Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹28.3 L+₹4.8 L (20.4%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
7 Aug 2021, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA No CWE/HILLS/PGH/24 OF 2021-22 REPAIR / MAINTENANCE OF TRANSFORMERS, HT ACSR CONDUCTORS, POLES, VCBs AND ALLIED WORKS AT PITHORAGARH UNDER GE PITHORAGRH
2021_MES_456770_1
CA No CWE/HILLS/PGH/24 OF 2021-22
Open Tender
Electrical and Maintenance Works
Works
240 days
PITH0RAGARH
CLASS D
11 documents required · 11 mandatory
₹500
Yes
GE PITHORAGARH
₹52,000
7 Sept 2021
2 Jul 2021
9 Aug 2021
3 Jul 2021
7 Aug 2021
16 Jul 2021
3 Jul 2021 - 15 Jul 2021
Amount
Opening of top cover of transformer of capacity 50 to 150 KVA and taking out transformer oil in a separate container after disconnecting of HT/LT side electric connections from both the primary & secondary side of the transformer of any type / description (indoor /outdoor type) installed on pole / floor, for carrying out necessary repair / rewinding to HT/LT side after shifting the transformer to contractor’s work shop including taking out complete core assembly, Meggar the defective winding portion & taking out, cleaning the laminated core and rewinding with copper winding wire / strips of existing gauge / size, including re-assembling & testing on completion & installation the same at its origin position, complete all as directed by Engineer-In-Charge. Note:- (i). Note:- a. Copper winding wire / strip required for winding of coil shall be measured and paid separately supply only under respective item of BOQ.. (ii). Transportation, loading & unloading charges of transformer shall be deemed to be included in quoted rates. (iii). The cost for the dehydration of transformer oil if required shall be measured and paid separately under respective item of BOQ. (iv). The cost of insulation material such as paper, cotton tape, latheriod sheet, cork sheet etc shall be deemed to be included in quoted rates.
Opening of top cover of transformer of capacity 150KVA above & up to 400 KVA and taking out transformer oil in a separate container after disconnecting of HT/LT side electric connections from both the primary & secondary side of the transformer of any type / description (indoor /outdoor type) installed on pole / floor, for carrying out necessary repair / rewinding to HT/LT side after shifting the transformer to contractor’s work shop including taking out complete core assembly, Meggar the defective winding portion & taking out, cleaning the laminated core and rewinding with copper winding wire / strips of existing gauge / size, including re-assembling & testing on completion & installation the same at its origin position, complete all as directed by Engineer-In-Charge. Note:- (i). Note:- a. Copper winding wire / strip required for winding of coil shall be measured and paid separately supply only under respective item of BOQ.. (ii). Transportation, loading & unloading charges of transformer shall be deemed to be included in quoted rates. (iii). The cost for the dehydration of transformer oil if required shall be measured and paid separately under respective item of BOQ. (iv). The cost of insulation material such as paper, cotton tape, latheriod sheet, cork sheet etc shall be deemed to be included in quoted rates.
Supply only copper winding wire of existing gauge, suitable for step down transformer of any capacity, including winding of coils (HT) as per the manufactures design & specification to obtain rated KVA, complete all as directed.
Supply only copper winding strips of existing size, suitable for step down transformer of any capacity, including winding of coils (LT) as per the manufactures design & specification to obtain rated KVA, complete all as directed.
S&F in replacement temperature gauge 0 to 125 degree centigrade in transformers installed at different sites including with all accessories, complete all as directed.
S&F in replacement, air breather assembly complete with fresh blue colour silica Gel suitable for indoor/outdoor transformer of capacity 20 to 160 KVA, complete all as directed.
S&F in replacement, air breather assembly complete with fresh blue colour silica Gel suitable for indoor/outdoor transformer of capacity 175 to 400 KVA, complete all as directed.
S&F in replacement, drain valve of existing size, complete all as directed.
S&F in replacement, porcelain transformer bushing insulator suitable for 11/.433 KV for 50 to 75 KVA transformers complete all as directed
S&F in replacement, porcelain transformer bushing insulator suitable for 100 to 200 KVA transformers complete all as directed.
S&F in replacement, porcelain transformer bushing insulator suitable for 250 to 400 KVA transformers complete all as directed
S&F in replacement, cork sheet suitable for transformers top cover of capacity 50 to 75 KVA, complete all as directed.
S&F in replacement, cork sheet suitable for transformers top cover of capacity 100 to 400 KVA, complete all as directed
Supply & filling transformer oil as in topping up of transformer oil, installed at different locations in Cantt area after dehydration with dehydration machine to achieve required dielectric strength of oil 40 KV at 2.5 mm gap complete all as directed
S&F in replacement, LT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 50 to 75 KVA, complete all as directed
S&F in replacement, LT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 100 to 200 KVA, complete all as directed
S&F in replacement, LT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 250 to 400 KVA, complete all as directed
S&F in replacement, HT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 50 to 75 KVA, complete all as directed
S&F in replacement, HT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 100 to 200 KVA, complete all as directed
S&F in replacement, HT side brass stud with nuts, bolts & washers of existing size, suitable for transformer of 250 to 400 KVA, complete all as directed
Dehydration /filtration of transformer oil of existing transformers of capacity up to and above 40 KVA, installed at site with oil dehydration / filtration machine to improve the dielectric strength (not less than 40 KV at 2.5 mm air gap) of transformer oil including transportation of filtration machine at site etc. complete all as directed by Engr-in-charge. Note : (i) Test certificate shall be submitted before and after filtration for dielectric strength. (ii) Oil dehydration / filtration machine & other requisite equipments shall be arranged by the contractor at his own cost.
Supply and fix in replacement rubber seal/gland on HT/LT studs of transformer complete all as directed.
Cutting /Trimming the tree branches of any size touching /embracing the OH line of HT up to 1.50 m on both side of the over head line including collecting & depositing the retrieved timber at a place directed by Engr-in-Charge. Note : (i) Distance between two poles shall be measured as one span. (ii) The contractor ensure that there must be no damage to HT conductor / poles because of falling of tree’s branches. If any damage occur due to this, the same shall be repaired by the contractor at his own cost without any extra cost to the Govt. (iii) Contractor will fully responsible for any type of miss happening / accident (If any) happened during trimming of trees. (iv) Contractor’s will take proper shut down from MES installation before starting such type of work and clear it before resuming power supply.
M&L for applying two coats of black bituminous paint on old surfaces of wood, steel, iron, concrete, brick, stone, etc., after preparation of surfaces exceeding 10cm in width or girth, complete all as specified and directed.
M&L for clearing away all grass vegetation, saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish up to a distance 50.00 m outside the periphery of the area under clearance as in soft / loose soil and getting out including sprinkling anti vegetation chemical in complete area with spray machine, complete all as directed
M&L for hardcore of broken stone or boulders gauge of 40mm to 63 mm, deposited, spread and levelled in layers n exc. 15cm thick complete all as specified & directed
S&F 2nd class softwood, clean sawn boards or planks 40mm thick, width n exc. 25 cm, complete all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches as in sand cushioning to underground cable, complete all as specified and directed
Taking out old unserviceable underground cable from trenches / floor / road / wall / pipe / pole etc. of size 120 sqmm, 3 core complete all as specified & directed
Taking out old unserviceable underground cable from trenches / floor / road / wall / pipe / pole etc. of size 95 sqmm, 3 core complete all as specified & directed
Supply & laying of sub class ‘B’ old size bricks, laid flat i.e length of brick shall be laid across the length of cable for protection of under ground cable complete all as specified and directed.
Supply, jointing and testing of outdoor type cable end termination joint, heat shrinkable suitable for aluminium conductor cable of size 120 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
Supply, jointing and testing of outdoor type cable end termination joint, heat shrinkable suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
Supply, jointing and testing of indoor type cable end termination joint, heat shrinkable suitable for aluminium conductor cable of size 120 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
Supply, jointing and testing of indoor type cable end termination joint, heat shrinkable suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
M&L for preparing to old painted surfaces of transformer 11/0.433 KV outdoor/indoor/pole mounting of capacity 50 to 400 KVA after preparation of old painted surfaces by removing old paint by scratching with wire brush etc, after disconnecting HT/LT side connection from both primary and secondary side of transformer and apply two coats of synthetic enamel paint of grey colour with spray machine on outer body of the transformer and writing of letter HT/LT & SM / MES Nos. and making all HT/LT electric connections, complete all as directed by Engineer - in - charge. Note:- Compressor, spray machine and other necessary required equipment / T&P shall be arrange by the contractor at his own cost and no extra cost on this account shall be paid to the contractor.
M&L for cleaning & preparation of old painted surface of HT steel tubular pole complete and applying one coat of aluminium synthetic enamel paint including channels / brackets, street light brackets, cross arms and making black & white strips with yellow synthetic enamelled paint of 30cm height each alternative strip up to 1.5 m height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint with and including applying two coats of white wash on PCC coping complete all as specified and directed
M&L for cleaning & preparation of old painted surface of HT two pole structure complete and applying one coat of aluminium synthetic enamel paint including channels / brackets, street light brackets, cross arms and making black & white strips with yellow synthetic enamelled paint of 30cm height each alternative strip up to 1.5 m height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint with and including applying two coats of white wash on PCC coping complete all as specified and directed
M&L for cleaning & preparation of old painted surface of HT four pole structure complete and applying one coat of aluminium synthetic enamel paint including channels / brackets, street light brackets, cross arms and making black & white strips with yellow synthetic enamelled paint of 30cm height each alternative strip up to 1.5 m height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint with and including applying two coats of white wash on PCC coping complete all as specified and directed
M & L for repair / servicing of existing Gang Operated Device including replacing the defective parts and applying mineral Jelly, oil, grease after proper removal of carbon deposits, re-fixing of Switch Air Break Gang operated for triple pole, mechanically operated, mounted on isolators and steel frame with operating mechanism works from Ground level, complete all as specified and as directed. Note :- The cost of new spare parts required for smooth functioning of GOD shall be deemed to be included in quoted rates.
Supply and fixing in replacement pin type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia suitable for working pressure 11000 Volts grade complete all as specified and directed.
M&L for replacing existing unserviceable silica gel with new crystal clean silica gel in breather assembly of transformers, complete all as specified and directed
M & L for repair existing servicing of drop out fuse including replacing the defective parts and applying mineral Jelly, oil, grease after proper removal of carbon deposits, re-fixing the same after repair, complete all as specified and as directed. Note :- The cost of new spare parts required for smooth functioning of drop out fuse shall be deemed to be included in quoted rates.
M & L for in replacement of existing worn out jumper structure with new aluminium jumper (any type of conductor) (not less than 2.00 m) with new aluminium clamp including bolts, nuts & washers complete all as directed
S&F in replacement of Air break gang operated triple pole, mechanically operated, mounted on HT insulators and galvanised steel frame with operating rod of 25 mm dia medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt , 50 HZ, including supply of 12 Nos. insulator of appropriate size and drop out fuse carrier element, complete all as specified and directed
M& L for cutting of floor / wall / road / footpath up to the required depth for removal / taking out for checking of serviceability HT underground cable of any size / description and making good the same as per existing specification after relaying the same or new cable complete all as directed
M&L for complete maintenance & overhauling of 33 KV existing VCB of make any make / type / mode / capacity including dismantling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing unserviceable spare parts, reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing of all joints, bus bars, CTs, PTs, spouts metal parts and making VCB perfect operational in manual & remote mode, calibration & checking of tripping system of 33 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented in service by primary current injection method to ensure proper function of trip coil control circuit etc. During fault condition, setting to be done by expert from authorised agency of state electricity board including submission of calibration certificate, complete all as specified and directed. Note:- Minor spare parts required for smooth functioning of VCB shall be deemed to be included in quoted rates.
M&L for complete maintenance & overhauling of 11 KV existing VCB of make any make / type / mode / capacity including dismantling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing unserviceable spare parts, reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing of all joints, bus bars, CTs, PTs, spouts metal parts and making VCB perfect operational in manual & remote mode, calibration & checking of tripping system of 33 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented in service by primary current injection method to ensure proper function of trip coil control circuit etc. During fault condition, setting to be done by expert from authorised agency of state electricity board including submission of calibration certificate, complete all as specified and directed. Note:- Minor spare parts required for smooth functioning of VCB shall be deemed to be included in quoted rates.
Supply only the following items suitable for 11 KV VCB as approved by GE & Engr-in-Charge, complete all as directed (Make of VCB-Schneider / C&G / Arreava / ABB):- (a) Shunt tripping coil.
(b) Volt meter 0 to 15 KV digital type
(c) Ammeter 0/20 to 100/200 Amp digital type.
(d) Breaker control switch 10A 660V
(e) Electronic hooter
(f) Push button Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NO block, 22mm dia in red colour
(g) Push button Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NC block, 22mm dia in green colour
(h) Integrated LED pilot lamp suitable for operating at ( AC/DC) Red colour
(j) Integrated LED pilot lamp suitable for operating at ( AC/DC) Yellow colour
(k). Integrated LED pilot lamp suitable for operating at ( AC/DC) blue colour.
(l). Integrated LED pilot lamp suitable for operating at ( AC/DC) green colour
(m). Toggle switch assembly.
(n). Fuse holders for british pattern fuse links as per IS,13703 2A
(o). Fuse holders for british pattern fuse links as per IS,13703 5A
(p). TNC control switch
(q). Panel heater switch.
(r). Closing coil
Supplying and laying in replacement PVC underground cable, XLPE insulated, screened with extruded semi conducting compound in combination with copper tape (0.3 KA for 1 sec) cores laid up, inner PVC sheathed, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with stranded compact aluminium conductor, 11000 volts grade, cross sectional area 120 Sqmm, 3 core, confirming to IS:7098 (Part-II) with latest amendments, suitable for earthed system laid in duct / trenches/ along pole etc. including making connection, complete all as specified directed.
Supplying and laying in replacement PVC underground cable, XLPE insulated, screened with extruded semi conducting compound in combination with copper tape (0.3 KA for 1 sec) cores laid up, inner PVC sheathed, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with stranded compact aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core, confirming to IS:7098 (Part-II) with latest amendments, suitable for earthed system laid in duct / trenches/ along pole etc. including making connection, complete all as specified directed.
S&F in repair strip type heater 40/60 watt approx 4"/6" in length complete all as directed
Supply & top up distilled water in capacity of 5 Litre cane for filling in batteries in Battery Bank complete all as specified and directed.
Supply jointing and testing of straight through joint (heat shrinkable) suitable for aluminium conductor cable of size 120 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
Supply jointing and testing of straight through joint (heat shrinkable) suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as in earth continuity conductor provided in between earth test point terminal and up to the equipment including nuts, bolts & washers, complete all as specified and directed
Supply, installation, testing and commissioning of control / charging motor of approved make, in replacement of 11 KV, VCB type, complete all as directed
Supply and fixing, testing, commissioning of numerical earth fault and over current protection relay 33 KV with Aux supply of 20 to 110V AC/DC with 2 NO+2NC contact of existing make including necessary wiring complete all as directed. Note: All T&P & accessories required for testing shall be arranged by the contractor at his own cost and no extra payment shall be admissible to the contractor on this account.
Supply and fixing, testing, commissioning of numerical earth fault and over current protection relay 11 KV with aux supply of 20 to 110V AC/DC with 2 NO+2NC contact of existing make including necessary wiring complete all as directed. Note: All T&P & accessories required for testing shall be arranged by the contractor at his own cost and no extra payment shall be admissible to the contractor on this account.
Supplying, fabricating, fixing in position cross arms, bracings, supports, clamps and back plates, fabricated from in structural steel section any type /size /shape including nuts bolts washers, welding, bending hot or cold, drilling holes for bolts, in any shape or size as required at site, including painting with two coats aluminium paint over a coat of red oxide including dismantling of old unserviceable existing cross arms complete all as specified and directed.
Supply and fixing, testing, commissioning of electro mech. under & over voltage protection relay 11 KV of existing make with and including necessary wiring etc complete all as directed. Note: All T&P & accessories required for testing shall be arranged by the contractor at his own cost and no extra payment shall be admissible to the contractor on this account.
S&F anticlimbing devices, including danger plate comprising 2.24 mm dia galvanised steel barbed wire, two stranded with 2.00 mm dia bars wrapped spirally round poles to a length of 0.5 to 1.0 metre clamped and properly secured complete all as specified and directed.
S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 33000 volts grade complete all as specified and directed. Make : Rastriya/Jaipuria / BHEL
S&F in replacement disc type insulator, poprcelain, vitreous in single disc assy for tension with tension clamps for conductors, working pressure 11000 volts of size 145 mm gigh and 255 mm dia ball complete all as specified and directed. Make : Rastriya/Jaipuria / BHEL
Periodical services & maintenance of 33 KV Yard by providing one coat of synthetic enamel paint after preparation of old steel surfaces on the following items and writing the designation of equipments in English alphabets / letters complete all as directed:- (i) Transformer 33 /11 KV of capacity 5 MVA-02 Nos. (ii) Transformer 33 /0.433 KV of capacity 63 KVA-01 Nos. (iii) Structure and equipment of 33 KV VCBs-04 Nos. (iv) Structure of LA set and equipment of VCB-05 Nos. (v) Structure of isolator and equipment of VCB-05 Nos. (vi) Gantry structure complete bus bar system-01 No. (vii) Misc structure-01 lot. (viii) Street lights poles. (ix) Steel Gate -02 Nos. (x) All remaining structure misc-01 lot. (xi) Rolling shutters. (xii) Transformer 11/.433KV and feeder pillar box and fencing-01 No. (xiii) Fire Stand-01 No.
Supplying and laying factory made un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm, laid dry flat across the cable with length of whole PCC cover, complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600x600x6 mm thick burried in ground vertically to a depth ot less than 2.25 mtr below the ground level eith top edge of the earth plate surrounded 15cm thick layers of common salt charcoal dust starting from ground below 15 cm of earth plate upto 15 cm above the same. GI plate connected with galvanised steel of size 32x6 mm by means of GI nuts,bolts and washers, strips laid in 40 mm dia light grade GI pipe as protection from top of the up to test point (cost of protection pipr up to 7.5 mtr from earth electrode will be included in the rates quoted by the contractor) with following :-(a) Test point GI strip of size 32 mm x 6mm. (b) watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit (GI funnel should properly tightned on GI waterning pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits).(c) Earth pit 30x30 cm constructed in PCC 1:2:4 type BI exposed surfaces finished even and smooth with 15 mm thick cement mortor 1:6 including RCC pit cover 25mm thick with 2 Nos MS hadles of 10 mm dia suitable for carying of pit cover.(d) Angle iron frame made of 40 x40x4 mm angle iron for 300x300 mm PCC pit complete all as specified and directed. Note :- (i) Item includes the cost of 7.5 m GI pipe for protection of GI strip. (ii) Item includes cost of 7.5 m earth lead i.e GI strip 32x6mm. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M&L for earthing complete with GI earth plate electrode 600x600x6 mm thick burried in ground vertically to a depth ot less than 2.25 mtr below the ground level eith top edge of the earth plate surrounded 15cm thick layers of common salt charcoal dust starting from ground below 15 cm of earth plate upto 15 cm above the same. GI plate connected with GI earth lead wire of 4mm dia by means of GI nuts,bolts and washers, strips laid in 15 mm dia light grade GI pipe as protection from top of the up to test point (cost of protection pipr up to 7.5 mtr from earth electrode will be included in the rates quoted by the contractor) with following :-(a) Test point GI strip of size 32 mm x 6mm. (b) watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit (GI funnel should properly tightned on GI waterning pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits).(c) Earth pit 30x30 cm constructed in PCC 1:2:4 type BI exposed surfaces finished even and smooth with 15 mm thick cement mortor 1:6 including RCC pit cover 25mm thick with 2 Nos MS hadles of 10 mm dia suitable for carying of pit cover.(d) Angle iron frame made of 40 x40x4 mm angle iron for 300x300 mm PCC pit complete all as specified and directed. Note :- (i) Item includes the cost of 7.5 m, 15mm dia GI pipe for protection of GI wire.(ii) Item includes cost of 7.5 m earth lead wire of 4mm dia. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M&L stay assembly complete comprising of 7/10 SWG galvanized stranded stay wire of required length fixed to pole with and including FI clamp 50x6mm size, bolts, nuts washers, galvanized steel stay rod 16mm dia and 1800mm long with nuts, bolts and washers, stay bow 400x14mm galvanized steel plate 230 x 230 x 6mm two numbers, thimbles loop insulator size 65 x 90 mm clearance hole 16mm including two coats of aluminum paint over a coat of red oxide primer on exposed mild steel work as shown in electric plate No 1 of SSR Part-I 2009 on page No 495 including with and including the following :- (a) Excavation in post holes in any type of soil, returning, filling & well ramming including disposal soil to distance not exc. 50 m from starting points. (b) PCC (1:3:6), type C-2, using 40mm graded stone aggregate as in foundation. (c) Taking down existing unserviceable stay assembly and removing from site.
Supply and fixing in replacement steel tubular electric pole, swaged type, welded type, 410 SP-55 (11 meter long) in true vertical position, complete with CI base plate, pole cap, bolts, nuts & screws all as specified with and including the following:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia or as directed by Engr-in-Charge complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and writting pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
S&F in replacement HT lightening arrester metal oxide type (gap less) for outdoor use complete with all fittings and fixing arrangements, transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to GI earth wire 4mm dia including with manufacturer’s test certificate, complete all as specified and directed.
S&F in repairs cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed.. Make :- REYCHEM/ DENSON/ MSEAL
Labour & transportation for safely shifting of 11/0.433 KV transformer from one location to another location within Cantt Area and making connections and testing complete all as directed. Note: Any damage to transformer during shifting / transportation from one place to another place shall be made good by the contractor without any extra cost to the Government
Supply and laying 25mm bore, GI pipe, light grade, laid under roads / drain / culvert, fixed to poles, walls with & including flat iron clamps bolts / nuts / washers / fittings (if any), complete all as specified and directed.
Supply and laying 80mm bore, GI pipe, light grade, laid under roads / drain / culvert, fixed to poles, walls with & including flat iron clamps bolts / nuts / washers / fittings (if any), complete all as specified and directed.
Supply, installation, testing and commissioning of current transformer, indoor type, HT 11 KV ratio 100/50/5+5 of input VA-15 type KCT-02 conforming to IS-2705 Part-I of 1981, 50 HZ, HSV-12 KV accuracy limit factor ACP-10 insulation level class-1, 28/75 short time terminal current and hrs duration 13.1 KA for 3 second suitable for VCB of existing capacity, complete all as directed
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for under ground electric cables not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed
Removing excavated materials (Soil) n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified.
Supply, installation, testing and commissioning of current transformer, indoor type, HT 11 KV ratio 50/25/5+5 of input VA-15 type KCT-02 conforming to IS-2705 Part-I of 1981, 50 HZ, HSV-12 KV accuracy limit factor ACP-10 insulation level class-1, 28/75 short time terminal current and hrs duration 13.1 KA for 3 second suitable for VCB of existing capacity complete all as specified and directed
Supply and laying in replacement of HT high voltage insulation mat made of elastomeric polymers material having a high insulation resistance thus imparting total safety to human being from any leakage current having high insulation resistance of class A of size 2.5 mm thick and 1 m width suitable for 11 KV confirming to IS-15652 : 2006 including pasting of mat with SR-998 by adding thinner as per requirement complete all as directed
Maintenance of 2/4 pole structure by disconnecting all incoming & outgoing over head line conductor, jumper, joint and underground cable end terminal joint from GOD etc and rewinding / renewal of all joint with fresh joint, inserting PVC coloured sleeves over conductor including treatment of GOD contacts and ACSR conductor with conducting jelly, complete all as directed
Unbinding from insulators and Restringing / Restretching ACSR conductor of any size on HT poles including binding with 2mm dia aluminium binding wire all as directed. Note:- Cost of binding wire shall be deemed to be included in quoted rates
Unbinding and Restringing / restretching of GI earth wire 04mm dia on HT poles and including wire with 1.63mm dia GI binding wire all as directed. Note:- Cost of binding wire shall be deemed to be included in quoted rates
Supply & fixing in replacement ACSR conductor of any size & type including binding on existing HT poles or new poles with 02mm dia aluminium binding wire, complete all as specified & directed
Supplying, drawing and fixing in replacement of continuous GI earth wire / guard / cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on HT poles including taking down old rusted GI wire, complete all as specified and directed
S&F in replacement air breather assembly complete with fresh blue colour silica gel suitable for power transformer of capacity 5 MVA, complete all as directed.
Servicing of existing 33 KV Air Break Switch of rating up to 800 Amps by applying petroleum jelly after cleaning of contact by removing rust and deposited carbon including tightening of all loose connections and making good for operation, complete all as directed
S&F in replacementof danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with 25x3mm size MS clamps, bolts and nuts of approved size for HT 25 x 20 cm size complete all as specified and directed.
Supply and fix HT Electrical insulation tapes (Euro 8m PVC) for terminating high voltage cables, for insulation sealing of connection of wire and cable, for bus bar insulation, taransformer terminal insulation complete all as specified and directed.
KPELECTRICAL AND AUTOMATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .