Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.3 Cr+₹14.2 L (3.44%)Rejected-Finance | ₹4.3 Cr+₹14.2 L (3.44%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹4.6 Cr+₹40.8 L (9.84%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹4.6 Cr+₹40.8 L (9.84%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹4.6 Cr
EMD Value
₹5.4 L
Closing Date
15 Jul 2021, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone
ADDN ALTN TO CERTAIN BUILDINGS OF MH AT JAMNAGAR MIL STATION
2021_MES_441682_1
800545/JAM/2021-22/E8
Open Tender
Civil Works
Item Rate
540 days
Jamnagar
Please refer tender documents
9 documents required · 9 mandatory
₹2,000
AGE (I) (A) Jamnagar
₹5.4 L
Yes
HQ CE Jodhpur Zone
23 Aug 2021
10 May 2021
17 Jul 2021
10 May 2021
15 Jul 2021
16 Jun 2021
20 May 2021
Amount
Demolition of stone slabs and tiles of any description or thickness in floors and aprons etc. laid, bedded and pointed in any mortar and removing from site all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on brick or concrete surfaces.
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4.
M&L for 18-20 mm thick granite (Black/Red or as directed) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed in CM 1:4.
M&L for machine cut kota stone slab 20-25 mm thick in flooring over and including 15 mm thick cement screed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in CM 1:3 on stone masonry surfaces and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations.
M&L for vitrified ceramic light shade tiles 9 to 10 mm thick(square/rectangular) polished, area of each tile n. exc.0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.
S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B weight of section frame 1.248 kg/m and shutter section weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness,aluminium wire cloth 0.45 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc. complete all as specified and directed. Note : Quoted rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc (Make: Jindal/Hindalco/Indal)
S&F powder coated anodised aluminium ventilator with fixed aluminium frame of size 65 x 40 x 1.98 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified.(Make: Jindal/Hindalco/Indal) Note : Quoted rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc
S&F powder coated anodised aluminium alloy sections door frame weight 2.863 kg/m and 12 mm toughened glass shutter Jindal or equivalent duly fitted with neoprene beading, glazing clips, glass panes 12 mm nominal thickness aluminium alloy handles etc. complete all as specified and directed.(Make: Jindal/Hindalco/Indal) Note : Quoted rate shall include all joining, locking arrangements, handle etc
S&F mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works.
S&F in repairs 25 mm dia stainless steel curtain rod, fancy type/decorative type, fixed on brackets fixed to walls with decorative knobs on sides complete all as directed.
S&F in repairs curtain rod side brackets of stainless steel, angular or cantilever type fixed to wall with 02 Nos. screws on each bracket and fitted screws for fixing curtain rod incl CP/stainless steel carved decorative design plain metal colour nobs with fixing arrangement for curtain rod using a screw complete all as approved and shown by Engineer-in-Charge.
Taking down tarfelt with plaster below felt over roof etc. and removing from site all as specified and directed. NOTE:- This item shall be executed for roof portions where demolition of PCC padding is not involved. Wherever demolition of PCC padding with tarfelt and plaster is involved, the same shall be measured and paid under item No.18 here-in-after.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc.) including tarfelt, plaster etc. and removing from site all as specified and directed.
M&L for cutting out cracks to V-section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof of any thickness.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) weight not less than 3.00 Kg/sqm and reinforced with non-woven polyster reinforcement/mat (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS-3384) @ 300 gm/sqm and applying two coats of aluminium paint 0.20 litre/sqm complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compound.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc. and removal of rubbish off all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surface other than fair faces of brick work or on one side of lathing, finished even and smooth without using extra cement.
M&L for dubbing out average 15-18 mm thick (whenever specifically ordered in writing by Engineer-in-Charge) in CM 1:4 on irregular face of walls. NOTE:- The surface of the dubbing out coat shall be left rough or scored to provide key for the top plaster coat.
M&L for rendering 5 mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair faces of brick work or on one side of lathing. Note:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces in ceiling including finishing even and smooth without using extra cement.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick Birla/JK wall care putty all as directed.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash.
M&L for preparation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M&L for complete removal of existing treatment from walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick Birla/JK wall care putty all as directed.
M&L for complete removal of existing treatment from walls andapplying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
M&L for preparation of old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying one coat of white wash all as specified and as directed by Engineer-in-Charge.
S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white/ivory, with and including plastic water closet seat, white/ivory, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, and fixed with and including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including CI 'P' or 'S' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish with and including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified.
S&F in repair health faucet (with 1.50 mtr tube) fixed to Angular Stop Cock and complete wall hanging arrangement complete all as specified and directed as per cat part No. BEA-86 of Make-Prayag or equivalent of any make specified.
S&F in repairs vitreous china urinal, half stall type, white complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, brass chromium plated perforated waste coupling, fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete all as specified.
S&F in repairs counter sunk vitreous china wash basin (560x410x180mm), white, including mounting on granite slab 20 mm thick brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete all as specified.
S&F 32 mm bore brass chromium plated bottle trap for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap.
S&F in repairs chromium plated, fancy type, centre hole WHB mixer without popup as per cat part No. 6750 of Make-Prayag or techno commercially equivalent of any make specified.
S&F in repairs 15 mm bore brass CP mixer for mixing hot and cold water screwed down for iron pipe as per cat part No. 6775 of Make - Prayag or techno commercially equivalent of any make specified.
S&F in repairs brass chromium plated over head shower with arm 255 mm with flange, fancy type, with or without swivel joints including fixing to steel pipe or union as per Cat part No. BS-73 of Make - Prayag or techno commercially equivalent of any make specified..
S&F in repairs brass chromium plated tubular towel rail, as per cat part No. BA-01 of Make-Prayag or techno commercially equivalent of any make specified.
S&F in repairs brass chromium plated towel rack, as per cat part No. BA-03 of Make-Prayag or techno commercially equivalent of any make specified.
S&F in repairs brass chromium plated soap dish, fixed to plugs with chromium plated brass screws as per cat part No. BA-05 of Make-Prayag or equivalent of any make specified.
S&F in repairs toilet paper holder, fancy type, fixed to plugs with chromium plated brass screws as per cat part No. BA-08 of Make-Prayag or equivalent of any make specified.
S&F in repairs corner glass shelf 300 mm wide as per cat part No. BEA-43 of Make-Prayag or equivalent of any make specified.
S&F in repairs 15 mm bore angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions as per Cat part No. PR-544 of Make-Prayag or techno commercially equivalent of any make specified.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm and stainless steel waste coupling of size as per trade pattern and PVC waste pipe of suitable length, complete all as specified.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site.
Supplying and laying of 16 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including cutting grooves, filled with CM1:6 complete all as specified.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including cutting grooves, filled with CM1:6 complete all as specified.
S&F in repairs 15 mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F in repairs 15 mm bore bib taps (long body), cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
Dismantling water tanks of any description, exc. 500 & n. exc. 1000 litres capacity and removing from site.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes.
S&F 25 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 25 mm-455 gms.)
S&F in repairs 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.
S&F in repairs 75 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.
S&F in repairs 110 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius.
S&F in repairs 75 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius.
M&L in repairs for PVC (SWR) floor trap, suitable for type ‘B’ pipes, 75 mm dia of outlet, plain with grating including jointing with solvent cement.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection. Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3).
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets/AC boards, any thickness, including cover fillets and grid and removing from site all as specified.
M&L for galvanised iron frame work, size of grid 605 x 605 mm, for seamless ceiling comprising of GI perimeter channels 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flange of 15 mm each and web 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
M&L for suspenders/Hangers 6 mm dia. G.I. wire (upto1200mm length) adjusting level fixed to roof slabes/trusses by means of ceiling cleats made out of GI flat of size 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified standard galvanised sections in a grid size of 600x600mm complete.
M&L for providing and fixing Gypsum board 12 mm thick in ceiling fixed with screw as per manufacturer’s instructions.
S&F 1.40 m overall height Workstation Cubicle made out of PVC/WPV prelaminated sheet fixed in PVC 'C' channel of required size, reinforced/framed with MS tube complete including necessary fixing arrangement as per manufacturer/approved design complete all as specified and directed (Make : Rajshri or techno commercially equivalent of any make specified) with the following:-
S&F 40 mm thick cubicle partition made up of 36 mm thick EPS Panel core and 2 mm PVC laminated sheet fixed on either faces with PVC Taper 'C' Channel of size 100x50 mm and 75x50 mm, fixed to Precoated MS Square/rectangular tube 50x25 mm using MS angle balde of prescribed size. MS tube shall be fixed to floor using anchor bolts and MS cleat balde complete all as specifed in manufacturer booklet. Note : Measurement shall be taken on front elevation.
S&F built up cup board of 18 mm thick PVC/WPC laminated sheet with side vertical supports including fittings, channels, rollers, handle and locking arrangement complete all as specified and directed by Engineer-in-Charge. Note : Measurement shall be taken on front elevation.
S&F Desktop and verticle support made up of 18 mm prelaminted PVC/WPC sheet fixed with necessary cleats, floor clamps, reinforcement, etc complete all as specified and directed by Engineer-in-Charge (measurement shall be on front elevation) Note : Measurement shall be taken on surface area of sheet fixed.
S&F Keyboard plate made up of 18 mm prelaminated PVC/WPC sheet of size 0.65x0.4 m, fixed beneath desktop using necessary cleats, channels, rollers, etc complete all as specified and as directed.
M&L for removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls by using chiesel/hammer, cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement, clean loose rust from bars manually with brush, fixing new supplymentary bars if required, either by tying it with existing bars or by welding on it and applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed.
M&L for racking of cracks n. exc. 5 mm wide, preparation and crack filling with polymer modified/chemical based crack fillers by approved manufacturer and filling as per manufacturer's instructions in walls, roofs of any type or size (Make: Pidilite/Dr fixit, Fosroc, Boschme or techno commercially equivalent of any make specified) all as specified and directed.
All as per item No. 77 above but cracks exc. 5 mm but n. exc. 10 mm wide.
S&F rolled mild steel of grade Fe-410-W (Grade E-250) quality ‘A’ as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down shutters of any description exc. 1 sqm and n. exc. 2 sqm each and removing from site.
Taking down shutters of any description exc. 1 sqm and n. exc. 2 sqm each and refixing in same opening after easing and adjusting or cutting and necessary repair.
S&F second class hard wood (SAL), plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both sides (ISI marked) with 6 mm thick teak wood edging all round.
S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats.
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F 18/19 mm thick, prelaminated particle board, ISI marked, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work for doors, partitions, on wall, in cup boards/kitchen cabinets etc., in shelves, partitions and shelves of built in cup board, almirah, book case, toilet boxes, racks, pelmets etc. and similar works.
S&F teak wood lipping, 6 mm thick, fixed with nails to 19/20 mm thick block board or veneered particle board.
M&L for second class hard wood plain fillets of sectional area exc. 13 but n. exc. 25 sq.cm, square, rectangular or triangular in section, wrought, fixed with screws.
S&F hasp and staple of size 100 mm, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F 100 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F 150 mm size aluminium handles, cast type, anodised.
S&F stainless steel butt hinges, medium weight, of size 100 mm.
S&F stainless steel butt hinges, medium weight, of size 75 mm.
S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F aluminium (extruded section) body, door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/path etc. all as specified and directed.
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc. 6 m mean radius built in CM 1:6 all as specified and directed.
S&F cast iron work grade FG 150, ornamental work, unmachined, in brackets, gully traps, gratings, railing, balusters, hand rails, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles, articles exc. 5 kg each.
M&L for cutting holes of superficial area n. exc. 100 Sq cm, into or through cement concrete slabs, chajjas, etc. reinforced or otherwise.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
M&L for cutting holes into or through brick walls/stone walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required, superficial area n. exc. 150 sq. cm
M&L for roughening surface of old concrete by picking, sweeping clean and washing down with water to remove all loose dust etc.
M&L for 15 mm thick rendering on floor and vertical side of sunken floor of brick/concrete surfaces in CM (1:3) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement and finished even and smooth without using extra cement. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.
M&L for cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or techno commercially equivalent of any make specified) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) including curing treated surface for 24 hrs complete including applying evenly a coat of blown bitumen @ 1.5 kg/sqm over entire treated surfaces including spout holes complete all as specified, directed and as per manufacturer's instructions.
M&L for cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
M&L for 50 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement in bottom of sunken floors floors.
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Add to (or deduct from) item No. 116 above for every 3 cm or part thereof above or below 15 cm average depth. Note:- This item is for adjustment of rate only.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base.
S&F 60 mm thick, M-35 grade rubber moulded lacquer coated, coloured, machine pressed PCC interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006 laid dry over and including 25 mm thick screened river washed sand cushion.
M&L for providing machine made precast cement concrete 1:3:6 type C1 using 20 mm stone aggregate in kerb stone of any size as directed, fair finished exposed surfaces, including necessary excavation and earth work, with plain fair faces, including chamfers, weatherings, slightly rounded or chamfered angles and throating, as directed etc. and setting in CM 1:4.
Excavating in trenches in soft/loose soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
All as per item No. 121 above but exc. 1.5 m and n. exc. 3 m deep.
M&L for sand filling under floors or in foundations including watering and consolidation.
M&L for DWCPE (SN8) pipes, nominal 300 mm diameter, laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructionscomplete all as specified and directed. (Make- Supreme, Prince, Berlia or techno commercially equivalent of any make specified.)
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete.
M&L for 15 mm thick rendering in CM 1:4 on brick work or concrete surfaces mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
S&F salt glazed stoneware gully traps of size 150x150 mm, square or round mouthed, type ‘P’.
M&L for cutting holes into or through brick walls walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required, superficial area exc. 150 sq. cm but n. exc. 400 sq. cm.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
M&L for mild steel TMT bars 6 mm to 8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for 150 mm bore reinforced concrete pipes class NP3, laid and jointed complete with collars.
M&l for cutting into existing manholes for connecting new drains of 150 mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under and haunching against the sides of pipes after they are laid and tested.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
Excavating in trenches in hard/dense soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Excavating in trenches in soft/disintegrated rock (demolition of PCC and stone masonry below GL), n.exc. 1.5 m wide and n. exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n. exc 1.5 m in depth and getting out.
Removing excavated material (rock) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for PCC 1:2:4 type B0 using 12.5 mm stone aggregate in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, platform for PVC tank, and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L for rendering 10 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement.
M&L for rough cast plaster with stone grit as specified over and including rendering 10 mm thick in CM 1:3 on brick work or concrete surfaces.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site all as specified and directed.
S&F mild steel of grade Fe-290 (Grade E-165) in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets(for securing wire mesh etc.) including all necessary drilling , bolting or riveting, etc. and similar work.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts, etc. including provision of binding wire. Note:- Chain link fencing, line wires and tie bars shall be measured and paid for separately as “supply only”.
Supply only chain link MS galvanized fencing of 3.15 mm dia wire and 55 x 55 mm mesh size (pitch of wire). Note :- Weight of chain link fencing shall be checked/ascertained by a board of officer to be ordered by the GE before fixing.
Supply only mild steel of Grade Fe- 290 (Grade E-165) flat or round bars in line wire, tie bars.
S&F mild steel screw bolts, (machine made) 5 to 10 mm dia of neck, exc. 5 cm and n. exc. 10 cm long, with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut.
Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces.
Taking down DB with MCB any type/any size & single pole and neutral enclosure with two pin and earth plug with MCB including all connecting accessories.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete for the following :- (a) One light/fan point controlled by one, one way switch.
All as per item No. 152 above but one bell buzzer point controlled by one, bell push switch 5A.
All as per item No. 152 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed.
All as per item No. 152 above but one 3 pin 5 or 6 Amps socket outlet on independent board with other switches as directed.
M&L for modular point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, complete for one 3 pin 15 or 16 Amps socket outlet on independent board.
S&F modular switch 1 way 6 Amp, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amp, 1 module complete all as specified and directed.
S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket 6 Amp/16 Amp, 6 pin combined 2 module complete all as specified and directed.
S&F modular bell push 6 Amp, 1 module complete all as specified and directed.
S&F bell electric heavy duty Ding Dong type 230 volts single pole all as specified and directed by Engineer-in-Charge.
S&F modular fan step regulator, 120W, 2 module, hum free and connecting electrically all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F LED batten fittings 4ft 20 Watt (Min 1900 lumens) with clamps including PVC gutties and flexible wire and connecting to ceiling rose with surge protection not less than 4 KVA complete.
S&F LED Batten fittings 1ft 5 Watt (min 380 lumens) with clamps including PVC gutties and flexible wire and connecting to ceiling rose with surge protection not less than 4 KVA complete.
S&F recess mounting LED panel 18 W 160mm X 160mm luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover with surge protection not less than 4 KVA complete.
S&F recess mounting LED panel 40 W 2 X 2 luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover with surge protection not less than 4 KVA complete.
S&F and testing factory made sheet metal enclosure for MCB DB TPN 8 way 415 volt with double door, IP - 43 protection including MCCB 160, amps 4 Pole 25 KA adjustable type as incoming, duly with fixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connection all as directed by Engineer-in-Charge.
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly with fixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connection all as directed by Engineer-in-Charge.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 12 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F MCB triple pole and neutral 415 volts 32 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
S&F MCB triple pole and neutral 415 volts 63 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
S&F MCB single pole and neutral 240 volts any rating from 40 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
S&F MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down and refixing exhaust fan 225 mm sweep AC, 240 volts, metal body, in same location after cleaning, greasing and painting with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts etc and connecting up including provision of flexible wire from ceiling rose/connector to fan all as specified and directed by Engineer-in-Charge.
Taking down and refixing ceiling fan 1200 mm sweep AC, 240 volts, metal body, after cleaning, greasing and painting with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts etc and connecting up including provision of flexible wire from ceiling rose/connector to fan all as specified and directed by Engineer-in-Charge.
Taking down and refixing of existing water heater geyser 25 Ltr capacity Geyser, vertical type with complete accessories in same location after completion of bldg repair.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, fixing, testing and commissioning 30W LED security light fitting with system output of 3000 lumens & with dedicated street light optics, System efficiency of greater than 100lm/W luminarie should have pressure die cast aluminium LM6 housing. Luminaire should have dedicated street light optics for better uniformity & spacing. Luminarie should have air vents in housing for proper thermal management. Min IP preventation should be IP65. System power consumption (including driver losser) should not exceed 20W with surge protection not less than 10 KVA complete.
S&F security light bracket made out of GI pipe 25 mm light grade 1.0 m long bent to shape as required for LED fittings at site including MS clamp 2 Nos. made out of flat iron 25x 3 mm with necessary nuts, bolts and two coats of alluminium paint over a coat of red oxide primer all as directed.
S&F single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA as per Cat part No. 507811 of Make- Legrand or equivalent of any make specified.
M&L for taking down window/split type A/C unit 1.5/2.0 ton capacity (Indoor & Outdoor unit both in case of split AC) and washable servicing the same by complete cleaning & washing the dust by suitable blower machine method complete with and including filling of gas R-22 and pressure testing including welding, brazing replacement of filter/Strainer made of copper capilary tube, complete including refixing in original position, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
Supply, installation, testing and commissioning of the piped distribution system using medical grade copper pipes 22 mm OD X 0.9 mm thick manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 13348 grade and mechanical properties in accordance with HTM2022/HTM02-01, copper fitting should be as per above norms and plastic saddles will have brass/ss screws.
All as per item No. 187 above but 15 mm OD X 0.9 mm thick .
Supply, installation, testing and commissioning of Gas outlet points for Qxygen 4 Bar, and Vaccum. Front loading type outlets. Out let should be specific so that secondary device can not be attached. Flow rate exceeds the requirement of ISO 9170-1.The terminal out let should comply with ISO 9170-1:2008 certification for the following:-
Oxygen outlet with probe
Vaccum outlet with probe
Nitrous outlet with probe
Supply, installation, testing and commissioning of Medical Gas Alarm Panel Microprocessor based line pressure alarm digital type 1 gas service nitrous having following feature, Digital/analog display of line presure for all the services with factory calibrated pressure sensors, color coded LED display of line presure status (High-caution-Normal-caution-Low), Audible alarm for high and low pressure condition, test and alarm acknowledge (mute) facility. Mounted on Powder coated MS Box, Low voltage internal operation for safety with input power supply of 230V, 50 Hz AC High /Low indication with test facility.
Supply, installation, testing and commissioning of Medical Gas Alarm Panel Microprocessor based line pressure alarm digital type 2 gas service (O2/Vacuum) having following feature, Digital/analog display of line presure for all the services with factory calibrated pressure sensors, color coded LED display of line presure status (High-caution-Normal-caution-Low), Audible alarm for high and low pressure condition, test and alarm acknowledge (mute) facility. Mounted on Powder coated MS Box, Low voltage internal operation for safety with input power supply of 230V, 50 Hz AC High /Low indication with test facility.
S&F LINE ISOLATION VALVE 22 mm ball valve :-These shall be of the ball valve type and shall be constructed of Nickel plated brass body, PTFE seat and brass chrome plated ball. Line valve installation should be carried out as per HTM2022/HTM02-01 standards.
S&F ZONE VALVE BOX (WITH VALVES) Valve box -1 gas with NIST connection
S&F ZONE VALVE BOX (WITH VALVES) Valve box-2 gas with NIST connection
Supply, Installation, Testing and Commissioning main with middle frames 2+2 cylinder nitrous oxide Manifoldand should be suitable to withstand working pressure of 145KG/cm² along with 04 Nos. of high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous oxide . Top frame comprising of high pressure copper pipeof size 5/8"IDX7/8" OD with high pressure brass fitting made of high tensile brass, NRV and high pressure copper tail pipes made of high pressure copper pipe of size 3/16 inch IDx3/8 inch OD. The manifold will be hydraulically tested to 3500 psig. The manifold will be so designed that it shall suit easy cylinder changing and positioning, The system will have NRV valves for easy changing of cylinder without closing the bank.The cylinder will be placed with the help of cylinder brackets and fixing chains which will be zinc plated.
S&F Semi Automatic Nitrous oxide Control Panel with inbuilt visual alarm & non return valves for nitrus : Control panel will have two first stage regulators each capable of delivering 100-200 psig outlet pressure . It should comply International standard: HTM02-01/ NFPA-99 /ISO7396-1
S&F Emergency Nitrous oxide Manifold- (1+1) cylinder with outlet point, regulator and high pressure tube)
S&F Mox Regulator for emergency manifold of Nitrous oxide (1+1) cylinder all as specified and directed.
Supply installation, testing and commissioning of oxygen flowmeter with humidifier bottle, control with in range of 0-15 LPM. Body is made of brass chrome plated materials. The flow tube and shroud component are made of clear, impact resistant polycarbonate, ilters of stainless steel wire mesh, humidifier bottle should be made of unbreakable polycarbonate material and autoclavable at 121degree celsius temperature.
Supply installation, testing, and commissioning of Ward suction unit consist of a regulator with 0-760 mm gauge, a 600 ml reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 121 degree celsius temp, wall bracket for mounting the Jar
Supply installation, testing, and commissioning of Ward suction unit consist of a regulator with 0-760 mm gauge, a 2000 ml reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 121 degree celsius temp, wall bracket for mounting the Jar
S&F D type Nitrous oxide gas cylinder 7.1 Cum capacity (ISI Marked) without gas
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover for:- (a) One 3 pin 5 or 6 Amps switch socket combination on independent board.
S&F switch socket combination 5 pin 6 amps flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
Supply and Installation of Solar water heating system, Flat plate collector type, with heat exchanger of 200 litre per day capacity, with electrical heating back up all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes.
M&L for Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore all as specified and directed.
Supply and laying 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
S&F 20 mm bore bib tap, standard of PTMT, any colour screwed for iron pipe and fixed (minimum weight 20 mm - 125 gms)
S&F 20 mm bore stop valve of PTMT any colour, screwed for iron pipe and fixed (minimum weight 20 mm - 92 gms)
Supply, install, commissioning and testing of commercial air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V 50 HZ made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of synthetic enamel paint (oven baked) with MS-CRC 18 gauge square perforated suction grills aluminium alloy fans and single phase electric motor, nozzles etc complete with fittings and acessories so as to produce 1-1.5 m/sec air velocity at floor level for door openning as size 40" X 78". (P-273 cook house-02 Nos.,T-232 cook house-02 Nos.)
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250 mmx150 mm x40 mm
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 50 mm bore.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore.
Retrieving/taking out/taking down old unserviceable cable up to 50 sqmm size from duct/trenches/pipes/pole/wall etc. including stone patti/brick/PCC block cover and protection pipe and disconnecting the connections. Note:- Excavation and earth work shall be measured and paid for separately.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 10 Sqmm 2 core size. Note:- Excavation and earth work, sand cushioning, stone patti/PCC block cover and protection pipe etc. shall be measured and paid for separately.
All as per item No. 217 above but 16 sqmm 4 core size.
All as per item No. 217 above but 25 sqmm 4 core size.
All as per item No. 217 above but 35 sqmm 3.5 core size.
All as per item No. 217 above but 50 sqmm 3.5 core size.
Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 40 mm bore and connections including cleaning for refixing or removing from site.
Supply and laying 25 mm bore tubes, galvanized steel, medium grade, with all fittings, laid in trenches all as specified and directed.
Supply and laying 40 mm bore tubes, galvanized steel, medium grade, with all fittings, laid in trenches all as specified and directed.
S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F in repairs 40 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
Cutting existing steel tubing 40 mm bore for alterations or additions (Each cut measured).
dave engineering works
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .