Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-Finance | ₹1.1 Cr | L1 | Accepted-Finance Accepted as L1 |
| 2 | L2₹1.2 CrAccepted-Finance | ₹1.2 Cr | L2 | Accepted-Finance Accepted as L2 |
| 3 | L3₹1.2 CrAccepted-Finance NA | ₹1.2 Cr | L3 | Accepted-Finance Accepted as L3 |
| Sl No | Description | Qty | Unit | M/s Raj Construction L2 | Wood Stone Constructions L3 | SURJEET SINGH RANA L1 |
|---|---|---|---|---|---|---|
| 1.00Note: The Bidder must quote the values inlcuding Taxes. | ||||||
| 2.00EARTHWORKS | ||||||
| 3.00 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar | 80.34 | Cum | 3,337 ₹2.7 L | 3,338 ₹2.7 L | 3,000 ₹2.4 L |
| 4.00 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) | 14.75 | Cum | 3,304 ₹48,734 | 3,304 ₹48,734 | 3,200 ₹47,200 |
| 5.00 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction | 74.4 | Cum | 682 ₹50,740.80 | 682 ₹50,740.80 | 680 ₹50,592 |
| 6.00CONCRETE WORK | ||||||
| 7.00 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 20 Nominal mix 1:2:4 | 24.92 | Cum | 9,802 ₹2.4 L | 9,802 ₹2.4 L | 9,800 ₹2.4 L |
| 8.00REINFORCED CEMENT CONCRETE WORK | ||||||
| 9.00 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 R.C.C. grade M 25 | 57.58 | Cum | 11,669 ₹6.7 L | 11,669 ₹6.7 L | 11,300 ₹6.5 L |
| 10.00 | Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6) | 6.95 | Tonne | 86,246 ₹6.0 L | 86,246 ₹6.0 L | 85,000 ₹5.9 L |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
19 Sept 2025, 3:00 pmClosed
Executive Engineer, PIU PWD Badrinath
Office of Executive Engineer, PIU PWD Badrinath
Area Development of Bheem Pul under Mana Master Plan in District Chamoli
2025_pwd_86878_1
368/3AC-Nivida Dated 29.08.2025
Open Tender
Civil Works
540 days
Mana
2 documents required · 2 mandatory
₹4,720
EE PIU PWD Badrinath
₹2.3 L
Office of Executive Engineer, PIU PWD Badrinath
7 Jan 2026
4 Sept 2025
19 Sept 2025
4 Sept 2025
19 Sept 2025
5 Sept 2025
11 Sept 2025
Amount
Note: The Bidder must quote the values inlcuding Taxes.
EARTHWORKS
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
CONCRETE WORK
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 20 Nominal mix 1:2:4
REINFORCED CEMENT CONCRETE WORK
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 R.C.C. grade M 25
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6)
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :4 (1 cement: 4 coarse sand)
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed rubble masonry (1st sort) In 1:3 cement mortar
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Geotextile Filter (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.)
CLADDING
Providing and fixing cramps of required size & shape in RCC/ CC I Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 10 mm
NON-SCHEDULE ITEMS
70 mm thick fine dressed Local Himaliyan stone flooring for external works over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Himalayan Stone Cladding 50mm thick (450x200x50)mm
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 110 mm dia U-PVC pipes extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing & Laying 80 mm thick Cement Concrete cobble stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Jet Black with minimum average 300kg/cm2 (100x100x80) mm (+-5% of size)
Drilling Hole 32 mm For Rebar Dia 25mm Depth 640mm (With Compressor) Including the cost of Hilti RE-500 (item no. 2287554) .
Providing and fixing Second Class Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank.
Providing, laying and fixing of Second class Deodar Wood as in built runner having size of 100mmX75 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : (PU COATING) Two coats using aquulac Repellin WR-003/Durabuild D088
BASES AND SURFACE COURSES
By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. for grading- I Material
Wet Mix Macadam laying Using Mechanical Paver ( Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub?base / base course on well prepared surface and compacting with vibratory roller to achieve the desired
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
600 mm equilateral triangle
600 mm circular
600 mm x 600 mm square
HORTICULTURE WORK
Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately))
Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)
In rows 7.5 cm apart in either direction
Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm)
RCC MANHOLE :
Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality. pre-cast R.C.C. manhole cover and frame of required shape and approved quality. ELECTRICAL MANHOLES
EM-C-450x450x500mm ELECTRICAL & ELV MANHOLE
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kgs/CuM. Excess/ less cement used as per design mix is payable/recoverable separately).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centring and Shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Electrical Part (B)
LT PANEL
Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle Panel board. Detail specification shall be followed. Shifting of panels from site store to the suitable location. Assembling and wiring of component supplied separately. Earthing all components, frame etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job. Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. The rates for the distribution boards apart from the Breakers and instruments shall also include the following : This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosed. Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. If any TPN ACB’s / MCCB, it shall be with adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity.
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 4X for all Indoor panel. IP 54 and double door. All MCCB’s shall be provided with operating mechanism for door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. SPD as shown in SLD Approved Makes-L&T/ABB/schnider/Legrand/SIEMENS
DISTRIBUTION BOX
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8way, Double door (IP43, IK09)
Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing of weatherproof enclosure for double pole, 240 volts, MCB (6A-32A) complete with connections, testing and commissioning etc. as required. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB / HENSEL
Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB
CABLE & TERMINATION
Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.
Upto 35 sq. mm
Laying and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply, connection, testing and commissioning of heavy duty, medium voltage,XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified in specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS
4C x 16 Sq.mm. CU XLPE armored cable
4C x 4 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
3C x 2.5 Sq.mm. CU XLPE armored cable
CABLE TERMINATION
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI
4C x 16 Sq.mm. CU XLPE armored cable
4C x 4 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
3C x 2.5 Sq.mm. CU XLPE armored cable
INTERNAL WIRING
Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points.
Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FR PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring.
Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E) Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E) Cost of MCB shall not be considered in point rate. Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required- Group C
light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
Supply, installation, testing and commissioning of following sizes of HEAVY class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
SITC of 16A / 20A Single Phase IP66 industrial Plug Point with metal clad plug Socket / plug top with 20A DP MCB including weather proof box cover plate etc, complete in all respect, include switch, box, plate, etc. equivalent to Legrand Make Cat No. 056661
EARTHING
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. Approved Makes-OBO/ CAPE
LIGHT FIXTURES
20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures: 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make Philips /BN021C LED22S PSU CW GR S2/01 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI,LED Make CREE/Osram/Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies
Floor Recessed : (STEP LIGHT) Supply, Installation, assembling, connection, testing & commissioning of LED FIXTURE - NGB-M1A,1W,LED,3000k, IP 67 Light NGB-M1A: The housing in light weight, made of high strength die cast aluminium and coated by static powder making it weather resistant.Top AL diecast cap for two way light output . Premium thermal management by high heat conductivity aluminum alloy and thermal fins. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP67 rated. Height – 87mm, Dia.-110mm, Weight - 0.25Kgs. Power LED Module with high efficacy LED's, on Printed Circuit Board with metal core plate. CRI > 80,P.F>0.9,voltage input AC100-277V,50/60Hz. In- Built Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection. Estimated LED Lifetime is 70,000 hours minimum. . Sample Should be submitted for concerned engineer incharge for approval of light fixture. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI-LED FIXTURE - NGB-M1A,1W,LED,3000k, IP 67/Bega/DW Windsor
Wall Recessed LED Step Light : (FOOT LIGHT) Supply,Installation, Testing and Commmisioning of IP68, IK10 protected Step Light Fixture. Fixture made of powder coated die cast alluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.95 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with BIS With Stainless Steel Bracket for Wall Recessed LED Step Light : (FOOT LIGHT) * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Bega/DW Windsor
Floor Mounted Uplighter/Ground Buried : Supply, Installation, assembling, connection, testing & commissioning of LED FIXTURE,15W,LED, IP 68, IK08 LED-based recessed with trim directional inground luminaire, Glim with HPE (High-Performance Efficiency), system power: 15 W, Luminous flux of luminaire 910 lm, Colour temperature of 3000 K, Warm white, CRI > 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; energy-efficient LEDs, direct light emission, housing in die-cast aluminium with adjustable luminaire part, Polyester powder silver coloured coat applied over a 5-stage pre-treatment housing with stainless steel faceplate, Toughened glass cover with lens, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, integral electronic control gear, swivelling 15°, Protection class I, IP 68. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Bega/DW Windsor
Supply, Installation , Testing and Commisioning of 120 W LED Flood Light for application , BIS approved , Body made of pressure Die cast aluminium with separate driver chamber for ease of maintenence, proper fins should be designed for better heat dessipation ,adjustable bracket should be provided to adjust the tilt of light , primary diffuser should be PMMA/PC Lenses for Better photometry and wide area coverage , The secondary diffuser should be clear toughned glass with IK08 protection . The luminaire is provided with internal surge protection of 4 KV .Fixture is having external surge protection of 10KV. Electronic potted driver having power factor>0.95, THD <20 % and input voltage range from 150-270V AC at 50Hz. Minimum lumen 13200 Lumens in CCT range of 5700 as per ANSI,LED Make CREE/Osram/Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.Ambient Operating Temperature is -10 Deg. to 50 Deg. Luminaire should Maintain Ingress Protection of IP66 for better weather proofing. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Bega/DW Windsor
JUNCTION BOXES
Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE
Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes (300mm(L) X 300mm(B) X 170mm(H) with connector & including GEL. Equivalent to Hensel catalogue no MI 0201/OBO/CAPE
Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes (225mm(L) X 295mm(B) X 122mm(H) with connector & including GEL. Equivalent to Hensel catalogue no KF 3500 C/OBO/CAPE
DWC PIPES
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Providing & Laying of HDPE Pipe 32mm PE-80,PN6 direct in ground; to be laid 75-100cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering,or G.I. conduit 32 mm dia( Heavy Duty) with concrete block 15cm X 15cm 1:2:4 with complete curing with splicing complete in all respect complete in all respect. Make: Jain/Dutron/Supreme/reliance
M/s Raj Construction (BID ID -397930)
Wood Stone Constructions (BID ID -397432)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_103115.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid