages of 1 nos unskilled manpower to be paid on monthly basis for attending day to day maintenance requirement at any Station. It in cludes Minimum basic wages (including PF, ESI and Bonus)(C-Class City) FIXED
VARIABLE PART- TO BE QUOTED
BKPL Mughalsarai
CIVIL Maintenance Works
Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.
Earth work by mechanical / manual means in rough excavaton in all kinds of soil, banking excavated earth, breaking clods, watering,c ompacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in laye rs not exceeding 20 cm thickness and dressing up in embankments for roads, food banks, marginal banks and guide banks or flling up g round depressions, up to all leads and lift.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of su rplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : Pipes, cables etc, not exceeding 80 mm dia.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of su rplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Clearing the area of grass, rank, vegetation, wild growth bushes, trees and plants up to 30 cm. girth measured at a height 1.0 m abo ve ground level from roadside berms, under side of pipelines, under the structures, tank farms, drains, railway exchange yard etc. i ncluding removal of grass, plants and rubbish etc. by cutting with Darant/sickle(hansua) etc. completely near to ground level (The s hoots remaining should not be more than 5cm in height) as per directions of engineer-in-charge and collecting all cut grass, vegetat ion etc. and bundling in to heaps and disposing at earmarked places only within a lead of 3 km with contractor's own transport with all tools, tackles, labour etc. complete as per specifications and directions of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer: 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources]
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer: 1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer:
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from n atural sources]
Providing and laying structural reinforced cement concrete work (1:1.5:3) conforming to IS:456 (1 cement : 1.5 coarse sand : 3 grade d stone aggregate 20 mm nominal size) at all heights and depth for construction of foundations, beams, columns, staircases, chajja,l intels, balconies, shelves, plain window sills, roof slabs, facia, canopies, fins, porch, water tank etc. including providing center ing, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclu sive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. (Payment for Reinforcement shall be made as per relevant item of SOR).
a) All work up to plinth level
b) In superstructure at all floors up to floor five level
Steel reinforcement for R.C.C. workincluding initial straightening of coiled/uncoiled bars, removal of loose rust, cutting, bending to correct size & shape, binding with 18 gauge G.I. wire at each intersection and placing at any position, at any height and depth c omplete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directio n of Site Engineer. : Thermo-Mechanically Treated bars of grade Fe-500 D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1: 4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1: 6 (1 cement : 6 coarse sand
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length [Note: Hold fast lugs or Dash fasteners shall be paid separately und er relevant item of SOR] : Second class teak wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length [Note: Hold fast lugs or Dash fasteners shall be paid separately und er relevant item of SOR] : Sal wood
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For F ixed portion -Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of Gra de AC-15
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For f ixed portion Powder coated aluminium (Minimum thickness of powder coating 50 micron
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For f ixed portion Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and simi lar works, including applying priming coat of approved steel primer : MS Tube
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and simi lar works, including applying priming coat of approved steel primer : GI Pipe
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, b uffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts comple te, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of require d size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-Charge. [Note : For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, f asteners etc.]
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirt ing, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement sl urry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Ceme nt : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption' s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 c ement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :C oupler 110 mm
CEMENT PLASTER (IN COARSE SAND) Rates for external 12 mm cement plaster. 1:6 (1 cement: 6 coarse sand)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Pain ting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of p rimer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Pain ting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape , raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping grou nd within 50metres lead With cement mortar 1:4 (1cement: 4 coarse sand).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obta ined. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]: Nominal con crete 1:3:6 or richer mix (including equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work as per direction of the Engineer-in-Charge . [Notes: (1) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-i n-Charge. (2) Payment shall be made on the cross sectional area of R.C.C. or R.B. work
Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including l oading, transporting, unloading to designated location/ approved municiple dumping ground for lead up to 10 Km and for all lifts, co mplete as per directions of the Engineer-in-Charge. [Note: This item shall also be applicable in urban areas having directions for r estricted hours for movement/ plying of load carrying motor vehicles of 3.5 cum or more.]
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dump ing ground within 50 metres lead.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixture s complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic s eat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, includi ng painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x4 50 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 15 mm nominal dia pipes
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 20 mm nominal dia pipes
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 25 mm nominal dia pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 15 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 25 mm dia. nominal bore
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as p er standard design
Supply of 10 HP Diesel driven dewatering pump with all accessories including hoses along with one operator for dewatering .The job i nvolves pumping out of water including dewatering oily trenches, pits,excavated areas etc. by contractor's own pump as per the direc tion of the Engineer-in-charge.The job also includes supplying of pump, tools & tackles,hoses, fuel,all consumables and labour to co mplete the job in all respects as per EIC(for maximum of 8 Hrs per shift).
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleanin g machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operato r, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing o f sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia up to 300 mm dia for all depth
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the ground
Pruning, trimming, shaping of trees/ shrubs (height 15 feet & above) and removal of cut materials up to 50m lead inclusive of all la bour, T&P, materials etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TREE"].
Removal of garden waste by TATA 407 or equivalent capacity vehicle including loading/ unloading, carriage up to 1.0 Km lead & dispos al at designated place etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TRIP"].
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 80mm thick Cement Concrete paver block of M-30 grade with approved colour, design & pattern
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 100mm thick Cement Concrete paver block of M-50 grade with approved colour, design & patter n.
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 15 mm nominal dia pipes
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 20 mm nominal dia pipes
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 25 mm nominal dia pipes
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron "P" or "S" trap, 10 litre low lev el white P.V.C. dual flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS:7231, w ith all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White vitreous ch ina orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I cl amps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One uri nal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing White Vitreous China Wash basin size 550x400 mm with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing White Vitreous China Flat back wash basin size 550x400 mm with C.I. brackets, single 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing White Vitreous China pedestal for wash basin completely recessed at the back for the reception of pipes and fit tings
Providing and fixing White glazed fire clay kitchen sink of size 600x450x 250 mm with C.I. brackets, C.P. brass chain with rubber pl ug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever requir ed :
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of app roved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of app roved make and shade with 6 mm thick hard board backing: Rectangular shape 1500x450 mm
Providing and fixing PTMT Bottle Trap for Wash basin and sink : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and c olour, weighing not less than 105 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good th e same with cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary pla ster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 50 mm diameter
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 50 mm nominal dia pipes
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of the Engineer-in -Charge : Door chowkhats
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of the Engineer-in -Charge : Clerestory window chowkhats
Supply of tractor with trailer on hire charges for 08 hours per day including rendering the services of 4 labourers driver, fuel and other consumables, tools, tackles etc. for transportation of rubbish/ waste materials complete as per directions of Engineer-in-Cha rge.(8 hours working period of one tractor is considered as one tractor day). Unit "EACH" (EA) stands for tractor days.
Brass floor door stopper: Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS:3564 em bossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with neces sary accessories and screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embo ssed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing Housekeeping, Horticulture and Environment Management
Liquid hand wash dettol (200 ml handwash pump)
Toilet Air freshner Odonil (50 gram for thirty days )
Harpic tolet cleaner (500 Ml)
Lizol Disinfectant Surface Cleaner Citrus (1 L)
Napthalene Balls
Cleaning acid(Muritac acid)for bathroom tiles
Cleaning duster
CoConut Bamboo broom
Green brass broom (Full jhadu)
Flat mop wet and dry cleaning (24 inch)
Mopping cloth
Spin Mop Bucket (Milton brand or Equivalent)
Floor wiper (Brand -Scotch brite or equivalent size 40 cm )
Urinal screen mat with fragrances
Room freshner (200 ml ,Brand-godrej aer or equivalent)
Collins mirror cleaning(500 ml)
Hand towel for toilet (Brand-Raymond or equivalent , Size-40*60 cm)
Fiber bathroom scrubber brush (Brand Scrotch brite or equivalent )
Toilet cleaning brush
Mosquito repellent and machine (good night)
Office room stainless steel Dust bin (Brand -Prestige or equivalent size-12 liter)
Outdoor stainless steel dustbins (Brand -Milton/Prestige or equivalent size-40 liter)
Horticulture
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 Nos horizontal & 4 Nos vertical “U“ shape) M.S. wires of 3.5 m m dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of the Engineer-in-Charge. Top inside diameter 30 cm, outer botto m diameter 20 cm, total height 30 cm with wall thickness of 25.4 mm
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Tree Plant
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Shrub Plant
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Hedge Plant/ Ground Cover
Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas,Mango, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants/fruit-bearing Tree, watering & maintenance fo r 30 days minimum complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
Providing and watering of Horticulture features i.e. lawn, tree, shrubs, hedge/ edge, ground cover etc. with irrigation water at the site of work. Watering shall be done through water tanker having 5000 litre capacity with one labour for watering including cost of water, filling of tanker, watering at site with all leads and lifts as per direction of the Engineer-in-Charge. [Note: Unit "EA" sh all mean "PER TRIP"].
Cleaning and Sweeping of Lawn/ Garden area and keep it neat & clean by mechanized method/ manually, removimg litter, debris, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per direction of the Engineer-in-Charge. [Note: All T&P, materials/ articles shall be provided by the Contractor].
Cleaning the tiles, lavatory, flooring, urinals etc. by removing stains etc. by using Vim powder / cleaning powder / ISI grade black phenyle / while phenyle / Acid /Naptha balls / Coir brushes / wire brushes / Finit in required proportion to make the area clean an d free from all dust, dirt and stains etc. including cost of all labour and materials complete. (Only floor area shall be measured).
Mopping of floors of offices, toilets, control rooms, electrical sub station etc. with soap solution or phenyle water with wet cloth after sweeping the floor with phooll broom, removing cob-webs with all tools, tackles, labour & materials etc. complete as per dire ctions of Engineer -in-charge including cleaning of ventilator glass panes from both the sides upto any height with cleaning powder, paint remover as per requirement all labour, material etc.complete.
Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning po wder, paint remover as per requirement all labour, materials etc. complete. Glass pane not exceeding 1.00 sq.m in area
Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning po wder, paint remover as per requirement all labour, materials etc. complete. Glass pane exceeding 1.00 sq.m in area
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per th e directions of Engineer-in-Charge.
Providing comprehensive pest control services to the building, sheds, cable trenches, drains and other facilities of the establishme nt, to control the nuisance of various pests including (but not limited to) rodents, snakes, lizards, beehives, cockroaches, mosquit oes, Red and Black ants, crawling pests, house flies, fruit flies, etc. Job includes placing / injecting rodenticide baits, glue tra ys, snake repellent and other chemicals, insecticides, Fogging/fumigation, Removal of bee hives below ground (in trenches upto depth of 1m) and above ground (up to height of 15m), complete with all labours, materials, tools, and tackles, equipments, consumables et c complete. Periodicity of scheduled pest control activities shall be monthly, while ad hoc requirement shall be as and when require d as directed by EIC whose decision shall be final. Area of measurement for pest control application shall be designated by EIC. Rat e is For (PER SQM PER MONTH)
Providing toiletries (including mosquito repellent in each room) for cleaning and hygiene service as per SCC. Payment for this item will be paid on actual basis on production of relevant bill.
Up keep of equipment`s & appliances
Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commerc ial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddl e supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc. , sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour , materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.
PU /liquid epoxy Coating of under ground piping Cleaning exposed steel surfaces of piping, equipment and valves etc. by abrasive bla sting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying si ngle layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.
Providing Hydra ( 10-12 TON capacity ) along with belts, chains, hooks etc at site for shifting heavy material or equipments like pi pes, welding machine, cold cutting machine etc.The rate is inclusive of mobilisation and demobilisation cost, hiring and running cos t, fuels, consumables, lube oil cost, operator cost etc., as per direction of EIC. Payment towards equipment running charges shall b e made only if payments are not covered in any of the SOR items elese where in this contract.
Providing welder, cutter, grinder team
Providing & operating JCB for earth work in excavation in both ordinary & Rocky soil for ROW cleaning, washout rectification/ instal lation ofanode ground bed, sacrificial anodes, cable trenches, pipelinetrenches, etc. including backfilling the same after completio n of workin all respect and up to the satisfaction of Site Engineer / EIC & thecost includes all labour, materials complete as per d irection of SiteEngineer/ EIC.
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment Removing loose scales,blisters etc from ol d painted surface by scrapping with wire brush thoroughly and smoothening the surface to make it suit- able for receiving fresh coat of paint
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment. Application of one coat ready mixed oil b ased red oxide zinc chromate primer
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment. Application of Two or more coats of any s hade of Aluminium Paint
Electrical ARC
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of sit e engineer / Engineer-in-Charge:
Supply and fixing of following size of PVC conduit alongwith the accessories in surface including conduit as required: Note: Only IS I marked conduits shall be used.
PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.:
Providing and fixing following size of PVC casing and caping on surface as required. Note: Only ISI marked caping and casing shall b e used.
15 mm x 10 mm
20 mm x 10 mm
25 mm x 10 mm
30 mm x 10 mm
40 mm x 20 mm
50 mm x 20 mm
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge:
Power cables LT : OD upto 20 mm
Power cables LT : OD above 20 mm and upto 40 mm
Power cables LT : OD above 40 mm and upto 60 mm
Power cables LT : OD above 60 mm
Power Control cables LT : OD upto 20 mm
Control cables (T&I) : OD upto 20 mm
Control cables (T&I) : OD above 20 mm and upto 30 mm
Control cables (T&I) : OD above 30 mm and upto 40 mm
Supplying and drawing following size of FRLS PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC / steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used.
1 x 1.5 sq.mm
2 x 1.5 sq.mm
3 x 1.5 sq.mm
4 x 1.5 sq.mm
5 x 1.5 sq.mm
6 x 1.5 sq.mm
7 x 1.5 sq.mm
8 x 1.5 sq.mm
9 x 1.5 sq.mm
10 x 1.5 sq.mm
2 x 2.5 sq.mm
3 x 2.5 sq.mm
4 x 2.5 sq.mm
5 x 2.5 sq.mm
6 x 2.5 sq.mm
7 x 2.5 sq.mm
8 x 2.5 sq.mm
9 x 2.5 sq.mm
10 x 2.5 sq.mm
2 x 4 sq.mm
3 x 4 sq.mm
4 x 4 sq.mm
5 x 4 sq.mm
6 x 4 sq.mm
7 x 4 sq.mm
8 x 4 sq.mm
9 x 4 sq.mm
10 x 4 sq.mm
2 x 6 sq.mm
4 x 6 sq.mm
5 x 6 sq.mm
6 x 6 sq.mm
7 x 6 sq.mm
8 x 6 sq.mm
9 x 6 sq.mm
10 x 6 sq.mm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed steel conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in surface steel conduit a s required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed, PVC medium du ty conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in surface PVC medium duty conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Supply, fixing and connection of 250 V below given mosaic modular wiring accessories of M/s MDS or approved equivalent inlcuding sup plying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
6 amps. - 1 way - SP - 1 module switches
10 amps. - 1 way - SP - 2 module switches
16 amps. - 1 way - SP - 1 module switches
6 amps. - 1 way - SP - 1 module push button
Two module stepped type electronic fan regulator 100W
6 amps. - 2 / 3 pins combined 2 module shutterred socket
6 amps. - 3 pins combined 2 module shutterred socket
6 / 16 amps. - 3 pins combined 3 module shutterred socket
16 amps. - 3 pins - 3 module switch socket
1 module blanking plate
6 pin 25 A modular type socket lSI Marked
Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 module
2 module
3 module
4 module
6 module
8 module
12 module (6 x 2)
18 module (6 x 3)
Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 / 2 module
3 module
4 module
6 module
12 module (6 x 2)
8 module
Supply and fixing of below given metal surface boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlc uding supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 / 2 module
3 module
4 module
6 module
12 module (6 x 2)
8 module
Fixing of wall monted fan completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of Fans shall be excluded)
Fixing of exhaust fans on existing opening, complete with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in- Charge. (cost of fans shall be excluded)
WITHOUT LOUVER SHUTTER/MESH
FLP/IS EXHAUST FAN
Numbering of ceiling fan, exhaust fan and flourescent fittings as required.
Extra for fixing the louvers / shutters complete with frame for exhaust fan of all sizes
Repainting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved bra nd and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
Installation, testing and commissioning of ceiling fan and regulator including wiring the down rod of standard length (upto 30 cm) w ith 1.5 sqmm, PVC insulated, copper conductor, single core cable etc. as required.
Fixing of following light fittings attachments on MS hanger/supports/concrete wall structure /steel structure completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of light fitti ngs/lamp control gears and other fittings shall be excluded). [work to be carried out only in deenergized state]
(FLP/INCREASED SAFETY) (WELLGLASS/ BULKHEAD/ TUBELIGHT)
RECESSED TUBELIGHT FITTING
ORDINARY BULKHEAD/PL TYPE FITTING
STREET LIGHT FITTING (UPTO 9 M HEIGHT)
STREET LIGHT FITTING (MORE THAN 9 M HEIGHT)
FLOODLIGHT WITHOUT CONTROL GEAR (UPTO 9 M HEIGHT)
CONTROL BOX (UPTO 9 M HEIGHT)
FLOODLIGHT WITHOUT CONTROL GEAR (MORE THAN 9 M HEIGHT INCLUDING ON FLDM)
CONTROL BOX (MORE THAN 9 M HEIGHT INCLUDING ON FLDM)
Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SYSKA/Oreva/Crompton or equivalant Indian make). Item includ es Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc.. [w ork to be carried out only in deenergized state]
9W, LED Tube Light Fitting, 2FT, 230V AC
15W, Outdoor LED Light Fitting, IP55, 230V AC
40W LED Light/Lamp, 230V AC, 50Hz
120W LED Flood Light Fitting, with IP65, 230V AC, 50Hz
40W Flameproof LED Well Glass Light Fitting, 230V AC, 50Hz
LED Light Driver of Flood Lights (complete set replacement for 350W and above Flood Light with specifications in conformance to orig inal light drivers)
18W, LED Tubelight Fighting, 230V AC, 50Hz
09W, LED Bulb/Lamp, 230V AC, 50Hz
15W, LED Bulb/Lamp, 230V AC, 50Hz (indoor)
200W LED weatherproof Flood Light Fitting,, 230V AC, 50Hz
Supply & support in installation of elmex terminals supply and support in fixing and connecting elmex type terminals wherever requir ed. job includes drilling holes, providing and fixing clamps, nuts and bolts etc. suitable for terminating 2.5 mm2 copper conductor. job should be carried out as per drawing.( per terminal )
Supply and support in fixing and connecting channels for elmex type terminals wherever required. job includes drilling holes. provid ing and fixing clamps, nuts and bolts etc.
LIGHTING CONTROL
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-non regulated programmable
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-regulating programmable with day light di mming
Supply, installation,testing and commissioning of occupancy sensor based on microwave technology-non regulated programmable
Supply, installation,testing and commissioning of astronomical time switch (Electronic Timer) for single phase supply with 1 output per phase
Supply, installation,testing and commissioning of astronomical time switch for single phase supply with 2 outputs per phase
Supply, installation,testing and commissioning of astronomical time switch for three phase supply with 1 output per phase (total 3 o utputs)
Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and i nstallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other requir ed materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from t he approved make list given in the specifications:
Tube light fitting type Quadra 2 BBS805 2 X LLM 1800/840 PSU-E 220V-240V LED luminaire of PHILLIPS or approved make, complete with a ll accessories suitable for mounting in false ceiling as per the directions by EIC / Site Engineer.
LED Ceiling Point: Supply and fixing of surface mounted LED ceiling light fitting type Mainstream spot Aura 15W of PHILLIPS or equiv alent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including i nstallation.
WP Endura LED: Supply and fixing of surface mounted weather proof Endura LED WT 550 light fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation.
LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equivalent approved make with LEDs: Suppl y and fixing of recess mounted weather proof light Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equiavlent approved make with LE Ds, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIPS or equivalent approved make complete with all accessori es such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.
LED light fittings with LEDs, Sereno LED-Suspended-SP824 P LED 30S-5000 GR OD or approved equivalent:Supply and fixing of surface mo unted weather proof light SP824 P LED 42 W having 2950 lumens output fitting of PHILLIPS or equivalent approved make complete with a ll accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved ma ke.
LED light fittings, Batten with 2XTLED-TMC501-2X TLED-36 W P3242 or equiavlent approved make with LEDs: Supply and fixing of wall mo unted/ suspended type weather proof light 2XTLED-TMC501-2X TLED or equiavlent approved make with LEDs, 36 W or more. LED Fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector block s etc including installation with LED of approved make.
Critical Light: Non Flame Proof type PEL 240 M/SL of Prolite or of approved make as per EIC, with 2 X 18 W LED TL/ Lamp including se aled lead acid battery of suitable size for minimum 01 hour back up, battery charger, for Fire fighting pump shed, HT/LT Room, Batte ry Room etc.The job includes connection of the fitting, 6A switch socket with 2C x 4 sqmm cable from DB/switch board and as mentione d above including all accessories etc. complete in all respect as per direction of EIC / Site engineer.
FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group II A & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified en closure:
FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007
FLAMEPROOF LED WELL GLASS FITTING 90 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Well Glass Light Fixture with provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compressi on type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED FLOOD LIGHT FITTING 90 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED FLOOD LIGHT FITTING 45 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
Critical Light: Flame Proof & Weather Proof supply, erection (fixing the same on roof truss, wall, column etc. as required), termina tion of 240V, flame proof light fittings with heat resistant glass diffuser and suitable for LED lamp, IP65, of model PEL 111 Prolit e make or equivalent approved makes as per EIC. The job includes the cost of fitting and erection 1 no. LED lamp 18W, Ni-Cd battery of suitable size for minimum 01 hour back up, battery charger, earthing, supply & erection of all accessories, suitable MS brackets etc. complete.
Rewinding of ceiling/pedestal/exhaust/air circulator fans of all types/sizes/make including 1-phase and 3-phase type exhaust fans ma x. upto 2.2 KW capacity and supply of super enameled winding wire (Devi Dayal make, ISI marked insulation materials required). This also includes replacement of single/double bearing SKF make/bushes (as per original make) and overhauling of fan and all jobs relate d to complete this work in totality. This also includes removal of fans from site, installation and commissioning after testing of r ewound fans and replacement of condenser, if required. This also includes transportation from site after dismantling to Contractor’s workshop and back to site. Note: Contractor has to give guarantee for rewinding of above items for a period of six months and if wi nding is burnt again within six months of working of fans, it has to be rewound again of Contractor. The burnt winding shall be kept by Contractor.
Ceiling/pedestal fans
Exhaust/air circulators fans.
Overhauling of exhaust/air circulator fans of various types/sizes makes and its bearings including removal from site, cleaning, grea sing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back all complete with labour and materials as per directions of Engineer-in-Charge.
Excluding the cost of bearings (Bearings if necessary will be supplied by Owner ).
Including supply and fixing of bearings of SKF make (02 Nos. bearings)
Overhauling of ceiling/pedestal fans of various types/ sizes/make and its bearings including removal from site, cleaning, greasing a fter degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and ba ck. All complete with labour and materials as per directions of Engineer-in-Charge.
Excluding the cost of bearings. (Bearings if necessary will be supplied by Owner .
Including supply and fixing of bearings of SKF make and bushes (as per original make) of both sides by Contractor.
Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
CU,2CX2.5 mm²,2XWY
CU,3CX2.5 mm²,2XWY
CU,3CX4 mm²,2XWY
CU,6CX2.5 mm²,2XWY
CU,12CX2.5 mm², 2XWY
CU,2CX4 mm²,2XWY
CU,4CX4 mm²,2XWY,
CU,3CX6 mm²,2XWY
CU,2CX10 mm²,2XWY
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overal l sheathed, Stranded, FRLSH, C2, Smoke density<40%
AL,3CX10 mm²,A2XFY
AL,3CX16 mm²
AL,4CX10 mm²,A2XFY
AL,4CX16 mm²,A2XFY
AL,3CX25 mm²,A2XFY
AL,3.5CX25 mm²,A2XFY
AL,4CX25 mm²,A2XFY
AL 3C x 35 mm²
AL,3.5CX35mm²,A2XFY
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make
Copper Cable size 1cx25 sq.mm Armoured
Copper Cable size 2cx6 sq.mm Armoured
Copper Cable size 2cx25 sq.mm Armoured
Copper Cable Kynar/HMWPE size 1cx10 sq.mm Unarmoured for distributed anodes of station CP system
CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grad e control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glan ds, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying.
16C x 2.5 sq. mm. Cu. Control cable
12C x 1.5 sq. mm. Cu. Control cable
6C x 1.5 sq. mm. Cu. Control cable
4C x 2.5 sq. mm. Cu. Control cable
EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earth ing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing elect rodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-char ge, including the cost of all labour, tools, materials, etc. complete in all respect:
50 mm X 6 mm G.I. earthing strip
40 mm X 5 mm G.I. earthing strip
25mm x 4 mm copper flat
25mm x 3 mm copper flat
GI wire (8 SWG)
GI wire / rope 35 sq. mm
GI wire / rope 10 mm diameter
Copper cable as per specifications - 10 Sq.mm
Providing salt and charcoal for plate earth electrode as required.
96 kg charcoal and 5 kg salt
240 kg coke and 5 kg salt
Providing salt and charcoal for pipe earth electrode as required.
64 kg charcoal and 5 kg salt
160 kg coke and 5 kg salt
Providing Earthing with bare stranded tinned copper flexible conductor including providing and connecting equipments with earth busb ar, supply and fixing of copper stranded wire of following sizes and making connection with equipment by means of GI bolts, nuts, wa shers, copper lugs etc. all complete with labour and materials as per direction of Engineer-in-Charge.
Providing earthing with copper plate as per IS: 3043 standard / drawing / specification with plate size 600 mm x 600 mm x 3 mm plate materials tinned copper plated with drilled hole at centre to receive 50 mm long 13 mm bolt, nut and double washer screwing system with copper tape/copper flexible. The tape/flexible shall be inside 1 1/2" dia GI pipe length from copper plate to the system to be earthed. The Plate shall be burried at a minimum depth of 4.5 Mtr below ground level on its edge and 2 Mtrs away from building/equip ment foundation and shallbe connected to the equipment. The size of the copper flexible shall be not less than 19 mm x 1.6 mm. The i tem includes labour and materials all complete (but without coke or charcoal and salt). Charcoal and salt cost will be paid seperate ly as extra.
Providing earthing with GI plate as per IS: 3043 standard / drawing / specification with plate size 600 mm x 600 mm x 6 mm thick pla te with drilled hole at centre to receive 50 mm long 13 mm bolt, nut and double washer screwing system with GI tape / GI flexible. T he tape / flexible shall be inside 1 1/2" dia GI pipe length from GI plate to the system to be earthed. The Plate shall be burried a t a minimum depth of 4.5 Mtr below ground level on its edge and 2 Mtrs away from building/equipment foundation and shall be connecte d to the equipment. The size of the GI flexible shall be not less than 19 mm x 3 mm. The item includes labour and materials all comp lete (but without coke or charcoal and salt). Charcoal and salt cost will be paid seperately as extra.
Providing and fixing of lightning conductor finial, made of 25mm dia. 300mm long, copper tube, having single prong at top, with 85mm dia. 3mm thick copper base plate including holes etc. complete as required.
Providing and fixing of lightning conductor finial, made of 25mm dia. 300mm long, GI tube, having single prong at top, with 85mm dia . 6mm thick GI base plate including holes etc. complete as required.
Fixing of lightning conductor finial made of 24mm dia. 300mm copper tube / GI tube, having single prong at top, complete with base e tc. as required.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. co mplete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. comp lete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the m ain earthing grid.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 4 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. comp lete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the m ain earthing grid.
Spreading the stone chips per CUM
Temporary laying and dismantling of following cables (armoured/ unarmoured, power/control/ telecommunication/ computer) of different voltage grades/sizes/types for temoprary connections during shutdown etc., including transportation of cable from stores/another si te and returning the same after dismantling to store, all complete with labour and materials as per directions of the Engineer-in-Ch arge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Cleaning of below given fitting fixtures alongwith perfex cover (wherever applicable) with the help of surf powder. It includes the removal of perfex cover, washing the lighting fixture with powder, cleaning with fresh water and clothes and refixing in the same po sition. It also includes arranging ladder as and wherever required, providing scaffolding at all heights with necessary tools & tack les. All complete with labour and materials as per directions of the Engineer-in-Charge.
Tube light fitting/ceiling/exhaust fan/fan at any height inside a building.
MLL/HPMV/HPSV lamp of FLP /increased safety/ weather proof or any other similar fittings upto 250 W
Support in Connection and disconnection of Hand lamp/grinder/wooden boards of different sizes with any No. of switch/sockets of diff erent ratings, etc (small equivalent equipments). with flexible wire of sizes 1.5 sq.mm/2.5 sq mm / 4 sqmm including to and fro tran sporting it to Owner’s store or any other place.. All complete with labour and materials as per directions of the Engineer-in-Charge . NOTE Hand lamps / flexible wire are to be supplied by Owner. Consumables like PVC tape, CTC, cleaning cloth are to be supplied by Contractor.
Support in Cleaning of complete PCC/MCC panels. It includes opening of side top covers, removal of dust by vacuum cleaners/blowers e tc., checking and tightening of screws, nuts, bolts, washers & connections, application of petroleum jelly and boxing up of the pane ls. All complete with labour and materials as per directions of the Engineer-in-Charge.
Support in Repair/replacement of kit/kat/HRC fuse bases of different sizes in feeder pillars, main switches, substations, pump house s, residential buildings, public buildings, hospitals, clubs, schools, shopping center and at any other place where special programm es are being organized from time to time for restoring the power supply. Job complete in all respects as per directions of the Engin eer-in-Charge. NOTE: Fuse base of capacity from 16 Amp. To 300 Amp. of any voltage grade will be supplied by Owner .
Support in Measurement of earthing resistance in the station including transportation of earthing electrodes, cables etc. from store s to site, drawing the same into the ground at different points for measuring the earth resistance. The job includes the supply of c onnecting leads, clamps etc. All complete with labour and materials as per drawings, specifications and directions of the Engineer-i n-Charge. NOTE Measuring instruments to be supplied by the Owner.
Attending and rectification of complaint of the following NOTE: All materials & accessories of fittings required for attending the c omplaint shall be supplied by the owner . The Contractor has to take the material from central store/departmental store/site in-Char ge. for attending above complaints. The defective material are to be returned to the Deptt. Stores. Consumables items like PVC tape, cleaning tape, cleaning cloth, CTC etc. are in the scope of contractor. Also application of PVC/M-seal on above fittings to above e ntering of water/insects as per direction of the Engineer-in- Charge.
Tube light fittings including replacement of chokes, tubes, down rods, starters, starter holder, Tube rod and holders and all other accessories if needed including cleaning of the light fittings if required. All complete with labour and materials as per direction of the Engineer-in-Charge.
Control gear boxes of HPMV lamp fittings upto 250W including replacement of chokes, condensers, fuses, holders, fuse base, wiring or any other accessories of control gear box. All complete with labour and materials as per directions of the Engineer-in-Charge.
FLDMs/highway fittings/street light fittings including replacement of lamps, tubes, ignitors, chokes, capacitors, fuses, fuse holder s, gasket, providing/extension rod on lamp holder glass including cleaning of glass or any other accessories required. All complete with labour and materials as per directions of the Engineer-in-Charge.
Attending complaints of ceiling/ exhaust/ wall mounted/ pedestal/ air circulators/any other type of fans of various sizes/makes incl uding replacement of condensor, regulators etc. All complete with labour and materials as per directions of the Engineer-in-Charge. NOTE : Condensor and regulators will be supplied by Owner , consumables like PVC tape, cleaning cloth, CTC etc. are to be supplied b y Contractor.
Attending complaint of installation e.g. hand lamps, flood lights, exhaust fans, halogen fittings, smoking booth & other elect. Comp laints & replacement of crocodile clips on earthing leads with a maximum period of one hour from the time of receipt of complaint.
Support in Rectification of circuit fault in FLP/Non FLP junction boxes/DJBs/DBs/switchboards etc. other than in FLDMs including sup ply of minor type of materials costing less than Rs.6.00 in one complaint. All complete with labour and materials as per directions of the Engineer-in-Charge. NOTE : Materials used by contractor should not exceed Rs.6.00 per complaint. Balance material exceeding R s. 6.00 per complaint shall be supplied by Owner . Also application of PVC putty/M-Seal putty on above fittings, if required, to avo id entering of water/insects as per directions of the Engineer-in-Charge. Putty will be supplied by Owner .
Transportation of transformer oil anywhere within Station premises in drums of 200 Ls or more from Electrical Workshop/Store to site , pouring transformer oil in transformer tank and returning empty/filled drums from site as given below to Electrical Workshop/Store s etc. including supply of tractor & trailor with man power, driver and fuel etc. required for loading, unloading & transportation o f empty/filled transformer oil drums. All complete with labour and materials as per directions of the Engineer-in-Charge.
Support in Providing temporary Electrical connection for Hydroblast machines, welding machines & other electrical equipments of vari ous rating/capacity, including bringing, shifting necessary materials (except power cable beyond 5 mtrs, which will be paid seperate ly) from store to site & cleaning these Electrical equipments before connections. The connection will have to be dismantled by contr actor at the end of shutdown and return the materials back to store or any other place as directed by the Engineer-in-Charge. The co ntractor has to clear the site area after the end of the work. These services may be required to be given by the contractor at site round the clock including laying of cable up to maximum length of 5 mtrs. All complete with labour and materials as per direction of the Engineer-in-Charge. Note: All the above mentioned materials to be supplied by owner , consumables like PVC tape, CTC, cleaning cloth etc. are to be supplied by contractor.
Support in Installation of all types of (including FLP/Non FLP) temporary light/Fan fittings (TL Fixtures/ML Lamp with holder/Haloge n fitting /exhaust /pedestal /ceiling fans of different sizes/types/make, ICTPN of any rating, 1000W flood light fittings, 24V trans formers of capacity more than 500 VA or any other type of light fittings) of any sizes/ model/ make, connections etc. including dism antling of this fitting etc. and to and fro transporting it to Owner’s store or any other place. All complete with labour and materi als as per directions of the Engineer-in-Charge.
Support in Cleaning of cable trenches of depth upto 3 meter and width 1.5 meter of cable galleries, sub stations and other locations etc. The job includes lifting of RCC slabs/ Chequerred plates, removing of paper waste jute, mud, or any other unwanted materials l ying in trenches & dumping these waste materials in the nearest dust bin or as directed by the Engineer-in-Charge., keeping back RCC slabs/chequerred plates in positions. All complete with men and materials as per direction of the Engineer-in Charge.
Application of PVC putty/M-seal putty on lighting fixtures/Jn. Boxes/glands/switch boards etc. to avoid entering water/insects/any o ther type of things as per direction of the Engineer-in-Charge. NOTE: Putty will be supplied by owner .
Support in Cleaning of transformer includes surface cleaning i.e. cleaning of accumulated sticky oil and other dust, oil fins. Job i ncludes Support in opening of LT duct & HT terminal box, cleaning of duct and terminal box, tightening of nuts & bolts wherever is r equired. Job to be completed with all men, materials and equipments like tools & tackles as per direction and satisfaction of the En gineer-in-Charge. All cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the Contractor.
Support in Cleaning of HT/LT motors & its push button includes cleaning of accumulated oil/spilage oil & other particles on the surf ace of motor & connected cable & surrounding area of the motor. All cleaning material such as cotton waste, markin cloth etc. shall be supplied by the contractor. Job to be completed with all man & material as per direction & entire satisfaction of the Engineer-in - Charge.
HT Motors
LT motors less than 45 KW
LT motors 45 KW & above
Support in Disconnection of LT cables of following sizes at one end and reconnecting it at same place or another place after dressin g and cleaning the terminals all complete with labour and materials as per the direction of the the Engineer-in-Charge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Supply, installation and fixing of ms chequered plates of 5mm thickness. job includes cutting to size, supply of hinges / hooks for lifting, tag welding with support wherever required, painting including supply of paint, supply of all material and labor complete i n all respect
Supply and laying of rcc pipe with collers jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sa nd) for road crossing Pipes are to be laid after ramming and consolidating the ground with bricks, stone chips etc. to avoid any set tlement afterwards. Job includes supply of all labor and all materials required and executed as per direction of site engineer.
100 mm dia. R.C.C. pipe
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:
RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.
Supply and installation of 11/6.6 KV Discharge Rod as per relevant IS code
Supply and installation of 33 KV Discharge Rod as per relevant IS code
Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachk ing and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg
Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language as per relevant IS code.
Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language.
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, ba ckfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg /Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply, installation & fixing of prefabricated perforated Aluminium cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 60 0 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Removal of bricks from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or stacking it at t he edge of the trench and putting it back into the same trench or in a new cable trench as per drawing/ specification within a lead of 50 meteres after the work is completed including completing the work in allrespects with all labour and materials as per the dire ction of the Engineer- in-Charge.
Removal and relaying
Removal and stacking only
REMOVAL OF SAND FROM CABLE TRENCH: Removal of sand from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back into the same trench or in a new cable trench as per drawing within a lead of 50 meteres all comple te with labour and materials as per the direction of the Engineer-in-Charge.
Removing of MS chequered plate for cable ducks/ trenches and placing them after the job as per directions of EIC.
Dismantling of battery set including removing electrolyte from cell and transporting to the store (per cell).
415 V AC 3 phase / 230 V AC single phase motors - Support in Connection and testing of 415 V AC 3 phase / 230 V AC single phase moto rs (including space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control a nd power cables, earthing of the motor/actuator/ connecting the thermistor, installing the controller in LT panel, earthing the moto r frame, armour etc. as per the drawings, erection manuals, and as per directions of Site Engineer. Job complete in all respects inc luding the cost of supplying and installation of all the required FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wi re / strips, labour, tools, materials, etc., as required in all respects for all types of motors/heaters/thermistors/actuators etc.:
Capacity upto and including 1 KW
Capacity above 1 KW and upto 2.5 KW
Capacity above 2.5 KW but upto 7.5 KW
Capacity above 7.5 KW but upto 50 KW
Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall final layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to connection plat e. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractor exc luding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip basis.The windi ng wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decision of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nuts, bolts, washers and ot her hardwares as per original specifications. This further includes replacement of bearings (DE & NDE) of SKF make & greasing (IOC/H P make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Fu ll load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contractor free of cost. All complete wi th labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor. Bearing Shall be supplied by IOCL
Motors upto & including 1.5 KW
Motors above 1.5 KW but upto including 3.7KW
Motors above 3.7 KW but upto including 7.5KW
Motors above 7.5 KW but upto including 11 KW
Motors above 11 KW but upto including 18.5 KW
Motors above 18.5 KW but upto including 30 KW
Overhauling and painting of WAC, SAC, WC & Cold Storage of different make & different capacities located at various location within the Station premises, Station township and air monitoring stations, job includes removal of machines from location, dismantling, cle aning, washing, chemical cleaning of condenser & cooling coil, overhauling, lubrication of blower motor, checking, repair/rectificat ion/replacement of effective control component. Painting of all metal part and chassis cover internal painting with primer & outer p ainting with synthetic enamel paint. Cleaning of coil & condenser to be done with wire brush. Defective/damage insulation to be repl aced. All the electrical wires must be dressed properly. Defective wires to be replaced including supply of wires. Defective/damage asbestos sheet to be replaced. Asbestos sheet shall be provided by the owner. Cleaning/replacement of filter by Nylon filter. Re-ass embly of machine, shifting to location & testing of machine. Job complete in all respect including men & material and as per directi on and instruction of Site Engineer/Engineer-in- Charge.
Routine, regular and breakdown maintenance of WAC, SAC, WC and cold storage of different make & different capacities. Installed at v arious location of Station premises, Station township & air monitoring station. Job includes attending the complaints of machines as per the complaint register and instruction of site engineer. Job includes checking of machines, identification of defect, repair/re placement of defective component. Rewinding of blower motor. Replacement of Thermostat, Blower, Fan blade, electrical switches, cont rol knob, wires. Cleachning of air filter, removal of dust from cooling coil & condenser by removing the machine from location if re quired. Attending the minor/major leakage of refrigerant gas R- 22/R-12 arresting the leak and recharging the gas. Repair/replacemen t of defective bush/bearing of blower motor including lubrication of blower motor, tightening of all the electrical connection. Repa ir/Replacement (by repaired compressor) of defective compressor. Job includes dismantling of defective compressor either at site or at workshop after transportation of machine to workshop, taking necessary gate pass/permission from concerned authority, sending the defective compressor to repairer shop and bringing back the same/replaced (repaired) compressor from repair shop to site, re-fixing , gas charging, testing & commissioning and making the machine in perfect working condition. Replacement of all type of defective ca pacitor. Job also includes connection/disconnection for heater as per requirement and also replacing/the new fixing the new heater i n the machine. The heater shall be provided by the department. Job complete in all respect including all consumables including gas, men & material and as per direction and
Supply & fixing of remote control switch pendant type for temperature controlling of the Voltas/Amtrex/ Fedders Lloyds/ Carrier Airc on or any other make, split air conditioners of 2.0/3.0 (2x1.5 TR) TR capacity. Job includes dismantling of the defective switches a nd wire and installation of new switch. Job complete in all respect including man and material and as per the directions of Engineer -in-Charge.
Dismantling & shifting of Split Air Conditioning Unit 1.0TR / 1.5TR / 2.0TR capacity including indoor and outdoor unit, refrigerant tubing etc. complete to new location or A/C workshop as per direction of Engineer-in-charge.
Installation of split type wall Mounted Air Conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and fir st charge refrigerant R410A/R22/Other, including connection of copper pipe and material supplied with complete unit etc. as required (Excluding cost of copper pipe) within Station / Petrochemical Complex/ Station Township as per direction of Engineer-in-charge.
Supply & fixing of additional length of copper tube for split A/C commissioning including all accessories.
Replacement of burnt uncut compressor of 1.5-ton capacity from the manufacturer whenever required as per direction of engineer-in-ch arge.
Gas charging of air conditioner upto 1.5ton capacity with job involved transportation of machine to vendors' works. Checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charges of refrigerant gas - 22. A
Replacement of burnt uncut compressor of 1.0 ton capacity from the manufacturer whenever required as per direction of engineer-in-ch arge.
Supply & Installation of MS Stands for mounting of Outdoor Units.
Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cabl e drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantlin g of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
DISMANTLING OF ELECTRICAL WIRING Electrical wiring (comprising of single or twin core PVC wires upto 6 Sq mm and single earth wire u pto 6 SWG) along with its connected accessories like junction boxes, surface conduits, battons, switch boards etc.: Electrical wirin g (comprising of single or twin core PVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with its connected accessories l ike junction boxes, surface conduits, battons, switch boards etc.
Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays and relaying as per drawing and direction of Engineer-in charge, all complete with labour and materials. Job includes declamping, rerouting and relaying of cab le for reglanding etc.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Disconnection, Sealing with waterproof cable end cover and coiling it neatly for placing in cable trench below, of incoming and outg oing cables from the panels and equipments:
2/3/4/5/6C upto 95 sqmm
2/3/4C from 120 upto 400 sqmm
Dressing of cable in underground trenches, cable trays/rack etc. including supply and fixing of clamps etc., wherever necessary, as per the direction of the Engineer- in-charge
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Providing and fixing of 16 / 0.20 mm twin twisted, flexible, cotton braided, copper cable in polythene sleeve or conduit of suitable size on floor / wall or on side of the table /door etc. as required.
Providing and fixing of 16 / 0.20 twin core, PVC sheathed flat, flexible, copper cable on floor / wall or on side of the table / doo r etc. as required.
Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, with acrylic door cover, IP-42 /43, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for moun ting MCBs (but without MCBs and incomer ) as required as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Char ge.
4 way (4+4+12), TPN, vertical type, MCB DB, double door, IP-42
8 way (4+4+24), TPN, vertical type, MCB DB, double door, IP-42
12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-42
6 way (4+4+4+18), TPN, vertical type, MCB DB, double door, IP-43
Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, with metal double door, IP-54, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Charge.
4 way (4+4+12), TPN, vertical type, MCB DB, double door, IP-54
8 way (4+4+24), TPN, vertical type, MCB DB, double door, IP-54
12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-54
Supply and installation of blanking plates in all types of DBs as per direction of Engineer-in-charge.
Supply, fixing and manpower support in connection of following industrial type plugs / sockets (confirming to IS/IEC-309) of M/S HAV ELL/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.
PLUG- 2 POLE+ EARTH, 250V- 10 AMP
PLUG- 2 POLE+ EARTH, 250V- 20 AMP
PLUG- 3 POLE+ EARTH, 440V- 10 AMP
PLUG- 3 POLE+ EARTH, 440V- 20 AMP
SOCKET- 2 POLE+ EARTH, 250V- 10 AMP
SOCKET- 2 POLE+ EARTH, 250V- 20 AMP
SOCKET- 3 POLE+ EARTH, 440V- 10 AMP
SOCKET- 3 POLE+ EARTH, 440V- 20 AMP
Supplying and manpower support in fixing 20 amps., 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclo sed plug top alongwith 20 amps. C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Note:ISI marked sockets shall be used.
Supplying and manpower support in fixing 20 amps., TPN, industrial type socket outlet, with 4 pole and earth, metal enclosed plug to p alongwith 20 amps. C Curve, TPMCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outle t, and complete with connections, testing and commissioning etc. as required. Note: ISI marked sockets shall be used.
Supplying and manpower support in fixing 30 amps., TPN, industrial type socket outlet, with 4 pole and earth metal enclosed, plug to p, alongwith 30 amps., C curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Note: ISI marked sockets shall be used.
Supply of TPN, switch disconnector fuse unit (panel mounted type) of following rating with ISI marked HRC fuses as per direction of Engineer-in-Charge.
Supplying following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinne d copper bus bar, neutral bus bar, earth, bar, din bar, interconnections, powder painted etc. as required. (But without MCB/RCCB/ELC B/Isolator) as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Charge.
Sheet steel DP MCB enclosure
Sheet steel TP MCB enclosure
Supplying and manpower support in fixing of following rating 240 volts, 50Hz, 10KA, 'B' Curve, miniature circuit breacker (suitable for lighting and other domestic loads and conforming to IS 8828:19) of single poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp/equivalent make shall be used as per direction of Engineer-in-Charge.
5 To 32 Amp
Supplying and manpower support in fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA 'C' curve, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kop p or equivalent make shall be used as per direction of Engineer- in-Charge.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and netural
Four pole
Supplying and manpower support in fixing following rating, single pole & double pole isolator in the existing MCB DB complete with c onnections, testing and commissioning etc. as required. Note: ISI marked isolators shall be used.
40 amps. Single Pole
63 amps. Single Pole
80 amps. Double Pole
100 amps. Double Pole
125 amps. Double Pole
Supplying and manpower support in fixing following rating, three pole and four pole, 415 volts, isolator in the existing MCB DB comp lete with connections, testing and commissioning etc. as required. Note: ISI marked isolators shall be used.
40 amps. Tripple Pole
63 amps. Tripple Pole
80 amps. Tripple Pole
100 amps. Tripple Pole
125 amps. Tripple Pole
80 ams. Four Pole
125 amps. Four Pole
Supplying and manpower support in fixing following rating, double pole, (single phase neutral), 240 volts, residual current circuit breaker (RCCB/ELCB), ISI marked, having a sensitivity current indicated miliamperes in the existing MCB DB complete with connections , testing and commissioning etc. as required. Note: ISI marked RCCB/ELCB shall be used.
16 amps., 30 mA
16 amps, 100 mA
16 amps,, 300 mA
25 amps, 100 mA
25 amps,, 300 mA
32 amps., 30 mA
32 amps, 100 mA
32 amps,, 300 mA
40 amps,, 300 mA
63 amps,, 300 mA
Supplying and manpower support in fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB/ELCB), ISI marked, having a sensitivity current upto indicated milliamperes in the existing MCB DB complete with conne ctions, testing and commissioning etc. as required. Note: ISI marked RCCB/ELCB shall be used.
25 amps, 100 mA
25 amps,, 300 mA
40 amps,, 300 mA
63 amps,, 300 mA
Supply of following rating and breaking capacity 3 pole MCCB with thermomagnetic release alongwith terminal spreaders as per directi on of Engineer-in-Charge.
100 Amps, 16kA
125 Amps, 16kA
150 Amps, 16kA
Supply of following rating and breaking capacity 4 pole MCCB with thermomagnetic release along with terminal spreaders as per direct ion of Engineer-in-Charge.
100 Amps, 30kA
125 Amps, 36kA
Supply of MCB / Isolator/ RCCB/ELCB of following rating as per direction of Engineer-in-Charge.
25 amp modular SPMCB, ‘C’ curve
6 amps. to 32 amps. ratings , SP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , SPN MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , DP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , TP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , TPN MCB, “C” curve,10 KA breaking capacity
40 amps. to 63 amps. ratings , 3 Pole MCB, “C” curve,10 KA breaking capacity
40 amps. to 63 amps. ratings , 4 Pole MCB, “C” curve,10 KA breaking capacity
2 Amps, 10kA breaking capacity, 'C'Curve
40 Amps, 2 Pole Isolator
63 Amps, 2 Pole Isolator
40 Amps, 4 Pole Isolator
63 Amp, 4 Pole Isolator
100 Amp, 4 Pole Isolator
25 Amp, 2 Pole RCCB/ELCB, 30mA
40 Amp, 2 Pole RCCB/ELCB, 30mA
40 Amp, 2 Pole RCCB/ELCB, 100mA
63 Amp, 2 Pole RCCB/ELCB, 30mA
63 Amp, 2 Pole RCCB/ELCB, 100mA
25 Amp, 4 Pole RCCB/ELCB, 30mA
40 Amp, 4 Pole RCCB/ELCB, 30mA
40 Amp, 4 Pole RCCB/ELCB, 100mA
63 Amp, 4 Pole RCCB/ELCB, 30mA
63 Amp, 4 Pole RCCB/ELCB, 100mA
Supply, fixing and support in connection of following 240/415V, 50HZ, with 10KA short circuit capacity Residual current circuit brea ker with overload and short circuit protection (confirming to IS 12640-2:2001 & IEC 61009-2-1) of L&T /GEC Astholm/Standard /MDS/DAT AR/ HAVLES make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of E-I- C
Double pole(four module - 25 A ( SENSITIVITY 30 mA )
Double pole(four module - 25 A ( SENSITIVITY 100 mA )
Double pole(four module - 25 A ( SENSITIVITY 300 mA )
Double pole(four module - 40 A ( SENSITIVITY 30 mA )
Double pole(four module - 40 A ( SENSITIVITY 100 mA )
Double pole(four module - 40 A ( SENSITIVITY 300 mA )
Supply, fixing and manpower support in connection of following KNIFE TYPE (DIN) / BOLTED HRC fuse link AS PER IS:13703:1993 & IEC 26 9:1986 of M/S HAVELL/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.
20-32 AMP Size 000
50 AMP Size 000
63 AMP Size 000
80 - 100 AMP Size 000
125 AMP Size 00
125 AMP Size 1
160-200 AMP Size 1
315 / 400 Amps, size 2
315/400 Amps, size 3
500 Amps, Size 3
630 Amps, Size 3
800 Amps, Size 3
2-16 Amps, L&T HG type size F1
20-32 Amps, L&T HG type size F1
20-32 Amps, L&T, HQ type, size A1L
50-63 Amps, L&T, HQ type,size A1L
4-32 Amps, L&T, HQ type, size A2
35-63 Amps, L&T, HQ type, size A3
80-100 Amps, L&T, HQ type, size A4
125-160 Amps, L&T, HQ type, size A4
80-100 Amps, L&T, HQ type, size B1
125 Amps, L&T, HQ type, size B1
125-200 amps, L&T, HQ type size B2
250-315 Amps, L&T, HQ type, size B3
355-400 Amps, L&T, HQ type, size B4
400 Amps, L&T, HQ type, size C2
500 Amps, L&T, HQ type, size C2
630 Amps, L&T, HQ type, size C2
Supply, fixing and support in connection of following equipments in panels including small mechanical works and supply of all fixing materials. All complete with labour and materials as per the direction of Engineer-in-Charge
Control contactors- 4 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MX0 of L&T or equivalent
Control contactors- 8 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MX0 of L&T or equivalent.
Control contactors- 4 contacts for DC control standard coil voltage - 24, 110, 220 Type MX0 of L&T or equivalent
Control contactors- 4 contacts for DC control standard coil voltage - 24, 110, 220 Type MN0 of L&T or equivalent.
Power Contactor (Upto 2NO + 2 NC)- 40 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML3 of L&T or equivalent
Power Contactor (Upto 2NO + 2 NC)- 70 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML4 of L&T or equivalent
Power Contactor (Upto 2NO + 2 NC)- 110 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML6 of L&T or equivalent
Thermal Relays type L&T MN12 or equivalent, 42 - 69 A to 90 - 150 A (CT operated) with separate mounting
Thermal Relays type ML0/ML1/ML1.5 - 0.15 - 0.25 A to 10.0 - 16.0 A (Direct operated) contractor
Thermal Relays type ML2/ML3 - 9.0 - 14.0 A to 28.0 - 42.0 A (Direct operated) contractor
Mushroom actuator with holder pushbutton, Type:3SB, SIEMENS or equivalent as per direction of Engineer-in- charge.
Installation of Current Transformer of any rating
Supply of power contactor, 3 Pole, AC 3 Duty, 240 VAC, 50 Hz coil of following rating as per direction of Engineer-in-Charge:
25 Amps, L&T MNX25 or equivalent
32 Amps, L&T MNX32 or equivalent
45 Amps, L&T MNX45 or equivalent
70 Amps, L&T MNX70 or equivalent
95 Amps, L&T MNX95 or equivalent
140 Amps, L&T MNX140 or equivalent
400 Amps, L&T MNX400 or equivalent
25 Amps, L&T ML1.5 or equivalent
32 Amps, L&T ML2 or equivalent
Power contactor, 4 pole, 200A, L&T MCX 33, 2 NO+2 NC, Coil voltage:240 V AC, Cat no: CS 97021
Supply of Bimetal overload relay of following rating, make L&T MN-2 or equivalent as per direction of Engineer-in-Charge:
0.2 - 0.33 Amps to 0.6-1.0 Amps
0.9-1.5Amp to 6-10 Amps
Supply of Bimetal overload relay of following rating, make L&T MN-5 or equivalent as per direction of Engineer-in-Charge:
Supply of Bimetal overload relay, Range 6-10 Amps, for L&T make ML1.5 contactor or equivalent
Supply of Bimetal overload relay, Range 9-14 Amps, for L&T make ML 2/3 contactor or equivalent
Supply of Spare Contact Kit for contactors of following type as per direction of Engineer-in-Charge:
Power contactor L&T ML1.5 or equivalent.
Power contactor L&T ML2 or equivalent.
Power contactor L&T ML3 or equivalent.
Power contactor L&T MNX 32 or equivalent.
Power contactor L&T MNX 40 or equivalent.
Power contactor L&T MNX 70 or equivalent.
Supply of Spare coil for contactors of following type as per direction of Engineer-in-Charge:
L&T ML1.5, Cat No. SS90873 or equivalent
L&T ML2/3, Cat No. SS90545 or equivalent
L&T MNX70, Cat No. CS94192 or equivalent
Supply of Add on auxiliary contact block for contactors of following type as per direction of Engineer-in-Charge:
L&T MNX 9-80, front mounting, 2NO+2NC, Cat No. CS94114 or equivalent
L&T MX-A1 front mounting, 2NO+2NC, Cat No. CS94035 or equivalent
Supply of spreader terminals for MCCBs (make L&T or equivalent) of following rating & type.
125/250 Amps, 3 Pole
400 Amps, 3 Pole
630 Amps, 3 Pole
250 Amps, 4 Pole
400 Amps, 4 Pole
Supply and fixing of led indication lamp in the panels. leds shall be provided with leakage voltage protection upto 40v. Operating v oltage shall be 110V / 220V / 230V /AC /DC, Panel cutouts shall be 22.5 / 25.5 / 30.5 mm. Terminals shall be shrouded for finger pro ofing and safety are with captivated washers to hold two lugged (fork / pin) wires in one terminal. Job includes supply of labor and various undry materials required and finally testing of led's for + following ed's
Red / yellow / amber / green / milky white led's
Blue led
PROVIDING COPPER LUGS FOR MAINTENANCE Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equiva lent certified by EIC. of the following sizes.: Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes.
PROVIDING ALUMINIUM LUGS FOR MAINTENANC Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or e quivalent certified by EIC. of the following sizes.: Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowe lls make or equivalent certified by EIC. of the following sizes.
PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS Supply of CMRS / CCE approved flameproof double compression (brass) cab le gland for following overall cable sizes as per directions of Engineer-in-Charge.: Supply of CMRS / CCE approved flameproof double compression (brass) cable gland for following overall cable sizes as per directions of Engineer-in-Charge.
PROVIDING SINGLE COMPRESSION (BRASS) CABLE GLANDS Supply of single compression (brass) heavy duty type cable gland for following ove r all cable sizes as per directions of Engineer-in-Charge.: Supply of single compression (brass) heavy duty type cable gland for fol lowing over all cable sizes as per directions of Engineer-in-Charge.
LT STRAIGHT THROUGH CABLE JOINT FOR ARMOURED PVC INSULATED CABLE (INCLUDING COST OF JOINT KIT OF CAST RESIN TYPE WITH IS MOULD): Mak ing straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, stripping of cable insulation, including supply of cast resin straight through cable jointing kit with IS mould of Mahindra /CCI/ approved equ ivalent make with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-cha rge.
2 x upto 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x upto 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
3-1/2 x upto 6 sqmm
3-1/2 x 10 sqmm
3-1/2 x 16 sqmm
3-1/2 x 25 sqmm
3-1/2 x 35 sqmm
3-1/2 x 50 sqmm
4 x upto 6 sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
LT STRAIGHT THROUGH CABLE JOINT FOR ARMOURED PVC INSULATED CABLE (INCLUDING COST OF JOINT KIT OF HEAT SHRINKABLE TYPE): Making strai ght through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, stripping of cable insulation, including supply of heat shrinkable TUBULAR straight through cable jointing kit of Raychem / CCI / approved equivalent m ake with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer in-charge.
Upto 3 / 3.5 / 4 x 6 sqmm
3 / 3.5 / 4 x 10 sqmm
3 / 3.5 / 4 x 16 sqmm
3 / 3.5 / 4 x 25 sqmm
3 / 3.5 / 4 x 35 sqmm
3 / 3.5 / 4 x 50 sqmm
LT CABLE HEAT SHRINKABLE INDOOR / OUTDOOR CABLE END TERMINATION (INCLUDING COST OF END TERMINATION KIT): Providing end termination o f power cable including cutting, stripping, providing lugs, cable insulation, providing and glanding with single/double compression heavy duty brass cable gland conforming to IS-12943 , wherever specified, providing aluminium lugs, crimping/soldering, as necessary , restoration of insulation/ clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. Make of kits shall be of Raych em/ CCI/ approved equivalent make.
Upto 3 / 3.5 / 4 x 10 sqmm
3 / 3.5 / 4 x 16 sqmm
3 / 3.5 / 4 x 25 sqmm
3 / 3.5 / 4 x 35 sqmm
3 / 3.5 / 4 x 50 sqmm
LT OUTDOOR END TERMINATIONS FOR ARMOURED/ PVC INSULATED CABLE (INCLUDING COST OF CAST RESIN END TERMINATION AND LUGS): Providing end termination of power/control cable including cutting, stripping, fixing lugs, crimping/soldering, with cast resin end termination, restoration of insulation/clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals e tc. all complete with labour and materials as per standard and direction of the Engineer-in-charge.
2 x 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
3 - 1/2 x 10 sqmm
3 - 1/2 x16 sqmm
3 - 1/2 x 25 sqmm
3 - 1/2 x 35 sqmm
3 - 1/2 x 50 sqmm
Support in LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH SINGLE COMPRESSION BRASS GLANDING (EXCLUDING COS T OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, fixing lugs, cable insulation, & glanding with single compression heavy duty brass cable gland wherever specified, fixing aluminium lugs for power cables and copper connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminiu m tag,earthing of armour, manpower support in connection to the equipment terminals etc. all complete as per standard and direction of the Engineer-in-Charge.
2 x 6 sqmm
2 x 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x 4 Sqmm
3 x 6 Sqmm
3 x 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
4 x 4 Sqmm
4 x 6 Sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
3 x 2.5 sqmm LT control cables with copper lugs
5 x 2.5 sqmm LT control cables with copper lugs
7 x 2.5 sqmm LT control cables with copper lugs
10 x 2.5 sqmm LT control cables with copper lugs
12 x 2.5 sqmm LT control cables with copper lugs
14 x 2.5 sqmm LT control cables with copper lugs
16 x 2.5 sqmm LT control cables with copper lugs
19 x 2.5 sqmm LT control cables with copper lugs
3-1/2 x 25 sqmm
3-1/2 x 35 sqmm
3-1/2 x 50 sqmm
Supply of three phase digital ammeter, 0-1000A, 1/5 A,Class- 0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
Supply of Three phase digital voltmeter, Class-0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
Supply of rotary handle (extended ROM) for MCCBs (make L&T or equivalent) of following rating
Supply of Fuse Base of following types as per direction of Engineer-in-Charge:
Fuse Base L&T HD32B Cat No. ST30735 or equivalent
Fuse Base L&T HK63B cat No. ST30763 or equivalent
Fuse Base L&T HK125B cat No. ST30771 or equivalent
Supply, fixing and support in connection of following Fuse base (HOLDERS) for HRC fuse link of M/HAVELL'S/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-c harge.
20 AMP ( H-Front/B_Bus Bar Connection ) -FOR FUSE TYPE HNS
32 AMP ( H-Front/B_Bus Bar Connection) -FOR FUSE TYPE HTIA
63 AMP ( H-Front/B_Bus Bar Connection) -FOR FUSE TYPE HTSS
100 AMP ( Front Connection) -FOR FUSE TYPE HTSD
100 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
125 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
250 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-1
400 AMP ( Open Type Fuse Base) FOR FUSE TYPE CD-2
630 AMP ( Open Type Fuse Base) FOR FUSE TYPE CD-3
Supply of accessories for transformers
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 750gm silicagel as per direction of Engineer-in-Ch arge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-C harge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-C harge.
Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge.
Supervision & Logistic Charges @ 15% of the total manpower charges excluding Liveries Payment
PMBPL Baitalpur
CIVIL Maintenance Works
Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.
Earth work by mechanical / manual means in rough excavaton in all kinds of soil, banking excavated earth, breaking clods, watering,c ompacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in laye rs not exceeding 20 cm thickness and dressing up in embankments for roads, food banks, marginal banks and guide banks or flling up g round depressions, up to all leads and lift.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of su rplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : Pipes, cables etc, not exceeding 80 mm dia.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of su rplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Clearing the area of grass, rank, vegetation, wild growth bushes, trees and plants up to 30 cm. girth measured at a height 1.0 m abo ve ground level from roadside berms, under side of pipelines, under the structures, tank farms, drains, railway exchange yard etc. i ncluding removal of grass, plants and rubbish etc. by cutting with Darant/sickle(hansua) etc. completely near to ground level (The s hoots remaining should not be more than 5cm in height) as per directions of engineer-in-charge and collecting all cut grass, vegetat ion etc. and bundling in to heaps and disposing at earmarked places only within a lead of 3 km with contractor's own transport with all tools, tackles, labour etc. complete as per specifications and directions of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer: 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources]
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer: 1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in al l respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Eng ineer:
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from n atural sources]
Providing and laying structural reinforced cement concrete work (1:1.5:3) conforming to IS:456 (1 cement : 1.5 coarse sand : 3 grade d stone aggregate 20 mm nominal size) at all heights and depth for construction of foundations, beams, columns, staircases, chajja,l intels, balconies, shelves, plain window sills, roof slabs, facia, canopies, fins, porch, water tank etc. including providing center ing, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclu sive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. (Payment for Reinforcement shall be made as per relevant item of SOR).
a) All work up to plinth level
b) In superstructure at all floors up to floor five level
Steel reinforcement for R.C.C. workincluding initial straightening of coiled/uncoiled bars, removal of loose rust, cutting, bending to correct size & shape, binding with 18 gauge G.I. wire at each intersection and placing at any position, at any height and depth c omplete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directio n of Site Engineer. : Thermo-Mechanically Treated bars of grade Fe-500 D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1: 4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1: 6 (1 cement : 6 coarse sand
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length [Note: Hold fast lugs or Dash fasteners shall be paid separately und er relevant item of SOR] : Second class teak wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length [Note: Hold fast lugs or Dash fasteners shall be paid separately und er relevant item of SOR] : Sal wood
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For F ixed portion -Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of Gra de AC-15
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For f ixed portion Powder coated aluminium (Minimum thickness of powder coating 50 micron
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For f ixed portion Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and simi lar works, including applying priming coat of approved steel primer : MS Tube
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and simi lar works, including applying priming coat of approved steel primer : GI Pipe
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, b uffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts comple te, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of require d size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-Charge. [Note : For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, f asteners etc.]
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirt ing, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement sl urry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Ceme nt : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption' s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 c ement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :C oupler 110 mm
CEMENT PLASTER (IN COARSE SAND) Rates for external 12 mm cement plaster. 1:6 (1 cement: 6 coarse sand)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Pain ting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of p rimer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Pain ting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape , raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping grou nd within 50metres lead With cement mortar 1:4 (1cement: 4 coarse sand).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obta ined. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]: Nominal con crete 1:3:6 or richer mix (including equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work as per direction of the Engineer-in-Charge . [Notes: (1) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-i n-Charge. (2) Payment shall be made on the cross sectional area of R.C.C. or R.B. work
Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including l oading, transporting, unloading to designated location/ approved municiple dumping ground for lead up to 10 Km and for all lifts, co mplete as per directions of the Engineer-in-Charge. [Note: This item shall also be applicable in urban areas having directions for r estricted hours for movement/ plying of load carrying motor vehicles of 3.5 cum or more.]
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dump ing ground within 50 metres lead.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixture s complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic s eat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, includi ng painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x4 50 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 15 mm nominal dia pipes
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 20 mm nominal dia pipes
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 25 mm nominal dia pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 15 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work – E xposed on wall 25 mm dia. nominal bore
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as p er standard design
Supply of 10 HP Diesel driven dewatering pump with all accessories including hoses along with one operator for dewatering .The job i nvolves pumping out of water including dewatering oily trenches, pits,excavated areas etc. by contractor's own pump as per the direc tion of the Engineer-in-charge.The job also includes supplying of pump, tools & tackles,hoses, fuel,all consumables and labour to co mplete the job in all respects as per EIC(for maximum of 8 Hrs per shift).
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleanin g machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operato r, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing o f sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia up to 300 mm dia for all depth
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the ground
Pruning, trimming, shaping of trees/ shrubs (height 15 feet & above) and removal of cut materials up to 50m lead inclusive of all la bour, T&P, materials etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TREE"].
Removal of garden waste by TATA 407 or equivalent capacity vehicle including loading/ unloading, carriage up to 1.0 Km lead & dispos al at designated place etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TRIP"].
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 80mm thick Cement Concrete paver block of M-30 grade with approved colour, design & pattern
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge : 100mm thick Cement Concrete paver block of M-50 grade with approved colour, design & patter n.
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 15 mm nominal dia pipes
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 20 mm nominal dia pipes
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge : 25 mm nominal dia pipes
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron "P" or "S" trap, 10 litre low lev el white P.V.C. dual flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS:7231, w ith all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White vitreous ch ina orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I cl amps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One uri nal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing White Vitreous China Wash basin size 550x400 mm with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing White Vitreous China Flat back wash basin size 550x400 mm with C.I. brackets, single 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing White Vitreous China pedestal for wash basin completely recessed at the back for the reception of pipes and fit tings
Providing and fixing White glazed fire clay kitchen sink of size 600x450x 250 mm with C.I. brackets, C.P. brass chain with rubber pl ug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever requir ed :
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of app roved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of app roved make and shade with 6 mm thick hard board backing: Rectangular shape 1500x450 mm
Providing and fixing PTMT Bottle Trap for Wash basin and sink : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and c olour, weighing not less than 105 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good th e same with cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary pla ster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 50 mm diameter
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 50 mm nominal dia pipes
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of the Engineer-in -Charge : Door chowkhats
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of the Engineer-in -Charge : Clerestory window chowkhats
Supply of tractor with trailer on hire charges for 08 hours per day including rendering the services of 4 labourers driver, fuel and other consumables, tools, tackles etc. for transportation of rubbish/ waste materials complete as per directions of Engineer-in-Cha rge.(8 hours working period of one tractor is considered as one tractor day). Unit "EACH" (EA) stands for tractor days.
Brass floor door stopper: Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS:3564 em bossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with neces sary accessories and screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embo ssed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing Housekeeping, Horticulture and Environment Management
Liquid hand wash dettol (200 ml handwash pump)
Toilet Air freshner Odonil (50 gram for thirty days )
Harpic tolet cleaner (500 Ml)
Lizol Disinfectant Surface Cleaner Citrus (1 L)
Napthalene Balls
Cleaning acid(Muritac acid)for bathroom tiles
Cleaning duster
CoConut Bamboo broom
Green brass broom (Full jhadu)
Flat mop wet and dry cleaning (24 inch)
Mopping cloth
Spin Mop Bucket (Milton brand or Equivalent)
Floor wiper (Brand -Scotch brite or equivalent size 40 cm )
Urinal screen mat with fragrances
Room freshner (200 ml ,Brand-godrej aer or equivalent)
Collins mirror cleaning(500 ml)
Hand towel for toilet (Brand-Raymond or equivalent , Size-40*60 cm)
Fiber bathroom scrubber brush (Brand Scrotch brite or equivalent )
Toilet cleaning brush
Mosquito repellent and machine (good night)
Office room stainless steel Dust bin (Brand -Prestige or equivalent size-12 liter)
Outdoor stainless steel dustbins (Brand -Milton/Prestige or equivalent size-40 liter)
Horticulture
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 Nos horizontal & 4 Nos vertical “U“ shape) M.S. wires of 3.5 m m dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of the Engineer-in-Charge. Top inside diameter 30 cm, outer botto m diameter 20 cm, total height 30 cm with wall thickness of 25.4 mm
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Tree Plant
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Shrub Plant
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water): Hedge Plant/ Ground Cover
Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas,Mango, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants/fruit-bearing Tree, watering & maintenance fo r 30 days minimum complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
Providing and watering of Horticulture features i.e. lawn, tree, shrubs, hedge/ edge, ground cover etc. with irrigation water at the site of work. Watering shall be done through water tanker having 5000 litre capacity with one labour for watering including cost of water, filling of tanker, watering at site with all leads and lifts as per direction of the Engineer-in-Charge. [Note: Unit "EA" sh all mean "PER TRIP"].
Cleaning and Sweeping of Lawn/ Garden area and keep it neat & clean by mechanized method/ manually, removimg litter, debris, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per direction of the Engineer-in-Charge. [Note: All T&P, materials/ articles shall be provided by the Contractor].
Cleaning the tiles, lavatory, flooring, urinals etc. by removing stains etc. by using Vim powder / cleaning powder / ISI grade black phenyle / while phenyle / Acid /Naptha balls / Coir brushes / wire brushes / Finit in required proportion to make the area clean an d free from all dust, dirt and stains etc. including cost of all labour and materials complete. (Only floor area shall be measured).
Mopping of floors of offices, toilets, control rooms, electrical sub station etc. with soap solution or phenyle water with wet cloth after sweeping the floor with phooll broom, removing cob-webs with all tools, tackles, labour & materials etc. complete as per dire ctions of Engineer -in-charge including cleaning of ventilator glass panes from both the sides upto any height with cleaning powder, paint remover as per requirement all labour, material etc.complete.
Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning po wder, paint remover as per requirement all labour, materials etc. complete. Glass pane not exceeding 1.00 sq.m in area
Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning po wder, paint remover as per requirement all labour, materials etc. complete. Glass pane exceeding 1.00 sq.m in area
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per th e directions of Engineer-in-Charge.
Providing comprehensive pest control services to the building, sheds, cable trenches, drains and other facilities of the establishme nt, to control the nuisance of various pests including (but not limited to) rodents, snakes, lizards, beehives, cockroaches, mosquit oes, Red and Black ants, crawling pests, house flies, fruit flies, etc. Job includes placing / injecting rodenticide baits, glue tra ys, snake repellent and other chemicals, insecticides, Fogging/fumigation, Removal of bee hives below ground (in trenches upto depth of 1m) and above ground (up to height of 15m), complete with all labours, materials, tools, and tackles, equipments, consumables et c complete. Periodicity of scheduled pest control activities shall be monthly, while ad hoc requirement shall be as and when require d as directed by EIC whose decision shall be final. Area of measurement for pest control application shall be designated by EIC. Rat e is For (PER SQM PER MONTH)
Providing toiletries (including mosquito repellent in each room) for cleaning and hygiene service as per SCC. Payment for this item will be paid on actual basis on production of relevant bill.
Up keep of equipment`s & appliances
Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commerc ial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddl e supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc. , sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour , materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.
PU /liquid epoxy Coating of under ground piping Cleaning exposed steel surfaces of piping, equipment and valves etc. by abrasive bla sting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying si ngle layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.
Providing Hydra ( 10-12 TON capacity ) along with belts, chains, hooks etc at site for shifting heavy material or equipments like pi pes, welding machine, cold cutting machine etc.The rate is inclusive of mobilisation and demobilisation cost, hiring and running cos t, fuels, consumables, lube oil cost, operator cost etc., as per direction of EIC. Payment towards equipment running charges shall b e made only if payments are not covered in any of the SOR items elese where in this contract.
Providing welder, cutter, grinder team
Providing & operating JCB for earth work in excavation in both ordinary & Rocky soil for ROW cleaning, washout rectification/ instal lation ofanode ground bed, sacrificial anodes, cable trenches, pipelinetrenches, etc. including backfilling the same after completio n of workin all respect and up to the satisfaction of Site Engineer / EIC & thecost includes all labour, materials complete as per d irection of SiteEngineer/ EIC.
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment Removing loose scales,blisters etc from ol d painted surface by scrapping with wire brush thoroughly and smoothening the surface to make it suit- able for receiving fresh coat of paint
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment. Application of one coat ready mixed oil b ased red oxide zinc chromate primer
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoot hening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment. Application of Two or more coats of any s hade of Aluminium Paint
Electrical ARC
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of sit e engineer / Engineer-in-Charge:
Supply and fixing of following size of PVC conduit alongwith the accessories in surface including conduit as required: Note: Only IS I marked conduits shall be used.
PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.:
Providing and fixing following size of PVC casing and caping on surface as required. Note: Only ISI marked caping and casing shall b e used.
15 mm x 10 mm
20 mm x 10 mm
25 mm x 10 mm
30 mm x 10 mm
40 mm x 20 mm
50 mm x 20 mm
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge:
Power cables LT : OD upto 20 mm
Power cables LT : OD above 20 mm and upto 40 mm
Power cables LT : OD above 40 mm and upto 60 mm
Power cables LT : OD above 60 mm
Power Control cables LT : OD upto 20 mm
Control cables (T&I) : OD upto 20 mm
Control cables (T&I) : OD above 20 mm and upto 30 mm
Control cables (T&I) : OD above 30 mm and upto 40 mm
Supplying and drawing following size of FRLS PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC / steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used.
1 x 1.5 sq.mm
2 x 1.5 sq.mm
3 x 1.5 sq.mm
4 x 1.5 sq.mm
5 x 1.5 sq.mm
6 x 1.5 sq.mm
7 x 1.5 sq.mm
8 x 1.5 sq.mm
9 x 1.5 sq.mm
10 x 1.5 sq.mm
2 x 2.5 sq.mm
3 x 2.5 sq.mm
4 x 2.5 sq.mm
5 x 2.5 sq.mm
6 x 2.5 sq.mm
7 x 2.5 sq.mm
8 x 2.5 sq.mm
9 x 2.5 sq.mm
10 x 2.5 sq.mm
2 x 4 sq.mm
3 x 4 sq.mm
4 x 4 sq.mm
5 x 4 sq.mm
6 x 4 sq.mm
7 x 4 sq.mm
8 x 4 sq.mm
9 x 4 sq.mm
10 x 4 sq.mm
2 x 6 sq.mm
4 x 6 sq.mm
5 x 6 sq.mm
6 x 6 sq.mm
7 x 6 sq.mm
8 x 6 sq.mm
9 x 6 sq.mm
10 x 6 sq.mm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed steel conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in surface steel conduit a s required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed, PVC medium du ty conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in surface PVC medium duty conduit as required. Note: Only ISI marked conduits & cables shall be used.
2 x 10 sqmm with 6 sqmm earth wire
2 x 16 sqmm with 6 sqmm earth wire
2 x 25 sqmm with 6 sqmm earth wire
4 x 10 sqmm with 2x6 sqmm earth wire
4 x 16 sqmm with 2x6 sqmm earth wire
3x25 + 1x16 sqmm
Supply, fixing and connection of 250 V below given mosaic modular wiring accessories of M/s MDS or approved equivalent inlcuding sup plying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
6 amps. - 1 way - SP - 1 module switches
10 amps. - 1 way - SP - 2 module switches
16 amps. - 1 way - SP - 1 module switches
6 amps. - 1 way - SP - 1 module push button
Two module stepped type electronic fan regulator 100W
6 amps. - 2 / 3 pins combined 2 module shutterred socket
6 amps. - 3 pins combined 2 module shutterred socket
6 / 16 amps. - 3 pins combined 3 module shutterred socket
16 amps. - 3 pins - 3 module switch socket
1 module blanking plate
6 pin 25 A modular type socket lSI Marked
Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 module
2 module
3 module
4 module
6 module
8 module
12 module (6 x 2)
18 module (6 x 3)
Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 / 2 module
3 module
4 module
6 module
12 module (6 x 2)
8 module
Supply and fixing of below given metal surface boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlc uding supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
1 / 2 module
3 module
4 module
6 module
12 module (6 x 2)
8 module
Fixing of wall monted fan completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of Fans shall be excluded)
Fixing of exhaust fans on existing opening, complete with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in- Charge. (cost of fans shall be excluded)
WITHOUT LOUVER SHUTTER/MESH
FLP/IS EXHAUST FAN
Numbering of ceiling fan, exhaust fan and flourescent fittings as required.
Extra for fixing the louvers / shutters complete with frame for exhaust fan of all sizes
Repainting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved bra nd and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
Installation, testing and commissioning of ceiling fan and regulator including wiring the down rod of standard length (upto 30 cm) w ith 1.5 sqmm, PVC insulated, copper conductor, single core cable etc. as required.
Fixing of following light fittings attachments on MS hanger/supports/concrete wall structure /steel structure completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of light fitti ngs/lamp control gears and other fittings shall be excluded). [work to be carried out only in deenergized state]
(FLP/INCREASED SAFETY) (WELLGLASS/ BULKHEAD/ TUBELIGHT)
RECESSED TUBELIGHT FITTING
ORDINARY BULKHEAD/PL TYPE FITTING
STREET LIGHT FITTING (UPTO 9 M HEIGHT)
STREET LIGHT FITTING (MORE THAN 9 M HEIGHT)
FLOODLIGHT WITHOUT CONTROL GEAR (UPTO 9 M HEIGHT)
CONTROL BOX (UPTO 9 M HEIGHT)
FLOODLIGHT WITHOUT CONTROL GEAR (MORE THAN 9 M HEIGHT INCLUDING ON FLDM)
CONTROL BOX (MORE THAN 9 M HEIGHT INCLUDING ON FLDM)
Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SYSKA/Oreva/Crompton or equivalant Indian make). Item includ es Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc.. [w ork to be carried out only in deenergized state]
9W, LED Tube Light Fitting, 2FT, 230V AC
15W, Outdoor LED Light Fitting, IP55, 230V AC
40W LED Light/Lamp, 230V AC, 50Hz
120W LED Flood Light Fitting, with IP65, 230V AC, 50Hz
40W Flameproof LED Well Glass Light Fitting, 230V AC, 50Hz
LED Light Driver of Flood Lights (complete set replacement for 350W and above Flood Light with specifications in conformance to orig inal light drivers)
18W, LED Tubelight Fighting, 230V AC, 50Hz
09W, LED Bulb/Lamp, 230V AC, 50Hz
15W, LED Bulb/Lamp, 230V AC, 50Hz (indoor)
200W LED weatherproof Flood Light Fitting,, 230V AC, 50Hz
Supply & support in installation of elmex terminals supply and support in fixing and connecting elmex type terminals wherever requir ed. job includes drilling holes, providing and fixing clamps, nuts and bolts etc. suitable for terminating 2.5 mm2 copper conductor. job should be carried out as per drawing.( per terminal )
Supply and support in fixing and connecting channels for elmex type terminals wherever required. job includes drilling holes. provid ing and fixing clamps, nuts and bolts etc.
LIGHTING CONTROL
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-non regulated programmable
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-regulating programmable with day light di mming
Supply, installation,testing and commissioning of occupancy sensor based on microwave technology-non regulated programmable
Supply, installation,testing and commissioning of astronomical time switch (Electronic Timer) for single phase supply with 1 output per phase
Supply, installation,testing and commissioning of astronomical time switch for single phase supply with 2 outputs per phase
Supply, installation,testing and commissioning of astronomical time switch for three phase supply with 1 output per phase (total 3 o utputs)
Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and i nstallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other requir ed materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from t he approved make list given in the specifications:
Tube light fitting type Quadra 2 BBS805 2 X LLM 1800/840 PSU-E 220V-240V LED luminaire of PHILLIPS or approved make, complete with a ll accessories suitable for mounting in false ceiling as per the directions by EIC / Site Engineer.
LED Ceiling Point: Supply and fixing of surface mounted LED ceiling light fitting type Mainstream spot Aura 15W of PHILLIPS or equiv alent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including i nstallation.
WP Endura LED: Supply and fixing of surface mounted weather proof Endura LED WT 550 light fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation.
LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equivalent approved make with LEDs: Suppl y and fixing of recess mounted weather proof light Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equiavlent approved make with LE Ds, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIPS or equivalent approved make complete with all accessori es such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.
LED light fittings with LEDs, Sereno LED-Suspended-SP824 P LED 30S-5000 GR OD or approved equivalent:Supply and fixing of surface mo unted weather proof light SP824 P LED 42 W having 2950 lumens output fitting of PHILLIPS or equivalent approved make complete with a ll accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved ma ke.
LED light fittings, Batten with 2XTLED-TMC501-2X TLED-36 W P3242 or equiavlent approved make with LEDs: Supply and fixing of wall mo unted/ suspended type weather proof light 2XTLED-TMC501-2X TLED or equiavlent approved make with LEDs, 36 W or more. LED Fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector block s etc including installation with LED of approved make.
Critical Light: Non Flame Proof type PEL 240 M/SL of Prolite or of approved make as per EIC, with 2 X 18 W LED TL/ Lamp including se aled lead acid battery of suitable size for minimum 01 hour back up, battery charger, for Fire fighting pump shed, HT/LT Room, Batte ry Room etc.The job includes connection of the fitting, 6A switch socket with 2C x 4 sqmm cable from DB/switch board and as mentione d above including all accessories etc. complete in all respect as per direction of EIC / Site engineer.
FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group II A & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified en closure:
FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007
FLAMEPROOF LED WELL GLASS FITTING 90 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Well Glass Light Fixture with provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compressi on type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED FLOOD LIGHT FITTING 90 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED FLOOD LIGHT FITTING 45 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
Critical Light: Flame Proof & Weather Proof supply, erection (fixing the same on roof truss, wall, column etc. as required), termina tion of 240V, flame proof light fittings with heat resistant glass diffuser and suitable for LED lamp, IP65, of model PEL 111 Prolit e make or equivalent approved makes as per EIC. The job includes the cost of fitting and erection 1 no. LED lamp 18W, Ni-Cd battery of suitable size for minimum 01 hour back up, battery charger, earthing, supply & erection of all accessories, suitable MS brackets etc. complete.
Rewinding of ceiling/pedestal/exhaust/air circulator fans of all types/sizes/make including 1-phase and 3-phase type exhaust fans ma x. upto 2.2 KW capacity and supply of super enameled winding wire (Devi Dayal make, ISI marked insulation materials required). This also includes replacement of single/double bearing SKF make/bushes (as per original make) and overhauling of fan and all jobs relate d to complete this work in totality. This also includes removal of fans from site, installation and commissioning after testing of r ewound fans and replacement of condenser, if required. This also includes transportation from site after dismantling to Contractor’s workshop and back to site. Note: Contractor has to give guarantee for rewinding of above items for a period of six months and if wi nding is burnt again within six months of working of fans, it has to be rewound again of Contractor. The burnt winding shall be kept by Contractor.
Ceiling/pedestal fans
Exhaust/air circulators fans.
Overhauling of exhaust/air circulator fans of various types/sizes makes and its bearings including removal from site, cleaning, grea sing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back all complete with labour and materials as per directions of Engineer-in-Charge.
Excluding the cost of bearings (Bearings if necessary will be supplied by Owner ).
Including supply and fixing of bearings of SKF make (02 Nos. bearings)
Overhauling of ceiling/pedestal fans of various types/ sizes/make and its bearings including removal from site, cleaning, greasing a fter degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and ba ck. All complete with labour and materials as per directions of Engineer-in-Charge.
Excluding the cost of bearings. (Bearings if necessary will be supplied by Owner .
Including supply and fixing of bearings of SKF make and bushes (as per original make) of both sides by Contractor.
Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
CU,2CX2.5 mm²,2XWY
CU,3CX2.5 mm²,2XWY
CU,3CX4 mm²,2XWY
CU,6CX2.5 mm²,2XWY
CU,12CX2.5 mm², 2XWY
CU,2CX4 mm²,2XWY
CU,4CX4 mm²,2XWY,
CU,3CX6 mm²,2XWY
CU,2CX10 mm²,2XWY
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overal l sheathed, Stranded, FRLSH, C2, Smoke density<40%
AL,3CX10 mm²,A2XFY
AL,3CX16 mm²
AL,4CX10 mm²,A2XFY
AL,4CX16 mm²,A2XFY
AL,3CX25 mm²,A2XFY
AL,3.5CX25 mm²,A2XFY
AL,4CX25 mm²,A2XFY
AL 3C x 35 mm²
AL,3.5CX35mm²,A2XFY
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make
Copper Cable size 1cx25 sq.mm Armoured
Copper Cable size 2cx6 sq.mm Armoured
Copper Cable size 2cx25 sq.mm Armoured
Copper Cable Kynar/HMWPE size 1cx10 sq.mm Unarmoured for distributed anodes of station CP system
CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grad e control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glan ds, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying.
16C x 2.5 sq. mm. Cu. Control cable
12C x 1.5 sq. mm. Cu. Control cable
6C x 1.5 sq. mm. Cu. Control cable
4C x 2.5 sq. mm. Cu. Control cable
EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earth ing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing elect rodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-char ge, including the cost of all labour, tools, materials, etc. complete in all respect:
50 mm X 6 mm G.I. earthing strip
40 mm X 5 mm G.I. earthing strip
25mm x 4 mm copper flat
25mm x 3 mm copper flat
GI wire (8 SWG)
GI wire / rope 35 sq. mm
GI wire / rope 10 mm diameter
Copper cable as per specifications - 10 Sq.mm
Providing salt and charcoal for plate earth electrode as required.
96 kg charcoal and 5 kg salt
240 kg coke and 5 kg salt
Providing salt and charcoal for pipe earth electrode as required.
64 kg charcoal and 5 kg salt
160 kg coke and 5 kg salt
Providing Earthing with bare stranded tinned copper flexible conductor including providing and connecting equipments with earth busb ar, supply and fixing of copper stranded wire of following sizes and making connection with equipment by means of GI bolts, nuts, wa shers, copper lugs etc. all complete with labour and materials as per direction of Engineer-in-Charge.
Providing earthing with copper plate as per IS: 3043 standard / drawing / specification with plate size 600 mm x 600 mm x 3 mm plate materials tinned copper plated with drilled hole at centre to receive 50 mm long 13 mm bolt, nut and double washer screwing system with copper tape/copper flexible. The tape/flexible shall be inside 1 1/2" dia GI pipe length from copper plate to the system to be earthed. The Plate shall be burried at a minimum depth of 4.5 Mtr below ground level on its edge and 2 Mtrs away from building/equip ment foundation and shallbe connected to the equipment. The size of the copper flexible shall be not less than 19 mm x 1.6 mm. The i tem includes labour and materials all complete (but without coke or charcoal and salt). Charcoal and salt cost will be paid seperate ly as extra.
Providing earthing with GI plate as per IS: 3043 standard / drawing / specification with plate size 600 mm x 600 mm x 6 mm thick pla te with drilled hole at centre to receive 50 mm long 13 mm bolt, nut and double washer screwing system with GI tape / GI flexible. T he tape / flexible shall be inside 1 1/2" dia GI pipe length from GI plate to the system to be earthed. The Plate shall be burried a t a minimum depth of 4.5 Mtr below ground level on its edge and 2 Mtrs away from building/equipment foundation and shall be connecte d to the equipment. The size of the GI flexible shall be not less than 19 mm x 3 mm. The item includes labour and materials all comp lete (but without coke or charcoal and salt). Charcoal and salt cost will be paid seperately as extra.
Providing and fixing of lightning conductor finial, made of 25mm dia. 300mm long, copper tube, having single prong at top, with 85mm dia. 3mm thick copper base plate including holes etc. complete as required.
Providing and fixing of lightning conductor finial, made of 25mm dia. 300mm long, GI tube, having single prong at top, with 85mm dia . 6mm thick GI base plate including holes etc. complete as required.
Fixing of lightning conductor finial made of 24mm dia. 300mm copper tube / GI tube, having single prong at top, complete with base e tc. as required.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. co mplete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. comp lete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the m ain earthing grid.
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 4 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. comp lete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the m ain earthing grid.
Spreading the stone chips per CUM
Temporary laying and dismantling of following cables (armoured/ unarmoured, power/control/ telecommunication/ computer) of different voltage grades/sizes/types for temoprary connections during shutdown etc., including transportation of cable from stores/another si te and returning the same after dismantling to store, all complete with labour and materials as per directions of the Engineer-in-Ch arge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Cleaning of below given fitting fixtures alongwith perfex cover (wherever applicable) with the help of surf powder. It includes the removal of perfex cover, washing the lighting fixture with powder, cleaning with fresh water and clothes and refixing in the same po sition. It also includes arranging ladder as and wherever required, providing scaffolding at all heights with necessary tools & tack les. All complete with labour and materials as per directions of the Engineer-in-Charge.
Tube light fitting/ceiling/exhaust fan/fan at any height inside a building.
MLL/HPMV/HPSV lamp of FLP /increased safety/ weather proof or any other similar fittings upto 250 W
Support in Connection and disconnection of Hand lamp/grinder/wooden boards of different sizes with any No. of switch/sockets of diff erent ratings, etc (small equivalent equipments). with flexible wire of sizes 1.5 sq.mm/2.5 sq mm / 4 sqmm including to and fro tran sporting it to Owner’s store or any other place.. All complete with labour and materials as per directions of the Engineer-in-Charge . NOTE Hand lamps / flexible wire are to be supplied by Owner. Consumables like PVC tape, CTC, cleaning cloth are to be supplied by Contractor.
Support in Cleaning of complete PCC/MCC panels. It includes opening of side top covers, removal of dust by vacuum cleaners/blowers e tc., checking and tightening of screws, nuts, bolts, washers & connections, application of petroleum jelly and boxing up of the pane ls. All complete with labour and materials as per directions of the Engineer-in-Charge.
Support in Repair/replacement of kit/kat/HRC fuse bases of different sizes in feeder pillars, main switches, substations, pump house s, residential buildings, public buildings, hospitals, clubs, schools, shopping center and at any other place where special programm es are being organized from time to time for restoring the power supply. Job complete in all respects as per directions of the Engin eer-in-Charge. NOTE: Fuse base of capacity from 16 Amp. To 300 Amp. of any voltage grade will be supplied by Owner .
Support in Measurement of earthing resistance in the station including transportation of earthing electrodes, cables etc. from store s to site, drawing the same into the ground at different points for measuring the earth resistance. The job includes the supply of c onnecting leads, clamps etc. All complete with labour and materials as per drawings, specifications and directions of the Engineer-i n-Charge. NOTE Measuring instruments to be supplied by the Owner.
Attending and rectification of complaint of the following NOTE: All materials & accessories of fittings required for attending the c omplaint shall be supplied by the owner . The Contractor has to take the material from central store/departmental store/site in-Char ge. for attending above complaints. The defective material are to be returned to the Deptt. Stores. Consumables items like PVC tape, cleaning tape, cleaning cloth, CTC etc. are in the scope of contractor. Also application of PVC/M-seal on above fittings to above e ntering of water/insects as per direction of the Engineer-in- Charge.
Tube light fittings including replacement of chokes, tubes, down rods, starters, starter holder, Tube rod and holders and all other accessories if needed including cleaning of the light fittings if required. All complete with labour and materials as per direction of the Engineer-in-Charge.
Control gear boxes of HPMV lamp fittings upto 250W including replacement of chokes, condensers, fuses, holders, fuse base, wiring or any other accessories of control gear box. All complete with labour and materials as per directions of the Engineer-in-Charge.
FLDMs/highway fittings/street light fittings including replacement of lamps, tubes, ignitors, chokes, capacitors, fuses, fuse holder s, gasket, providing/extension rod on lamp holder glass including cleaning of glass or any other accessories required. All complete with labour and materials as per directions of the Engineer-in-Charge.
Attending complaints of ceiling/ exhaust/ wall mounted/ pedestal/ air circulators/any other type of fans of various sizes/makes incl uding replacement of condensor, regulators etc. All complete with labour and materials as per directions of the Engineer-in-Charge. NOTE : Condensor and regulators will be supplied by Owner , consumables like PVC tape, cleaning cloth, CTC etc. are to be supplied b y Contractor.
Attending complaint of installation e.g. hand lamps, flood lights, exhaust fans, halogen fittings, smoking booth & other elect. Comp laints & replacement of crocodile clips on earthing leads with a maximum period of one hour from the time of receipt of complaint.
Support in Rectification of circuit fault in FLP/Non FLP junction boxes/DJBs/DBs/switchboards etc. other than in FLDMs including sup ply of minor type of materials costing less than Rs.6.00 in one complaint. All complete with labour and materials as per directions of the Engineer-in-Charge. NOTE : Materials used by contractor should not exceed Rs.6.00 per complaint. Balance material exceeding R s. 6.00 per complaint shall be supplied by Owner . Also application of PVC putty/M-Seal putty on above fittings, if required, to avo id entering of water/insects as per directions of the Engineer-in-Charge. Putty will be supplied by Owner .
Transportation of transformer oil anywhere within Station premises in drums of 200 Ls or more from Electrical Workshop/Store to site , pouring transformer oil in transformer tank and returning empty/filled drums from site as given below to Electrical Workshop/Store s etc. including supply of tractor & trailor with man power, driver and fuel etc. required for loading, unloading & transportation o f empty/filled transformer oil drums. All complete with labour and materials as per directions of the Engineer-in-Charge.
Support in Providing temporary Electrical connection for Hydroblast machines, welding machines & other electrical equipments of vari ous rating/capacity, including bringing, shifting necessary materials (except power cable beyond 5 mtrs, which will be paid seperate ly) from store to site & cleaning these Electrical equipments before connections. The connection will have to be dismantled by contr actor at the end of shutdown and return the materials back to store or any other place as directed by the Engineer-in-Charge. The co ntractor has to clear the site area after the end of the work. These services may be required to be given by the contractor at site round the clock including laying of cable up to maximum length of 5 mtrs. All complete with labour and materials as per direction of the Engineer-in-Charge. Note: All the above mentioned materials to be supplied by owner , consumables like PVC tape, CTC, cleaning cloth etc. are to be supplied by contractor.
Support in Installation of all types of (including FLP/Non FLP) temporary light/Fan fittings (TL Fixtures/ML Lamp with holder/Haloge n fitting /exhaust /pedestal /ceiling fans of different sizes/types/make, ICTPN of any rating, 1000W flood light fittings, 24V trans formers of capacity more than 500 VA or any other type of light fittings) of any sizes/ model/ make, connections etc. including dism antling of this fitting etc. and to and fro transporting it to Owner’s store or any other place. All complete with labour and materi als as per directions of the Engineer-in-Charge.
Support in Cleaning of cable trenches of depth upto 3 meter and width 1.5 meter of cable galleries, sub stations and other locations etc. The job includes lifting of RCC slabs/ Chequerred plates, removing of paper waste jute, mud, or any other unwanted materials l ying in trenches & dumping these waste materials in the nearest dust bin or as directed by the Engineer-in-Charge., keeping back RCC slabs/chequerred plates in positions. All complete with men and materials as per direction of the Engineer-in Charge.
Application of PVC putty/M-seal putty on lighting fixtures/Jn. Boxes/glands/switch boards etc. to avoid entering water/insects/any o ther type of things as per direction of the Engineer-in-Charge. NOTE: Putty will be supplied by owner .
Support in Cleaning of transformer includes surface cleaning i.e. cleaning of accumulated sticky oil and other dust, oil fins. Job i ncludes Support in opening of LT duct & HT terminal box, cleaning of duct and terminal box, tightening of nuts & bolts wherever is r equired. Job to be completed with all men, materials and equipments like tools & tackles as per direction and satisfaction of the En gineer-in-Charge. All cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the Contractor.
Support in Cleaning of HT/LT motors & its push button includes cleaning of accumulated oil/spilage oil & other particles on the surf ace of motor & connected cable & surrounding area of the motor. All cleaning material such as cotton waste, markin cloth etc. shall be supplied by the contractor. Job to be completed with all man & material as per direction & entire satisfaction of the Engineer-in - Charge.
HT Motors
LT motors less than 45 KW
LT motors 45 KW & above
Support in Disconnection of LT cables of following sizes at one end and reconnecting it at same place or another place after dressin g and cleaning the terminals all complete with labour and materials as per the direction of the the Engineer-in-Charge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Supply, installation and fixing of ms chequered plates of 5mm thickness. job includes cutting to size, supply of hinges / hooks for lifting, tag welding with support wherever required, painting including supply of paint, supply of all material and labor complete i n all respect
Supply and laying of rcc pipe with collers jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sa nd) for road crossing Pipes are to be laid after ramming and consolidating the ground with bricks, stone chips etc. to avoid any set tlement afterwards. Job includes supply of all labor and all materials required and executed as per direction of site engineer.
100 mm dia. R.C.C. pipe
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:
RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.
Supply and installation of 11/6.6 KV Discharge Rod as per relevant IS code
Supply and installation of 33 KV Discharge Rod as per relevant IS code
Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachk ing and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg
Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language as per relevant IS code.
Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language.
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, ba ckfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg /Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply, installation & fixing of prefabricated perforated Aluminium cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 60 0 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Removal of bricks from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or stacking it at t he edge of the trench and putting it back into the same trench or in a new cable trench as per drawing/ specification within a lead of 50 meteres after the work is completed including completing the work in allrespects with all labour and materials as per the dire ction of the Engineer- in-Charge.
Removal and relaying
Removal and stacking only
REMOVAL OF SAND FROM CABLE TRENCH: Removal of sand from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back into the same trench or in a new cable trench as per drawing within a lead of 50 meteres all comple te with labour and materials as per the direction of the Engineer-in-Charge.
Removing of MS chequered plate for cable ducks/ trenches and placing them after the job as per directions of EIC.
Dismantling of battery set including removing electrolyte from cell and transporting to the store (per cell).
415 V AC 3 phase / 230 V AC single phase motors - Support in Connection and testing of 415 V AC 3 phase / 230 V AC single phase moto rs (including space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control a nd power cables, earthing of the motor/actuator/ connecting the thermistor, installing the controller in LT panel, earthing the moto r frame, armour etc. as per the drawings, erection manuals, and as per directions of Site Engineer. Job complete in all respects inc luding the cost of supplying and installation of all the required FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wi re / strips, labour, tools, materials, etc., as required in all respects for all types of motors/heaters/thermistors/actuators etc.:
Capacity upto and including 1 KW
Capacity above 1 KW and upto 2.5 KW
Capacity above 2.5 KW but upto 7.5 KW
Capacity above 7.5 KW but upto 50 KW
Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall final layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to connection plat e. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractor exc luding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip basis.The windi ng wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decision of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nuts, bolts, washers and ot her hardwares as per original specifications. This further includes replacement of bearings (DE & NDE) of SKF make & greasing (IOC/H P make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Fu ll load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contractor free of cost. All complete wi th labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor. Bearing Shall be supplied by IOCL
Motors upto & including 1.5 KW
Motors above 1.5 KW but upto including 3.7KW
Motors above 3.7 KW but upto including 7.5KW
Motors above 7.5 KW but upto including 11 KW
Motors above 11 KW but upto including 18.5 KW
Motors above 18.5 KW but upto including 30 KW
Overhauling and painting of WAC, SAC, WC & Cold Storage of different make & different capacities located at various location within the Station premises, Station township and air monitoring stations, job includes removal of machines from location, dismantling, cle aning, washing, chemical cleaning of condenser & cooling coil, overhauling, lubrication of blower motor, checking, repair/rectificat ion/replacement of effective control component. Painting of all metal part and chassis cover internal painting with primer & outer p ainting with synthetic enamel paint. Cleaning of coil & condenser to be done with wire brush. Defective/damage insulation to be repl aced. All the electrical wires must be dressed properly. Defective wires to be replaced including supply of wires. Defective/damage asbestos sheet to be replaced. Asbestos sheet shall be provided by the owner. Cleaning/replacement of filter by Nylon filter. Re-ass embly of machine, shifting to location & testing of machine. Job complete in all respect including men & material and as per directi on and instruction of Site Engineer/Engineer-in- Charge.
Routine, regular and breakdown maintenance of WAC, SAC, WC and cold storage of different make & different capacities. Installed at v arious location of Station premises, Station township & air monitoring station. Job includes attending the complaints of machines as per the complaint register and instruction of site engineer. Job includes checking of machines, identification of defect, repair/re placement of defective component. Rewinding of blower motor. Replacement of Thermostat, Blower, Fan blade, electrical switches, cont rol knob, wires. Cleachning of air filter, removal of dust from cooling coil & condenser by removing the machine from location if re quired. Attending the minor/major leakage of refrigerant gas R- 22/R-12 arresting the leak and recharging the gas. Repair/replacemen t of defective bush/bearing of blower motor including lubrication of blower motor, tightening of all the electrical connection. Repa ir/Replacement (by repaired compressor) of defective compressor. Job includes dismantling of defective compressor either at site or at workshop after transportation of machine to workshop, taking necessary gate pass/permission from concerned authority, sending the defective compressor to repairer shop and bringing back the same/replaced (repaired) compressor from repair shop to site, re-fixing , gas charging, testing & commissioning and making the machine in perfect working condition. Replacement of all type of defective ca pacitor. Job also includes connection/disconnection for heater as per requirement and also replacing/the new fixing the new heater i n the machine. The heater shall be provided by the department. Job complete in all respect including all consumables including gas, men & material and as per direction and
Supply & fixing of remote control switch pendant type for temperature controlling of the Voltas/Amtrex/ Fedders Lloyds/ Carrier Airc on or any other make, split air conditioners of 2.0/3.0 (2x1.5 TR) TR capacity. Job includes dismantling of the defective switches a nd wire and installation of new switch. Job complete in all respect including man and material and as per the directions of Engineer -in-Charge.
Dismantling & shifting of Split Air Conditioning Unit 1.0TR / 1.5TR / 2.0TR capacity including indoor and outdoor unit, refrigerant tubing etc. complete to new location or A/C workshop as per direction of Engineer-in-charge.
Installation of split type wall Mounted Air Conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and fir st charge refrigerant R410A/R22/Other, including connection of copper pipe and material supplied with complete unit etc. as required (Excluding cost of copper pipe) within Station / Petrochemical Complex/ Station Township as per direction of Engineer-in-charge.
Supply & fixing of additional length of copper tube for split A/C commissioning including all accessories.
Replacement of burnt uncut compressor of 1.5-ton capacity from the manufacturer whenever required as per direction of engineer-in-ch arge.
Gas charging of air conditioner upto 1.5ton capacity with job involved transportation of machine to vendors' works. Checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charges of refrigerant gas - 22. A
Replacement of burnt uncut compressor of 1.0 ton capacity from the manufacturer whenever required as per direction of engineer-in-ch arge.
Supply & Installation of MS Stands for mounting of Outdoor Units.
Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cabl e drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantlin g of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
DISMANTLING OF ELECTRICAL WIRING Electrical wiring (comprising of single or twin core PVC wires upto 6 Sq mm and single earth wire u pto 6 SWG) along with its connected accessories like junction boxes, surface conduits, battons, switch boards etc.: Electrical wirin g (comprising of single or twin core PVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with its connected accessories l ike junction boxes, surface conduits, battons, switch boards etc.
Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays and relaying as per drawing and direction of Engineer-in charge, all complete with labour and materials. Job includes declamping, rerouting and relaying of cab le for reglanding etc.
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Disconnection, Sealing with waterproof cable end cover and coiling it neatly for placing in cable trench below, of incoming and outg oing cables from the panels and equipments:
2/3/4/5/6C upto 95 sqmm
2/3/4C from 120 upto 400 sqmm
Dressing of cable in underground trenches, cable trays/rack etc. including supply and fixing of clamps etc., wherever necessary, as per the direction of the Engineer- in-charge
Overall diameter upto 35 MM
Overall diameter > 35 MM but upto 55 MM
Overall diameter >55 MM but upto 75 MM
Overall diameter > 75 MM
Providing and fixing of 16 / 0.20 mm twin twisted, flexible, cotton braided, copper cable in polythene sleeve or conduit of suitable size on floor / wall or on side of the table /door etc. as required.
Providing and fixing of 16 / 0.20 twin core, PVC sheathed flat, flexible, copper cable on floor / wall or on side of the table / doo r etc. as required.
Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, with acrylic door cover, IP-42 /43, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for moun ting MCBs (but without MCBs and incomer ) as required as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Char ge.
4 way (4+4+12), TPN, vertical type, MCB DB, double door, IP-42
8 way (4+4+24), TPN, vertical type, MCB DB, double door, IP-42
12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-42
6 way (4+4+4+18), TPN, vertical type, MCB DB, double door, IP-43
Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, with metal double door, IP-54, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Charge.
4 way (4+4+12), TPN, vertical type, MCB DB, double door, IP-54
8 way (4+4+24), TPN, vertical type, MCB DB, double door, IP-54
12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-54
Supply and installation of blanking plates in all types of DBs as per direction of Engineer-in-charge.
Supply, fixing and manpower support in connection of following industrial type plugs / sockets (confirming to IS/IEC-309) of M/S HAV ELL/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.
PLUG- 2 POLE+ EARTH, 250V- 10 AMP
PLUG- 2 POLE+ EARTH, 250V- 20 AMP
PLUG- 3 POLE+ EARTH, 440V- 10 AMP
PLUG- 3 POLE+ EARTH, 440V- 20 AMP
SOCKET- 2 POLE+ EARTH, 250V- 10 AMP
SOCKET- 2 POLE+ EARTH, 250V- 20 AMP
SOCKET- 3 POLE+ EARTH, 440V- 10 AMP
SOCKET- 3 POLE+ EARTH, 440V- 20 AMP
Supplying and manpower support in fixing 20 amps., 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclo sed plug top alongwith 20 amps. C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Note:ISI marked sockets shall be used.
Supplying and manpower support in fixing 20 amps., TPN, industrial type socket outlet, with 4 pole and earth, metal enclosed plug to p alongwith 20 amps. C Curve, TPMCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outle t, and complete with connections, testing and commissioning etc. as required. Note: ISI marked sockets shall be used.
Supplying and manpower support in fixing 30 amps., TPN, industrial type socket outlet, with 4 pole and earth metal enclosed, plug to p, alongwith 30 amps., C curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Note: ISI marked sockets shall be used.
Supply of TPN, switch disconnector fuse unit (panel mounted type) of following rating with ISI marked HRC fuses as per direction of Engineer-in-Charge.
Supplying following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinne d copper bus bar, neutral bus bar, earth, bar, din bar, interconnections, powder painted etc. as required. (But without MCB/RCCB/ELC B/Isolator) as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Charge.
Sheet steel DP MCB enclosure
Sheet steel TP MCB enclosure
Supplying and manpower support in fixing of following rating 240 volts, 50Hz, 10KA, 'B' Curve, miniature circuit breacker (suitable for lighting and other domestic loads and conforming to IS 8828:19) of single poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp/equivalent make shall be used as per direction of Engineer-in-Charge.
5 To 32 Amp
Supplying and manpower support in fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA 'C' curve, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kop p or equivalent make shall be used as per direction of Engineer- in-Charge.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and netural
Four pole
Supplying and manpower support in fixing following rating, single pole & double pole isolator in the existing MCB DB complete with c onnections, testing and commissioning etc. as required. Note: ISI marked isolators shall be used.
40 amps. Single Pole
63 amps. Single Pole
80 amps. Double Pole
100 amps. Double Pole
125 amps. Double Pole
Supplying and manpower support in fixing following rating, three pole and four pole, 415 volts, isolator in the existing MCB DB comp lete with connections, testing and commissioning etc. as required. Note: ISI marked isolators shall be used.
40 amps. Tripple Pole
63 amps. Tripple Pole
80 amps. Tripple Pole
100 amps. Tripple Pole
125 amps. Tripple Pole
80 ams. Four Pole
125 amps. Four Pole
Supplying and manpower support in fixing following rating, double pole, (single phase neutral), 240 volts, residual current circuit breaker (RCCB/ELCB), ISI marked, having a sensitivity current indicated miliamperes in the existing MCB DB complete with connections , testing and commissioning etc. as required. Note: ISI marked RCCB/ELCB shall be used.
16 amps., 30 mA
16 amps, 100 mA
16 amps,, 300 mA
25 amps, 100 mA
25 amps,, 300 mA
32 amps., 30 mA
32 amps, 100 mA
32 amps,, 300 mA
40 amps,, 300 mA
63 amps,, 300 mA
Supplying and manpower support in fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB/ELCB), ISI marked, having a sensitivity current upto indicated milliamperes in the existing MCB DB complete with conne ctions, testing and commissioning etc. as required. Note: ISI marked RCCB/ELCB shall be used.
25 amps, 100 mA
25 amps,, 300 mA
40 amps,, 300 mA
63 amps,, 300 mA
Supply of following rating and breaking capacity 3 pole MCCB with thermomagnetic release alongwith terminal spreaders as per directi on of Engineer-in-Charge.
100 Amps, 16kA
125 Amps, 16kA
150 Amps, 16kA
Supply of following rating and breaking capacity 4 pole MCCB with thermomagnetic release along with terminal spreaders as per direct ion of Engineer-in-Charge.
100 Amps, 30kA
125 Amps, 36kA
Supply of MCB / Isolator/ RCCB/ELCB of following rating as per direction of Engineer-in-Charge.
25 amp modular SPMCB, ‘C’ curve
6 amps. to 32 amps. ratings , SP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , SPN MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , DP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , TP MCB, “C” curve,10 KA breaking capacity
6 amps. to 32 amps. ratings , TPN MCB, “C” curve,10 KA breaking capacity
40 amps. to 63 amps. ratings , 3 Pole MCB, “C” curve,10 KA breaking capacity
40 amps. to 63 amps. ratings , 4 Pole MCB, “C” curve,10 KA breaking capacity
2 Amps, 10kA breaking capacity, 'C'Curve
40 Amps, 2 Pole Isolator
63 Amps, 2 Pole Isolator
40 Amps, 4 Pole Isolator
63 Amp, 4 Pole Isolator
100 Amp, 4 Pole Isolator
25 Amp, 2 Pole RCCB/ELCB, 30mA
40 Amp, 2 Pole RCCB/ELCB, 30mA
40 Amp, 2 Pole RCCB/ELCB, 100mA
63 Amp, 2 Pole RCCB/ELCB, 30mA
63 Amp, 2 Pole RCCB/ELCB, 100mA
25 Amp, 4 Pole RCCB/ELCB, 30mA
40 Amp, 4 Pole RCCB/ELCB, 30mA
40 Amp, 4 Pole RCCB/ELCB, 100mA
63 Amp, 4 Pole RCCB/ELCB, 30mA
63 Amp, 4 Pole RCCB/ELCB, 100mA
Supply, fixing and support in connection of following 240/415V, 50HZ, with 10KA short circuit capacity Residual current circuit brea ker with overload and short circuit protection (confirming to IS 12640-2:2001 & IEC 61009-2-1) of L&T /GEC Astholm/Standard /MDS/DAT AR/ HAVLES make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of E-I- C
Double pole(four module - 25 A ( SENSITIVITY 30 mA )
Double pole(four module - 25 A ( SENSITIVITY 100 mA )
Double pole(four module - 25 A ( SENSITIVITY 300 mA )
Double pole(four module - 40 A ( SENSITIVITY 30 mA )
Double pole(four module - 40 A ( SENSITIVITY 100 mA )
Double pole(four module - 40 A ( SENSITIVITY 300 mA )
Supply, fixing and manpower support in connection of following KNIFE TYPE (DIN) / BOLTED HRC fuse link AS PER IS:13703:1993 & IEC 26 9:1986 of M/S HAVELL/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.
20-32 AMP Size 000
50 AMP Size 000
63 AMP Size 000
80 - 100 AMP Size 000
125 AMP Size 00
125 AMP Size 1
160-200 AMP Size 1
315 / 400 Amps, size 2
315/400 Amps, size 3
500 Amps, Size 3
630 Amps, Size 3
800 Amps, Size 3
2-16 Amps, L&T HG type size F1
20-32 Amps, L&T HG type size F1
20-32 Amps, L&T, HQ type, size A1L
50-63 Amps, L&T, HQ type,size A1L
4-32 Amps, L&T, HQ type, size A2
35-63 Amps, L&T, HQ type, size A3
80-100 Amps, L&T, HQ type, size A4
125-160 Amps, L&T, HQ type, size A4
80-100 Amps, L&T, HQ type, size B1
125 Amps, L&T, HQ type, size B1
125-200 amps, L&T, HQ type size B2
250-315 Amps, L&T, HQ type, size B3
355-400 Amps, L&T, HQ type, size B4
400 Amps, L&T, HQ type, size C2
500 Amps, L&T, HQ type, size C2
630 Amps, L&T, HQ type, size C2
Supply, fixing and support in connection of following equipments in panels including small mechanical works and supply of all fixing materials. All complete with labour and materials as per the direction of Engineer-in-Charge
Control contactors- 4 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MX0 of L&T or equivalent
Control contactors- 8 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MX0 of L&T or equivalent.
Control contactors- 4 contacts for DC control standard coil voltage - 24, 110, 220 Type MX0 of L&T or equivalent
Control contactors- 4 contacts for DC control standard coil voltage - 24, 110, 220 Type MN0 of L&T or equivalent.
Power Contactor (Upto 2NO + 2 NC)- 40 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML3 of L&T or equivalent
Power Contactor (Upto 2NO + 2 NC)- 70 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML4 of L&T or equivalent
Power Contactor (Upto 2NO + 2 NC)- 110 Amp (AC3) for AC standard coil voltage - 110, 230, 415 V, 50Hz Type ML6 of L&T or equivalent
Thermal Relays type L&T MN12 or equivalent, 42 - 69 A to 90 - 150 A (CT operated) with separate mounting
Thermal Relays type ML0/ML1/ML1.5 - 0.15 - 0.25 A to 10.0 - 16.0 A (Direct operated) contractor
Thermal Relays type ML2/ML3 - 9.0 - 14.0 A to 28.0 - 42.0 A (Direct operated) contractor
Mushroom actuator with holder pushbutton, Type:3SB, SIEMENS or equivalent as per direction of Engineer-in- charge.
Installation of Current Transformer of any rating
Supply of power contactor, 3 Pole, AC 3 Duty, 240 VAC, 50 Hz coil of following rating as per direction of Engineer-in-Charge:
25 Amps, L&T MNX25 or equivalent
32 Amps, L&T MNX32 or equivalent
45 Amps, L&T MNX45 or equivalent
70 Amps, L&T MNX70 or equivalent
95 Amps, L&T MNX95 or equivalent
140 Amps, L&T MNX140 or equivalent
400 Amps, L&T MNX400 or equivalent
25 Amps, L&T ML1.5 or equivalent
32 Amps, L&T ML2 or equivalent
Power contactor, 4 pole, 200A, L&T MCX 33, 2 NO+2 NC, Coil voltage:240 V AC, Cat no: CS 97021
Supply of Bimetal overload relay of following rating, make L&T MN-2 or equivalent as per direction of Engineer-in-Charge:
0.2 - 0.33 Amps to 0.6-1.0 Amps
0.9-1.5Amp to 6-10 Amps
Supply of Bimetal overload relay of following rating, make L&T MN-5 or equivalent as per direction of Engineer-in-Charge:
Supply of Bimetal overload relay, Range 6-10 Amps, for L&T make ML1.5 contactor or equivalent
Supply of Bimetal overload relay, Range 9-14 Amps, for L&T make ML 2/3 contactor or equivalent
Supply of Spare Contact Kit for contactors of following type as per direction of Engineer-in-Charge:
Power contactor L&T ML1.5 or equivalent.
Power contactor L&T ML2 or equivalent.
Power contactor L&T ML3 or equivalent.
Power contactor L&T MNX 32 or equivalent.
Power contactor L&T MNX 40 or equivalent.
Power contactor L&T MNX 70 or equivalent.
Supply of Spare coil for contactors of following type as per direction of Engineer-in-Charge:
L&T ML1.5, Cat No. SS90873 or equivalent
L&T ML2/3, Cat No. SS90545 or equivalent
L&T MNX70, Cat No. CS94192 or equivalent
Supply of Add on auxiliary contact block for contactors of following type as per direction of Engineer-in-Charge:
L&T MNX 9-80, front mounting, 2NO+2NC, Cat No. CS94114 or equivalent
L&T MX-A1 front mounting, 2NO+2NC, Cat No. CS94035 or equivalent
Supply of spreader terminals for MCCBs (make L&T or equivalent) of following rating & type.
125/250 Amps, 3 Pole
400 Amps, 3 Pole
630 Amps, 3 Pole
250 Amps, 4 Pole
400 Amps, 4 Pole
Supply and fixing of led indication lamp in the panels. leds shall be provided with leakage voltage protection upto 40v. Operating v oltage shall be 110V / 220V / 230V /AC /DC, Panel cutouts shall be 22.5 / 25.5 / 30.5 mm. Terminals shall be shrouded for finger pro ofing and safety are with captivated washers to hold two lugged (fork / pin) wires in one terminal. Job includes supply of labor and various undry materials required and finally testing of led's for + following ed's
Red / yellow / amber / green / milky white led's
Blue led
PROVIDING COPPER LUGS FOR MAINTENANCE Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equiva lent certified by EIC. of the following sizes.: Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes.
PROVIDING ALUMINIUM LUGS FOR MAINTENANC Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or e quivalent certified by EIC. of the following sizes.: Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowe lls make or equivalent certified by EIC. of the following sizes.
PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS Supply of CMRS / CCE approved flameproof double compression (brass) cab le gland for following overall cable sizes as per directions of Engineer-in-Charge.: Supply of CMRS / CCE approved flameproof double compression (brass) cable gland for following overall cable sizes as per directions of Engineer-in-Charge.
PROVIDING SINGLE COMPRESSION (BRASS) CABLE GLANDS Supply of single compression (brass) heavy duty type cable gland for following ove r all cable sizes as per directions of Engineer-in-Charge.: Supply of single compression (brass) heavy duty type cable gland for fol lowing over all cable sizes as per directions of Engineer-in-Charge.
LT STRAIGHT THROUGH CABLE JOINT FOR ARMOURED PVC INSULATED CABLE (INCLUDING COST OF JOINT KIT OF CAST RESIN TYPE WITH IS MOULD): Mak ing straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, stripping of cable insulation, including supply of cast resin straight through cable jointing kit with IS mould of Mahindra /CCI/ approved equ ivalent make with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-cha rge.
2 x upto 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x upto 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
3-1/2 x upto 6 sqmm
3-1/2 x 10 sqmm
3-1/2 x 16 sqmm
3-1/2 x 25 sqmm
3-1/2 x 35 sqmm
3-1/2 x 50 sqmm
4 x upto 6 sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
LT STRAIGHT THROUGH CABLE JOINT FOR ARMOURED PVC INSULATED CABLE (INCLUDING COST OF JOINT KIT OF HEAT SHRINKABLE TYPE): Making strai ght through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, stripping of cable insulation, including supply of heat shrinkable TUBULAR straight through cable jointing kit of Raychem / CCI / approved equivalent m ake with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer in-charge.
Upto 3 / 3.5 / 4 x 6 sqmm
3 / 3.5 / 4 x 10 sqmm
3 / 3.5 / 4 x 16 sqmm
3 / 3.5 / 4 x 25 sqmm
3 / 3.5 / 4 x 35 sqmm
3 / 3.5 / 4 x 50 sqmm
LT CABLE HEAT SHRINKABLE INDOOR / OUTDOOR CABLE END TERMINATION (INCLUDING COST OF END TERMINATION KIT): Providing end termination o f power cable including cutting, stripping, providing lugs, cable insulation, providing and glanding with single/double compression heavy duty brass cable gland conforming to IS-12943 , wherever specified, providing aluminium lugs, crimping/soldering, as necessary , restoration of insulation/ clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. Make of kits shall be of Raych em/ CCI/ approved equivalent make.
Upto 3 / 3.5 / 4 x 10 sqmm
3 / 3.5 / 4 x 16 sqmm
3 / 3.5 / 4 x 25 sqmm
3 / 3.5 / 4 x 35 sqmm
3 / 3.5 / 4 x 50 sqmm
LT OUTDOOR END TERMINATIONS FOR ARMOURED/ PVC INSULATED CABLE (INCLUDING COST OF CAST RESIN END TERMINATION AND LUGS): Providing end termination of power/control cable including cutting, stripping, fixing lugs, crimping/soldering, with cast resin end termination, restoration of insulation/clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals e tc. all complete with labour and materials as per standard and direction of the Engineer-in-charge.
2 x 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
3 - 1/2 x 10 sqmm
3 - 1/2 x16 sqmm
3 - 1/2 x 25 sqmm
3 - 1/2 x 35 sqmm
3 - 1/2 x 50 sqmm
Support in LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH SINGLE COMPRESSION BRASS GLANDING (EXCLUDING COS T OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, fixing lugs, cable insulation, & glanding with single compression heavy duty brass cable gland wherever specified, fixing aluminium lugs for power cables and copper connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminiu m tag,earthing of armour, manpower support in connection to the equipment terminals etc. all complete as per standard and direction of the Engineer-in-Charge.
2 x 6 sqmm
2 x 10 sqmm
2 x 16 sqmm
2 x 25 sqmm
2 x 35 sqmm
2 x 50 sqmm
3 x 4 Sqmm
3 x 6 Sqmm
3 x 10 sqmm
3 x 16 sqmm
3 x 25 sqmm
3 x 35 sqmm
3 x 50 sqmm
4 x 4 Sqmm
4 x 6 Sqmm
4 x 10 sqmm
4 x 16 sqmm
4 x 25 sqmm
4 x 35 sqmm
4 x 50 sqmm
3 x 2.5 sqmm LT control cables with copper lugs
5 x 2.5 sqmm LT control cables with copper lugs
7 x 2.5 sqmm LT control cables with copper lugs
10 x 2.5 sqmm LT control cables with copper lugs
12 x 2.5 sqmm LT control cables with copper lugs
14 x 2.5 sqmm LT control cables with copper lugs
16 x 2.5 sqmm LT control cables with copper lugs
19 x 2.5 sqmm LT control cables with copper lugs
3-1/2 x 25 sqmm
3-1/2 x 35 sqmm
3-1/2 x 50 sqmm
Supply of three phase digital ammeter, 0-1000A, 1/5 A,Class- 0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
Supply of Three phase digital voltmeter, Class-0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
Supply of rotary handle (extended ROM) for MCCBs (make L&T or equivalent) of following rating
Supply of Fuse Base of following types as per direction of Engineer-in-Charge:
Fuse Base L&T HD32B Cat No. ST30735 or equivalent
Fuse Base L&T HK63B cat No. ST30763 or equivalent
Fuse Base L&T HK125B cat No. ST30771 or equivalent
Supply, fixing and support in connection of following Fuse base (HOLDERS) for HRC fuse link of M/HAVELL'S/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-c harge.
20 AMP ( H-Front/B_Bus Bar Connection ) -FOR FUSE TYPE HNS
32 AMP ( H-Front/B_Bus Bar Connection) -FOR FUSE TYPE HTIA
63 AMP ( H-Front/B_Bus Bar Connection) -FOR FUSE TYPE HTSS
100 AMP ( Front Connection) -FOR FUSE TYPE HTSD
100 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
125 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
250 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-1
400 AMP ( Open Type Fuse Base) FOR FUSE TYPE CD-2
630 AMP ( Open Type Fuse Base) FOR FUSE TYPE CD-3
Supply of accessories for transformers
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 750gm silicagel as per direction of Engineer-in-Ch arge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-C harge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-C harge.
Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge.
Supervision & Logistic Charges @ 15% of the total manpower charges excluding Liveries Payment
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.54 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
GCC.pdf
Tender Documents • 1.42 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
BOQ_198543.xls
BOQ • 2.35 MB
Technical_Specifications.pdf
Tender Documents • 3.77 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
TechnicalAnnexure.pdf
Tender Documents • 0.49 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
PPLCPPENDMA1.pdf
Additional Documents • 6.18 MB
VIMCommunicationChatbotManual.pdf
Additional Documents • 1.60 MB
Annexure_Commercial.xls
Tender Documents • 0.49 MB
9232C26A02.pdf
Tender Documents • 6.33 MB
Download all tender documents and submit your bid