| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹1.1 CrAccepted-AOC | ₹1.1 Cr | l1 | Accepted-AOC l1 |
Tender Value
Refer Docs
Closing Date
6 Mar 2024, 5:00 pmClosed
Chandrapur Cancer Care Foundation
Chandrapur Cancer Care Foundation
F2_CCCH/V/Electrical/2024
2024_CHDPR_1003705_1
F2_CCCH/V/Electrical/2024
Open Tender
Miscellaneous Services
Item Rate
70 days
chnadrapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
27 Jun 2025
13 Feb 2024
7 Mar 2024
13 Feb 2024
6 Mar 2024
13 Feb 2024
Amount
F2. ELECTRICALAND ALLIED WORKS
External lighting-Feeder Pilar High Mast Light Supply, installation, testing & commissioning of 16M High masts with following:Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 570 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OHPL/HM (excluding luminaries)
External lighting-Feeder Pilar 16 nos. LED light fixtures as per Crompton Greaves catalogue no. LSFO-C300-CDL-60 with 1x300w flood light with minimum lumen/ lamp 31000 ( For 1 Set 16 nos LED Light)
Boom Barrier System Supply, installation, testing and commissioning of automatic boom barrier suitable for 5.0m-7.5m road width forintensive applications, high speed with 4.5 second opening time with Straight aluminium boom of minimum size 100mm x 70 mm, builtin blinker indicator etc. complete asrequired as per specifications & at site of work.
Boom Barrier System Supply, installation, testing and commissioning of a set of Entry/ Exit push buttons for manual open and closing of barrier etc.complete as required.
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Main LT Panel Dimensions : 14 m (W) x 1.5 m (D) x 2.2 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup HT Panel Dimensions : 3 m (W) x 2 m (D) x 2.2 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup DG Panel Dimensions : 6 m (W) x 1.5 m (D) x 2.2 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Fire Emergency Panel Dimensions : 5 m (W) x 1.2 m (D) x 1.8 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Lift Panel-1 Dimensions : 2.5 m (W) x 0.6 m (D) x 1.6 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Lift Panel-2 & 3 Dimensions : 1.1 m (W) x 0.6 m (D) x 1.6 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Capacitor Panel - 1 & 2 Dimensions : 2.5 m (W) x 1.5 m (D) x 2.2 m (H)
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup UPS Panel - 1 & 2 Dimensions : 2.5 m (W) x 0.6 m (D) x 1.6 m (H)
KITCHEN HOOD SUPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Kitchen Hood Suppressions System including the following 9 Liters FireDETEC ® F/K ea stainless steel cylinder, ILP Cylinder/valve assembly, mounting bracket, Flexible Hose, SS Tube fittings, Tube clamps, FireDeTec tube ( Grey) alongwith cross panel fittings , FDT tube clamps , Manual Release Device , with Pressure Switch and T connectors SS Tubing Nozzle 1 hole for kitchen system / R 1/4" / Stainless steel / Class F agent Alarm Box
Gas Shut Off Valve
TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-1)
TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (BATTERY ROOM-1)
TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (SERVER ROOM-1)
TOTAL ROOM FLOODING SYSTEM 1x34 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 34 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-2)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .