Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1Rejected-Finance | ₹1 | 1 | Rejected-Finance a |
| 2 | 2₹2+₹1 (100.0%)Rejected-Finance | ₹2+₹1 (100.0%) | 2 | Rejected-Finance a |
| 3 | 3₹3+₹2 (200.0%)Rejected-Finance | ₹3+₹2 (200.0%) | 3 | Rejected-Finance a |
| 4 | 4₹4+₹3 (300.0%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | ₹4+₹3 (300.0%) | 4 | Rejected-Finance a |
Tender Value
₹2.0 Cr
EMD Value
₹2.8 L
Closing Date
28 Mar 2018, 6:00 pmClosed
Commander Works Engineer (Army) Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
SPECIAL REPAIRS TO 64 PBOR QUARTERS IN EAST AREA OF DEHU ROAD
2018_MES_184265_1
83740/DR/E8
Open Tender
Civil Works
Item Rate
300 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE DEHU ROAD
₹2.8 L
4 Jun 2020
17 Mar 2018
31 Mar 2018
17 Mar 2018
28 Mar 2018
23 Mar 2018
17 Mar 2018 - 28 Mar 2018
Amount
CIVIL WORKS Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for glazed, colour ceramic wall tiles (group B III), 300 mm X 200 mm X 7 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 300 mm X 300 mm X 7 mm thick laid in floors over and including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed epoxy mortar to match complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 450 mm X 450 mm X 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed epoxy mortar to match complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 450 mm X 450 mm X 8 mm thick in vertical surfaces including 15 mm thick screed bed or bedding in cement mortar(1:4) set and jointed in neat cement slurry and pointed epoxy mortar to match complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.
M & L for machine cut cuddapa stone slabs 20-25 mm thick as in kitchen platforms, risers of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M & L for bull nosed chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 32cm X 19.5cm X 30mm mm thick, with grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry as in treads including laying over 15 mm thick bedding of cement mortar(1:6) all as specified and as directed.
M & L for bull nosed chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 32cmX19.5cmX30mm mm thick, with grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in skirting, risers, dado including laying over 15 mm thick bedding of cement mortar(1:6) all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water completeDemolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete including removing the rubbish materials obtained from taking down outside MD land all as specified and directed by Engineer in charge.
Material and labour for plastering 20 mm thick (in two coats of 15 mm and 5 mm thick) on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 20 mm thick (in two coats of 15 mm and 5 mm thick) on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be measured and paid for separately.
Supply only integral water proofing compound.
M & L for preparation of newly plastered surface or unplastered surface of wall and applying two coats of oil bound distemper over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed
M & L for preparation of old plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed.
Preparation of old decorated surfaces on walls and applying one coat of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete including removing the rubbish materials obtained from demolition outside MD land all as specified and directed by Engineer in charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed.
Dismantling of wrought or mild steel work of any description not otherwise described
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Fixing only to walls and ceiling 15 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Fixing only to walls and ceiling 20 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S & F in repairs 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
Demolition of old brick bat coba from sunken floors and applying one coat of cement plaster in CM 1:3, 10 mm thick with WPC and one coat of bitumin (85/25) over one coat of bitumen primer and filled with lime mortar 1:2 mixed and 40mm grade brick course in sunken floors.
Disconnecting existing water tanks capacity exceeding 250 litres but not exceeding 500 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S & F wardrobe hooks single 50mm to 60mm of Cast iron/Mild steel
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 75 mm, complete all as specified and directed by Engineer in charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of internal dia 100 mm, set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of internal dia 75 mm, set in cement mortar complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge .
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
M & L for glazed stoneware square mouth gully trap, P type, size 150 X 150 complete all as specified and as directed.
S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F UPVC Tee(87.5 degree) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F UPVC vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC branch piece, Wye (45 degree) double, 75 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Cutting holes in brick walls in lime mortar and stone walls built in mud mortar for inserting holdfasts or lugs upto depth not exceeding half brick measured from the face of the jamb into the wall and making good dismantled portion in cement mortar 1:3 or cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile B, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
M & L for plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates in door frame filling complete all as specified and as directed.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M & L for 30 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
S & F prelaminated particle board (decorative lamination on one side and other side balancing lamination), 20 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drg complete all as specified and directed by Engineer in charge.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45 degree angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
S & F 100 mm heavy weight( Type 1) mild butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F in repairs 100 mm heavy weight( Type 1) mild butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M & L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M & L for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Preparation of previously primed steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
Dismantling of Mangalore pattern roofing tiles with ceiling tiles or slate roofing
Dismantling of single layer Mangalore pattern or similar tiles bedded in lime or cement mortar in roofing
Dismantling of battens for tiles, shingles etc., spacing exceeding 15 cm, of any size including tilting fillets
Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position
Dismantling timber scantlings in unframed works , under 40 sqcm in section, in any position
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as framed works including distant pieces, cleats for water tank base inculding cutting/welding required etc all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated profile steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick of a colour having yield strength of 550 Mpa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick of a colour having yield strength of 550 Mpa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge.
Material and labour for mineral fibre acoustic ceiling tiles for false ceiling with (micro look) edge tiles having humidity resistance of 99%, Noise Reduction Coefficient (NRC) of 0.7, light reflectance greater than 85%, Thermal Conductivity k = 0.052- 0.057 w/m K, colour white, fire Performance Class 0/ Class 1 (BS476 Part 6&7), weight 4.5 kgs/sqm in module size of 600 X 600 X 19 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 63% complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, etc. all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
S & F 25 mm dia decorative powder coated aluminium curtain rods complete all as specified and as directed.
S & F suitable brackets for 25 mm dia decorative powder coated aluminium curtain rods complete all as specified and as directed.
Taking down door/window shutters with frames (without taking off shutter from frame) for area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down door/window shutters with frames (without taking off shutter from frame) for area not exceeding 1.50 sqm each complete all as specified and as directed
EXTERNAL ELECTRIFICATION Supply and erection of three piece metal oxide lightning arrestor suitable for 11 KV continuous operating voltage (3 phase) with rated voltage 12 KV (rms) with nominal discharge current rating of 20 KA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed.
Supply and fix in replacement of drop out fuses 11 KV, 100 Amps capacity including nut bolts washers with barrel fuse expulsion type set of three including mounting on channel complete all as directed. Make :- Universal
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, Rated peak withstand current 63 kA for climatic conditions at Dehu Road, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
Supply, install, test and comissioning of Transformer step down HT 11KVA/433 Volt floor mounted outdoor type copper wound with neccesary standard fittings of capacity 250KVA, 3 phase 4 wire, 50 cycles vector ground DYN-11 having primary voltage 11KV and secondary voltage 433 Volts with tapping on primary side having steps of +/- 2.5% +/- 5% +/- 7.5% in equal steps each, so as to vary voltage on secondary side, first fill of transformer oil. The transformer shall be delta connected on 11 KV side and star connected on 433 Volts side with neutral including provision of HT bushing, on HV (Delta connection) side and LT Cable end box on LV( Star connection) side all as specified and directed including proviosn of neccesary and standard fitting and mainly comprising of the following:- (a) One cable box with suitable glands fro cable entry alongwith aluminimum lugs for 3.5x240sqmm cable. (b) Oil conservator with filter type drain valve and oil level gauge. (c ) Dehydrating breather with first fill of dehydrating agent. (d) Explosive vents. (e ) Thermometer pocket on tank cover. (f) One no 100mm dia dial type thermometer vapour pressure type having range 0-120 degrees centigrade with temp reading pointer, max temp indicator and resetting device. (g) Rating plate with terminal markings. (h) Oil level guages. (j) Earthing terminsla on tank/ tank cover. (k) Oil drain and filter valves. (l) Lifting lugs.(m) Air release valve. (n) Four plain detachable rollers. (o) First fill of fresh oil conforming to relevant IS and tested upto 40 KV di-electric strength. (p) Any other fittings/ accessories so as to conform the whole transformer to IS- 2026 . Note - Steel sections for mounting platform shall be measured and paid seperately.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coat or synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
S & F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and as directed.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core 50 sqm complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 240 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supplying & laying in trenches 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Material and labour for provision of plinth for transformer 250 KVA of size 2.00mx2.00mx1.50m as per drg no CEPZ/98/TD/06 sheet 2/2 complete including excavation and earth work, PCC, making good disturbed surfaces etc as directed by Engineer-In - Charge
Supply and fixing 32 mm X 6 mm galvanised mild steel strip for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
INTERNAL ELECTRIFICATION Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one bell/buzzer point controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F modular switch, 2 way, 6 A, 1 module complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, cord grip, non-switched, unenclosed, without T marking, B22d with M13 X 1 threaded entry complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection, dismantling blades and removing fan and blades to store complete all as specified and as directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose of connectors to fan complete all as specified and as directed.
Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
S & F LED T8 tube rod 4 feet 18 watts wall lighting linear lamp white color as per HPL Cat part product no HPLT81418PC(CW) or Equivalent in Havells/Bajaj
S & F LED tube fitting 4 feet 20 watts including tube with high power TPNs as light source and electronic driver designed in aluminim housing with necessary wiring electrical wiring complete all as specified and as directed. Make HPL , product code no HLPT51520CW or equivalent make in Havells/Bajaj.
S & F CFL light fitting, 1x11/15/18 w, 230v decorative wall mounting type with multicolour ABS housing with poly carbonate rings, and glass shade with lamp holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F isolator SPN, 40 A, 240 V complete all as specified and as directed.
S & F PVC rectangular block for mounting swtiches,sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of size 175mm X 100mm and 50mm deep.
Taking down old unserviceable submain wiring 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down existing sub main wiring complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of conduit will be measured and paid as one unit length.
M & L in repairs LT indoor panel board made of 1.6mm thick MS sheet duly powder coated with locking arrangement as per existing size(1200mmx750mmx250mm) including fixing in wall with an acrylic board of 8mm thick inside. Removal of and refixing of exixting electronic energy meters with replacement of following items. (a) MCB DBSPN 12 way - 01 No (b) MCB SPN 32 Amp 006 No all as specified and directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Shri Sai Electricals
M/S Anil Enterprises
M/s L. K. Agarwal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .