| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹4.2 Cr+₹85,723.50 (0.21%)Rejected-AOC | ₹4.2 Cr+₹85,723.50 (0.21%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹4.5 Cr+₹39.6 L (9.56%)Rejected-Finance | ₹4.5 Cr+₹39.6 L (9.56%) | L3 | Rejected-Finance Highest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
31 Dec 2020, 3:00 pmClosed
T.P. Baiju Senior Manager Projects
Forest Industries Travancore Limited Aluva
PROPOSED SCHOOL OF FUNDAMENTAL RESEARCH IN AYURVEDA FOR KUHS AT THRIPUNITHURA, ERNAKULAM DISTRICT (THIRD PHASE)
2020_FITL_401073_1
FIT/CP-06/2020-21
Open Tender
Electrical Works
Item Wise
365 days
Thripunithura
Refer NIT Document
2 documents required · 2 mandatory
₹8,850
₹1 L
Forest Industries Travancore Limited Aluva
7 Jul 2021
16 Dec 2020
1 Jan 2021
16 Dec 2020
31 Dec 2020
18 Dec 2020
16 Dec 2020 - 18 Dec 2020
18 Dec 2020
Amount
Civil works
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.17.1 : Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5 m
2.17.2 : Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m
od164996/2020_2021 : Providing and laying in position ready mixed M-10 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @216 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.
od181378/2020_2021 : Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.<br>All works up to plinth level
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
od181472/2020_2021 : Providing and fixing 108kg CI manhole cover with frame.
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od177599/2020_2021 : Providing and fixing of sandwich panel construction 50mm thick and standard dimension constructed from slightly corrugated pre-painted steel sheets on both sides, and fixed onto a steel frame, with injected polyurethane insulation foam, of average density 38 kg/ms, in between. The panels are joined together tongue and groove. for roofs
od177601/2020_2021 : Providing & Fixing of Aluminium Perforated metal ceiling consisting of 600x600mm Lay-in tiles of Aluminium in 0.7 mm thickness. The perforation must have Micro Perforation having hole diameter as 1.5mm and open area as 18%. The tile must be powder coated to White color having powder coat thickness ranging from 60-80 microns. Back side of the tile must have accoustimax fleece hot pressed to achieve NRC upto 0.5 and Fire Performance of Class 0/Class 1 as per BS476 Part 6 & 7 in module size of 600x600mm. The tile must be laid with 15 mm wide T - section flanges color white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.5 Kgs/M2 (as per standard installation procedure) & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system.
od174428/2020_2021 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. b) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. c) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
od174424/2020_2021 : Providing and fixing vetrified wall tiles in different size (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to 13.15622, of approved make in all columns and shades, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
od178730/2020_2021 : Providing and fixing of Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be double rebate frame profile of size 143 x 57mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drved Lab for the above grade of concrete with 28 days test results to the Engineer in charge for the approval of design mix prior to start of any type of concreting works at site. The contractor should quote his rate considering minimum 360 kg of 43 grade OPC cement plus required fly ash as per IS code. Door leaf shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with lock seam. For pair of doors astragals will be provided as required. 200x300mm Vision lite wherever applicable should be provided as per manufacturers recommendation with a beeding and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished with polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt sprey test. Rate should incluecified period of application<br>and maintain the surface dry time and sheen level as per Manufacturer specification 2Hrs Fire Rated Door FD2 Single leaf 1200x2400mm with vision panel :1200x2400mm with hardware set # Hinges 3090 F, 5 Knl, 2- 4nos of Ball bearing butt hinges size 4" x 3" x 3mm SS 304 One point panic device PHA 2001 - PHA2102, PHA 2105 L=1300mm External trim PHT 3905 prepared for euro profile cylinder. EP Half Cyl. 3010, 5pin one side key Length=42mm, SNP Door closer TS 89 EN 2-4 with Sliding arm Self adhesive seal for frames 488S, Black 6mm thick Fire Rated Vision Panel of size 300 x 450 mm 4mm Ceramic Gasket
od179952/2020_2021 : Supply and installation Sewage Treatment Plant (STP) New Generation Package Sewage Treatment Plant (NGPSTP) or advanced technology of capacity 20KLD MS FRP coated including other ancillary and related works including Design, Engineering, and preparation of civil/ structural drawings and providing all equipment / Piping etc. at site, erection testing and commissioning of equipment's/ electricals/ piping including carriage etc. for Sewage treatment plant and system requirement to meet the parameters for reusing water for gardening , car washing flushing etc. The plant comprises of the following except civil construction i.e. Bar Screen Chamber, Sludge holding tank, Equilization tank, sludge drying beds, treated water tank and grease trap. Vendor need to submit test certificate from approved lab.
14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
Sanitary Fittings
17.81 : Providing and fixing floor mounted, white vitreous china single piece, doubletraps syphonic water closet of approved brand/make, shape, size and patternincluding integrated white vitreous china cistern of capacity 10 litres with dualflushing system, including all fittings and fixtures with seat cover, cistern fittings,nuts, bolts and gasket etc including making connection with the existing P/Strap, complete in all respect as per directions of Engineer-in-Charge.
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
17.23 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
od181612/2020_2021 : Providing and fixing white vitreous china urinal partition to wall.
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
17.22A : Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.
50.17.1.2 : Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
17.32.2 : Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
od164848/2020_2021 : Supply and Fixing of CP Overhead Shower, Long light body with wall flange per the specifications and drawings etc.,complete.
od164849/2020_2021 : Supply and Fixing of CP Towel Ring as per the specifications and drawings etc., complete.
od164850/2020_2021 : Supply and fixing CP Pillar cock for wash basins as per the specifications and drawings etc., complete.
17.34.1 : Providing and fixing toilet paper holder:C.P. brass
External Facade Works
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”
od124084/2020_2021 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer high performance glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner hgh performance glass 6mm thick, spacer tube 12mm wide filled with gas, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
$Electrical Works
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.12 : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulatedcopper conductor single core cable for loop earthing as required.
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
MCCB, MCB and DB's
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
2.2.2 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp,16 KA,TPMCCB
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Earthing
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Lighting conductor
6.4 : Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For horizontal run)
6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For vertical run)
6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
MV Cable Laying
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
HT Cable Laying
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
MV Cable Jointing & End Termination
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
HV Cable Jointing and End Termination
Transformers
od131432/2020_2021 : 400 KVA CAST RESIN UNITISED SUB STATION (USS)<br>Supply,Erection, testing and commissioning of 11KV, 50c/s, 630Amps, 250MVA, Air Break SFU panel with 24 Volt D.C. tripping mechanism with remote trip facility Indoor, Floor mounting type complete with Opening, Closing, Tripping and Earthing Mechanism with 25A fuse with transformer 400KVA, 11KV/433V, 50c/s, DRY type, Vector Group DYN-11, Copper Wound indoor type with cable box at the 11KV side and L.T.side, 'OFF load tap at the 11KV side,
od131433/2020_2021 : HT METERING UNIT (OUT DOOR)<br>Supply ,Erection, testing and commissioning of 11KV Cast resin CT/PT unit consisting of 10/5A, class 0.2S, 15VA current transformers, 11KV/110V class 0.2 S, 100VA potential transformers. And Tri vector meter with TOD meter in a suitable weather proof sheet steel enclosure as per state electricity board norms including supply and fixing of Test fuses and 10.0Cx2.5 sq.mm armoured copper cable between CT/PT terminal block, control unit and TOD meter .Provision for terminating 3x185 sq mm XLPE cable.
D.G. Sets
od131440/2020_2021 : 200 KVA DG SET<br>Supply, Erection, Testing and commissioning of 200KVA, 415Volts, 3Phase, 50c/s, Diesel Engine coupled Alternator working at 0.8 p.f. comprising of Starting equipment for the Diesel Engine and including the following. Fixing of diesel tank and supply and fixing of Fuel line for the diesel engine. Supply & Fixing of residential silencer for the engine. Supply and fixing of Exhaust line 25 METER and Aluminium cladding up to top for exhaust line.
Cables
od131537/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>H.T. 11KV(E)XLPE CABLES<br>3Cx185 SQ.MM.
od131541/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx400 SQ.MM.<br>
od131542/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx300 SQ.MM.
od131543/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx240 SQ.MM.
od131544/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx150 SQ.MM
od131545/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx120 SQ.MM
od131546/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx70 SQ.MM.
od131548/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>3.5Cx35 SQ.MM.
od131549/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>4.0Cx25 SQ.MM.
od131550/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>4.0Cx16 SQ.MM.
od131551/2020_2021 : Supply of the following PVC Insulated Armoured Aluminium HT cable XLPE/ L.T.Cables (XLPE/AYWY/AYFY) Cables through excavated trenches, built up cable trenches, cable trays, hume pipes,including supply and fixing of clamps, nuts and bolts, screws, 'identification tags, route markers etc. required for clamping intervals as necessry.<br>L.T. ALUMINIUM CABLES<br>4.0Cx10 SQ.MM.
Control Cables
od131594/2020_2021 : Supply & Laying, testing and commissioning of the following 1.1KV Grade PVC Insulated Armoured Copper Control Cables (YWY/YFY) through excavated trenches, built up cable trenches, cable trays, hume pipes as necessary and including supply of all materials for clamping, cable route markers, identification tags and clamping at intervals.<br>2C X 2.5 SQ.MM YWY.
od131596/2020_2021 : Supply & Laying, testing and commissioning of the following 1.1KV Grade PVC Insulated Armoured Copper Control Cables (YWY/YFY) through excavated trenches, built up cable trenches, cable trays, hume pipes as necessary and including supply of all materials for clamping, cable route markers, identification tags and clamping at intervals.<br>3C X 2.5 SQ.MM YWY.
Termination
od131599/2020_2021 : Supply of all materials and termination of the following 1.1 KV Grade PVC Insulated Armoured Copper Control Cables (AYWY / AYFY)<br>using single compression type cadmium plated brass cable glands, Copper crimped type cable lugs, cable identification tags and including gland and armour earthing using copper conductor of adequate size etc.<br>2C X 2.5 SQ.MM YWY.
od131600/2020_2021 : Supply of all materials and termination of the following 1.1 KV Grade PVC Insulated Armoured Copper Control Cables (AYWY / AYFY)<br>using single compression type cadmium plated brass cable glands, Copper crimped type cable lugs, cable identification tags and including gland and armour earthing using copper conductor of adequate size etc.<br>3C X 2.5 SQ.MM YWY.
Switch boards
od131832/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>MSB <br>Fabricated out of 14SWG CRCA sheet. Top cable entry for incoming and outgoing feeders <br>1) Busbars: 630A 4P AL BUSBAR Earth bus - 25 x 6mm CU.<br>2) Incomer1: 630A 4P, Microprocessor type 35 KA Ics MCCB with O/C,S/C, and E/F release set at 530A -1no Power contactor,AC3 duty 4P 600A -1 no<br>Relays: Stand by Earth fault relay type 51G -1no<br>Meters & Indications: 1no. Multi function meter EM6400 or equ. With RS 485 Port and 3nos metering CTs Class 1.0, 15VA, 600/5A,3 nos 2A Cut out fuses-1 set Red, Yellow and Blue Indication Lamps 3nos, 2A Control fuses - 1set.<br>1no metering CTs Class 1.0 15VA, 600/5A, for capacitor bank - 1Nos.<br>3) Incomer 2<br>400A 4P ISOLATOR- 1Nos Power contactor,AC3 duty 4P 400A -1 no<br>Meters & Indications: 1no. Multi function meter EM6400 or equ.With RS 485 Port and 3nos metering CTs Class 1.0,15VA,<br>300/5A,3 nos 2A Cut out fuses-1set Red, Yellow and Blue Indication Lamps 3nos, 2A Control fuses - 1set.<br>4) Incomer 3 400A 4P ISOLATOR- 1 Nos Power contactor,AC3 duty 4P 400A -1 no<br>Meters & Indications: 1no. Multi function meter EM6400 or equ.With RS 485 Port and 3nos metering CTs Class 1.0,15VA,<br>200/5A,3 nos 2A Cut out fuses-1set Red, Yellow and Blue Indication Lamps 3nos, 2A Control fuses - 1set. <br>5) Bus coupler: 630A 4P ISOLATOR , 1no 630A 4P AC 3 duty power contactor with auxillary contacts-1sets<br>6) AMF: PLC based Automatic Mains Fail Control shall be integrated with the Main panel, Following are the items required for the same, PLC, binary extension input unit, binary extension out put unit, Modbus RTU or equivalant.<br>7) Outgoings: 250A TPN MCCB 35A Ics Thermal Adj set at 250A, 250/5A, 10VA, class 1.0 CT, 2A control fuses and 1no. multifunction meter (VAFPF KWH) -1 nos 250A TPN MCCB 35KA Ics Thermal Adj set at 200A, 200/5A, 10VA, class 1.0 CT, 2A control fuses and 1no. multifunction meter (VAFPF KWH) -3 nos 160A TPN MCCB 35KA Ics Thermal Adj set at 150A, 150/5A, 10VA, class 1.0 CT, 2A control fuses and 1no. multifunction meter (VAFPF KWH) -4 nos 150A TPN MCCB 35KA Ics Thermal Adj set at 125A, 125/5A, 10VA, class 1.0 CT, 2A control fuses and 1no. multifunction meter (VAFPF KWH) -1 nos 200A TPN isolator with a switch links-1 set
od131841/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB - 1 & SB-2<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 250A 4P AL BUSBAR<br>Earth bus - 25 x 6mm CU.<br>2) Incomers: 250A 4P ISOLATOR- 1Nos<br>1no. Multifunction meter (A/V/F/PF) and 3 nos metering CTs class 1.0 15VA, 200/5A, 3 nos 2A cut out fuses - 1 set<br>4) Outgoings: 125A TPN MCCB 25kA Ics thermal Adj. Type set at 100A -5nos
od131843/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB -AC1<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 150A 4P AL BUSBAR<br>Earth bus - 25 x 6mm CU.<br>2) Incomers: 200A 4P ISOLATOR- 1Nos<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 150/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 63A TPN MCCB 25kA Ics thermal Adj. Type set at 50A -3nos 50A TPN MCCB 25KA Ics Thermal Adj .Type set at 40A-2nos
od131847/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB -AC2<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 150A 4P AL BUSBAR<br>Earth bus - 25 x 6mm CU.<br>2) Incomers: 200A 4P ISOLATOR- 1Nos<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 150/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 63A TPN MCCB 25kA Ics thermal Adj. Type set at 50A -4nos
od131852/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB -AC3<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 125A 4P AL BUSBAR<br>Earth bus - 25 x 6mm CU.<br>2) Incomers:<br>200A 4P ISOLATOR- 1Nos<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 125/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 63A TPN MCCB 25kA Ics thermal Adj. Type set at 50A -3nos
od131866/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB - G.F,SB-1F&SB-7F<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 100A 4P AL BUSBAR Earth bus - 25 x 6mm CU.<br>2) Incomers: 125A 4P ISOLATOR- 1Nos<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 100/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 63A TPN MCCB 25kA Ics thermal Adj. Type set at 50A -3nos 40A TPN MCCB 25KA Ics Thermal Adj .Type set at 32A-3nos
od131899/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>SB - 2F,3F,4F,5F&6F Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet<br>1) Busbars: 100A 4P AL BUSBAR Earth bus - 25 x 6mm CU.<br>2) Incomers:125A 4P ISOLATOR- 1Nos<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 100/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 63A TPN MCCB 25kA Ics thermal Adj. Type set at 50A -3nos 40A TPN MCCB 25KA Ics Thermal Adj .Type set at 32A-4nos
od131910/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>UTSB<br>Top cable entry for incoming and outgoing feeders. Fabricated out of 16SWG CRCA sheet<br>1) Busbars: 150A 4P AL BUSBAR Earth bus - 25 x3mm CU.<br>2) Incomers: 160A 4P ISOLATOR-1No<br>3) Meters & Indications: 1no. Multy Function meter (A,V,F,PF) and 3nos metering CTs Class 1.0 15VA, 125/5A,3 nos 2A Cut out fuses - 1set.<br>4) Outgoings: 80A TPN MCCB 25KA Ics Thermal Adj set at 63A - 2Nos.<br>50A TPN MCCB 25KA Ics Thermal Adj set at 40A - 1Nos.<br>40A TPN MCCB 25KA Ics Thermal Adj set at 32A - 5Nos.<br>
od131937/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>UPS PANEL <br>Top cable entry for incoming and outgoing feeders. Fabricated out of 16SWG CRCA sheet<br>1) Busbars: 63A 4P AL BUSBAR Earth bus - 25 x3mm CU.<br>2) Incomers: 100 4P ISOLATOR-1No<br>3) Meters & Indications: Red, Yellow and Blue Indication Lamps 3nos, 2A Control fuses - 1set<br>4) Outgoings: 32A TPN MCB - 8 Nos.
od132119/2020_2021 : Supply of following Cubicle type, fully compartmentalised LT Switchboards dust tight and vermin proof, fabricated out of 16 SWG<br>CRCA sheet, chemically treated and powder coat the panels with approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate. (All indication lamps should be LED type, ALL MCCBs should be with rotary handle)<br>APFC PANEL<br>Supply, Design, Erection , Testing and Commissioning of following. Top/Bottom cable entry for incoming & outgoing feeders. Fabricated out of 16SWG CRCA sheet.<br>1) Busbars: 250A 4P AL BUSBAR Earth bus - 25 x 6mm CU. Microprocessor based Automatic power factor control relay with 8 steps having inbuilt facility for PF adjustm- ent switching time adjustment etc. working on 415V AC, 5A CT secondary current-1no<br>2) Incomer: 250A 4P isolator -1no.<br>3) Meters & Indications: Red, Yellow and Blue Indication Lamps 3nos, 2A Control <br>4) Outgoings: 125A TPN SFU with 120A fuse links with 50 KVAR 3P capacitor duty contactor, 50KVAR, 480V APP Heavy duty capacitor and 7% Copper block reactor coil-1sets 125A TPN SFU with 63A fuse links with 25 KVAR 3P capacitor duty contactor, 25KVAR, 480V APP Heavy duty capacitor and 7% Copper block reactor coil-2sets <br>63A TPN SFU with 25A fuse link with 10 KVAR 3P capacitor duty contactor, 10KVAR, 480V APP Heavy duty capacitor and 7% Copper block reactor coil-2sets<br>63A TPN SFU with 25A fuse link with 5 KVAR 3P capacitor duty contactor, 5KVAR, 480V APP Heavy duty capacitor and 7% Copper block reactor coil-1sets<br>63A TPN SFU with 25A fuse links, 5KVAR, 480V APP Heavy duty capacitor and 7% Copper block reactor coil-1set
Motor Starter Panels
od132146/2020_2021 : Supply, Erection , testing and commissioning of the following 5HP DOL type motor starter, wall mounting type dust tight and verminproof, fabricated out of 16 SWG CRCA sheet, treated and painted with 2 coats of primer and two coats of paint and shall include the following.<br>Incomer: 40A TPN MCB Isolator. 1 KVAR Mixed dielectric type capacitor-1no ON/OFF Pushbuttons <br>Contactors, Overload Relays, Timers, Auxillary relays, Power terminals, Control Terminals Power and Control Wiring etc.
od132148/2020_2021 : Supply, Erection , testing and commissioning of the following 2HP DOL type motor starter, wall mounting type dust tight and verminproof, fabricated out of 16 SWG CRCA sheet, treated and painted with 2 coats of primer and two coats of paint and shall include the following.<br>Incomer: 32A TPN MCB Isolator. 1 KVAR Mixed dielectric type capacitor-1no ON/OFF Pushbuttons Contactors, Overload Relays, Timers, Auxillary relays, Power terminals, Control Terminals Power and Control Wiring etc.
Miscellaneous Items
od132163/2020_2021 : Supply and installation of Laminated copies of Approved/ as built schemesand drawings in electrical room <br>
od132164/2020_2021 : Supply & Installation of wheather poof (IP 65) out door cable box with suiificient Knockout for cable entry (167x125x82) <br>
od132165/2020_2021 : Supply & Installation Battery charger<br>
od132166/2020_2021 : Supply & laying of 50MM dia. class-B pipe embeded in concrete/ earth below ground level for drawing incoming TEL. cable.<br>
od132167/2020_2021 : Supply and installation of shock treatment chart<br>
od132168/2020_2021 : Supply and Installation of Cable route marker for HT UG Cable at every 10metre interval made of Cast Iron <br>
od132169/2020_2021 : Supply and installation of emergency OFF trip push button with front Glass and painted in RED Colour.<br>
od132170/2020_2021 : Fabrication, supply and installation of 6mm thick chequered plate and filling for fire proof partitions between floors in electrical ducts.<br>
od132171/2020_2021 : Fabrication , Supply and Installation of cable Trench covers using 6mm thick MS chequered plates for covering Trenches in Switchboard room / substation areas.
od132187/2020_2021 : Supply and installation of L.T./H.T danger sign boards.
od132172/2020_2021 : Supply and installation of 2 nos fire buckets along with stand painted with enamel paint of red colour.<br>
od132173/2020_2021 : Supply of Electrical Grade rubber hand gloves suitable for operation of 11KV Switchgear.<br>
od132174/2020_2021 : Supply of Electrical ISI Grade Rubber Mat suitable for 11000Volts Switchboards. (6' x 3' x 1/2").
od132175/2020_2021 : Supply of Electrical ISI Grade Rubber Mat suitable for 440Volts Switchboards. (6' x 3' x 1/4").<br>
od132176/2020_2021 : Supply & Installation of 5KG Dry Chemical Powder type (DCP) fire extinguishers having ISI mark along with mounting supports.<br>
Documents and Approval
od132185/2020_2021 : Preparation of necessary documents, forms, drawings, schemes, certificates,etc. and getting approval from ElectricaI Inspectorate for the installation. Submitting certiicates and arranging inspection, getting sanction and eregisation certificate from Electrical Inspectorate and KSEB, obtaining power allocation and power connection etc. for commissioning of the whole installation in the premises. All expenses except statutory charges shall be paid by the contractor.<br>
Cable Trays
od133809/2020_2021 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>150 mm width X 50 mm depth X 1.6 mm thickness
od133810/2020_2021 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>300 mm width X 50 mm depth X 1.6 mm thickness
External Works
4.7.3.B : Water Bound Macadam Sub-base/base<br> 3) WBM Grading 3<br> Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. <br>(B) By Mechanical Means
AAYKAYCONSTRUCTIONS
tharalal
Bidder Name
AAYKAYCONSTRUCTIONS
tharalal
SABANI ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .