Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC Q 49 NEAR DEOGHAR COLLEGE MAIN GATE PO PS DEOGHAR JH 814112 | DEOGHAR | DEOGHAR | JHARKHAND | 814112 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹6.0 L+₹15,702 (2.68%)Rejected-AOC | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹6.2 L+₹38,077.10 (6.51%)Rejected-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹6.7 L+₹82,202.10 (14.1%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹6.7 L+₹89,536.50 (15.3%)Rejected-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹6.6 L
EMD Value
₹13,200
Closing Date
3 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
RAMGARH CANTT
PROVISION OF 2 X GUARD POST WITH ELEVATED PLATFORM AT CSD DEPOT RAMGARH
2023_MES_617265_1
8300/3188/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE RAMGARH
₹13,200
Yes
2 Nov 2023
5 Sept 2023
10 Oct 2023
5 Sept 2023
3 Oct 2023
19 Sept 2023
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables /pipes ,foundations, laying of cable,shafts, well,cesspits, manholes etc. complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil exceeding 250 Mtr but not exceeding 500 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use & waste of form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregate) as in columns,pillars,piers,popst and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to sides of columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to sides and soffit of lintel Beam,floor/roof Beams, etc for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to sides of soffit of suspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed.
M&L for Brick work with sub class bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in reinforcement ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/ copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M & L for 100 mm thick plain cement concrete (1:4:8) mix, type D-2 (using 40mm graded crushed stone aggregate ) as in path,berm etc., finishing the surfaces even and fair without using extra cement, including 10 mm wide, 100mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work, complete all as specified and directed.
M & L for 40 mm thick plain cement concrete (1:2:4) mix, type B-1 (using 20mm graded crushed stone aggregate ) as in flooring, path,berm etc., finishing the surfaces even and fair without using extra cement, including dividing strips inserted in position,conform to design complete all as specified & directed. Note :Glass dividing strip shall be measured & paid seperately under respective item of BOQ.
Supply only 38 mm wide plastic dividing strips,1.5mm thick inserted in position,conform to design complete all as specified & directed.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:4 on concrete surfaces as in ceiling finished even and fair complete all as specified and directed.
M&L for rendering 15 mm thick on external surface of brick masonry /concrete surface etc in cement mortar (1:4) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newely plastered surfaces of ceiling and applying three coat of white wash on new ceiling surface complete all as specified & directed.
M&L for preparation of newly plaster surface of wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 complete all as specified and as directed
M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 Kg per Bag of cement , finished, even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed. Note:Water proofing compound will be measured and paid seprerately under respective item of "BoQ".
M & L for application of water proofing treatment using APP modified roof membrane over non accessible/non approachable RCC roof slab /chajjah/canopy /parapet wall( horizontal /vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & hot blown grade bitumen 85/25 @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /Sqm over APP Membrane.
Supply only liquid water proofing compound ISI marked. complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for following point wiring controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc.,including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
(a) One light point/ fan point/Exhaust fan point controlled by one one way switch
(b) One 3/5 pin socket outlet 5 amp on same board with other switches
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5Amp/6 Amp, flush type, universal, complete all as specified.
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified & as directed
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
S & F LED bulb of capacity 15 watt , lumen out put (500)lm ,length 102 mm dia 56 mm , base cap B-22 (ISI mark) ,three star rated lamp with all accessories complete all as specified and as directed by Engr-in-Charge.
S & F LED tube light fitting 1 x 20watt , 220 V, AC, decorative box type with driver ,holder including LED tube light surface and wall mounted LED batten PVC housing with polycarbonate diffuser and integrated electronic driver complete with all accessories ,driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fittingcomplete all as specified and as directed.
S & F building street lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover along with electronic driver type street light fitting 35/36 watt capacity LED and including all necessary accessories duly pre-wired, fixing on bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including all accessories duly pre-wired including provision of two core flexible copper cable of size 2.5 sqmm not less than 1.5 mtr long for connection completecomplete all as specified & directed.
S & F bracket made out of 40 mm dia GI pipe light grade 1.50 mtr long bend to shape as per site requirement fixed to pole /wall with 50mm x 6 mm size flat iron clamp -02 Nos,nuts & bolt of 12 mm dia 100 mm long with washer etc duly painted applying two coats of synthetic enamel paint over a coat of red oxide primer on mild steel exposed surface including prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth complete all as specified & directedcomplete all as specified & directed.
Supply & fixing sheet metal enclosure for double door MCB DBs phosphatised powder coated , single pole & neutral (SPN) suitable for 4 Way , 240 volts fixed on wall with suitable amp rated bus bar & neutral and earth bar , in proper position complete all as directed by the Engineer -in - Charge.
S & F miniature circuit breaker (MCB)(ISI marked) 415V, 10 KA 'B' Curve and current carrying capacity 32/40Amp, single pole & neutral (SP&N) in the MCB DB complete with connection testing and commissioning all as specified and as directed.
S&F miniature circuit breaker (MCB) SP 6 to 32 Amps ('B' Series) having current rating 10 KA,240 Voltin the MCB DB complete with connection testing and commissioning all as specified and as directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh,charcoal dust and common salt 15cm in layers all round the earth plate, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally and chamber of (size of pit 300 mm x 300 mm x 300mm internal diamentions) PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old/ unserveciable existing earthing & making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 6 Sqmm 3.0 core complete all as specified and directed.
M/s friend enterprises
M/S KAMLESHWAR SINGH
upadhyay engineers and consultant
M/S Parmar Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .