Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹14.0 L Quoted ₹15.0 L | L1 | Accepted-AOC ACCEPT |
| 2 | L2₹17.6 L+₹2.6 L (17.0%)Rejected-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹17.6 L+₹2.6 L (17.0%) | L2 | Rejected-AOC REJECT |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
8 Nov 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
SPECIAL REPAIR TO BUILDING NO. DS 5 KL OR MD ACCN AT LANSDOWNE UNDER AGE (I) LANSDOWNE
2021_MES_481433_1
87074/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE(I) Lansdowne
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE(I) Lansdowne
₹39,000
Yes
24 Nov 2021
12 Oct 2021
10 Nov 2021
12 Oct 2021
8 Nov 2021
26 Oct 2021
12 Oct 2021 - 18 Oct 2021
Amount
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ -150) as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as Specified & directed by GE/Eng-in-Charge.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog) .
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ- 150) as in ridges, hips, valleys/rain water / roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog)
Dismantling timber scantling 40 sqcm and over in section,in any position, any description complete all as specified and directed.
M & L for 2nd class softwood in timber scantling for wall panelling, ceiling, roof truss,post, purlins, rafters and similar work (Clean sawn Timber framed and fixed type) including necessary coating framed joints with glue, complete all as specified and directed.
Dismantling of timber scantling in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section in any description complete all as specified and directed.
S & F 2nd class hard wood fillets square or rectangular or triangular in section wrought fixed to wall with screw area exc 13 but n. exc 25 sq cm complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for 2nd class soft wood boarding 20 mm thick planed one side, rebeted or fixed with screw, fixed to timber frame work with nails complete all as specified and directed. .
M & L for 2nd class hard wood boarding 40 mm thick planed one side, with joints and fixed with nails complete all as specified and directed. .
M&L for Second class hard wood (SAL), plain,solid,straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and as directed.
S& F for 40 mm thick, IInd class hard wood (SAL) plain, framed, panelled factory made shutters ( ISI Marked) (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed. Note:- Before procurement of door the contractor has to produce the sample of door(factory made) for approval and refernce
S & F 35 mm thick Second class hard wood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.Complete all as specified and directed Note:- Before procurement of door the contractor has to produce the sample of door(factory made) for approval and refernce
S&F, in repair, for Stainless steel wire cloth non megentic of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples. Complete all as specified and directed by Engineer in Charge .
S&F Stainless non megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed by Engineer in Charge
S & F Aluminium alloy anodised sliding door bolt with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections cast aluminium alloy lenght of 250 mm.complete all as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section. complete all as specified and directed.
S & F aluminium handle 150 mm long anodised, extruded type fixed complete.complete all as specified and directed.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.complete all as specified and directed.
Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel paint (Ordinary tint) .complete all as specified and directed.
Dismantling wrought iron or mild steel of any description not otherwise provided for ,complete all as specified and directed
M/L Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165. complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.complete all as specified and directed.
S & F MS sheet as in base plate, gusset plate etc welded or riveted to steel staircases including holding down bolts , nuts, rivets, etc confirming to Fe-410-W(Gde-E-250) Quality-A complete all as specified and directed
Preparation of New or previously untreated steel and iron surfaces of any description, over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide.complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality over a one coat of red oxide primer complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etcand removing unserviceable material,outside of A 1 defence land complete all as specified and directed
Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even fair complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Material & labour for Rendering 5 mm thick CM 1:3 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing compound. ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Supply & Fixied in repair ,tiled false ceiling of Everest tile (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gsm, both side inclusive and black painted groove on all T webs) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32mm made of 0.30mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20x0.40 mm and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width,including making good all the disturbed portion with existing surface with necesary arrangemnets of scaffolding all complete at all heights as per direction of Engineer-in-charge.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch.
One socket outlet 5/3 pin 5 Amps controlled by one switch on independent board.
All as per item No 2 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.complete all as specified and directed.
Supply and fixing switch modular , one-way 6Amps, 1 module 240 Volts AC. complete all as specified and directed.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module complete all as specified and directed.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting ISI marked complete all as spd & directed by GE/Engr-in-Charge.
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked complete all as spd & directed by GE/Engr-in-Charge.
S&F MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure,double door type,complete all as spd & directed by GE/Engr-in-Charge.
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as spd & directed by GE/Engr-in-Charge.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as spd & directed by GE/Engr-in-Charge.
Supply & fixing MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as spd & directed by GE/Engr-in-Charge.
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as spd & directed by GE/Engr-in-Charge.
S&F LED tube light batten 20 Watt, 4ft, Polycarbonate housing, translucent diffuser, With LED Light Source, 2200 Lumens, natural White, Surge Protection range- 2KV, Voltage Protection range – 120 -280VAC, 2 years warranty , System efficacy not less than 110Lm/Watt for the fitting, power factor >0.95, total harmonic distortation<20%, Color rendering index >80, Coefficient Colour Temperature – 6500K, Fixed on site with all accessories all as specified & directed. Cat No: SZSLBMX020 of shakti Cat No,C&S LTTB4F20WLEDof C&S LM79 and LM 80 Reports to be produced. BIS Certification must.
S&F LED Bulb 10 Watt (Cool day light) housing made from polycarbonate, with opaque diffuser, having Colour temp 6500 K and lumen output 950, voltage range 120V-280V AC, power factor >0.9, THD <33% suitable for “B-22 type to fix on batten holder Make : Shakti/Havells/Wipro/C&S.
S&F in repair Wall Bracket light fitting (Bldg Security light) 20W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts consisting of reflective lens, wired with appropriate driver PF>0.98 having over voltage protection up to 400 volts, surge protection level 7 - 10 KV, thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and LED lumen efficiency >120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.2 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete. Make:-SZPCLPM020 of Shakti /LTESSG20WLED of C&S Note : Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
S&F sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 6 Sqmm with 6 Sqmm FRLSH PVC insulated, unsheathed, stranded copper conductor cable as earth wire in existing surface/recessed steel/PVC conduit and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 6 sqmm cable shall be measured as one unit Make:- Havells,KEI,Universal,RPG,Gloster
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16sqmm 4core complete all as Specifed and directed. Note:- The Earth work,GI pipe Shall be measured and paid Sepretely under appropriate item of Sch A
Excavation in trenches in all type of soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Material and Labour for sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. (Note:- Punned thickness shall be considered for payment purpose.)
Supply and laying well burnt clay brick old size class 'B' laid dry flat for protection over the cable, width equal to the length of brick complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 32 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road for cable protection etc. complete all as specified and directed .
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Panwar Electrical
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .