Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.2 L+₹79,799 (1.93%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹42.6 L+₹1.2 L (2.98%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹43.3 L+₹1.9 L (4.59%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹43.7 L+₹2.3 L (5.52%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
9 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
COMPREHENSIVE MAINTENANCE OF B/R AND INTERNAL E/M WKS TO MD AND OTM ACCN AT ASC SUP COY, CWE(S) AND GE OFFICE, MES QTRS, ECHS, ARO, AALC, NCC BARRACKPORE UNDER GE BARRACKPORE
2023_MES_614469_1
8819/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹81,000
Yes
7 Oct 2023
18 Aug 2023
11 Sept 2023
18 Aug 2023
9 Sept 2023
2 Sept 2023
Amount
PART-I Taking down chowkats with shutters of wooden/PVC/Steel/aluminium (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters of wooden/PVC/Steel/aluminium (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed. (Note for Item No. 1.00 & 2.00 - Rate shall be deemed to be include for cutting holes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces).
Taking down chowkats with shutters any type (without taking off shutter from the frames)not exceeding 1.50 Sqm and refixing in same opening after easing and adjusting complete all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floors or paving no exceeding 15cm thick below or above ground level complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided for complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Dismantling of battens for tiles, shingles etc of any size including tilting fillet exceeding 15 cm complete all as specified and directed.
M&L for brick work with subclass 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
Taking down old bituminous felt including PCC, screed bed (any thickness) and vegetation and disposed off to a distance not exceeding 50m and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting exceeding 10 cm but not exceeding 20cm girth complete all as specified and directed.
M&L for cutting holes into or through brick walls built in cement mortar or stone walls built in lime or cement mortar to a depth of embedded portion exceeding one brick but not exceeding two brick for inserting hold fast etc and making good dismantled portion with cement concrete (1:2:4) type B-1 complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in fixing hold fast, coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in shelves and like etc complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings, shelves and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required dia of pipe 150 mm complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
S&F of second class hard wood in fillets, square, rectangular or triangular in section, clean swan, fixed with nails or brads, sectional area exceeding 13 sqcm but not exceeding 25 Sqcm complete all as specified and directed.
S&F of 35 mm thick plain framed pannelled shutters (factory made) feather edged (any numbers of panels) with both sides or venneered particle board medium density wood particle board with commercial face venners supply and fitted to chowkat complete all as specified and directed.
S&F of 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made) for windows & doors open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section-8, Clause 8.24 (b) (larger size to be provided) complete all as specified and directed.
S&F in repairs of 25mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc complete all as specified and directed.
S&F of aluminium bracket (heavy duty), powder coated of best quality as approved suitable for fixing 25mm bore curtain rod fixed in wall complete all as specified and directed.
S&F for joist, channel, flat iron, angle or tee sections, fixed independently, with connecting base plates etc as in fencing post, struts, bend to shape, holes, drilled/notches cut out to received MS bolts and barbed wire embeded to concrete including tarring to steel work embdede to concrete of Fe 410-W (Gde E-250) quality A complete all as specified and directed.
S&F in repairs of aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg as fixed complete all as specified and directed.
S&F in repairs of continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 30mm complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F in repairs of mortice lock, brass vertical type, size 100mm with 4 leavers complete all as specified and directed.
S&F in repairs of mortice lock, brass vertical type, size 75mm with 4 leavers complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in window and door shutter complete all as specified and directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed.
S&F for 75 mm size extruded brass handle, fabricated type(as per IS-208 : 1996), polished complete all as specified and directed.
S&F in repair of 75 mm long aluminium anodised extruded alloy handle fabricated type(as per IS-208 : 1996) complete all as specified and directed.
S&F of 100 mm long aluminium anodised hasp & staple safety type including hinge pin, bolt to hinge plate etc complete all as specified and directed.
S&F of Mild Steel hold fast or fan hook of flat iron 25mm x 6mm complete all as specified and directed.
S&F of double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F of ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F for auto closing hydrolic hinges fixing with particle board with approved size and design complete all as specified and directed.
S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass including taking down old unserviceable steel window complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F of rolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, double leaf (side hung type) without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges type B-21 100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etc including locking arrangement, roller complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller after complete all as specified and directed.
S&F of anodised aluminium frame of doors, windows, ventilators with one or more rebates including joining cleat for fixing for complete all as specified and directed.
S&F of steel ventilators with top hung shutters including hinges, steel peg stay including taking down old unserviceable steel ventilators complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
S & F for 605mm X 605mm grid GI frame work for seamless false ceiling compising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm eachn and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including 12mm Gyspsum Board in ceiling fixed with screw as per manufacturers instructions for insulation/acoustic purpose of 600mm x 600mm in size fixed with snap grid flase ceiling frame and 0.55mm thickness having jurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with conccecting clips across the intermediate channel at 457mm centre to centre and Hangers 6mm dia GI (upto 1200mm length) adusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
M&L for solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement & fixing at site on PVC frame as per specification and drawing as mentioned in SSR Part-II (2020), Section-8, Page No-180 complete all as specified and as directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing as mentioned in SSR Part-II (2020), Section-8, Page No -180 complete all as specified and as directed.
S&F of 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with 'L' or 'J' type hooks including taking down old unserviceable AC sheet complete all as specified and directed.
M&L for cutting out cracks to V-Section existing roofs or terracing cleaning out, wetting, grouting with cement & sand slurry (1:3) complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete etc all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 12mm thick medium density fibre board, exterior grade, fixed with screws/beading to aluminium frame work complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint complete all as specified and directed.
M&L for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminum frame work for cupboard shutter including taking down old unserviceable one complete all as specified and directed.
M&L for 50 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, paving, floor, hard standing, sub base floor etc including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 25mm (avg) thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 18-20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for joint free coloured vitrified ceramic tiles 8 to 10mm thick (square/rectangular) polished, light shade, area of each tile not exceeding .36 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block (coloured and polished) any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying over & including 50mm thick sand filling complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling/soffit of chajjas, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick plastering in cement mortar (1:3) on concrete surfaces of sunken floor mixed with WPC @200ml/50 Kg of cement finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item)
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with WPC @200ml/50 Kg of cement, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick screed bed in cement mortar (1:4) on concrete surfaces of roof as levelling course mixing with WPC @200ml/50 Kg of cement, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after complete removal of existing paint and preparation of old wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for preparing surfaces of steel and iron work, new or old treating small articles such as strip, covers, gully gratings, hold fast ends of post, beads of chowkats etc area tarred not exceeding 0.1 sqm and treated with tar or coal tar black paint complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty newly plastered surfaces of wall after and including preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty old decorated plaster surfaces of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty newly plastered surfaces of ceiling after and including preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after complete removal of existing paint and preparation of old steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for complete removal of existing wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @0.90 litre/ 10 sqm over old surfaces complete all as specified and directed.
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed.
S&F of 5.5mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F of 5.5mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 3mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane fixed with putty or beads complete all as specified and directed.
S&F in repairs of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F in repairs of shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed.
S&F in repairs of 15 mm bore stop valve/angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of 15 mm bore stop valve, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F in repairs of 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs of vitreous china wash basin, white, flat back, size 630 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repairs of 15mm dia pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F in repairs of 20mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete all as specified and directed.
S&F in repairs of 125mm dia grating with waste hole , fancy type, chromium plated complete all as specified and directed.
S&F in repairs of 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed
S&F in repairs of sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs of health faucet fixed to EWC with 1mtr long easy flexible tube of 8mm dia and wall hook complete all as specified and directed.
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F in repairs of vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap type (excluding flushing cistern & flush pipe) including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipe out in with and including white seat cover etc. including making good to floor complete all as specified and directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar (1:6) complete all as specified and directed.
S&F in repairs of 15 mm dia PVC connection pipe of length 450 mm with 02 Nos brass check nuts complete all as specified and directed.
S&F of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc.complete including taking down old unserviceable pipe all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F of 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm dia ball valve high pressure of PTMT (minimum weight 455 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
Disconnecting existing water tanks of (exceeding 500 & not exceeding 1000 litres in capacity), setting aside (or lowering if required) and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in position with required fittings complete all as specified and directed. (NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank)
S&F in repairs of 20mm dia ball brass valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for any dia pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed.
S&F of 25mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable pipe complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable pipe complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC (SWR) in 'P' trap complete all as specified and directed.
S&F PVC (SWR) in 'S' trap complete all as specified and directed.
S&F in repair of wall mixer 3-in-1 system with provision for both hand shower and OH shower complete with 115mm long bend pipe, connecting legs & Wall Flange (without hand & over head shower) complete all as specified and directed.
S&F in repairs of 15mm bore wall mixer L-bend (provision of OH shower) fancy type chromium plated cast copper alloy complete with 115mm long bend pipe on upperside connecting legs and wall flange complete all as specified and directed
S&F in repairs of CP wash basin mixer for mixing hot & cold water screw down for iron pipe including necessary connection pipe from stop cock complete all as specified and directed
S&F of flexible tube 8mm dia and 1.5m long with nuts for hand shower fixed with wall mixer complete all as specified and directed.
S&F in repair of chromium plated towel ring of 200mm dia with round flange complete all as specified and directed..
S&F in repair of toilet paper holder fixed to walls with chromium plated (CP) brass screws all as specified and directed by Engr-in-Charge.
S&F in repairs of CP over head shower multi flow without arm of 125mm dia with flange joints including fixing to steel pipe or union of 15mm dia complete all as specified and directed.
S&F in repairs of CP round double rain shower without arm with flange, joints including fixing to steel pipe or union of 15mm dia complete all as specified and directed.
S&F in repair of chromium plated Towel rack 600mm long with lower hangers complete all as specified and directed by Engr-in-Charge.
S&F in repairs of CP shower arm 20mm dia and 225mm long for wall mounted shower with flange joints including fixing to steel pipe or union of 15mm dia complete all as specified and directed.
S&F in repairs of Corner glass shelf (large) 300 X 300mm (12" x 12") complete all as specified and directed.
S&F of stainless steel plate rack (0.63 mm thick s/s sheet) of size 775mmX900mmX250mm fixed in wall with stainless steel screw of suitable size complete all as specified and directed.
Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Demolished the existing damaged concrete from sunken portion carefully upto RCC slab including taking out of water closet and traps etc (depth approx 400mm) (b) Cleaning the existing RCC sunken slab and vertical wall/RCC beam as per direction. (c) 15mm thick plaster over the flat and vertical surface in CM (1:4) mixed with WPC as per manufacturer's instruction. (d) Applying two coats of elastomeric acrylic water proof coating using rooler, each coat of elastomeric actylic compound required 6-8 hrs to dry, second coat shall be applied on fetting the first coat complete dry consumption of materials shall be as per manufacturer's instruction. (e) Filling the sunken portion with PCC (1:5:10) type E2 with using 40mm graded stone aggregate. (f) After complete treatment of RCC sunken portion same shall be tested with 72 hrs ponding test, to observe the leakage and seepage from RCC portion.
Removing plant including roots by dismantling of brick work/PCC/RCC including necessary scaffolding any type in any location/position i.e. roof, parapet wall near pipes etc and applying concentrated hydrochloric or sulphuric acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC (1:2:4) type B0 & 10mm thick plaster in cement mortar (1:3) size of disturbed portion 150mm X150mmX200mm complete all as specified and directed.
PART-II Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing caping of suitable size and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch.
One 5 pin 6 Amps socket point controlled by one 6 Amps switch on independent board.
One 5 pin 6 Amps socket point controlled by one 6 Amps switch on same board.
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2 way switches.
Ditto - all as per Item No.164.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on independent board.
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on same board.
Ditto- all as per item No. 164.00 here-in-before but point wiring with 4.0 sqmm and earth conductor of size 4.0 sqmm for one 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on independent board complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 2 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular type bell push 10 Amps, single pole, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular type switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch.
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board.
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board.
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches.
Ditto - all as per Item No.178.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on independent board.
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on same board.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch socket combination, 6 Amps, 5 pin, flush type, 2 in 1, 240 volts, ISI marked complete all as specified and directed.
S&F of switch socket combination, 6/16 Amps, 6 pin, flush type, 2 in 1, 240 volts, ISI marked complete all as specified and directed.
S&F of stepped type (0-4/5 step) piano type electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH & Tube cat No. PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Philips Cat No. TMC501P1XT LED 22WP 3241 for batten and Essential LED TUBE 20W B2B865T8 for tube/SURYA Cat No. SUB118T8LED for batten and SLE TL DS 20 PC REFORM (NANO) or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size other fixing accessories complete all as specified and directed. (Make: Philips Cat No. WT202W LED 6 SCW PSU S2PC/Havells Cat No. LUMILINE + BS10WLED 865 SPCSS/SURYA Cat No. SLEBT10IL or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F LED light fitting 1x9W/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including fixing arrangements at any hight with nuts, screws and washers and connected to ceiling rose complete all as specified and directed. (Make: Philips Cat No. WT202WLED6SCWPSUS2PC/SURYA Cat No. SLE BH 10W/Bajaj Cat No. BIBWP10W LED or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F round shape 15 Watt, 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: SURYA Cat No. ATHENA SLE DLR 15W XXRD/Havells Cat No. INTEGRANXTDLR15W LED 857S/Bajaj Cat No. BGSLO Sleek Recess RD15W HW LED or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of recess mounting 2'x2' LED 35/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Crompton Cat No. LCTLRNE-36-F0-CDL/Havells Cat No. VENUSNEOHE2x2R36WLED857PIRSENSOR/ Philips Cat No. RC 383B LED 36S-6500 PSU OD WH PIR/SURYA Cat No. SLE DS 3622R ASTRUM or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 8 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make: Legrand cat No.5077 32, 8 way /L&T Cat No.DBVTH008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 8 way 8+24 modules suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make:- Legrand cat No. 5076 82 8 way /L&T Cat No. DBTPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way /L&T Cat No. DBTPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat as including taking down old unserviceable one complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way /L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way /L&T Cat No. DBSPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed.
S&F of MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, four pole, 40 Amps to 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed . (Note for item No. 200.00 to 202.00 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after and including taking down of unserviceable one complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F in repairs of MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz complete all as specified and directed. (Make - L&T Cat No. CM91712OOKOOG or equivalent of Legrand Cat No. 4200-55 or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for 40 mm bore GI pipe (medium grade) fixed with wall with maximum span of 4.0 meters suitable for hanging of ceiling fan with and including necessary cutting hole in brick/stone wall and making good the same with PCC (1:2:4) type B-1 as required including taking down old unserviceable pipe complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed.
S&F of 60 watt LED street light fittings, 230 V, IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary electric connection with suitable size copper cable after and including taking down old unserviceable fittings complete all as specified and directed. (Make :- SURYA CAT NO-SLE UL 60W IP66LXN, HAVELLS CAT NO. ENDURASUNDOWN SL 60W LED 765PASYBOTG, PHILIPS CAT NO. BRPO56LED59CWSLFPSUSL or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
Taking down carefully ceiling fans at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pin, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfoctory performance complete all as specified and directed.
Ditto-all as per Item No.209.00 here-in-above but exhaust fan of PVC/Metal body 250 mm sweep complete all as specified and directed.
Ditto-all as per Item No.209.00 here-in-above but exhaust fan of PVC/Metal body 300 mm sweep complete all as specified and directed.
Ditto-all as per Item No.209.00 here-in-above but exhaust fan of PVC/Metal body 380 mm to 450mm sweep complete all as specified and directed.
Ditto-all as per Item No.209.00 here-in-above but air circulator wall mounted type 450mm to 600mm sweep including carrying out repairs to oscillation mechanism/speed regulation mechanism and making functional performance complete all as specified and directed. {Note for Item No. 209.00 to 213.00 : (i) Spare parts will be measured and paid separately under relevant item of schedule as "Supply only". (ii) Rewinding of fan motor, painting will be measured and paid separately under relevant item of schedule. (iii) Labour charge for taking out and refixing of "Supply only" materials deemed to be included in quoted rate.}
Supply only capacitor 1.5 MFD, 240 volts, 50Hz complete all as specified and directed.
Supply only capacitor 2.5 MFD, 240 volts, 50Hz complete all as specified and directed.
Supply only capacitor 3.15 MFD, 240 volts, 50Hz complete all as specified and directed.
Supply only ball bearing complete all as specified and directed. (Make: SKF Cat No. 6201/6202 or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
Supply only ball bearing complete all as specified and directed. (Make: SKF Cat No. 6203/6204 or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
Supply only gun metal bush suitable for ceiling fan/exhaust fan/air circulator/wall mounted fan any sweep/type complete all as specified and directed.
Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan any sweep/type complete all as specified and directed.
Supply only down rod made of MS pipe medium grade 15mm dia of 600 mm long duly drilled holes bot ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to down rod with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply only copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 volts grade 3 core, 1.50 sqmm and including electric connection from ceiling fan to ceiling rose complete all as specified and directed. (Note for Item No. 214.00 to 222.00 :- Material of Item No. 214.00 to 222.00 to be incorporated in item No. 209.00 to 213.00 here-in-before)
Cutting the existing surface wall of brick/stone masonary and making round hole at any height suitable for fixing 300 to 450 mm sweep exhaust fan including providing nut, bolt and washers after grouting in PCC including 3mm dia 5cm aperature MS jali of required size fixed in wooden frame to avoid insects, fixed to outer surface of wall and making good the disturbed surface complete all as specified and directed.
M&L for painting to ceiling fan complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation surfaces including marking of MES Number with black paint complete all as specified and directed. (Note:-Painting work to be carried out after taking out of ceiling fan)
M&L for painting to exhaust fan complete body, blade assembly, frame etc of 300 mm to 450 mm any sweep /make/model with two coat of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation of surfaces including marking of MES Number with black paint complete all as specified and directed . (Note:-Painting work to be carried out after taking out of exhaust fan)
M&L for rewinding of ceiling fan motor of 1200 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing, including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
M&L for rewinding of ceiling fan motor of 1400 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
M&L for rewinding of exhaust fan motor of 250mm sweep to 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor fixing back and testing including removing burnt out copper winding wire complete all as specified and directed.
M&L for rewinding of exhaust fan motor of 380mm sweep to 450 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor fixing back and testing including removing burnt out copper winding wire complete all as specified and directed.
M&L for rewinding of air circulator fan motor 450 mm sweep to 600 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from air circulator fan motor complete all as specified and directed.
Taking down storage type water heater (Geyser) 25 Ltrs capacity of any make/model/type from existing wall after disconnecting of electric and water supply connections and keeping the same in safe custody for carry out repairs/replacement of unserviceable spare parts & components such as heating element, thermostat,pilot lamps with wiring,insulating glass wool, thermal cut out,pressure release valve,safety valve,aperature plate assembly etc and exmine water tightness of inner storage tank after cleaning and renewal of rubber washer/gasket and nut,bolts and washers etc and adjust to required range of thermostat control and assembling all parts/ accessories including fixing back in same location after connecting up of water & electric connections and testing for its satisfatory functioning complete all as specified and directed. {Note :- (i) Spares will be measured and paid separately under relevant item of this schedule as "Supply only". (ii) Labour charge for taking down and fixing of 'Supply only" materials are deemed to be included in quoted rate. }
Supply only heating element 2.0 KW, suitable for storage tyep water heater complete all as specified and directed.
Supply only thermal cut out suitable for storage type/instant type water heater (geyser) of any type/capacity complete all as specified and directed.
Supply only aperature plate assembly suitable for storage type water heater (geyser) 25 litre capacity complete all as specified and directed.
Supply only copper inner tank suitable for storage type water heater (geyser) 25 litre capacity complete all as specified and directed.
Supply only geyser indicator pilot lamp (red and green lamps) with wiring round/square/rectangle suitable for geysers of any type complete all as specified and directed.
Supply only 15mm dia PVC connection pipe , 450mm long with end nuts and washer, suitable for hot water outlet of geyser including taking down old unserviceable pipe complete all as specified and directed.
Supply only 15mm dia PVC connection pipe, 600mm long with end nuts and washer, suitable for hot water outlet of geyser including taking down old unserviceable pipe complete all as specified and directed.
Supply only 15mm dia PVC connection pipe, 450mm long with end nuts and washer, suitable for cold water inlet of geyser including taking down old unserviceable pipe complete all as specified and directed.
Supply only 15mm dia PVC connection pipe, 600mm long with end nuts and washer, suitable for cold water inlet of geyser including taking down old unserviceable pipe complete all as specified and directed.
Supply only 15mm dia angular stop valve, cast copper alloy chromium plated with crutch handle screwed both ends for GI pipe/fittings including taking down old unserviceable one complete all as specified and directed. (Note for Item No. 232.00 to 241.00 :- Materials of Item No. 232.00 to 241.00 to be incorporated item No. 231.00 here-in-before)
M&L for painting to storage type water heater(Geyser) of capacity 25 litre of any make/type to complete external body with two coats of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation of surfaces including marking MES Number with black paint complete all as specified and directed. {Note:-Painting work to be carried out after taking out of storage type water heater (geyser) }
SINGH ENTERPRISE
TAMALIKA ENTERPRISE
Kiran Traders
R N CHATTERJEE
JAIN CONSTRUCTION AND ENGINEERS
CHATTERJEE CONSTRUCTION AND SUPPLIERS
MAZUMDER AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .