Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC aCCEPTED | |
| 2 | L2₹11.8 L+₹1.4 L (13.1%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.1 L+₹1.7 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹11.8 L
EMD Value
₹29,390
Closing Date
22 Feb 2022, 6:00 pmClosed
Ancy Jose
Asst. EXECUTIVE ENGINEER LSGD DIVISION AYYANTHOLE THRISSUR 680 003
DPT 2021-22 KALABHAVAN MANI INDOOR STADIUM COMPLETION IN MURIYAD PANCHAYATH IRINJALAKUDA BP S0888/22
2022_LSGD_474031_25
TN-17/2021-22
Open Tender
Civil Works - Buildings
Item Rate
270 days
Thrissur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
₹29,390
Yes
19 Apr 2022
14 Feb 2022
24 Feb 2022
14 Feb 2022
22 Feb 2022
14 Feb 2022
Amount
stadium compltion
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
50.6.1.7 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
15.7.2 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In lime mortar with old mughal bricks
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od1641926/2021_2022 : Roofing with G.I hard colouur powder coated traffod sheets 0.35 mm thick or nearest availablethickness with overlaps of 150 mm at ends and GI hook or crank C.I. bolts and nuts includingplain washers and bitumen washers etc complete
od1641927/2021_2022 : Supplying and fixing PRESSED STEEL DOOR of standard pattern with frames as per profile IS 4351 of sections 105*60 mm using 18 g (1.2mm thick CRCA) sheet and shutters made of section 75*30 cm of outer styles and horizontal members and then inserted with enclosed and stiffened sheet 26 CR as per the specification with zincromate primer including all charges of fittings,conveyance etc complete
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.33.1 : 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with:Second class teak wood
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
50.18.9.14.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.16.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
od1645681/2021_2022 : Flooring with Interlocking cobbles 60mm thick (premium) Minimum strength 4 kg/cm2 over a bed<br>of 6mm metal filling in 50mm average thick and compacting using earth hammer /compacting<br>machine hand operated including cost and conveyance of all materials labour charges, , pointing<br>edges etc complete.
Unnikrishnan K K
Tomy. I.K
Bidder Name
Tomy. I.K
Unnikrishnan K K
ROBIN JOSE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_680604.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .