| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC C 52 ADG NEI GUWAHATI PRIME APARTMENT FLAT NO 403 GS ROAD CHRISTAN BASTI AMRABATI PATH DISPUR GUWAHATI ASSAM 781005 | GUWAHATI | KAMRUP METROPOLITAN | ASSAM | 781005 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.3 L+₹75,530 (2.12%)Rejected-Finance | L2 | Rejected-Finance BecomeL2 |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Tezpur
GE South Tezpur, Mission Charlia
PROVISION OF ACCOUSTIC TREATMENT IN MULTIUTILITY HALL OF CERTAIN UNIT MISA CAMP UNDER GE (S) TEZPUR
2023_MES_627124_1
8817
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹85,000
Yes
18 Jan 2024
6 Nov 2023
18 Dec 2023
6 Nov 2023
14 Dec 2023
20 Nov 2023
7 Nov 2023 - 19 Nov 2023
Amount
Supply & Installation of perforated accoustic treatment available in 3 stylish designs fixing in position wall paneling at all heights with GRG ( Glass Fibre Reinforced Gypsum ) panels/tiles of size 600 x 600mm of approved texture, design and patterns.comprising of a frame made from especially fabricated galvanized mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling GI channel section of size 50 x 32mm fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastener with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glass wool of 50mm thickness (minimum density 24 Kg/Cum) is then to be inserted in the slots and finally GRG (Glass Reinforced Gypsum) non- combustible panels/tiles are to be screw fixed with self-Tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing compound and fiber joint tape roll 50mm wide (90 meter) roll and two coats of plastic emulsion paint over one coat of primer suitable for paneling as per manufacturer’s specification or as per direction of GE all complete. Note: (i) GRG sheet 10 mm thick (minimum) (ii) the moisture content less than 2%, humidity resistance of 99% , NRC 0.70 to 0.85 as per IS 8225:1987, Non Combustible as per BS 476 ( Part 4)-1970 and light Reflectance of 75% to 85% ( Minimum ). (iii) Make of - GRG (Glass Fibre Reinforced Gypsum) panels/ tiles - Diamond Ceiling/Armstrong/Everest or equivalent (iv) Make of rockwool :- RockwoolSunrock of Thermocare/Polybond or equivalent (v) Area of finished surface of wall panelling shall be measured for payment purpose. (vi) Contractor to submit the plan, elevation & sectional drgs and details specification for approval by GE before incorporation in work (vii) Necessary scaffolding work for provision of panelling work upto height of 9.0 m shall deemed to be unit rate quoted by the contractor
Supply & Installation in lower portion of wall channelled wood work perforated wall panels of thickness 15mm made of moisture resistant fiber board with minimum 595X595 wood veneer as per the approved shade species (Ist class harwood) & melamine finish. On the reverse side of the board shall have a special perform pattern where the visible surface has a "Helmhoitz" fluted perforation of 3mm width and 21 mm of visible panel each, the parties shall provide a fire reaction of Class of as per part 7 of BS 476, the edges of the panels shall be "tongue-and-grooved" to receive special clips for installation. the back of the perforated panel shall have sound absorbing non-woven mineral wool 50mm thick of density 24 Kg/Cum with acoustical flees having NRC of 0.72-0.8, the panel shall be mounted on special aluminium splines using clips provided by manufacture and as approved by the GE. (Based upon manufacture's Specification & Execution) NOTE:- (i)Make of -Ist class hardwood ( Teak/sisso) (ii)Make of rockwool :- RockwoolSunrock of Thermocare/Polybond or equivalent (iii) Area of finished surface of wall panelling shall be measured for payment purpose. (iv)Contractor to submit the plan, elevation & sectional drgs and details specification for approval by GE before incorporation in work (v)Necessary scaffolding work for provision of panelling work upto height of 9.0 m shall deemed to be unit rate quoted by the contractor (vi)Necessary fixing arrangement of panelling & mineral wool shall be obtained from manufacturer/specilised firm by the contractor and submitted for approval prior to execution of work
Supply & Installation of tiled false ceiling of approved materials (As mentioned below) of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. Note Please:- (i) Descriotion of ceiling Tiles:- 10 mm thick fully perforated GRG (glass fibre reinforced gypsum) manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 12.5 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. (ii) Make of - GRG (Glass Fibre Reinforced Gypsum) panels/ tiles - Diamond Ceiling/Armstrong/Everest or equivalent Make of rockwool :- RockwoolSunrock of Thermocare/Polybond or equivalent (iii) Area of finished surface o shall be measured for payment purpose. (iv) Contractor to submit the plan, elevation & sectional drgs and details specification for approval by GE before incorporation in work (v) Necessary scaffolding work for provision of panelling work upto height of 9.0 m shall deemed to be unit rate quoted by the contractor (vi) Note :- Only GRG false ceiling area will be measured flat from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm
Supply & Installation of false ceiling of approved materials (As mentioned below) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. Note Please:- (i) Description of False ceiling :- 12.5 mm thick square edge Gypsum Board, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I finished with two coat of plastic emulsion paint over a coat of primer (ii) Make of - Gypsum Board- Gyproc Make of rockwool :- RockwoolSunrock of Thermocare/Polybond or equivalent (iii) Area of finished surface shall be measured for payment purpose. (iv) Contractor to submit the plan, elevation & sectional drgs and details specification for approval by GE before incorporation in work (v) Necessary scaffolding work for provision of panelling work upto height of 9.0 m shall deemed to be unit rate quoted by the contractor (vi) Note :- No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm
Taking down carefully aluminium/ copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Material and labour point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including suitable size PVC casing and caping/ conduit (ISI marked) , including modular flush boxes suitable for 2 M to 12 M fitted with screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No. 6 above but One 3 pin 5 Amps socket out let points on independent board
All as per item No. 6 above but 5 Amp socket on same board with other switches.
M & L for point wiring with 2.5 Sq mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC casing and caping/ conduit (ISI marked) with accessories including modular flush boxes suitable for 3 M fitted with screws & washersalongwith continuous earth wire 2.5 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 votls grade with stranded copper conductor and connected to common earth dolly complete for one socket outlet 6 pin 15/16 amps on independent board
Supply and fixing Modular switch one way 5/6 Amp complete all as specified
Supply and fixing Modular switch one way 16 Amp complete all as specified
Supply and fixing modular socket outlet 2 in 1, 3 pin 5 A complete all as specified
Supply and fixing Modular socket outlet 16 Amps complete all as specified
Supply and fixing in repair ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 12 modules complete all as specified and as directed.
Supplying and fixing in repair two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping / conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
Supply and fixing recessed mounted 2' x 2 ' LED luminaire 42 watts for grid ceiling minimumm lumen output 110 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
Supply and fixing 12 W Surface panel mounted round LED downlight, aesthetically designed aluminium die-cast enclousers, with seperate replaceable constant current driver 12 watts, including necessary connection complete all as specified and directed.
Taking down of wall mounting fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and Refixing it back in position as directed by the Engr-in-Charge.
Taking down of Exhaust fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and refixing it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to exhaust fan as directed by the Engr-in-Charge.
Taking down high bay/ low bay light fittings of any type from ceilng of any height and deposite to MES yard and refixing it back in position with necessary clamp allas specified and as directed by Engr-in- Charge. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
sanjay upadhya
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .