Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAdmitted-Finance 77 17 SWARN PARK MUNDKA INDUSTRIAL AREA NEW DELHI DELHI 110041 | WEST DELHI | DELHI | 110041 | L1 | Admitted-Finance | |
| 2 | L2₹71.8 L+₹25.4 L (54.7%)Admitted-Finance 46 489J J1 OPP KENT ILLAM THAIKKAVU JUNCTION VENNALA ERNAKULAM KERALA 682028 | ERNAKULAM | KERALA | 682028 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical not prequalified | |
| 4 | Rejected-Technical | - | Rejected-Technical PQC not qualified | |
| 5 | Rejected-Technical A 62 SECTOR 58 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | Rejected-Technical not acceptable |
| Sl No | Description | Qty | Unit | VOLLWERT ELECTRIC PRIVATE LIMITED L2 | Devidayal and Mahindra Cable Industries L1 |
|---|---|---|---|---|---|
| 1.00 | 1. General
Item: 12 Triad RTD Cable ( 1.0 Sqmm ) with Individual and Overall Screen
and Armour
Testing and Dimension Standards:
BS-5308, IS-8130, IS-1554
Voltage Class: 300/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Triads
Number of Triads: 12 Nos
Triad arrangement : Twisted ( Uniformly )
Number of Twists per Meter: 10 Nos.
Triad Number: Required ( at interval of not more than 250mm)
5. Individual and Overall Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire (Individual pairs <(>&<)> Overall shield)
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2 / Core 3 : Red / Yellow / Blue
Sheath Outer / Inner: Green / Black
Communication pair : Red and Green
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 500 | Meter | 3,89,000 ₹4,59,020 | 2,56,850 ₹3,18,237.15 Lowest |
| 2.00 | 1. General
Item: 1 Triad RTD Cable ( 1.0 Sqmm ) with Screen and Armour
Testing and Dimension Standards:
BS-5308, IS-8130, IS-1554
Voltage Class: 300V/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Triads
Number of Triads: 1 No
Triad arrangement : Twisted ( Uniformly )
Number of Twists per Meter: 10 Nos.
5. Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
12. Colour Code
Core 1/ Core 2 / Core 3 : Red / Yellow / Blue
Sheath Outer / Inner: Green / Black
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 500 | Meter | 50,500 ₹59,590 | 32,350 ₹40,081.65 Lowest |
| 3.00 | CABLE, INSTRUMENT POWER
PVC Sheathed, PVC Insulated, Armoured
Standard : IS 1554 / IS 694
Voltage : 650 V
Conductor : Copper
Type : Stranded
No. of strands : 7
Armour Material : Galvanised Steel
1. General
Item: 1 Pair Power Cable (1.5 Sqmm) with Armour
Testing and Dimension Standards:
IS-8130, IS-1554
Voltage Class: 1.1KV
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Pair
Number of Pairs: 1 Nos
Pair arrangement : Twisted
Number of Twists per Meter: 10 Nos.
5. Shield / Screen: N/A
6. Drain Wire: N/A
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
12. Colour Code
Core 1/ Core 2: Red / Black
Sheath Outer / Inner: Black / Black
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 1,000 | Meter | 1,01,000 ₹1,19,180 | 62,700 ₹77,685.3 Lowest |
| 4.00 | 1. General
Item: 20 Pair Signal Cable (1.0 Sqmm) with Individual and Overall Screen
and Armour
Testing and Dimension Standards:
IS-8130, IS-1554, BS-5308
Voltage Class: 300V/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Pair
Number of Pairs: 20 Nos
Pair arrangement : Twisted
Number of Twists per Meter: 10 Nos.
Pair Number: Required (at interval of not more than 250mm)
5. Individual and Overall Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire (Individual pairs and Overall shield)
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2: White / Black
Sheath Outer / Inner: Blue / Black
Communication pair : Red and Green
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 4,000 | Meter | 37,56,000 ₹44,32,080 | 23,16,000 ₹28,69,524 Lowest |
| 5.00 | 1. General
Item: 12 Pair Power Cable (1.5 Sqmm) with Armour
Testing and Dimension Standards:
IS-8130, IS-1554
Voltage Class: 1.1KV
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Pair
Number of Pairs: 12 Nos
Pair arrangement : Twisted
Number of Twists per Meter: 10 Nos.
Pair Number: Required (at interval of not more than 250mm)
5. Shield / Screen : N/A
6. Drain Wire: N/A
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2: Red / Black
Sheath Outer / Inner: Black / Black
Communication pair : Red and Green
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 1,500 | Meter | 10,92,000 ₹12,88,560 | 6,55,500 ₹8,12,164.5 Lowest |
| 6.00 | 1. General
Item: 1 Pair Signal Cable (1.0 Sqmm) with Screen and Armour
Testing and Dimension Standards:
IS-8130, IS-1554, BS-5308
Voltage Class: 300V/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Pair
Number of Pairs: 1 Nos
Pair arrangement : Twisted
Number of Twists per Meter: 10 Nos.
5. Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2: White / Black
Sheath Outer / Inner: Blue / Black
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 4,500 | Meter | 3,91,500 ₹4,61,970 | 2,41,650 ₹2,99,404.35 Lowest |
| 7.00 | 1. General
Item: 2 Pair Signal Cable (1.0 Sqmm) with Screen and Armour
Testing and Dimension Standards:
IS-8130, IS-1554, BS-5308
Voltage Class: 300V/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Pair
Number of Pairs: 2 Nos
Pair arrangement : Twisted
Number of Twists per Meter: 10 Nos.
5. Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2: White / Black
Sheath Outer / Inner: Blue / Black
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 1,000 | Meter | 1,70,000 ₹2,00,600 | 1,03,400 ₹1,28,112.6 Lowest |
| 8.00 | 1. General
Item: 3 core Signal Cable (1.0 Sqmm) with Screen and Armour
Testing and Dimension Standards:
IS-8130, IS-1554, BS-5308
Voltage Class: 300V/500V
2. Conductor
Material: Annealed Tinned Copper
Number of Strands: 7 Nos
3. Insulation
Type: Poly Vinyl Chloride, Extruded, Type C
4. Core
Number of Cores: 3 Nos
Arrangement : Twisted
Number of Twists per Meter: 10 Nos.
5. Shield / Screen
Material: Aluminium backed Mylar/Polyester tape
Overlap / Coverage: 25% / 100%
6. Drain Wire
Material: Annealed Tinned Copper
Type: Stranded
Size: 0.5 Sqmm
7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard)
Wrapping Style : Helical
8. Filler (if reqd. as per Manufacturer's standard)
9. Inner Sheath
Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke
Rip Chord: Required, Non Metallic type, below inner sheath
10. Armour, Galvanised Steel Round Wire: Required
11. Outer Sheath
Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low
Smoke
Communication wire: Required
12. Colour Code
Core 1/ Core 2/ Core 3: White / Black / Red
Sheath Outer / Inner: Blue / Black
13. Drum
Drum length : 1000 Mtr
Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on
total ordered quantity)
Marking on cable: Length of cable to be marked at interval of not more
than five meters on external surface of the cable. | 1,200 | Meter | 1,35,600 ₹1,60,008 | 77,640 ₹96,195.96 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
21 Jul 2022, 2:00 pmClosed
SANTHOSH
PD ADMINISTRATIVE OFFICE PURCHASE DEPT PH 0484 2568347
CABLES
2022_FACT_698034_1
MM/124/E25567
Open Tender
Electrical Goods/Equipment
Supply
COCHIN DIVISION
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1 L
Yes
2 Dec 2022
5 Jul 2022
22 Jul 2022
5 Jul 2022
21 Jul 2022
5 Jul 2022
1. General Item: 12 Triad RTD Cable ( 1.0 Sqmm ) with Individual and Overall Screen and Armour Testing and Dimension Standards: BS-5308, IS-8130, IS-1554 Voltage Class: 300/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Triads Number of Triads: 12 Nos Triad arrangement : Twisted ( Uniformly ) Number of Twists per Meter: 10 Nos. Triad Number: Required ( at interval of not more than 250mm) 5. Individual and Overall Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire (Individual pairs <(>&<)> Overall shield) Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2 / Core 3 : Red / Yellow / Blue Sheath Outer / Inner: Green / Black Communication pair : Red and Green 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 1 Triad RTD Cable ( 1.0 Sqmm ) with Screen and Armour Testing and Dimension Standards: BS-5308, IS-8130, IS-1554 Voltage Class: 300V/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Triads Number of Triads: 1 No Triad arrangement : Twisted ( Uniformly ) Number of Twists per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke 12. Colour Code Core 1/ Core 2 / Core 3 : Red / Yellow / Blue Sheath Outer / Inner: Green / Black 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
CABLE, INSTRUMENT POWER PVC Sheathed, PVC Insulated, Armoured Standard : IS 1554 / IS 694 Voltage : 650 V Conductor : Copper Type : Stranded No. of strands : 7 Armour Material : Galvanised Steel 1. General Item: 1 Pair Power Cable (1.5 Sqmm) with Armour Testing and Dimension Standards: IS-8130, IS-1554 Voltage Class: 1.1KV 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number of Pairs: 1 Nos Pair arrangement : Twisted Number of Twists per Meter: 10 Nos. 5. Shield / Screen: N/A 6. Drain Wire: N/A 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke 12. Colour Code Core 1/ Core 2: Red / Black Sheath Outer / Inner: Black / Black 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 20 Pair Signal Cable (1.0 Sqmm) with Individual and Overall Screen and Armour Testing and Dimension Standards: IS-8130, IS-1554, BS-5308 Voltage Class: 300V/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number of Pairs: 20 Nos Pair arrangement : Twisted Number of Twists per Meter: 10 Nos. Pair Number: Required (at interval of not more than 250mm) 5. Individual and Overall Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire (Individual pairs and Overall shield) Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2: White / Black Sheath Outer / Inner: Blue / Black Communication pair : Red and Green 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 12 Pair Power Cable (1.5 Sqmm) with Armour Testing and Dimension Standards: IS-8130, IS-1554 Voltage Class: 1.1KV 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number of Pairs: 12 Nos Pair arrangement : Twisted Number of Twists per Meter: 10 Nos. Pair Number: Required (at interval of not more than 250mm) 5. Shield / Screen : N/A 6. Drain Wire: N/A 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2: Red / Black Sheath Outer / Inner: Black / Black Communication pair : Red and Green 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 1 Pair Signal Cable (1.0 Sqmm) with Screen and Armour Testing and Dimension Standards: IS-8130, IS-1554, BS-5308 Voltage Class: 300V/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number of Pairs: 1 Nos Pair arrangement : Twisted Number of Twists per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2: White / Black Sheath Outer / Inner: Blue / Black 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 2 Pair Signal Cable (1.0 Sqmm) with Screen and Armour Testing and Dimension Standards: IS-8130, IS-1554, BS-5308 Voltage Class: 300V/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number of Pairs: 2 Nos Pair arrangement : Twisted Number of Twists per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2: White / Black Sheath Outer / Inner: Blue / Black 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
1. General Item: 3 core Signal Cable (1.0 Sqmm) with Screen and Armour Testing and Dimension Standards: IS-8130, IS-1554, BS-5308 Voltage Class: 300V/500V 2. Conductor Material: Annealed Tinned Copper Number of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Core Number of Cores: 3 Nos Arrangement : Twisted Number of Twists per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium backed Mylar/Polyester tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder (if reqd. as per Manufacturer's standard) Wrapping Style : Helical 8. Filler (if reqd. as per Manufacturer's standard) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type ST 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic type, below inner sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type ST 2, Fire Retardant Low Smoke Communication wire: Required 12. Colour Code Core 1/ Core 2/ Core 3: White / Black / Red Sheath Outer / Inner: Blue / Black 13. Drum Drum length : 1000 Mtr Drum Length Tolerance : +/- 5% (Negative tolerance is not acceptable on total ordered quantity) Marking on cable: Length of cable to be marked at interval of not more than five meters on external surface of the cable.
VOLLWERT ELECTRIC PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .